Pop-Out Slim Video Wall Mount

Similar documents
Installing flat panels on the MPL15 wall mount

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features VW401P. User s Manual

Video Wall Installation Instructions 2W X 3H, 3W X 3H

INSTALLATION MANUAL PBC-UMS

Projector Ceiling Mount


Assembly Instructions for Model: MF110

INSTALLATION MANUAL PBL-UMP

TP4463. ASSeMBly INSTruCTIONS FLAT PANEL TV MOUNTING SYSTEM OPTION 1 OPTION 2 OPTION 3

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Dual Arm Tilt LCD Mount

Assembly Instructions for Model: VMDD26

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

MM750 Installation Instructions

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

INSTALLATION MANUAL SP-CEIL-012

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

AS-TX86. Please read these instructions carefully before using. This model will hold most Flat Panel TVs. Load capacity: 60kg (132Lbs).

Wall mounting bracket

19 to 39 TV WALL MOUNT - FULL MOTION

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

Installation Instruction

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

MONOPRICE. Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features. User's Manual P/N 16102

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

INSTALLATION INSTRUCTIONS

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Installation and Assembly: Ceiling mount for LCD screens up to 29"

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Assembly InstructIons

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

A195FF TILT & SWIVEL TV MOUNTING BRACKET Vesa Size : 600 x 400mm User Manual Notice d Utilisation

Installation and Assembly: Full Service Video Wall Mount

LCD/Plasma Mount Manual

PWM-T210 Installation Instructions UNIVERSAL FLAT PANEL MOUNT

Full-motion Wall Mount

Owner s Manual Mobile Flat-Panel Floor Stand

MPA-9000 Universal Ceiling Projector Mount Kit

LCD DISPLAY MOUNT

**MOUNTING YOUR MONITOR

INSTALLATION MANUAL ELPMBUNI

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Full Motion Gas Spring TV Wall Mount - 24" to 55" Installation Instructions

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

QLF215 INSTRUCTION MANUAL

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

TITAN2-EDGE Public Access Computer Station Dual Track

flat panel solutions Specifications Box contents Warnings CAUTION: Tilt Wall Mount for LCD, Plasma, and LED Displays Instruction Manual

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

Assembly Instructions for Model: VMPL3

Universal flat-panel mount

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

INSTALLATION INSTRUCTIONS

QLF214 INSTRUCTION MANUAL

Full-Motion TV Mount 36" to 65" Installation Instructions

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

FML64S ASSEMBLY INSTRUCTIONS

FOR WALL MOUNT WORKSTATION

ETX Powered Loudspeaker Accessories


Gared Pro-S Portable Backstop

ALF109 Instruction Manual

Full-Motion TV Mount - 47" to 90" Installation Guide

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

QLF214 INSTRUCTION MANUAL


2 ADULTS REQUIRED FOR ASSEMBLING

P4263TP. Installation Guide. Low-Profile Tilting Portrait Mount for Flat-Panels

Wooden Frame Type Instruction Manual

TV Floor Cart and Accessories

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Universal Projector Ceiling Mount Model: DPM-45

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

LAN Locker Adjustable Shelves

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

PLA50B Instruction Manual

Gared Pro Portable Backstop

Model : TLX-350FM. TV Mount Installation Guide

FSCTD Dual Back to Back Flat Screen Ceiling Mount

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

Elo Touch Solutions Wallmounting Kit for the 7001L IDS Touchmonitors

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Wall Mount Assembly and Mounting Guide (55 /84 )

Barn Door & Hardware Installation Guide

USE AND CARE GUIDE FIXED LED / LCD TV WALL MOUNT (UNIVERSAL MOUNTING PATTERN, FITS VESA

Articulating TV/Monitor Wall Mount Model: WA300S (Butterfly Series)

LOGAN HUTCH WITH SHELVES 36

QLT25 INSTRUCTION MANUAL

Assembly Instructions for Model: SD115

Transcription:

Installation Guide ADM-VWSP Pop-Out Slim Video Wall Mount CONTENTS Installation Safety Notes Page 2 Interface Adaptors Page 3 Installation Instructions Page 4 Installation Options Page 9 Alternative Mounting Examples Page 10 Product Dimensions Page 11 COMPONENT CHECKLIST E M6 x 20mm G 4mm Short Allen Key A Wall Mount B Interface Arm - Left C Interface Arm - Right D 600mm Adaptor Arm F M8 x 12mm Countersunk (x4) H 4mm Long Allen Key Display Interface Suitable for loads up to 50kg I M6 x 16mm J M6 x 25mm K M6 x 40mm L M6 Washer M M8 x 16mm N M8 x 25mm O M8 x 40mm P M8 x 5mm Spacer Q M8 x 13mm Spacer R M8 x 24mm Spacer Required Tools for Installation Flathead & Crosshead drivers Power Drill Drill Bit Pencil Dual-Plane Laser Level: Optional IMPORTANT INFORMATION! Important: Fixing screws are not included with this product. Atdec highly recommends this product be installed by a suitably qualified person. The installer must be satisfied that the type of fixings used are suitable for the type of wall the product is to be mounted to. Care must be taken as to where this product is located as some walls are not suitable for installation. When drilling holes knowledge must be obtained to avoid contact with any electrical cables and/or gas and water pipes contained within the wall. This pack contains 1 mount. Please retain this document for future reference. ADM-VWSP Page 1 of 12

Installation Safety Instructions CAUTION: This mount is intended for use only with the maximum weights indicated. Use with displays heavier than the maximum indicated may result in instability causing possible injury. Do not attempt to install this product until all instructions and warnings have been read and properly understood. Please keep these instructions for future reference. Please check carefully to make sure there are no missing or defective parts - defective parts must never be used. Atdec Pty Ltd, its distributors and dealers are not liable or responsible for damage or injury caused by improper installation, improper use or failure to observe these safety instructions. In such cases, all guarantees will expire. General Atdec Pty Ltd recommends that a professional AV installer or other suitably qualified person install this product. Great care must always be taken during installation as most AV equipment is of a fragile nature, possibly heavy and easily damaged if dropped. If you do not fully understand the instructions or are not sure how to install this product safely, then please consult a professional for advice and/or to install this product for you. Failure to mount this product correctly may cause serious injury or death both during installation and at any time thereafter. Do not mount any AV equipment that exceeds the specific weight limit of the product you are installing. This weight limit will be clearly stated on each product and its packaging and will vary from product to product. Product Location Please pay careful attention to where this product is located. Check load capacity of wall prior to installation as some walls are not suitable for installation. Designed for indoor use, this mount is suitable for public or home installation. If located in a public or frequently populated area ensure that the product is out of the immediate reach of people. If any AV equipment is to be suspended over the likely path or location of people then great care should be taken to secure all parts of the installation from falling. If you install this product on drywall it must be securely fixed to a wooden stud, concrete block or other permanent structure behind the drywall board. Installing on drywall boards alone will not support the weight of most AV equipment. When drilling holes in walls it is essential to avoid contact with electrical cables and water or gas pipes contained within. Use of a good quality live wire detector and hidden object locator is therefore recommended. Only drill into structures when you are sure it is safe to do so. Fixing Hardware It is highly recommended that all wall fixing screws be used where supplied and that the purpose of all other fixing hardware is fully understood. In some cases more AV equipment fixing hardware will be supplied to accommodate different models of equipment and set up configurations. The installer must be satisfied that any supplied fixing hardware is suitable for each specific installation. If any fixing screws or included hardware are deemed not sufficient for a safe installation then please consult a professional or your local hardware store. Hazard Limitation When routing cables take advantage of any built in cable management features that the product might provide and ensure that all cables are tidy and secure. Check to see that any moving aspect of product can do so unhindered by any cabling. Some products have moving parts and the potential to cause injury through the crushing or trapping of fingers or other body parts. Particular attention to the nature of moving parts is required especially when assembling, installing and adjusting during set up. Immediately after installations double-check that the work done is safe and secure. Double-check all necessary fixings are present and are of ample tightness. It is recommended that periodic inspections of the product and its fixing points are made as frequently as possible to ensure that safety is maintained. If in doubt consult a professional AV installer or other suitably qualified person. ADM-VWSP Page 2 of 12

VESA 600 x 400mm Interface Adaptors The interface arms (parts B & C) can mount displays with fixing patterns from VESA 200 x 200mm up to 400 x 400mm. Mounting In Landscape To mount displays with VESA 600 x 400mm fixings use the adaptor arms (part D). i.) ii.) D B F D C Top Display Bottom Mounting In Portrait i.) ii.) B F C D IJKMNO Top D Display Bottom ADM-VWSP Page 3 of 12

Installation Instructions Step 1. Attach the interface arms to the display IJKMNO i. Completely loosen the two safety screws. ii. Fix the interface arms (parts B & C) to the back of the display using the Display Interface Kit (parts I - O). Use spacers (parts P, Q & R) for displays with recessed fixings. Safety s Step 2. Install the first mount i. Plan your video wall installation according to site requirements and display sizes. Accordingly, determine the centre of the first display at the bottom left. The rest of the video wall will be built from here. Display Centre ii. Measure and mark a point 244mm (9 5 / 8 ) vertically above the display centre. This point is the Datum. Datum 244mm (9 5 / 8 ) Display Centre iii. Place wall mount against wall. Align Top Centre Hole on the product to the Datum. Ensure product is level. Top Centre Hole 250mm (9 13 / 16 ) 244mm (9 5 / 8 ) Top Centre Hole Datum A Display Centre ADM-VWSP Page 4 of 12

iv. Fix the wall mount to the wall (use the horizontal line as a guide), using the fixing holes with suitable wall fixings (not supplied). Different fixing holes can be used according to installation requirements. Fixing Holes Keyholes on wall mount for easier installation 276mm (10 7 / 8 ) Horizontal Line Level Fixing Holes v. Measure and mark a point one screen width horizontally from the Top Centre Hole on the now-fixed wall mount. Repeat (iii) and (iv) with the next wall mount at this mark. Continue steps (iii), (iv) and (v) across the horizontal instances of the videowall. 1 Screen Width Mark point. Align Top Centre Hole to mark and level. Fix wall mount to wall. Repeat process for all wall mounts in the row. vi. To begin next row, measure and mark a point one screen height vertically from the Top Centre Hole on the left most wall mount. 1 Screen Height Mark point. Align Top Centre Hole to mark and level. Fix wall mount. Repeat process for all vertical instances. vii. Repeat steps (iii), (iv) and (v) for all horizontal instances of this row. viii. Repeat steps (vi) and (vii) until all rows have been completed. Note: If mounting in portrait, display width and height is relative to installed orientation. ADM-VWSP Page 5 of 12

Display Step 3. Hook Display onto Wall Mount i. Hook the first display onto the bottom left wall plate. Warning Fix/ tie the cables to prevent possible damage 2 3 1 Wall Wall Display Note: Safety screws need to be in the unlocked position. Tighten safety screws once all displays are mounted and aligned with each other. Note: Ensure the bottom interface arm hooks are properly mounted onto the wall plate. ADM-VWSP Page 6 of 12

Step 4. Display Alignment Y-axis adjustment Z-axis adjustment Z-axis adjustment Y-axis adjustment Adjustment lines to help with accurate display alignment Total Z axis adjustment is 15mm ( 19 / 32 ) Total Y axis adjustment is 7.5mm ( 9 / 32 ) Y-axis adjustment i. Check the horizontal centre of the display is aligned with the horizontal centre of the wall mount. ii. Using a level, align the display parallel to the floor using the Z-axis adjustment screws. This process requires Part G: 4mm Allen Key. iii. Use the Y-axis knob to ensure that each corner of the display is equidistant from the wall. iv. Use a plumb to align the first column of displays and leave a 1mm ( 1 / 32 ) gap between them. v. Hook on the remaining displays leaving at least a 1mm ( 1 / 32 ) gap between them. 3. 1mm Level 2. Y Y 1. 4. Y Y Plumb 1mm vi. When the displays are all positioned correctly, tighten the safety screws which were previously loosened. vii. Fix cables using the cable fixing holes and cable ties if required. A C B H ADM-VWSP Page 7 of 12

Step 5. Servicing the Displays i. To service the display, push the display and the mount will release and move out from the wall. Be careful not to damage the display when pushing. Keep hold of the display as it moves outwards. Note: Push at the top and bottom of the display on the bezel. To avoid any flexing (and when spacers have been used) apply light pressure in-line with the interface arms, pushing alternative arms at the top and bottom simultaneously (see fig. 1). ii. Display shown in the service position. iii. When servicing is complete, push the display back and click into place. iv. Optional: Adjustments can be made to ensure these parts move freely. If overtightened, it will negatively affect the pop-out/in function of the product. If too loose, it will create lateral wobble. Note: If the pop-out function of the bracket is not operating, check that the locking screw (part E) has not been engaged - see page 12. ADM-VWSP Page 8 of 12

Installation Options Installing the Locking If this mount is used in public areas, a locking screw is available to prevent the mount from popping out accidentally. Ensure the wall mount (part A) is in the closed position before inserting the locking screw (part E). E H A E H Recess Mounting ( 1 /32 ) Recess Depth = 63mm (2 15 /32 ) * + Depth of Display. * Add 6mm ( 1 /4 ) if 600mm adaptor arms (Part D) are used. ADM-VWSP Page 9 of 12

Alternative Installation Examples ADM-R Rail Installation ADM-R ADM-VWSP Single Floor To Ceiling Vertical Pole Installation ADM-TM Note: Guidelines of display manufacturer should be followed for all installations. ADM-T ADM-TM Bases must be fixed to the floor ADM-VWSP Page 10 of 12

ADM-VWSP Product Dimensions Rear View 620mm (24.41 ) 620mm (23.62 ) 573mm (22.56 ) Max: 430mm (16.93 ) 8.6mm (0.34 ) 20mm (0.79 ) 541.4mm (21.31 ) 400mm (15.75 ) 300mm (11.81 ) 200mm (7.87 ) 100mm (3.94 ) 8.6mm (0.34 ) 54.5mm (2.15 ) Side View Extended Min: 227.6mm 1.5mm (8.96 0.06mm) Max: 242.6mm 1.5mm (9.55 0.06mm) Interface arms are set at the lowest point. Height adjustment range: +15mm (0.59 ) 6mm (0.24 ) 600 Ada Arm ADM-VWSP Page 11 of 12

No portion of this document or any artwork contained herein should be reproduced in any way without the express written consent of Atdec Pty Ltd. Due to continuing product development, the manufacturer reserves the right to alter specifications without notice. 20171207A atdec.com ADM-VWSP Page 12 of 12