PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Similar documents
PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 3AC/24DC/10

QUINT-PS AC/24DC/40

QUINT-PS-24DC/24DC/10

QUINT-PS/ 3AC/24DC/40

MINI-PS AC/24DC/1.3

MINI-PS AC/2X15DC/1

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

TRIO-PS-2G/1AC/24DC/5

QUINT-PS/1AC/24DC/10. Power supply unit. Data sheet. 1 Description

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

CP-T range Product group picture

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/20.0 Primary switch mode power supply

CP-T range Benefits and advantages

Power supply CP-D 24/1.3

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 12/2.1

PHOENIX CONTACT - 09/2009

CP-E range Benefits and advantages

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

MINI MCR-SL-UI-f(-SP)

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Primary switch mode power supplies Product group picture

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Switching power supplies CP range, Linear power supplies CP-L range. Content

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

PHOENIX CONTACT

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

Electronic timer CT-TGD.22

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

PHOENIX CONTACT

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

For Immediate Delivery call KMParts.com at (866)

MINI MCR-SL-UI-I-LP-NC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Power Supplies 3. SDN-C Compact DIN Rail Series

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-SDD.22

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Transformers, Power Supply Units and Socket Outlets

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Smart Power Relay E I...

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relays

INTERFACE. User Manual

Electronic Circuit Breaker with reset input ESS20-1..

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Electronic timer CT-SDS.22

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Installation / Monitoring Technique

XUA1 - AC Voltage and phase balance relay

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

MACX MCR-UI-UI-UP(-SP)(-NC)

Liquid level monitoring relay CM-ENS.2x

Electronic Circuit Protector ESX10-T

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Transcription:

Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability due to SFB technology Compact power supply units of the new QUINT POWER generation maximize the availability of your system. Even the standard power circuit-breakers can be tripped reliably and quickly with the SFB technology (Selective Fusebreaking Technology) and six times the nominal current for 12 ms. Defective current paths are disconnected selectively, the defect is limited and the important system parts remain in operation. A comprehensive diagnostics is carried out by continuously monitoring the output voltage and current. This preventive function monitoring visualizes the critical operating modes and reports them to the control unit before an error occurs. Quick tripping of standard power circuit breakers with dynamic SFB technology power reserve Reliable starting of difficult loads with static POWER BOOST power reserve Preventive function monitoring Can be used worldwide High degree of operational safety due to high MTBF > 500 000 h, long mains buffering times > 20 ms, high dielectric strength up to 300 V AC DANGER OF EXPOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. DANGER Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf.

2 Table of contents 1 Description...1 2 Table of contents...2 3 Order data...3 4 Technical data...3 5 Structure...6 6 Block diagram...7 7 Safety and warning notes...7 8 Installation...8 9 Installation position...8 Slim-style installation...9 ow-profile installation...9 10 Connection to various network forms... 10 11 Input... 10 Protection of the primary side...10 Recommended backup fuse for mains protection...10 12 Output... 11 Protection of the secondary side...11 13 Signaling... 11 Floating contact...12 Active signal outputs...12 Signal loop...12 14 Function... 13 Output characteristic curve...13 Thermal behavior...13 Parallel operation...14 Redundant operation...14 Increased performance...14 103129_en_01 PHOENIX CONTACT 2

3 Order data Description Type Order No. Pcs./Pkt. Primary-switched power supply with SFB technology, 1 AC, output current 20 A QUINT-PS/1AC/24DC/20 2866776 1 Accessories Type Order No. Pcs./Pkt. Assembly adapter for QUINT POWER 2.5 A and 5 A on S7-300 rail QUINT-PS-ADAPTERS7/1 2938196 1 Universal wall adapter UWA 182/52 2938235 1 4 Technical data Input data Input nominal voltage range AC input voltage range Short-term input voltage DC input voltage range AC frequency range DC frequency range Current consumption Inrush current limitation I 2 t 100 V AC... 240 V AC 85 V AC... 264 V AC 300 V AC 90 V DC... 350 V DC 45 Hz... 65 Hz 0 Hz Approx. 5.1 A (120 V AC) Approx. 2.3 A (230 V AC) < 20 A (typical) < 3.2 A 2 s Power failure bypass > 20 ms (for 120 V AC) > 20 ms (for 230 V AC) Typical response time < 0.5 s Protective circuitry Transient surge protection Varistor Input fuse, integrated 12 A (slow-blow, internal) Recommended backup fuse for mains protection 10 A (characteristic B) 16 A (characteristic B) Discharge current to PE < 3.5 ma Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage 18 V DC... 29.5 V DC (> 24 V constant capacity) Output current 20 A (-25 C... 70 C) 26 A (with POWER BOOST, < 40 C permanent) 120 A (with SFB technology, 12 ms) Derating From 60 C 2.5% per Kelvin Control deviation < 1 % (change in load, static 10%... 90%) < 2 % (change in load, dynamic 10%... 90%) < 0.1 % (change in input voltage ±10%) Power loss nominal load max. 46 W Maximum power dissipation idling 10 W Efficiency > 93 % (for 230 V AC and nominal values) Ascent time < 0.5 ms Residual ripple < 80 mv PP (with nominal values) Connection in parallel Yes, for redundancy and increased capacity Connection in series Surge protection against internal surge voltages Resistance to reverse feed Yes Yes, limited to approx. 35 V DC Max. 35 V DC 103129_en_01 PHOENIX CONTACT 3

Signal output active Output description Voltage Current Status display Signal output floating Output description Voltage Current Status display Signal output POWER BOOST, active Output description Voltage Current Status display U OUT > 0.9 x U N : High signal 24 V DC 1 A (short circuit resistant) "" ED green / U OUT < 0.9 x U N : ED flashing Relay contact, U OUT > 0.9 x U N : Contact closed 30 V AC/DC 1 A "" ED green / U OUT < 0.9 x U N : ED flashing I OUT < I N : High signal 24 V DC 1 A (short circuit resistant) ED "BOOST", yellow / I OUT > I N : ED on General data Insulation voltage input/output 4 kv AC (type test) 2 kv AC (routine test) Insulation voltage input / PE 3.5 kv AC (type test) 2 kv AC (routine test) Insulation voltage output / PE 500 V DC (routine test) Degree of protection IP20 Class of protection I, with PE connection MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Housing version Steel sheet, zinc-plated Dimensions W / H / D (state of delivery) 90 mm / 130 mm / 125 mm Dimensions W / H / D (90 turned) 122 mm / 130 mm / 93 mm Weight 1.7 kg Ambient conditions Ambient temperature (operation) -25 C... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units IEC 61558-2-17 Electrical safety (of information technology equipment) IEC 60950/VDE 0805 (SEV) Electronic equipment for use in electrical power installations EN 50178/VDE 0160 SEV IEC 60950 (SEV) and EN 60204 (PEV) Safe isolation DIN VDE 0100-410 Protection against electric shock DIN 57100-410 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment 103129_en_01 PHOENIX CONTACT 4

Standards (Continued) imitation of mains harmonic currents EN 61000-3-2 Device safety GS (tested safety) Network variants (undervoltage) Semi F47-200 Certificate CB Scheme Approvals U rating U isted U 508 U/C-U Recognized U 60950 Conformance with EMC directive 89/336/EEC Immunity to interference in acc. with EN 61000-6-2 Discharge of static electricity Electromagnetic HF field Fast transients (burst) Surge current loads (Surge) Conducted interference Voltage dips Housing evel 4 Contact discharge 8 kv Discharge in air 15 kv Comments Criterion B Housing evel 4 Frequency range 80 MHz... 1000 MHz Field intensity 20 V/m Comments Criterion A Input Output Signal Comments Input Output Signal Comments Input/Output/Signal Frequency range Voltage Comments Input Comments 4 kv (level 4 - asymmetrical) 2 kv (level 1 - asymmetrical) 1 kv (level 1 - asymmetrical) Criterion B 4 kv (inst. class 4 - asymmetrical: conductor to ground) 2 kv (inst. class 4 -symmetrical: conductor to conductor) 2 kv (level 3 - asymmetrical: conductor to ground) 1 kv (level 1 - symmetrical: conductor to conductor) 1 kv (level 3 - asymmetrical: conductor to ground) Criterion B evel 3 - asymmetrical 0.15 MHz... 80 MHz 10 V Criterion A (mains buffering > 20 ms) Criterion B Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential 103129_en_01 PHOENIX CONTACT 5

5 Structure 5 4 Signal DC OK?<? N 9 1 AC input 2 DC output 3 Active POWER BOOST switching output 4 output active 5 output, floating 6 Potentiometer 18 V DC... 29.5 V DC 7 "" ED 8 "BOOST" ED 9 Universal DIN rail adapter UTA 107/30 3 QUINT POWER Boost Input AC 100-240 V 18-29,5 V 1 2 Output DC 24V 20 A - - - 6 7 8 [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-6 0.2-4 18-10 0.5-0.6 Output 0.2-6 0.2-4 12-10 0.5-0.6 Signal 0.2-6 0.2-4 18-10 0.5-0.6 Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC DC input voltage range 90 V DC... 350 V DC AC frequency range 45 Hz... 65 Hz DC frequency range 0 Hz Input fuse, integrated 12 A (slow-blow, internal) Recommended backup fuse for mains protection 10 A (characteristic B) 16 A (characteristic B) Type of connection Screw connection Stripping length 7 mm Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage Output current Type of connection Stripping length 18 V DC... 29.5 V DC (> 24 V constant capacity) 20 A (-25 C... 70 C) 26 A (with POWER BOOST, < 40 C permanent) 120 A (with SFB technology, 12 ms) COMBICON screw/plug connection 7 mm 103129_en_01 PHOENIX CONTACT 6

6 Block diagram () N (-) active PFC PE I<I N 13 14 7 Safety and warning notes The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. DANGER OF EXPOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. DANGER Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! The device can be disconnected outside the power supply unit in accordance with the regulations as in EN 60950 (e.g. through primary side line protection)! The ground conductor is connected! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! 103129_en_01 PHOENIX CONTACT 7

DC OK Ι< Ι N QUINT-PS/1AC/24DC/20 8 Installation Signal DC OK?<? N In order to guarantee sufficient convection, we recommend observing the following minimum distance to other modules: 5 cm in the vertical direction and 0.5 cm in the horizontal direction. A lateral distance of 5 mm, and in case of active components, that of 15 mm is necessary for proper functioning of the module. Depending on the ambient temperature and the load of the module, the housing can become very hot! QUINT POWER Input AC 100-240 V Boost 18-29,5 V The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be horizontal (connecting terminal blocks above and below). Output DC 24 V 20 A - - - 9 Installation position 5 90 5 122 115 50 Signal Boost 230 QUINT POWER 18-29,5 V 130 Input AC 100-240 V Output DC 24V 20 A - - - Slim-style installation: Installation depth 125 mm ( DIN rail) (state at delivery) ow-profile installation: Installation depth 90 mm ( DIN rail) 103129_en_01 PHOENIX CONTACT 8

A B Slim-style installation Assembly: Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing: Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. A B ow-profile installation ow-profile installation can be achieved by mounting the device at right-angles to the DIN rail. Mount the DIN rail adapter (UTA 107/30) as described in the figure. No additional mounting material is required. Fixing screws: Torx T10 (torque 0.8 Nm... 0.9 Nm). 103129_en_01 PHOENIX CONTACT 9

10 Connection to various network forms TN-S TN-C TT it N PE PEN PEN 1 2(N) 1 2 3 N PE 1 2 3 PEN 1 2 3 N 1 2 3 The 100... 240 V AC connection is established using the, N and PE screw connections. The device can be connected to 1-phase AC networks or to two of the phase conductors of three-phase systems (TN, TT or it systems in acc. with VDE 0100-300/IEC 60364-3) with nominal voltages of 100 V AC... 240 V AC. For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided. 11 Input Protection of the primary side The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. QUINT POWER Input AC 100-240 V Signal DC OK Output DC 24V 20 A?<? N Boost 18-29,5 V - - - Recommended backup fuse for mains protection Power circuit breaker 10 A or 16 A, characteristic B (or identical function). In DC applications, a suitable fuse must be wired in upstream. If an internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! 103129_en_01 PHOENIX CONTACT 10

12 Output Make sure that all output lines are dimensioned according to the maximum output current or are separately protected. The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. QUINT POWER Signal DC OK?<? N Boost 18-29,5 V The connection is established using screw connections on the screw connection of the DC output: 24 V DC: "" and " "; switching output active: "" and " "; output floating: "13" and "14"; POWER BOOST switching output active: "I < I N " and " ". At the time of delivery, the output voltage is 24 V DC. The output voltage can be set on the potentiometer. Input AC 100-240 V Output DC 24V 20 A - - - Protection of the secondary side The device is electronically protected against short circuit and idling. In the event of a malfunction, the output voltage is limited to 35 V DC. 13 Signaling The active signal output, the floating signal contact and the active POWER BOOST switching output are provided for function monitoring. The -ED and the BOOST-ED also enable the function evaluation of the power supply unit directly on the operation site (refer to the output characteristic curve). I < I N I > I N U OUT < 0.9 x U N "" ED ON ON Flashing "BOOST" ED OFF ON ON Active switching output ON ON OFF Floating output Closed Closed Open Active POWER BOOST switching output ON OFF OFF Meaning Normal operation of the power supply (U OUT >21.5V) POWER BOOST operation, e.g. to start loads Overload mode, e.g. consumer short circuit or overload 103129_en_01 PHOENIX CONTACT 11

Output 24 V DC - - - Floating contact The floating signal contact opens and signalizes a drop in the output voltage as set of more than 10%. Signals and ohmic loads of up to 30 V and currents of up to 1 A can be connected. For heavily inductive loads such as a relay, a suitable protection circuit (e.g. damping diode) is necessary. max. 30 V AC/DC 1A 24VDC 1A Output 24 V DC - - - Active signal outputs The 24 V DC signal is applied between the "" and the "-" connecting terminal blocks or between "I < I N " and "-" and can carry up to 1 ma. By switching from "active high" to "low", the signal output signalizes when the output voltage is more than 10% below the output voltage. The signal is decoupled from the power output. It is thus not possible for parallel switched devices to provide external supply. The 24 V DC signal can be directly connected to a logic input for evaluation. The POWER BOOST signal output signalizes that the nominal current is exceeded. Signal loop 1 2 Output 24 V DC - - - Output 24 V DC - - - Monitoring two devices: Use the active signal output of device 1 and loop in the floating signal output of device 2. In the event of malfunctioning, a common alarm is output. Any number of devices can be looped in. This signal combination saves wiring costs and logic inputs. 103129_en_01 PHOENIX CONTACT 12

14 Function Output characteristic curve The power supply unit operates with the static POWER BOOST power reserve as per the U/I characteristic curve given in the figure. In case of ambient temperatures T amb <40 C, I BOOST is available permanently; it is available only for a few minutes in case of higher temperatures. In the event of a secondary short circuit and overload, the output current is limited to I BOOST. Thereby, the module does not switch off, but supplies a continuous output current. The secondary voltage is reduced until the short circuit has been remedied. The U/I characteristic curve with the POWER BOOST power reserve ensures that high inrush currents of capacitive loads and of consumers with DC/DC converters in the input circuit can be fed reliably. In order to trip the standard power circuit breakers magnetically and thus very quickly, QUINT POWER supplies six times the nominal current for 12 ms with the help of the SFB technology. The defective current path is switched off using this dynamic power reserve; consumers connected in parallel continue to operate without an interruption. The error is thus restricted and the important system parts continue to operate. The characteristic curve shows when I < I N, I > I N and U<0.9xU N. The relevant signaling is given in the table. U N = 24 V I N = 20 A I BOOST = 26 A SFB technology = 120 A P N = 480 W P BOOST = 625 W U [V] OUT U N I<I N I N I>I N U<0,9xU N I BOOST I OUT [A] Thermal behavior Output current [A] I N 0 0 20 40 60 Ambient temperature [ C] With an ambient temperature of up to 40 C, the device supplies the continuous output current of I BOOST. The device can supply a nominal output current of I N with ambient temperatures of up to 60 C. In the case of ambient temperatures above 60 C, the output current must be reduced by 2.5% per Kelvin increase in temperature. The device does not switch off at ambient temperatures of 70 C or thermal overload. The output capacity is reduced as far as necessary to provide device protection. After it has cooled down, the output capacity is increased again. 103129_en_01 PHOENIX CONTACT 13

Parallel operation Devices of the same type can be connected in parallel to enable both redundancy and an increase in efficiency. No other alignment is necessary when in the state of delivery. If the output voltage is adjusted, a uniform distribution of power is guaranteed by setting all parallel operated power supply units to exactly the same output voltage. To ensure symmetrical distribution of power, we recommend designing all cable connections from the power supply unit to a busbar of the same length and with the same conductor cross section. The system makes it advisable to install a protective circuit at the output of each device when more than two power supply units are connected in parallel (e.g. decoupling diode or DC fuse). This prevents high reverse feed currents in the event of a secondary device fault. Redundant operation I N I N Σ =I N Redundant circuits are suitable for the supply of systems which make especially high requirements on the operational safety. If a fault occurs in the primary circuit of the first power supply unit, the second device automatically takes over the entire power supply, without interruption, and vice versa. For this reason, the power supply units to be connected in parallel are dimensioned in such a way that the total current requirement of all consumers can be completely covered by one power supply unit. 100% redundancy makes external decoupling diodes necessary (QUINT-DIODE/40, Order No. 2938963)! I N I N Increased performance For n parallel connected devices, the output current can be increased to n x I N. Parallel connection to increase efficiency is used for the expansion of existing systems. It is advisable to use parallel connection if the power supply unit does not cover the current requirement of the most powerful consumer. Otherwise the consumers should be spread among individual devices independent of one another. A maximum of five devices can be connected in parallel! Σ =2xI N 103129_en_01 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: 49-(0) 5235-3-00 14 PHOENIX CONTACT P.O.Box 4100 Harrisburg PA 17111-0100 USA Phone: 717-944-1300 www.phoenixcontact.com