Armoured Power and Control Cables to BS6883

Similar documents
Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables Fire Resistant

Armoured Instrumentation Cables to BS6883

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Welding Cables Rubber Insulated

Kerman & Kavian Cable Industries ( KCI )

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

H05Z-K / H07Z-K BS EN LSZH Wire

CIR (Crush & Impact Resistant) VFD Power Cable

P Low Voltage Catalogue Cables Australia Powering your Project

H07RN-F BS EN Flexible Rubber Cable

GEXOL WORLD CLASS OIL & GAS CABLES

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

MarineLine YOZp 0,6/1 kv

Product information. Marine, Oil & Gas.

DNVGL-CP-0400 Edition December 2015

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Marine Cables General Catalogue

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

FLEXIBLE MULTI CORE CABLES

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

INTERNATIONAL STANDARD

Installation Recommendations

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Flexitime! Our flexible cables save you time and money.

Notes 3 Explanatory Information 4-10

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Tri-Rated Flexible PVC Equipment Wire

SUBMERSIBLE PUMP CABLES

T E C H N I C A L D A T A for

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

SUPERIOR MARINE CABLE SOLUTIONS

Railway products. Edition 2014

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

CABLES AND WIRES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Technical Specification. for 1.1 KV Copper Control Cable

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

kv: medium voltage reeling cable with fibreoptics

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

ABOUT US ABOUT US 1 CRANE CABLES

IEC Standard Caledonian Offshore & Marine Cables

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Selection table for flat & ribbon cables

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Specification for pvc-insulated cables for electricity supply

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Complete, innovative cables range for shipbuilding industry

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

VSD cables in. Working with. industrial & automation applications

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Medium Voltage Power Cables

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Busbar and Modular Wiring Systems

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Power Cables and their Application

DLO Flexible Power Cable

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

LIST OF IS STANDARDS FOR ELECTRICAL PROJECTS

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

a Nexans company Catalogue 2009

Spec wire. Performance Wire and Cable

a Nexans company Catalogue 2012

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

14 AWG 2 AWG: 600 Volt

List Price w.e.f. 02nd January, 2018

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

a Nexans company Catalogue 2012

Transcription:

Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in ships and in mobile and fixed offshore units (e.g. drilling rigs, oil platforms, etc.). For use in regularly occupied areas such as accommodation facilities, control rooms and computer suites. Any application where life may be endangered by smoke and noxious fumes and where vital, sensitive equipment may be damaged by acid forming gases. Specifications In accordance with BS Conductor: Tinned annealed copper. Stranded to BS EN 0 Class or flexible to BS EN 0 Class Insulation: EPR complying with BS GP Core Identification: The cores shall be identified by numbers unless requested otherwise Inner Sheath: Will be the same material as the outer sheath, based generally on the requirements of BS section. Type SW. Enhanced oil resistance, low smoke zero halogen, minimum tear resistance Armour: wire braid in the following optional materials: - Galvanised mild steel to BS EN - - Tinned phosphor bronze to BS EN - Copper to BS EN 0 N.B. Galvanised mild steel should not be used on single-core cables where used for a.c. circuits. Outer Sheath: As inner sheath. Identification legend will include manufacturers name, voltage, BS, number of cores and c.s.a. cable sheath class (e.g. SW), IEC 0 and UK00A code where applicable Standard sheath colour is black. Other colours available on request Oxygen index >%. Temperature index 0 C, HCL emission <0.% of weight of compound at 00 C Flame retardant to IEC0-- Category A (reduced propagation) Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V For flexible conductors add suffix F to part number, these will not be covered by the UK00A code. 0

Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Anixter Number UK00A Nominal Nominal Diameter Over Minimum Maximum Approx Anixter No Anixter Code Cond Area Cond Stranding Inner Sheath Minimum Maximum O/D O/D Weight Prysmian EXF Number Hawke mm #/mm mm mm mm mm kg/km Gland Gland Single-Core EBP-EXF EDZ-UNI BS-C-000(F)* WA0 0 /..... - - BS-C-000(F)* WA0 0 /..... 0 - - BS-C-00(F)* WA /..... - - BS-C-00(F)* WAA 0 /.0....0 - - BS-C-00(F)* WAB 0 /..... - - BS-C-0(F)* WAC /..0. 0.0. - - BS-C-00(F)* WAD 0 /..... -0-0 BS-C-000(F)* WAE 00 /. 0.0.. 0.0-0 -0 Two Core BS-C-00 WB. 0/0.....0 -S -S BS-C-00 WB. /0..... -S -S BS-C-000 WB.0 /0..... 0 - - BS-C-000 WB.0 /.0.... - - BS-C-00 WB /..... - - BS-C-00 WB /.0.... - - BS-C-00 WB /..... - - Three Core BS-C-00 WB0. 0/0...0.. -S -S BS-C-00 WB0. /0...0.0. 0 -S -S BS-C-000 WB0.0 /0..0... 0 - - BS-C-000 WB0.0 /.0.... 0 - - BS-C-00 WB.0 /...0.. - - BS-C-00 WB.0 /.0.... - - BS-C-00 WB.0 /..... - - BS-C-00 WB.0 /... 0.. - - BS-C-000 WB0 0.0 /....0. -0-0 BS-C-000 WB0 0.0 /..... 0-0S -0 BS-C-00 WB.0 /..... -0-0 BS-C-00 WB0A 0.0 /.0 0...0. -0-0 BS-C-00 WB0B 0.0 /..0... -S - BS-C-0 WB0C.0 /. 0.... - - BS-C-00 WB0D 0.0 /.. 0.. 0. -S - * Add F to the part number for flexible conductors e.g. BS-C-0F. The UK00A code only relates to the stranded conductor. Continued overleaf... 0

Armoured Power and Control Cables to BS Low Smoke Zero Halogen (continued) Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Anixter Number UK00A Code Nominal Cond Area mm Nominal Cond Stranding #/mm Diameter Over Inner Sheath Minimum Maximum mm mm Minimum O/D Maximum O/D Approx Weight Anixter No Prysmian EXF Gland EBP-EXF Anixter No Hawke Gland mm mm kg/km EDZ-UNI Four Core BS-C-00 WB0. 0/0..... -S -S BS-C-00 WB0. /0...0.. - - BS-C-000 WB0.0 /0..... - - BS-C-000 WB0.0 /.0.... - - BS-C-00 WB.0 /..... - - BS-C-00 WB.0 /.0.... - - BS-C-00 WB.0 /... 0.. -0 N/A BS-C-00 WB.0 /.....0-0 -0 BS-C-000 WB0 0.0 /. 0... 0. -0S -0 BS-C-000 WB0 0.0 /.....0-0 -0 BS-C-00 WB.0 /. 0.... 0-0 -0 BS-C-00 WB0A 0.0 /.0.... -S - BS-C-00 WB0B 0.0 /. 0.... - - BS-C-0 WB0C.0 /..0... -S - 0

For further technical information refer to page :. Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Anixter Number UK00A Nominal Nominal Diameter Over Minimum Maximum Approx Anixter No Anixter Code Cond Area Cond Stranding Inner Sheath Minimum Maximum O/D O/D Weight Prysmian EXF Number Hawke mm #/mm mm mm mm mm kg/km Gland Gland Seven Core EBP-EXF EDZ-UNI BS-C-00 WB0. 0/0....0. - - BS-C-00 WB0. /0..... 0 - - Twelve Core 0/ BS-C-00 WBA0. 0/0..... - - BS-C-00 WBA0. /0..... - - Nineteen Core 0/ BS-C-00 WBB0. 0/0..... - - BS-C-00 WBB0. /0.....0 - - Twenty Seven Core 0/ BS-C-00 LBC0. 0/0.... 0.0 - - BS-C-00 LBC0. /0..... -0-0 Thirty Seven Core 0/ BS-C-00 LBD0. 0/0..... 0-0 -0 BS-C-00 -. /0.. 0... -0-0 0

Twin and Multicore Cables, EPR Insulated Continuous current ratings for groups of circuits (up to six cables bunched) for twin and multicore EPR insulated cables, run open or enclosed. Also applicable to mica taped fire resistant types. CURRENT RATINGS Nominal Conductor Area Twin Cables Current Rating Single Phase a.c. or d.c. Voltage Drop Per Ampere Per Metre Single Phase d.c. a.c. Three & Four Core Cables Where more than six cables are bunched, a rating factor of 0. should be applied to the current rating. For ambient temperatures other than C, the following rating factors should be applied: Ambient air temp C 0 0 0 0 0 Rating factor..0.0 0. 0. 0. 0. 0. 0. 0. Technical Information Current Rating Three Phase a.c. mm A mv mv A mv.0. 0..0.0... 0.. 0.0......... 0 0..0 0. 0 0 0. 0.0 0 0. 0 0. 0. 0.0 0 0 0. 0. 0 0. 0 0 0. 0. 0 0. 0 0. 0. 0 0. 0 0. 0. 0. 00 0 0. 0. 0. Voltage Drop Per Ampere Per Metre 0

Technical Information 00/00 V EPR Insulated cables to BS Armoured and Non-Armoured, Multicore CABLE TYPES: Multicore TCU/EPR/SW * Type 00/00 V to BS Multicore TCU/EPR/SW/GSWB/SW * Type to BS ELECTRICAL CHARACTERISTICS Conductor Size Maximum d.c. Conductor Resistance @ ºC mm ohms/km ohms/km ohms/km ohms/km... 0...*.. 0..... 0...0.0. 0...0.. 0.... 0.... 0.. 0. 0. 0. 0. 0. 0. 0. 0. 0 0. 0. 0. 0. 0 0.0 0. 0. 0. 0. 0. 0.0 0. 0 0. 0. 0.0 0. 0 0. 0. 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0. 0.0 0. 00 0.00 0.0 0.0 0. * Class (0/0.mm) flexible conductors. Maximum a.c. Conductor Resistance @ 0ºC Reactance @ 0 Hz Impedance @ 0ºC, 0 Hz 0

Installation Guide for Offshore Cables General Precautions Cables described in this section should not be installed at temperatures below minus C, nor in any situation where the cooling air temperature exceeds C. The cables meet the IEE requirement concerning impervious sheathing for cables installed on decks, exposed to weather, in damp or wet situations, in machinery compartments and in general, where water condensation or harmful vapours (including oil vapour) may be present. The sheathing compounds will withstand normal handling, installation and service but in areas where mechanical stress is envisaged unarmoured cables should be fitted in pipes or conduit or trunking. Alternatively, armoured and sheathed cables should be used. Cables should be protected from avoidable risks of mechanical damage and routed away from heat sources such as boilers, hot pipes and resistors. Cable runs should be selected to avoid action from condensed moisture or drips. Cables should not be installed across expansion joints, but where this is unavoidable a proportioned loop of cable should be arranged, suitably supported and having an internal radius not less than twelve times its diameter. For services with duplicate supplies, the cables should follow different paths and be separated as far apart as is reasonably practical. Cables and wiring for mains and emergency power, lighting, internal communications or signalling should be routed away from galleys, machinery spaces and other high fire-risk areas except when supplying equipment in those places. In situations offering considerable risk of mechanical damage, such as storage spaces, cables should be protected by steel casing, trunking or conduit if the structure or attached parts do not afford sufficient protection, even to armoured cables. Any metal casing so used should be sufficiently protected against corrosion. All cable supports and accessories should be robust and constructed from corrosion-resistant material, or suitably treated to resist corrosion. Metals or alloys with low melting points (e.g. aluminium) should not be used. Cables passing through watertight decks or bulkheads should be provided with deck-tubes, watertight glands, multi-transit assemblies, or fire-retardant packed boxes as appropriate to meet the requirements of the Authority approving the installation. 0

Where cables pass through non-watertight bulkheads, beams or other steel structure, the holes should be glanded or bushed with non-corroding materials to prevent damage to both cables and structure. The means of fixing of conductors and terminals should be capable of withstanding the thermal and dynamic effects of short circuits. When singlecore cables, having a current rating greater than 0A need to be installed close to a steel bulkhead, the clearance between cable and metal surface should be at least 0mm, Installation Guide for Offshore Cables General Precautions unless the cables belonging to the same a.c. circuit are installed in trefoil. In the interests of safety and circuit reliability, it is assumed that installers will adhere to the IEE Regulations and Recommendations for the Electrical Equipment of Ships and of Mobile and Fixed Offshore installations. Particular attention should be paid to recommendations concerning cables, with regard to their effect on navigational and radio equipment. MINIMUM BENDING RADIUS Ideally cables should be bent as little as possible and never to radii less than the following: Type of Cable* Instrumentation Power & Control up to./. kv ** Armoured up to mm D Armoured over mm D Unarmoured up to mm D Unarmoured over mm up to mm D Unarmoured over mm D Power cable./. kv and above ** Un-screened Screened - single-core Screened - three core Minimum Bending Radius x diameter x diameter x diameter x diameter x diameter x diameter x diameter x diameter x diameter * All fire survival (FS) cables - x diameter. ** x diameter Class flexible cables. 0