UNDERSTANDING SUB-HARMONICS

Similar documents
Protection for Sub SSTI Conditions Using an Industrial Sub-harmonic Relay

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

A Comprehensive Approach for Sub-Synchronous Resonance Screening Analysis Using Frequency scanning Technique

Sub-synchronous Electrical Torque Frequencies Monitoring before the SSR Presence.

ANALYSIS OF A FLASHOVER OPERATION ON TWO 138KV TRANSMISSION LINES

PHYSICAL PHENOMENA EXISTING IN THE TURBOGENERATOR DURING FAULTY SYNCHRONIZATION WITH INVERSE PHASE SEQUENCE*

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Analyzing the Impact of Shunt Reactor Switching Operations Based on DFR Monitoring System

THE EFFECTS OF NEUTRAL SHIFTS ON PROTECTIVE RELAYS. Authors: Joe Perez P.E., SynchroGrid, College Station, Texas 77845

Mitigation & Protection of Sub-Synchronous Controller Interactions (SSCI) in DFIG Wind Turbine Systems

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Wind and Solar (PV) Sub harmonic Interactions with Power Systems

Commissioning Process and Acceptance Test of a Sub-harmonic Protection Relay

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Voltage and Current Waveforms Enhancement using Harmonic Filters

SYNCHRONOUS MACHINES

A New Subsynchronous Oscillation (SSO) Relay for Renewable Generation and Series Compensated Transmission Systems

Grid Impact of Neutral Blocking for GIC Protection:

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

ABB Inc. April 1, 2016 Slide 1

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

TECHNICAL BULLETIN 004a Ferroresonance

Power Quality Analysis in Power System with Non Linear Load

BAKISS HIYANA BT ABU BAKAR JKE,POLISAS

Ferroresonance Experience in UK: Simulations and Measurements

Planners Perspective on Series Compensated Transmission Lines

A NEW MONITORING SPECTRAL TECHNIQUE FOR SUB- SYNCHRONOUS ELECTRICAL TORQUE FREQUENCIES

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Sizing Generators for Leading Power Factor

Beskrivelse av simuleringsmodell ==> Description of simulation model

FERRORESONANCE SIMULATION STUDIES USING EMTP

Damping of Sub synchronous Resonance Using SSSC Based PWM Hysteresis Controller

Catastrophic Relay Misoperations and Successful Relay Operation

Investigating Possible Induction Generator Effects Due to Sub-Synchronous Resonances

Effects of Harmonic Distortion I

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Conventional Paper-II-2013

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

VOLTAGE OSCILLATION TRANSIENTS CAUSED BY CAPACITOR BANKING ENERGIZING FOR POWER FACTOR CORRECTION IN THE POWER SYSTEM

PART 1 OWNER/APPLICANT INFORMATION

Analysis of Single Phase Self-Excited Induction Generator with One Winding for obtaining Constant Output Voltage

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

IOCL Electrical Engineering Technical Paper

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

ELEMENTS OF FACTS CONTROLLERS

ELG2336 Introduction to Electric Machines

ANALYSIS OF A DIFFERENTIAL AND OVERCURRENT OPERATION ON A 345KV HIGH VOLTAGE LINE REACTOR

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Design and Simulation of Passive Filter

How Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Use of a Sub Harmonic Protection Relay to Detect SSO Conditions Associated with Type-III Windfarms and Series Compensated Transmission Systems

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Impact of Harmonic Resonance and V-THD in Sohar Industrial Port C Substation

Induction Machine Test Case for the 34-Bus Test Feeder -Distribution Feeders Steady State and Dynamic Solutions

MODEL POWER SYSTEM TESTING GUIDE October 25, 2006

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Generator Protection GENERATOR CONTROL AND PROTECTION

Study of Subsynchronous Resonance in Power Systems

LOAD BEHAVIOUR DURING VOLTAGE DIPS: A VOLTAGE QUALITY STUDY IN LOW VOLTAGE DISTRIBUTION SYSTEM

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

In Class Examples (ICE)

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

Study of Inductive and Capacitive Reactance and RLC Resonance

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Physics for Scientists & Engineers 2 2 = 1 LC. Review ( ) Review (2) Review (3) e! Rt. cos "t + # ( ) q = q max. Spring Semester 2005 Lecture 30 U E

RELAY LOADABILITY CHALLENGES EXPERIENCED IN LONG LINES. Authors: Seunghwa Lee P.E., SynchroGrid, College Station, Texas 77845

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

BSNL TTA Question Paper Control Systems Specialization 2007

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Resonances in Collection Grids of Offshore Wind Farms

Conventional Paper-II-2011 Part-1A

Generator Advanced Concepts

HARMONICS CAUSES AND EFFECTS

PAPER-II (Subjective)

Placement Paper For Electrical

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

APPENDIX B: Generation Interconnection Application Form

Power System Stability. Course Notes PART-1

Analysis of Temporary Over-Voltages from Self-Excited Large Induction Motors in the Presence of Resonance - Case Studies

Artificial Island Open Window Concerns re: Dominion Proposal 1A

Improvement of Power Quality Considering Voltage Stability in Grid Connected System by FACTS Devices

Power Factor. Power Factor Correction.

Tanu Sharma al. International Journal of Recent Research Aspects ISSN: , Vol. 1, Issue 3, Dec 2014, pp

COPYRIGHTED MATERIAL. Index

Transient Analysis and Mitigation of Capacitor Bank Switching on a Standalone Wind Farm

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Transcription:

UNDERSTANDING SUB-HARMONICS Joe Perez, P.E., SynchroGrid, College Station, TX 77845, jperez@synchrogrid.com Introduction: Over the years, engineers have employed fundamental principles of electrical engineering to solve system problems. For example, series reactors are used to limit the amount of fault current since inductors resist a change in current. Similarly, series line capacitors are used to increase the amount of real power by cancelling a portion of the inductive reactance. However, some solutions can create new problems in the system as is the case with series line compensated capacitors. When a capacitor is used in a transmission line as a series element, sub-harmonic currents with frequencies below the fundamental are created. Extensive research and study have been done, and the consequences of subharmonic currents can be catastrophic. The effects of sub-harmonics were visualized back in 1971 after a synchronous generator shaft failure [3]. Since then, generator manufacturers and utilities have worked together to identify problems between the interaction of series capacitors and generators. In recent months, a couple of incidents one in Texas and another in Minnesota have been identified where sub-harmonics were implicated in creating an increased voltage and current oscillations. One common factor in these two events is that they involved wind generation. After decades of research, there are various phenomena effects that can be attributed to sub-harmonics. Sub-harmonics can create induction generator effects, torsional interactions, torque amplification, subsynchronous resonance, and transformer saturation. For the interaction between wind generation and series compensated lines, research that will help determine the real cause is still underway; however, the evidence records seem to point towards an induction generator effect phenomena. As a result, this paper provides a concrete foundation of the induction generation effect, torsional interactions and torque amplifications. Additionally, this paper provides simulations that help the reader to visualize the effect and offers a relay solution for sub-harmonics. Sub-Harmonics: It is well known that nonlinear loads will produce harmonics by drawing currents that are not necessarily sinusoidal. In effect, inductive loads will produce harmonics that are multiples of the fundamental (e.g., 120Hz, 180Hz, 240Hz, etc.) In a similar manner, when a circuit involving a resistor, capacitor and inductor is connected in series, voltages and currents with frequencies below the fundamental (e.g., 20Hz, 25Hz, 30Hz, etc.) will be created [2]. These are called sub-harmonic frequencies; they will be denoted fer. Sub-harmonics were first discussed by Butler and Concordia shown in reference [4]. Experimenting with series capacitors and transformers in series, they discovered a large, abnormal current flow that was low in frequency and had distorted the entire current waveform. In addition, the transformer secondary voltage was also distorted.

Subsequent research was performed, and the researchers discovered that the system resistance played an important role in the magnitudes of these sub-harmonic currents. It is now known that the sub-harmonic frequencies in a RLC circuit will be damped out through the resistance of the circuit and will coexist in the system without presenting major problems [5]. However, during faults or switching events the subharmonic currents are amplified and excited so that the resistance of the circuit can reach a point that is not enough to damp the sub-harmonic frequencies [6]. As a result, these frequencies can cause voltage and current amplification as explained by the induction generator effect. Induction Generator Effect: When a series capacitor is used to cancel a portion of the system reactance, the system will always end up with a natural frequency which is less than the system frequency and is referred to as the sub-harmonic [2]. This sub-harmonic frequency is defined by [1] as: fer = fo Xc (X" + Xe + Xt) (1) The generator armature sub-harmonic currents produce magnetic fields with frequency fer which are induced in the generator rotor. As a result, the induce currents in the rotor produces a rotor frequency defined as: fr = fo fer (2) As a result, this new added rotor frequencies will result in sub-synchronous armature voltages which may enhance the sub-synchronous currents and may cause generator self excitation (1). Because the rotor is turning faster than the sub-harmonic armature currents with frequency fer, a slip is created simulating an induction machine and the slip is defined by [2] as: Slip s = fer fo fer (3) As we can see from equation 3, the slip will always be negative which will result in a negative rotor resistance R as described in Figure 1. Rs Xs Xr I Xm R =Rr/s Figure 1: Induction generator effect circuit. 2

The rotor resistance is define as: R 9 = Rr s (4) Since the slip (s) will always be negative, the damping effect of R will always be negative. If the series compensation is very high, the slip (s) will be very small and therefore R will be a negative large number (6). If the addition of the damping resistance R and the resistance of the system is negative, voltage and current growing oscillations may build up to very dangerous high values. The example below helps us better understand this concept. Figure 2 shows a series compensation circuit through a couple 525kV transmission line given by reference [7]. 0.0009+j0.02 p.u 0.0014 + j0.038 p.u - j0.0268 G Generator 0.038 + j0.011 p.u IMPEDANCES IN P.U ON 100 MVA BASE 0.0002 System Load j0.006 Figure 2: Series Compensation Circuit Using equation 1 we can find the natural frequency of this circuit as follows: fer = fo Xc (X" + Xe + Xt) fer = 60 0.0268 0.075 fer = 36Hz Using equation 3 we can calculate the slip: Slip = fer fo fer 36 60 Slip = 36 3

Slip = 0.66 p. u. Using equation 4 we can calculate the damping with a rotor resistance of 0.02 p.u: R 9 = R s R 9 = 0.0038 0.66 R 9 = -0.0057 p.u The total resistance of the network of line, transformer and load is: The total effective resistance is: Rnetwork =0.002 p.u. Reff = R +Rnetwork Rnet = -0.0057+0.002 p.u. Rnet= -0.0037 p.u. Since the net resistance is negative for this series compensated circuit, we can expect increasing subharmonic oscillation Power System Model: The simulations below show the impact of the induction generator effects for the system shown in Figure 2. Figure 3: Three phase series compensated system. 4

Figure 3 shows a three phase series compensated line composed of six 350 MVA generators, a 13.8 to 735kV step-up transformer, two 300 km 735kV transmission lines, and two 68.2uf capacitors for 40% line compensation [8]. Case 1: System Response to Sub-Harmonics with Line to Ground Fault. The model takes into account the dynamics of the stator, field, and damper windings. The equivalent circuit of the model is represented in the rotor reference frame. All rotor parameters and electrical quantities are viewed from the stator. ` Figure 3: Generator and line parameters. Figure 3 shows the synchronous machine and line parameters used for this simulation. For this machine model, all the stator and rotor resistances are viewed from the stator. The rotor is modeled as round type. Since the rotor resistance is dependent on the speed of the machine as Rr/s, it is evident that the rotor resistance will vary. If the net resistance or the addition of the rotor resistance and the resistance of the network is negative, then we can expect growing oscillations. A single line-to-ground fault is applied in the transmission line. The fault lasts for 3 cycles and then goes away. Figure 4 shows the voltage and current response to the fault as seen from bus 1. It can be observed that the faulted voltage phase goes down and its respective current goes up. The voltages seem to recover to a fairly steady state condition. However, we can see that the currents do not. The shape of the currents signals the presence of other frequencies besides the fundamental. A frequency analysis tool can reveal embedded frequencies in the system. Figure 5 shows the presence of the highest subharmonic frequency at 12Hz. 5

Nevertheless, the currents seem stable, and growing oscillations are prevented. This means that the net resistance is positive and keeps the current and voltage from growing oscillations. The currents and voltages have a similar behavior at bus 2 as indicated in Figure 6. Figure 4: Line to ground fault as seen from bus 1. Figure 5: Sub-harmonic frequency at 12Hz. 6

Figure 6: Line to ground fault as seen from bus 2. Case 2: System Response to Sub-Harmonics with Three Phase to Ground Fault. For this second case, a three phase fault is applied to the first transmission line. Figure 7 shows the current and voltage responses as seen from bus 1. The voltage waveform shows a severe presence of sub-harmonic frequencies. The highest of the sub-harmonic frequencies is found at 12Hz. However, due to the three phase fault, the sub-harmonic contribution is seen in all three phases. We can see that the resistance of the system is not enough to damp out the sub-harmonics, and severe voltage growing oscillations are observed. As a result, the net resistance between the rotor resistance and system resistance becomes negative and produces a negative damping effect. An interesting observation is that the voltage magnitude reaches a value of three per unit 45 cycles after the fault inception. Such high magnitude voltage values can be avoided by an overvoltage setting. If such growing oscillations are not stopped, equipment insulation could fail catastrophically. Figure 8 shows the similar result for the voltage and currents as seen at bus 2. Figure 7: Three phase fault as seen from bus 1. 7

Figure 8: Three phase fault as seen from bus 2. Figure 9: Sub-harmonic frequency at 12Hz. The Effect of Net Resistance on Sub-Harmonics. The induction generator effect occurs when the resistance Rr/s is greater than the resistance of the system, producing a negative net resistance. As a result, the negative resistance has a negative damping effect, which produces growing oscillations. In order to prove this concept, we can increase the line resistance until the net resistance becomes positive. Figures 10 and 11 show how the growing oscillations were contained when the line resistance was increased from 0.000001273 p.u to 1.000001273 p.u. The presence of sub-harmonics is still evident, but the net resistance is positive and damped out. Figure 10: Three phase fault as seen from bus 1. 8

Figure 11: Three phase fault as seen from bus 2. Torsional Interactions and Torque Amplification The positive sequence sub-harmonic armature currents produce rotor sub-harmonic currents at frequency fr = fo-fer. So we would expect this current frequencies to be less than the system current frequency of 60Hz. For our last example, the rotor sub-harmonic frequency would be: fr = fo fer fr = 60 36 fr = 24 Hz If this rotor frequency coincides with the mechanical shaft system frequency fn which is described below, the shaft torque could be amplified due to the resonance between the electrical and mechanical natural frequencies (1). The effects of power system faults and switching in a series compensated circuit excites not only the electrical natural frequency modes or sub-harmonics but also the mechanical sub-harmonics modes. The mechanical system is modeled by 3-masses : mass 1 = generator; mass 2 = low pressure turbine (LP); mass 3 = high pressure turbine (HP).The mechanical sub-harmonic natural frequency is given by: fn = K12 M1 M2 M1 + M2 When the rotor oscillates at frequency fn, it will modulate the generator voltage at a frequency fen which is: fen = fo fn 9

When this frequency is near the fer frequency, the armature current will produce torque which can create growing oscillations (1). Figure 12 shows how the torques from the generator and low pressure turbine have been amplified to levels up to 4 p.u. due to the resonance effect. Figure 12: Generator and Low Pressure Turbine Torque due to Resonance Effect Solutions to the Sub-Harmonic Problem. Obviously, varying the system resistance is not feasible, and therefore, other forms of prevention and protection are necessary. A sub-harmonic protective relay can be used to detect the sub-harmonic frequencies and allow the relay to take corrective action. The new S-PRO relay manufactured by ERLPhase Power Technologies offers the user a comprehensive sub-harmonic solution. The S-PRO offers 5-45Hz frequency protection, under-overvoltage protection, and overcurrent protection. Figure 12 shows the relay oneline that the S-PRO offers. Figure 12: S-PRO relay oneline. 10

In addition to the relay protection, the S-PRO offers a great oscillographic program that allows the relay engineer to graph the voltages and currents along with the frequency spectrum. As a result, the engineer can quickly discover which sub-harmonic frequency is present in the system. Figures 13 and 14 shows the benefits of the oscillographic program taken from a real system event. Figure 13: Sub-harmonic currents and voltages from a real event. Figure 14: Sub-harmonic spectrum using a record graph. Biography: Joe Perez is the owner of SynchroGrid LLC. Previously, he worked as Application Engineer for the relay and digital fault recorder products of ERLPhase Power Technologies, formerly NxtPhase T&D. He previously worked as a transmission engineer and a field application engineer, gaining experience in system protection projects and transmission system studies, including fault, power flow, and contingency analysis. Joe graduated from Texas A&M University in 2003 with a BSEE and has previously presented papers at WPRC, Texas A&M and Georgia Tech Relay Conferences. Joe is a 11

registered professional engineer in the state of Texas and a member of PSRC, IEES, and PES. Joe resides in the Bryan/College Station area. He can be contacted at jperez@synchrogrid.com. References: [1] Institute of Electrical and Electronic Engineers. 1992. Reader s Guide to Subsynchronous Resonance. IE Committee Report. IEEE Transsactions on Power Systems, Vol 7, 150-157. [2] Kilgore L. A., Elliott L. C., Taylor E. R. (1971). The prediction and control of self-excited Oscillation du capacitor in power system. IEEE Transactions on Power Apparatus and Systems, PAS 90, 1305-1311. [3] Farmer R.G, Schwalb A.L. (1977). Navajo project report on subsynchronous resonance analysis and solu Transactions on Power Apparatus and Systems, 96, 1226 1232. [4] Butler J. W., Concordia C. (1956). Analysis of series capacitor application problems. Transactions of the Institute of Electrical Engineers, 56, 975 988. [5] The intuitor. Retrieved December 2011, from http://www.intuitor.com/resonance/abcres.html [6] Wadhwa C. L. (2005). Electric power systems. New Delhi, India: New Age International. [7] Ballance, J.W., Goldberg, S. (1973). Subsynchronous resonance in series compensated transmission line Transactions of the American Institute of Electrical Engineers, PAS-92, 1649 1658. [8] The MathWorks INC. (2003). SimPowerSystems. Natick, MA: Author. 12