profile New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 4294A

Similar documents
Agilent 4294A Precision Impedance Analyzer 40 Hz to 110 MHz Technical Overview

Permittivity Measurements of PC Board and Substrate Materials using the HP 4291B and HP 16453A

Optimizing Electronic Component and Material Impedance Measurements

Keysight Technologies E4990A Impedance Analyzer. 20 Hz to 10/20/30/50/120 MHz

Network, Spectrum, and Impedance Evaluation of Electronic Circuits and Components

Wide Range DC Current Biased Inductance Measurement. Application Note with HP 4284A Precision LCR Meter / HP 42841A Bias Current Source

HP 8491A/B, 8492A, 8493A/B/C, 11581A, 11582A and 11583A/C Coaxial Attenuators. Product Overview

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

HP 4286A RF LCR Meter. Technical Specifications. Specifications. Test Signal

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

6.5-Digit Multimeter, High- Accuracy, C-Size HP E1410A Technical Specifications

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

HP 8921A Cell Site Test Set. Product Note AMPS Base Station Testing

HP 8560 E-Series Spectrum Analyzers Technical Specifications

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note


Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

Better. Hints. Microwave Counter. for making. Measurements

HP 8647A and 8648A/B/C/D Signal Generators Technical Specifications

Agilent 4395A Network/Spectrum/Impedance Analyzer 500 MHz 4396B Network/Spectrum/Impedance Analyzer 1.8 GHz

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

HP 4155B/4156B Semiconductor Parameter Analyzer Product Note-3 Prober Connection Guide. HP 4155B/4156B Semiconductor Parameter Analyzer

product overview HP 8970 Series Noise Figure Measurement Products

A New Series of LCR Meters to Meet Your Applications

Agilent Accessories Selection Guide For Impedance Measurements. December 2008

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

E-series E9300 Average Power Sensor Specifications

Accessories Selection Guide For Impedance Measurements. April 2005

Advanced Test Equipment Rentals ATEC (2832)

Fundamentals of Microwave Frequency Counters. Application Note Electronic Counters Series

Agilent 4284A/4285A Precision LCR Meter Family

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

Keysight Technologies Power of Impedance Analyzer

Agilent 4285A Precision LCR Meter

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

Agilent PNA Series RF Network Analyzers

IMPEDANCE ANALYZER IM3570

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Bench LCR Meter Model 891

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent LCR Meters, Impedance Analyzers and Test Fixtures

Keysight Technologies Accessories Selection Guide For Impedance Measurements. Selection Guide

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

ProBER 2 2 Mb/s Handheld Test Set. The handheld that takes 2 Mb/s testing beyond convention

Keysight E5061B-3L3/3L4/3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function

Op Amp Booster Designs

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Agilent 970-Series Handheld Multimeters Data Sheet

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

Product Note E5100A-2

Keysight Technologies E4980A Precision LCR Meter

R3131A. Advanced Test Equipment Rentals ATEC (2832) A personal spectrum analyzer for use in diverse applications R3131A

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

Grundlagen der Impedanzmessung

Agilent 4070 Series Accurate Capacitance Characterization at the Wafer Level

EMC Accessories Catalog

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features.

ECE 6416 Low-Noise Electronics Orientation Experiment

Advanced Test Equipment Rentals ATEC (2832)

LM2462 Monolithic Triple 3 ns CRT Driver

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

Agilent 8703A Lightwave Component Analyzer Technical Specifications

khz to 2.9 GHz Spectrum Analyzer

DC Resistance Meters 2840 Series

Agilent 87075C Multiport Test Set

Agilent LCR Meters, Impedance Analyzers and Test Fixtures

Frequency up to 100 khz


Introduction to BER testing of WDM systems

SDM3045X Digital Multimeter. DataSheet

LF442 Dual Low Power JFET Input Operational Amplifier

Vector Network Analyzers ZVB

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

LM386 Low Voltage Audio Power Amplifier

Measure Low Value Impedance Current Shunt Impedance

LM117/LM317A/LM317 3-Terminal Adjustable Regulator

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

LM117HV/LM317HV 3-Terminal Adjustable Regulator

LM675 Power Operational Amplifier

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function

Low Value Impedance Measurement using the Voltage / Current Method

Low Cost, General Purpose High Speed JFET Amplifier AD825

LM2412 Monolithic Triple 2.8 ns CRT Driver

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

SDM3045X Digital Multimeter. DataSheet

SPECTRUM ANALYZERS. MS710C/D/E/F 10 khz to 23 GHz (18 to 140 GHz) GPIB SPECTRUM ANALYZER

CLC440 High Speed, Low Power, Voltage Feedback Op Amp

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent 8752C RF Vector Network Analyzer

Agilent 83440B/C/D High-Speed Lightwave Converters

Keysight E5061B-3L3/3L4/3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Agilent U8903A Audio Analyzer

LM150/LM350A/LM350 3-Amp Adjustable Regulators

Spectrum Analyzers 2680 Series Features & benefits

Features. Applications SOT-23-5

LM6118/LM6218 Fast Settling Dual Operational Amplifiers

Transcription:

profile HP 4294A Precision Impedance Analyzer H New Generation Precision Impedance Analyzer for functionality and efficiency in engineering 40 Hz to 110 MHz 1

HP 4294A Precision Impedance Analyzer, NEW FEATURES The HP 4294A Precision Impedance Analyzer greatly supports accurate impedance measurement and analysis of a wide variety of electronic devices (components and circuits) as well as electronic and non-electronic material. Accurate measurement over wide impedance range and wide frequency range. Powerful impedance analysis functions. Ease of use and versatile PC connectivity. 8.5 inch TFT color display Powerful analysis tools available. 801 sweep points, 4 traces (2 data traces and 2 memory traces), 8 markers, marker analysis functions, and equivalent circuit analysis function. User-friendly interface Based on HP's widely accepted user-interface. Rigid fixture/accessory connection Provides highly repeatable and reliable measurements. HP IBASIC programming function Automatic setup, measurement and computation as well as remote instrument control is possible. Built-in 10Mbyte nonvolatile memory Data or setup files can be quickly saved or recalled. Impedance measurement ports Four-Terminal-pair measurement configuration and the newest auto-balancing bridge technique enable high accuracy and wide impedance range. 3.5 inch floppy disk drive Screen images, data and setup files can be easily saved, recalled, and shared (1.44Mbyte). Two digital I/O ports Control other instrument(s) or use an external controller (instrument or computer) via 8bit or 24bit programmable I/O port. External VGA Output Display measurements on a large VGA monitor. Reduces eyestrain, improves team work and communication. LAN Interface (10 Base-T) Another instrument control method or simplified file sharing. External keyboard Interface Makes HP IBASIC program development easier (mini DIN keyboard). Printer (Centronics) Interface Connects PCL3 printers directly to the instrument. HP-IB Interface Automatic measurement system is easily configured with an external instrument or computer. 2

40 Hz to 110 MHz The HP 4294A is a powerful tool for design, qualification, quality control, and production testing of electronic components. Circuit designers and developers can also benefit from the performance/functionality offered. Moreover, the HP 4294A's high measurement performance and capable functionality delivers a powerful tool to circuit design and development as well as materials research and development (both electronic and non-electronic materials) environments. HP 4294A Key Specifications The following are application examples: Electronic Devices: Passive component: Impedance measurement of two terminal components such as capacitors, inductors, ferrite beads, resistors, transformers, crystal/ceramic resonators, multi-chip modules or array/network components. Semiconductor components: C-V characteristic analysis of Varactor Diodes Parasitic analysis of a diode, transistor, or IC package terminal/leads. Amplifier input/output impedance measurement. Other components: Impedance evaluation of printed circuit boards, relays, switches, cables, batteries, etc. Materials: Dielectric material: Permittivity and loss tangent evaluation of plastics, ceramics, printed circuit boards and other dielectric materials. Magnetic material: Permeability and loss tangent evaluation of ferrite, amorphous and other magnetic materials. Semiconductor material: Permittivity, conductivity and C-V characterization of semiconductor materials. Operating Frequency: 40Hz to 110MHz, 1mHz resolution Basic Impedance Accuracy: ±0.08% Q Accuracy: ±3% (typical) @ Q=100, 10MHz Impedance Range: 3mΩ to 500MΩ ( 1) Measurement Time: 3 m sec / point @ f 500kHz, BW = 1 (Fast) Number of points per sweep: 2 to 801 points Measurement Type: 4 terminal pair measurement (Standard) APC-7 One port measurement with HP 42942A (Measurable grounded devices ) Impedance probe measurement with HP 42941A (Measurable grounded devices ) Impedance Parameters: Z, Y, θ, R, X, G, B, L, C, D, Q DC Bias: 0 to±40 V / 100 ma, 1mV / 40 µa resolution Constant voltage / constant current mode, DC bias V/I monitor function OSC Level: 5 mv to 1 Vrms / 200 µa to 20 marms OSC level V/I monitor function Sweep Parameter: Frequency, OSC level (V/I), DC bias (V/I) Sweep Type: Linear, Log, List : Manual sweep mode : Up/Down sweep Other Function: Equivalent circuit analysis function, Limit line function Trace accumulate mode Marker: 8 markers (one main marker and 7 sub markers) Delta marker function, Marker search function (Max, Min, Peak, Next peak etc.) Marker analysis function (*1) 30% typical accuracy range: 3mΩ (100 Hz to 110MHz), 500MΩ (100Hz to 200kHz) 3

Accurate, real-world characterization of electronic components There is no ideal inductor (L), capacitor(c), or resistor(r). In reality, operating conditions such as signal level and frequency determine the realworld performance of a device based on the electronic characteristics of the device. An ideal component of high quality could be considered to posses a single, perfect circuit element over some frequency range. However, in reality, most components will resonate as shown in these figures as the frequency increases. This is due to the fact that there are both capacitive and inductive elements present in real world components. Component characteristics cannot be expressed correctly with a two-element model when the model contains only one single reactive element. The HP 4294A equivalent circuit function enables modeling of the impedance vs. frequency characteristics with three or four elements. This function helps you design quality circuits and effective components. Equivalent Circuit Analysis: The equivalent circuit function is used to fit a circuit model to measured data, or to simulate device performance based on the value of each circuit model element. 1 After taking a measurement, The HP 4294A has been programmed with five equivalent circuit models to choose from. This function automatically extracts equivalent circuit parameters from actual measurement data. The characteristics of the device under test (DUT) or the material under 2 select an appropriate circuit model test (MUT) can be analyzed with extracted model element values. NOTE: The simulation result and the actual measurement data can be displayed on the same screen. 4 Then compare the simulation to the actual measurement data. If the data does not match, select a different equivalent circuit model and try again. 3 and extract the circuit model parameters. 4

State-of-the-art technology for improved measurement performance The HP 4294A employs a state-of-the-art auto-balancing-bridge technique in a fourterminal-pair (4TP) measurement configuration. Meticulous circuit design against distortion and instability resulted in a highly accurate and stable measurement system for a wide impedance range. For evaluation of low-loss devices: With the trend toward lower power consumption and compact equipment, inductors and capacitors are becoming smaller with lower loss. The efficiency improvement in 1 Ω power conversion for switching power supply applications is an example. These applications require low-loss inductors and capacitors. Q accuracy % 100% 90% 80% 70% 60% 50% Q=500 40% 30% Q=300 20% 10% Q=100 0% 100 1k 10k 100k 1M 10M 110M Frequency (Hz) HP 4294A Q accuracy (typical) OSC level = 250mV 1m Ω Low-loss capacitor ESR (Equivalent Series Resistance) measurement (100µF ceramic C) Q 200 High Q inductor measurement (Low-loss) For evaluating devices with wide impedance range A wide impedance range is required to accurately measure both resonant impedance and anti-resonant impedance of crystal/ceramic resonators. 6 Ω 3M Ω Crystal resonator impedance measurement The HP 4294A covering several decades (m Ω to hundreds of M Ω) of impedance can measure resonator characteristics accurately. SMD capacitor impedance measurement (using the HP 42942A) 1G Ω 3.3pF 56pF 470pF 4700pF 0.047µF 10m Ω The dynamic range of the HP 4294A in terms of impedance is more than 200dB. When compared to that of a general network analyzer with a directional bridge, at 80dB, it is clear, the HP 4294A has an extremely broad impedancemeasurement range. Impedance Ω 1G 100M 10M 1M 100k 10k 1k 100 10 1 100m 10m 1m 100 1k 10k 100k 1M 10M110M Frequency (Hz) Impedance measurement range (typical) 30% 10% 10% 30% 5

Impedance Analysis under Various Operating Conditions Signal level dependency: DC level dependency: Efficient analysis with the list sweep function Signal level dependency of a ceramic capacitor with high permittivity (signal-level swept from 5mV to 1V, 0.1 µf capacitor at 1kHz) The impedance characteristics of some devices change drastically as a function of the signal level. The HP 4294A can sweep test signal voltage, 5mVrms to 1Vrms(1mV resolution), or test signal current 200µArms to 20µArms(20µA resolution) to evaluate signal level dependency. Varactor diode capacitance vs. DC voltage characteristic. DC bias sweep from 0V DC to 5V DC. f=1mhz The DC component of an applied signal often affects device impedance. The HP 4294A can sweep either the DC voltage bias from -40V to +40V (with 1mV resolution) or the DC current bias from -100mA to +100mA (with 40µA resolution) to evaluate DC signal dependency. This capability also empowers analysis of the DC-voltage bias dependency for C-V characterization of varactor diodes or other DC-voltage bias dependent devices. The DC level dependency figure shows an example of varactor diode measurement. The DC Bias Auto Level Control (ALC) function, based on a feedback loop technique, accurately maintains the applied DC voltage bias or current bias. While the impedance of a device might change during a sweep, this ALC function insures that the signal level setting is the actual signal level applied to the DUT. The list sweep function enables different measurement setups in a single sweep by dividing the sweep range into segments. The measurement setup, including the frequency range, averaging time, measurment bandwidth, test signal level (V or A), and DC bias can be different for each segment. The frequency range of each segment can be continuous, separated or overlapped. Evaluation of a crystal resonator requires that the nominal resonant frequency, the nominal anti-resonant frequency and some spurious frequencies be determined. These parameters can be efficiently measured by setting an appropriate frequency range for each segment. 6

Powerful functions for Efficient Evaluation Sweep, Display and Markers Trace Statistics Average, standard deviation and peak of each trace. Up Sweep / Down Sweep Control the sweep direction. Sweep frequency, test signal level, or DC bias from lower to higher or higher to lower value. Scale Log or Linear Manual Sweep function Iterative measurements at a user designated point. After measuring the overall performance of a device within a wide range, you can evaluate the characteristic at a specific point. Marker functions Peak search, Next Peak search, Max/ Min search, bandwidth search, and other marker Sweep type Log, Linear or List Superimpose Trace (Accumulate) mode This mode is used to observe an intermittent event or a change in the characteristic performance of a device over time. DC Bias / Test Signal Level Monitor Accurate reading of the DC Bias or test signal level. 3 multi-trace modes for comparison evaluation Ceramic resonator measurement List Sweep mode Superimpose and compare measurement data on the same display by setting the list sweep segments to the same frequency range with different DC Bias or test signal levels. Markers can be used on each trace. 7 sub markers Measurement and frequency data are displayed as sub marker softkey labels. Data/Memory trace A data trace and a memory trace are available at each channel. The underlying data can be saved as the memory trace. Some simple calculations are possible with Data Math functions. Accumulation of resonance vs. temperature data for a ceramic capacitor Capacitance variations of ceramic capacitor (2.2µF) with high permittivity measured by stepping the test signal level from 0.1V to 0.9V in 0.2V step (five list sweep segments). Inductor DC dependency characteristics (100µH inductor at 100kHz) UP and DOWN DC current bias sweep from -100mA to +100mA Hysteresis is observed. 7

Easy, automatic measurement system configurations Labs today often require system configurations in which test instruments interact with other instruments or handshake with external computers. HP 4294A functions that support efficient systems: HP Instrument BASIC programming function for automatic measurement or external measurement instrument control without an external computer. List Sweep function for measuring only at desired points. Limit line function for Go/No- Go testing. Built-in 10Mbyte non-volatile memory for quickly save/recall data/setup. Two types programmable digital I/O port (24bit and 8 bit) for data transfer with external device such as sensor, and for external device control. LAN interface for networking with computers. The LAN I/F dramatically expands the ability to share files, data, or instrument control. Measurement setup, result, and graphics files can be transferred via FTP (File Transfer Protocol) to or from the instrument. Limit Test Limit test of PIN diode impedance. 4 segment list sweep with different DC bias voltages and different frequency ranges using constant DC bias voltage (ALC) mode. Handler, Switch, Sensor... PC Internet 8 bit I/O LAN HP 4294A Interfaces 24bit I/O Other instruments Temperature oven... HP 4294A Keyboard HP-IB External display VGA output Printer Parallel (Centronics) interface A Feature with high visibility HP IBASIC programming function HP Instrument BASIC (HP IBASIC) is a programming language developed from HP BASIC programming language. The keystroke recording function helps to easily develop automatic measurement program with front panel keys. When a key is pressed, the HP-IB command corresponding to the key is automatically recorded in the program. Writing or editing programs the old fashioned way is made easier with the mini-din keyboard. One touch HP IBASIC program execution When you press the softkey with the file name of an IBA- SIC program saved in either internal memory or floppy disk, the program is automatically downloaded and executed. Once customized IBASIC programs are developed, quick measurement and data analysis is possible because each program works as if it is a built-in function. The HP 4294A has VGA output on the rear panel. Automatic test or component adjustment in production line or QA test can easily be performed with a large external monitor. 8

Accessories for various measurement needs HP 42941A Impedance probe The HP 42941A Impedance Probe enables in-circuit impedance measurement of electronic circuits or components. Grounded devices can also be measured. Key specification: Frequency: 40Hz - 110 MHz DC BIAS: 0 to ± 40 V Operation temperature range: -20 to 75 C Basic Impedance Accuracy: ±0.8% HP 42942A Terminal Adapter: The HP 42942A Terminal Adapter converts the four-terminal-pair port configuration to an APC-7 port. This adapter permits the use of familiar APC-7 (7mm) test fixtures. Material Test Fixtures: Use of a dielectric material fixture such as the HP 16451B or the HP 16452A allows accurate dielectric material measurement. Permeability of magnetic materials can also be evaluated with the HP 42942A and HP 16454A magnetic material test fixture. Automatic measurement and permittivity/permeability analysis can easily be performed by using built-in IBASIC or by I/O to a computer where the analysis can be performed. Other accessories: When a DUT cannot be positioned near the instrument, a 4TP extension (HP 16048G: 1m or HP 16048H: 2m) can be used to extend the test station to the Again, grounded measurement is available. Key specification: Frequency: 40Hz - 110 MHz DC Bias: 0 to ± 40 V Operation temperature range: 0 to 40 C Basic Impedance accuracy: ±0.6% DUT. These HP extension accessories operate over the entire frequency and temperature range (40 Hz to 110 MHz, -20 C to +150 C) of the HP 4294A. 9

Ordering Information: HP 4294A Precision Impedance Analyzer Accessories Included: 100Ω Load Resistor for Four- Terminal-Pair Extension Mini DIN Keyboard for HP IBASIC Sample Program Disk Operation Manual Power Cable Options: 1A2 Delete Mini DIN Keyboard 1D5 High-stability Frequency Reference ABA English Localization UK6 Commercial Calibration Certificate with test data 1CM Rack Mount Kit 1CN Front Handle Kit 1CP Rack Mount and Front Handle Kit Accessories Available: Four-terminal-pair test leads (HP 16048G / HP 16048H): 1m/2m four-terminal-pair port extension cable with BNC connectors. Frequency: 40Hz - 110 MHz DC Bias: 0 ± 40 V Operation Temperature range: -20 to 150 C Cable length: 1m (HP 16048G) 2m (HP 16048H) Accessories Available: HP 42941A Impedance Probe kit Convert four-terminal-pairs port configuration to a one port probe. Furnished items: Impedance Probe with 1.5m cable Short reference 50Ω reference BNC Adapter Ground lead Clip lead Three spare pins Operation manual and spec ification sheet HP 42942A Terminal Adapter Converts four-terminal-pair port configuration to an APC-7 port. Items Included: APC-7 Open reference APC-7 Short reference APC-7 50Ω reference Operation manual/specification sheet Option: 001 Delete Open/Short/50Ω references 10

Fixtures Fixtures for leaded components HP 16047E (DC - 110 MHz) For leaded components. This fixture features the capability to clamp the leads between the electrodes and adjust the pressure. A guard terminal is provided for three port device measurements. Accessories Provided: Shorting Plate HP 4294A Mounting Tool HP 16047A/D (DC - 3MHz/40MHz) For leaded components. These fixtures use spring actuated clamps to hold device leads. HP 16093A/B (DC-250MHz) This is a binding post type fixture. Notes: The HP 42942A adapter is required. Fixtures for SMD components HP 16034G 0201 (0603) to 1206 (3216) size components. Maximum dimensions: 5mm(L) x 1.6mm (W) x1.6mm(h) HP 16092A (DC - 500MHz) For leaded or surface mount (SMD) components. Attachments for leaded or SMD components are provided. Notes: The HP 42942A adapter is required. HP 16191A/16193A (DC - 2GHz) These fixtures use surface electrode contacts, where the HP16191A is for 0805 (2012) size components or larger, and the HP16193 is for 0603 (1608) to 1206 (3216) size components. Notes: The HP 42942A adapter is required. HP 16034E (DC - 40MHz) 0603 (1608) or larger size components can be measured. Maximum dimensions: 8mm(L) x 10mm(W) x 8mm(H) HP 16092A (DC - 500MHz) For leaded or surface mount (SMD) components. Attachments for leaded or SMD components are provided. Notes: The HP 42942A adapter is required. HP 16044A (DC - 10MHz) Features a Kelvin Connection suitable for low impedance measurement of 0603 (1608) size components or larger. Maximum dimensions: 8mm(L) x 8mm(W) x 3mm(H) HP 16192A (DC - 2GHz) This fixture uses side electrode contacts 0603 (1608) or larger size components. Notes: The HP 42942A adapter is required. 11

H 40 Hz to 110 Mhz Material Test Fixtures: HP 16451B A dielectric material test fixture, with parallel plate electrodes. HP 16452A (20Hz - 30MHz) Liquid test fixture. HP 16454A (1MHz-1.8GHz) Fixture for troidal magnetic material. Notes: The HP 42942A adapter is required. (Please refer to the accessories selection guide for more details of fixtures and accessories.) For more information about Hewlett-Packard Test and Measurement products, applications, services, and for a current sales office listing, visit our web site, http://www.hp.com/go/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative. United States: Hewlett-Packard Company Test and Measurement Call Center P.O. Box 4026 Englewood, CO 80155-4026 1 800 452 4844 Canada: Hewlett-Packard Canada Ltd. 5150 Spectrum Way Mississauga, Ontario L4W 5G1 (905) 206 4725 Europe: Hewlett-Packard European Marketing Centre P.O. Box 999 1180 AZ Amstelveen The Netherlands (31 20) 547 9900 Japan: Hewlett-Packard Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192, Japan Tel: (81) 426 56 7832 Fax: (81) 426 56 7840 Latin America: Hewlett-Packard Latin American Region Headquarters 5200 Blue Lagoon Drive, 9th Floor Miami, Florida 33126, U.S.A. Tel: (305) 267-4245 (305) 267-4220 Fax: (305) 267-4288 Special Purpose Accessories: HP 16065A (50Hz - 2MHz) External DC bias adapter to +/- 200V. Notes: For leaded components. Australia/New Zealand: Hewlett-Packard Australia Ltd. 31-41 Joseph Street Blackburn, Victoria 3130, Australia 1 800 629 485 Asia Pacific: Hewlett-Packard Asia Pacific Ltd. 17-21/F Shell Tower, Times Square, 1 Matheson Street, Causeway Bay, Hong Kong Tel: (852) 2599 7777 Fax: (852) 2506 9285 Data subject to change Copyright 1999 Hewlett-Packard Company Printed in U.S.A. 03/99 5968-3808E 12