SLKK 5. Extract from the online catalog. Order No.:

Similar documents
UTTB 4. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.:

DIK 1,5 General data Technical data General

KDS10/SO. Extract from the online catalog. Order No.:

General data. Technical data DIKD 1,5. General. Dimensions

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

AKG 4 GNYE. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.:

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

High-current terminal block - UKH

DEK-OV- 12DC/ 24DC/ 3

PSR-SCP- 24DC/ESD/5X1/1X2/300

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

SAC-3P- 5,0-PUR/M12FR SH

Feed-through terminal block - PT 10-TWIN

SAC-5P- 1,5-PUR/M12FS SH

VC-MEMV-S1. Extract from the online catalog. Order No.:

MACX MCR-EX-SL-RPSSI-I

Extract from the online catalog

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

VC-MEMV-K3. Extract from the online catalog. Order No.:

Data sheet. W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 10

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Data sheet... W-Series WDU 2.5

VARIOCON. Modular Contact Inserts

VC-MP-K1. Extract from the online catalog. Order No.:

Datenblatt. W-Series WDU 2.5

Datenblatt. W-Series WDU 10

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Datasheet. W-series terminal with clamping yoke connection WDU 16

Through and Ground Conductor Terminal Blocks 290 Series

Signal conditioner - MACX MCR-UI-UI-NC

Safety relays - PSR-SCP- 24DC/ESD/4X1/

PHOENIX CONTACT

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT

Subject to changes 11/2003 Page 1/7

Extract from the online catalog

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

ELECTRICAL INFORMATION K012-A135-MP5.0/02 2 K012-A135-MP5.0/03 3. Molding Nylon PA66 to UL94, V-O Colour Green. Torque 3.5 lbs-in

The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Electronic Circuit Protector ESX10-T

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346

Accessories. Accessories

No-wear isolation of potentials in terminal block design

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

MINI MCR-SL-UI-I-LP-NC

Medium-base Lampholders

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

MINI MCR-SL-UI-f(-SP)

Modular Plug Connectors compliant to Cat.6 A Standard

Solid State Relay, 1-phase

Electronic timer CT-SDS.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Feed-through terminals

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Switching power supplies CP range, Linear power supplies CP-L range. Content

Three-phase monitoring relays

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

SPRING CLAMP TERMINAL

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

Electronic timer CT-SDD.22

Safety switches with slotted hole lever

The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Data sheet C6 A modul K 180 jack - Keystone style

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Ground Clamps Cable Tray

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

ACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:

Connector MACHINE PIN SOCKET EMS SERIES FEATURES SPECIFICATIONS KINDS OF BASE

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Data sheet C6 A modul K 90 jack - keystone style

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Transcription:

Extract from the online catalog SLKK 5 Order No.: 0461018 Double-level terminal block with protective conductor foot, cross section: 0.2-4 mm², width: 6.2 mm, color: Gray Commercial data EAN 4017918002381 Pack 50 Pcs. Customs tariff 85369010 Weight/Piece 0.02252 KG Catalog page information Page 302 (CL-2007) Product notes WEEE/RoHS-compliant since: 01/01/2003 http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data General Number of levels 3 Number of connections 5 Color Insulating material Inflammability class acc. to UL 94 gray PA V0 PHOENIX CONTACT GmbH & Co. KG Page 1 / 7

Dimensions Width Length Height NS 35/7,5 Height NS 35/15 6.2 mm 66.5 mm 69.5 mm 77 mm Technical data Rated surge voltage 6 kv Pollution degree 3 Surge voltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-1 34 A 500 V Connection data Conductor cross section solid min. 0.2 mm 2 Conductor cross section solid max. 4 mm 2 Conductor cross section stranded min. 0.2 mm 2 Conductor cross section stranded max. 4 mm 2 Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 10 without plastic sleeve min. without plastic sleeve max. with plastic sleeve min. with plastic sleeve max. 0.25 mm 2 4 mm 2 0.25 mm 2 2.5 mm 2 2 conductors with same cross section, solid min. 0.2 mm 2 2 conductors with same cross section, solid max. 1.5 mm 2 2 conductors with same cross section, stranded min. 2 conductors with same cross section, stranded max. ferrules without plastic sleeve, min. 0.2 mm 2 1.5 mm 2 0.25 mm 2 PHOENIX CONTACT GmbH & Co. KG Page 2 / 7

ferrules without plastic sleeve, max. TWIN ferrules with plastic sleeve, min. TWIN ferrules with plastic sleeve, max. 1.5 mm 2 0.5 mm 2 1.5 mm 2 Cross-section with insertion bridge, solid max. 4 mm 2 Cross-section with insertion bridge, stranded max. 2.5 mm 2 Type of connection Stripping length Internal cylindrical gage Screw thread Tightening torque, min Tightening torque max Screw connection 8 mm A3 M3 0.6 Nm 0.8 Nm Certificates / Approvals Approval logo CSA 600 V 25 A AWG/kcmil 28-12 CUL 600 V 30 A AWG/kcmil 26-12 UL 600 V 30 A AWG/kcmil 26-10 Certification CSA, CUL, GOST, PRS, UL PHOENIX CONTACT GmbH & Co. KG Page 3 / 7

Accessories Item Designation Description Assembly 2770024 D-UKK 3/5 Cover for setting the end of a terminal row, width: 2.5 mm, color: Gray 2770817 DG-UKK 3/5 Cover, width: 2.5 mm, color: gray 2770794 DP-UKK 3/5 Spacer plate, compensates for level offset if standard terminal blocks are to be fitted adjacently, 2.5 mm thick 0201595 FB-150 METER Cross connection rail, for fixed bridging of identical inputs and outputs, made of Cu, nickel-plated, 1 m long 0801762 NS 35/ 7,5 CU UNPERF 2000MM DIN rail, material: Copper, unperforated, height 7.5 mm, width 35 mm, length: 2 m 0801733 NS 35/ 7,5 PERF 2000MM DIN rail, material: Steel, perforated, height 7.5 mm, width 35 mm, length: 2 m 0801681 NS 35/ 7,5 UNPERF 2000MM DIN rail, material: Steel, unperforated, height 7.5 mm, width 35 mm, length: 2 m 1201895 NS 35/15 CU UNPERF 2000MM DIN rail, material: Copper, unperforated, 1.5 mm thick, height 15 mm, width 35 mm, length: 2 m 1201730 NS 35/15 PERF 2000MM DIN rail, material: Steel, perforated, height 15 mm, width 35 mm, length: 2 m 1201714 NS 35/15 UNPERF 2000MM DIN rail, material: Steel, unperforated, height 15 mm, width 35 mm, length: 2 m 2770215 TS-KK 3 Separating plate, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch, color: Gray Bridges 0201155 EB 2-6 Insertion bridge, 2-pos., fully insulated 0201142 EB 3-6 Insertion bridge, 3-pos., fully insulated 0201139 EB 10-6 Insertion bridge, 10-pos., divisible, fully insulated 0203250 FBI 10-6 Fixed bridge, 10-pos., screw heads with insulating collar, divisible, with screws 0201650 FBI 100-6 Fixed bridge, 100-pos. 0201867 FBI 20-6 Fixed bridge, 20-pos. 1302338 IS-K 4 Bridge bar isolator, as distance piece 0301505 ISSBI 10-6 Isolator bridge bar, 10-position, divisible, with screws, for switchable branches 0202280 LB 10-6 BU L-bridge, 10-position, screw with blue insulation material 0202358 LB 10-6 GY L-bridge, 10-position, screw with gray insulation material 0202293 LB 10-6 RD L-bridge, 10-position, screw with red insulation material PHOENIX CONTACT GmbH & Co. KG Page 4 / 7

0202303 LB 100-6 BU L-bridge, 100-position, screw with blue insulation material 0202345 LB 100-6 GY L-bridge, 100-position, screw with gray insulation material 0202316 LB 100-6 RD L-bridge, 100-position, screw with red insulation material 1413230 SBRN 2-7 Switching bridge, 2-pos. 2303239 USBR 2-7 Switching bridge, 2-pos. 2305538 USBRJ 2-7 Switching bridge, for bridged terminal groups, 2-pos. Marking 1007222 SBS 6:UNBEDRUCKT Marker cards for modular terminal blocks, color: white 1004115 WS 3-6 Warning plate, with 2 plastic screws, across 3 terminal blocks, pitch 6 mm 1004209 WS 4-6 Warning plate, with 2 plastic screws, across 4 terminal blocks, pitch 6 mm 1004403 WS 5-6 Warning plate, with 2 plastic screws, across 5 terminal blocks, pitch 6 mm 1050499 ZB 6:SO/CMS Zack strip, 10-section, divisible, special printing, marking according to customer requirements Plug/Adapter 0309523 KSS 3-6 Short circuit connector, for short circuiting neighboring terminal blocks, can only be used with PSB or PSBJ, 3-pos., pitch: 6.2 mm, color: Black 0301547 KSS 6 Short circuit connector, for short circuiting neighboring terminal blocks, can only be used with PSB or PSBJ, 2-pos., pitch: 6.2 mm, color: Black 0601292 PSB 3/10/4 Test plug socket, not insulated, length: 10 mm, screw thread width: 3 mm, socket width: 4 mm 0201304 PSBJ 3/13/4 Test plug socket, insulated, length: 13 mm, screw thread width: 3 mm, socket width: 4 mm, insulation material transparent 0201647 RPS Reducing plug, for transition from 4 mm diameter test plug socket, insulation: gray PHOENIX CONTACT GmbH & Co. KG Page 5 / 7

Drawings Circuit diagram 1 = cover 2 = spacer cover 3 = spacer plate 4 = fixed bridge 5 = insertion bridge 6 = separating plate PHOENIX CONTACT GmbH & Co. KG Page 6 / 7