Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

Similar documents
Fast fault location in medium-voltage cable and overhead line networks siemens.com/short-circuit-indicator

Overcurrent Protection / 7SJ45

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

SWT 3000 Teleprotection technical data siemens.com

Audio/video, Information and Communication Technology Equipment - Part 1:

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

CP-T range Benefits and advantages

Technical recommendation for the purchase of Real Time Thermal Rating for transformers

CP-T range Product group picture

CP-E range Benefits and advantages

Test Specification for Type Approval

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Transformer differential protection

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Harmonic restraint earth fault or single-phase overcurrent protection

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

Power supply CP-E 24/2.5

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Accutech AP10. Wireless absolute pressure field unit

Power supply CP-E 24/20.0

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Primary switch mode power supplies Product group picture

Stabilized Differential Relay SPAD 346. Product Guide

Rosemount 702 Discrete Input Transmitter

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

The Rosemount 848T Wireless Temperature Transmitter

RS Pro ENGLISH. Datasheet

Accutech FL10. Wireless float level field unit

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

Product Specification sheet

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Power supply CP-T 24/20.0 Primary switch mode power supply

Three-phase monitoring relay CM-PFS

OPSJ1900 J1900 Open Pluggable Specification Products

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

02/11/2015

em4 em4 alert em4 alert 2G

Accutech AM20. Wireless acoustic monitor field unit

Time over/underfrequency relay with protection assemblies

satech SynchroStar GPS 200 Series

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

MB120S 120W Single Output Medical Series

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Wind Turbine Analysis System - Type 3652 MKII & MKIII

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Power supply CP-E 24/0.75

em4 local - Robust Specific characteristics Part number

Power supply CP-T 48/5.0 Primary switch mode power supply

CP 6632 Handheld process signal calibrator

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Power supply CP-T 24/10.0 Primary switch mode power supply

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Accutech DP20. Wireless differential pressure field unit

FOUNDATION Fieldbus Junction Box

Electronic timer CT-MFS.21

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RS Pro ENGLISH. Datasheet

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

TB65 65W Single Output Test and Measurement/Industrial Series

SAMSUNG ELECTRO-MECHANICS CO., LTD

IRIG-B Interface (De-modulated) External clock synchronization signal IRIG format B00X

BIODEX MULTI- JOINT SYSTEM

Appendix A: Specifications

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RE17LLBM asymmetrical flashing relay s V AC - solid state output

High precision measurement system for current and voltage IHC-A/B-RM01/03

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Power supply CP-T 48/20.0 Primary switch mode power supply

LineTroll 110Eµr. User Manual. LINETROLL 110E /110Eµr User Guide February 2010 Page 1 of 16

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Doc. EA Model Number:

02/11/2015

02/11/2015

P3801 LOW DISTORTION LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. V.90 and V.92 modems V.34 modems

Pressure transmitter AKS 32 and AKS 33

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Power supply CP-T 24/40.0 Primary switch mode power supply

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Transcription:

Digital Grid Products SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

SICAM Fault Sensor Indicator (FSI) System Diagram of FSI and FCG Description SICAM Fault Sensor Indicator (FSI) 6MD2314 detects the phase-to-phase (short circuit) fault and phase-to-earth fault on the MV overhead line network. The device indicates both the temporary fault and permanent fault via an optical indication. SICAM FSI (6MD2314) device is developed using the latest generation of hardware technology and is a member of the Siemens SICAM short-circuit indicator product family. SICAM FSI is used to improve the distribution grid reliability and reduce the power outages on the MV overhead line. SICAM FSI can be mounted (in groups of 3 or 6 or 9) on each phase after the branching points and sectionalizer. The device is available in 2 variants: 6MD2314-1AB10 Stand-alone The faults are signaled directly from the device by LEDs. Depending on the fault type, a specific flashing sequence is generated. 6MD2314-1AB11 with communication In addition to local LED display, Phase-to-phase fault and phase-to- earth fault are transferred to SICAM Fault Collector Gateway (FCG) via a secured short-range radio communication. SICAM FCG communicates to a higher-level control center using the IEC 60870-5-104 protocol or via XMPP over a GPRS network. Features The salient features of SICAM FSI are: Higher availability of overhead line networks - Quick fault detection and localization, reduced downtime. Self sustained - Equipped to harvest power from the over headline enhancing service life of the device (Battery life of 10 years for stand-alone variant and 8 years for communicable variant). Secure - Protection against unauthorized access. Authentication and encryption via AES 128, shared keys. Maintenance free - Robust design with IP65 and UV resistant housing. Simple configuration - Easy device configuration with QR code on SICAM FSI and via a web browser. High Sensitivity - Measurement starting from 50 A. System Diagram of SICAM FSI and SICAM FSI with Control Center SICAM FSI is configurable in coordination with upstream protection system (settings like permanent-fault verification time and auto reclosure time). The communicable variant of SICAM FSI uses the short-range radio for transmitting the fault information instantaneously to the control center via SICAM FCG. The fault indication can also be reset remotely from the control center. The fault parameters and other settings are remotely configurable. Applications SICAM FSI works in the MV overhead distribution line that ranges from 3.3 kv to 66 kv, 50 Hz/60 Hz networks. SICAM FSI Configuration Stand-alone Variant Before installing the stand-alone variant of SICAM FSI on the MV overhead line, configure the basic parameters and advanced device parameters and apply the device settings by using the SICAM FSI configurator. Communicable Variant Before commissioning the SICAM FSI and SICAM FCG, configure the SICAM FSI QR code in the SICAM FCG configuration page. After the configuration, the secure communication channel between SICAM FSI and SICAM FCG is established. For more information about SICAM FCG and SICAM FSI commissioning, refer to E50417-H1040-C584-A1, SICAM FCG Manual. Laptop computer UART cable 1.0 m SICAM FSI Connection using UART cable Siemens Limited 1

Technical Data For full technical data, refer to the technical specification section of the user manual. Application Data Rated voltage (Vrated) 3.3 kv to 66 kv Power frequency 50 Hz/60 Hz Conductor diameter 5 mm to 25 mm Measurement cycle 20 ms (For 50 Hz) period 16.6 ms (For 60 Hz) Voltage presence (%) 0.70 of Vrated Voltage absence (%) 0.45 of Vrated Rated current (Irated) 50 A up to 500 A (steps of 50 A) Current measurement 10 % from 50 A to 800 A accuracy Power source Energy harvesting + lithium - thionyl chloride battery Total Fault indication 400 hours of LED flashing time NOTE: Energy harvesting starts if the line current exceeds 60 A. Fault Detection Parameters di current 5 A to 80 A (steps of 5 A), 120 A, 160 A Current threshold 1.5 Irated to 3 Irated (steps of 0.5) Fault-indication time 2 h to 16 h (steps of 0.5 h) Inrush restraint time 3 s, 30 s, and 60 s Permanent fault 3 s, 35 s, and 70 s verification time Auto reclosure time 0.1 s to 99.9 s Communication Communication mode Short-range radio, Frequency band 2440 MHz (IEEE 802.15.4) NOTE: The communication mode is applicable for the communicable variant of SICAM FSI (6MD2314-1AB11). Reset (Permanent Faults) Voltage restoration reset Vrated > 70 % Manual reset Using magnetic adapter Remote reset Via SICAM FCG (From control center) Fault Indication Indication Luminous flux Visibility angle Visibility range Bright red LEDs 40 lumens 360 (from ground level) 50 m day time, 300 m night time Mechanical Weight Dimensions Indication of Conformity 0.7 kg 116 mm dia x 193 mm height This product complies with the directive of the Council of the European Communities on harmonization of the laws of the Member States relating to electromagnetic compatibility (EMC Council Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low Voltage Directive 2006/95/EC). This conformity has been proved by tests conducted by Siemens AG in accordance of the Council Directive in accordance with the product standard IEC/EN 61326-1 for the EMC directives, and with the standard IEC/EN 61010-1 for the low-voltage directive. WPC certification is performed as per R&TTE directive. Standards for short-range radio and mobile communication acc. to R&TTE directive: EMC testing acc. to EN 301489-1 Short-range radio (spurious emission) acc. to EN 300 328 The device has been designed and produced for industrial use. Type Testing This section describes about the type testing performed on SICAM FSI. Electrical Tests Dielectric withstand EN 61010-1 125 kv Short-circuit current withstanding test IEEE 495 12.5 ka @ 1 s 25 ka @ 170 ms EMC Tests for Immunity (Type Tests) Electrostatic discharge, Level 3 Radiated Radio frequency electromagnetic field, Level 3 Power frequency magnetic field, Level 4 EN 301 489-1, EN 301 489-3, IEC 61000-4-2 EN 301 489-1, EN 301 489-3, IEC 61000-4-3 IEC 61000-4-8 8 kv air discharge and 4 kv contact discharge 80 MHz to 2.7 GHz (10 V/m, criteria A) 30 A/m (continuous) and 300 A/m (short time) on the X, Y, and Z axis of the product Siemens Limited 2

EMC Tests for Noise Emission (Type Tests) Radiated emission test, Class A Safety Testing Test EN 301 489-1, EN 301 489-3, EN 55011 Standards Safety test IEC/EN 61010-1 Test Description Marking and Documentation Protection against mechanical hazard Resistance to mechanical stresses (shock and impact) Protection against the spread of fire Protection against liberated gases and substances, explosion and implosion Components and sub assemblies HAZARDS resulting from application 150 khz to 6 GHz (class A) Applicable Clause No. 5 7 8 9 13 14 16 Risk Assessment 17 Environmental Tests Operating Temperature Dry cold test IEC 60068-2-1-25 C (4 days) Dry heat test (4 days) IEC 60068-2-2 +70 C IEC 60068-2-78 25 C to 40 C; Damp heat steady 95% RH (4 days) Damp heat cyclic (6 days) IEC 60068-2-30 25 C to 40 C; 95% RH (6 cycles with 12 h + 12 h) IEC 60068-2-48-25 C to 70 C Rainfall - 750 mm Exposure to direct sunlight (UV) ASTM G155 Wind resistance - 200 km per hour Salt spray test ASTM B117 Ingress protection IEC 60529 IP65 Mechanical Tests Test Vibration response test, Class 1 Bump test Short-Range Radio Testing Standards IEC 60068-2-6 Storage temperature IEC60068-2- 27/ IEC60068-2-29 Tests Requirements Sinusoidal Frequency: 10 Hz to 500 Hz Displacement: 0.7 mm peak to peak from 10 Hz to 59 Hz Amplitude: 5 g from 59 Hz to 500 Hz Sweep rate: 1 oct./min Number of sweeps: 01/axis Number of axes: 3 (X, Y, and Z) Acceleration: 40 g Duration: 6 ms Number of sweeps: 2000 positive and 2000 negative shocks Number of axes: 3 (X, Y, and Z) Transmitter unwanted emissions in the spurious domain and receiver spurious emissions Spurious emission EN 300 328 Operating frequency range: 2400 MHz to 2480 MHz No. of channel: 16 Modulation: Other than FHSS (DSSS) Channel Spacing: 5 MHz Optical Tests Lumens test LM79 40 lumens Goniometry test LM79 360 visibility Siemens Limited 3

Ordering Information - Device Use the following MLFB series to order the SICAM FSI (stand-alone and communicable) devices: 6MD2314-1AB10 6MD2314-1AB11* Stand-alone variant - Fault current up to 1500 A, di/dt detection, UV stabilized polycarbonate, IP65, visual fault indication by 6 high luminous LEDs of 40 lumens. Communicable variant - Short-range radio communication for current measurement values and fault status, fault current up to 1500 A, di/dt detection, UV stabilized polycarbonate, IP65, visual fault indication by 6 high luminous LEDs of 40 lumens. * The Communicable variant of SICAM FSI must be associated with SICAM FCG (6MD2340-3JM70-8AA2). Ordering Information - Spares Use the following MLFB series to order the SICAM FSI spares: 6MD2318-4BB00 Lithium-thionyl chloride battery (non-rechargeable) Ordering Information - Accessories Use the following MLFB series to order the SICAM FSI accessories: UART cable for the device configuration 6MD2318-4AA00 6MD2318-4MA01 Hot stick with shotgun fitted for FSI mounting, 4 m Hot stick (telescopic) for FSI mounting, 12 m 6MD2318-4MA02 Magnetic reset assembly, accessory for hot stick with shotgun fitted 6MD2318-4MA04 6MD2318-4MA05 Device adapter for SICAM FSI mounting via hot stick (telescopic), accessory for hot stick (telescopic) Siemens Limited 4

Case Dimensions Fig 4. Front View Fig 6. Side View Fig 5. Isometric View Fig 7. Top View Siemens Limited 5

E50417-K1040-C587-A1 For any technical queries, please contact our customer support center Phone: +49 (180) 524-7000 Fax: +49 (180) 524-2471 E-Mail: support.energy@siemens.com. Siemens Limited 6