SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

Similar documents
SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

4.25Gbps SFP Transceiver

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

2.5Gbps SFP Transceiver

OCTECH 1.25Gbps SFP Transceiver

1.25Gbps SFP Transceiver

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

OCTECH 1.25Gbps SFP Transceiver

Optical Transceiver Module - SFP

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SFP-BIDI G 1310/1490nm BIDI

PERFORMANCE SPECIFICATIONS - ELECTRICAL

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP+ BIDI Series JB1270-SFP-LC.S20

WDM SFP+ модули предназначены для создания каналов связи по одноволоконному SM кабелю на расстояние до 20км.

SFP+ Series SFP-10G-SR

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

SO-CSFP-100Base-BX20D-34-O2 -I

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

J4859C= 1000BASE-SX, jusqu à 10Kms de distance, Longueur d ondes Laser 1310nm, Fibre Monomode (SMF).

SNR-SFP+LR-2 10Gbps. Applications 10GBASE-LR at 10.31Gbps 10GBASE-LW at 9.95Gbps Other optical links

GLC-LH-SMD-SO SFP, 1G, 10km, Single Mode, 1310nm, with DOM

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

SO-SFP-1000BASE-ZXD-I

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

SFP+ Series EOLP M-I. Features. Applications. Ordering information

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

AXGE Gbps Single-mode 1310nm, SFP Transceiver

PT (2)-1W(+) GbE 1000Base-LX 10 km SFP Transceiver

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

EX-SFP-1GE-LX-A 1000Base-LX SFP Module 1310nm, 10Km, SMF, LC RoHS6

DWDM SFP+ Series DWDM EML

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

DWDM SFP Series. Laser

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

SFP Series. EOLS X Series. Features. Applications. Ordering Information

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

SO-SFP-10GE-BX10D-3327-E

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

GLC-SX-MMD-SO SFP, 1G, 550m, Multi Mode, 850nm, with DOM

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

SFP Series. EOLS-1312-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm 1.25Gbps FC/GBE Duplex SFP Transceiver RoHS Compliant

Part No. Data Rate Wavelength Interface Temp. DDMI /1.25Gbps 1310nm SC Industrial NO EOLS-BI I

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gbps CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP+ Series EOLP Features. Applications. Ordering information

3.3V / 1310 nm / 1.25 Gbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

SFP Series EOLS X. Features. Applications. Ordering Information

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

155Mbps Single-mode 1310nm, SFP Transceiver

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

SFP Series. Distance * (note2) Interface Temp. DDMI

AXFT Mbps~155Mbps Single Fiber Bi-directional SFP, ONU Transceiver

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note1) Interface Temp. DDMI.

Fiber Distance* (note2) Temp. Connector DDM

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

Fiber Distance* (note2) Interface Temperature DDMI Rate

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

SPM-3102WG / SPM-3102BWG / SPM-3102AWG (RoHS Compliant) 3.3V / 1310 nm / 125 Mbps Digital Diagnostic LC SFP MULTI-MODE TRANSCEIVER

SFP-LX 1.25Gb/s Single-Mode SFP Transceiver 1000BASE-LX Gb/s Fiber Channel

JD061A-C. 1.25Gbps SFP Transceiver

3.3V / 1550 nm / 1.25 Gbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

Part No. Data Rate Fiber Distance Interface Temperature DDMI

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

SFP Series EOLS-BI Series EOLS-BI Series

SO-SFP-10GE-LR20-I. SFP+, 10GBase-LR, 1310nm, SM, DDM, 11.4dB, 20km ind.temp. OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

3.3V / 1550 nm / 2.5 Gbps Digital Diagnostic SFP LC SINGLE-MODE TRANSCEIVER

Product Specification. SFP OLT 1G 20km SC. 1.25Gbps Upstream/1.25Gbps Downstream GE-PON OLT Transceiver. SFP OLT 1G 20km SC

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

Transcription:

Features Operating data rate up to 1.25Gbps 1310 nm FP LD Transmitter Distance up to 30km Single 3. 3V Power supply and TTL Logic Interface Duplex LC Connector Interface Hot Pluggable Operating Case Temperature Standard: 0 ~+70, Industrial:-40 ~+85 Compliant with MSA SFP Specification Digital diagnostic monitor interface Compatible with SFF-8472 Applications Gigabit Ethernet Switches and Routers Fiber Channel Switch Infrastructure XDSL Applications Metro Edge Switching Product Description The SNR-SFP-LX series single mode transceivers is small form factor pluggable module for bi-directional serial optical data communications such as Gigabit Ethernet 1000BASE-LX and Fiber Channel 1x SM-LC-L FC-PI. It is with the SFP 20-pin connector to allow hot plug capability. This module is designed for single mode fiber and operates at a nominal wavelength of 1310 nm. The transmitter section uses a multiple quantum well laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The SNR-SFP-LX series are designed to be compliant with SFF-8472 SFP Multi-source Agreement (MSA). 12/10/2009 shop.nag.ru Page 1 of 9

Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply Voltage V CC -0.5 3.6 V Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Temperature T A SNR-SFP-LX 0 +70 SNR-SFP-LXI -40 +85 Power Supply Voltage V CC 3.15 3.3 3.45 V Power Supply Current I CC 190 ma Surge Current I Surge +30 ma Baud Rate 1.25 GBaud Total Supply Current I CC 300 ma Surge Current Isurge +30 ma PERFORMANCE SPECIFICATIONS - ELECTRICAL Parameter Symbol Min. Typ. Max Unit Notes TRANSMITTER CML/PECL Inputs(Differential) Vin 400 2500 mvp AC coupled inputs Input Impedance Rin > 100 kohms @ Zin 85 100 115 ohms (Differential) DC Tx_DISABLE Input Voltage - High 2 3.45 V Tx_DISABLE Input Voltage - Low 0 0.8 V Tx_FAULT Output Io = 400µA; Host Vcc-0.5 Vcc+0.3 V Voltage -- High Vcc Tx_FAULT Output Voltage -- Low 0 0.5 V Io = -4.0mA RECEIVER CML Outputs (Differential) Vout 400 800 1200 mvpp AC coupled outputs Output Impedance (Differential) Zout 85 100 115 ohms Rx_LOS Output Voltage - High Vcc-0.5 Vcc+0.3 V C lo = 400µA; Host Vcc Rx_LOS Output 0 0.8 V lo = -4.0mA 12/10/2009 shop.nag.ru Page 2 of 9

Voltage - Low MOD_DEF ( 0:2 ) VoH 2.5 V VoL 0 0.5 V Optical and Electrical Characteristics With Serial ID Parameter Symbol Min. Typical Max. Unit 9µm Core Diameter SMF SNR-SFP-LX 20 Km Data Rate 1.25 Gbps Transmitter Centre Wavelength λ C 1260 1310 1360 nm Spectral Width (RMS) σ 3 nm Average Output Power SNR-SFP-LX P 0ut -6-1 dbm Extinction Ratio EX 9 db Rise/Fall Time(20%~80%) tr/tf 1.2 ns Total Jitter TJ 56.5 ps Output Optical Eye IUT-T G.957 Compliant Data Input Swing Differential V IN 500 2000 mv Input Differential Impedance Z IN 90 100 110 Ω TX Disable Disable 2.0 Vcc+0.3 V Enable 0 0.8 TX_Fault Fault 2.0 V CC +0.3 Normal 0 0.8 V TX_Disable Assert Time t_off 10 s Receiver Centre Wavelength λ C 1100 1600 nm Receiver Sensitivity SNR-SFP-LX PIN -22 dbm Output Differential Impedance P IN 90 100 110 Ω Data Output Swing Differential V OUT 370 2000 mv Rise/Fall Time Tr/tf 2.2 ns LOS De-Assert LOS D -25 dbm LOS Assert LOS A -40 dbm LOS High 2.0 V CC +0.3 Low 0 0.8 V 12/10/2009 shop.nag.ru Page 3 of 9

SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Num. Name FUNCTION Plug Seq. 1 VeeT Transmitter Ground 1 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable 3 4 MOD-DEF2 Module Definition 2 3 Notes 3 Note 1 Note 2, Module disables on high or open Note 3, Data line for Serial ID. 5 MOD-DEF1 Module Definition 1 3 Note 3, Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0 3 Note 3, Grounded within the module. 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 Note 4 9 VeeR Receiver Ground 1 Note 5 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD- Inv. Received Data Out 3 Note 6 12/10/2009 shop.nag.ru Page 4 of 9

13 RD+ Received Data Out 3 Note 7 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 3.3 ± 5%, Note 7 16 VccT Transmitter Power 2 3.3 ± 5%, Note 7 17 VeeT Transmitter Ground 1 Note 5 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 VeeT Transmitter Ground 1 Note 5 Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 10 K Ω resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR and VeeT may be internally connected within the SFP module. 12/10/2009 shop.nag.ru Page 5 of 9

6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mv differential (185 1000 mv single ended) when properly terminated. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 2400 mv (250 1200mV single-ended), though it is recommended that values between 500 and 1200 mv differential (250 600mV single-ended) be used for best EMI performance. 12/10/2009 shop.nag.ru Page 6 of 9

EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. The diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2h. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3 12/10/2009 shop.nag.ru Page 7 of 9

Recommend Circuit Schematic Mechanical Specifications 12/10/2009 shop.nag.ru Page 8 of 9

GUARANTEE: CONTACT: Addres: Building 118, Vonsovskogo Street 1, Yekaterinburg, Russia Tel: +7(343) 379-98-38 Fax: +7(343) 379-98-38 E-mail: info@nag.ru Online shop: http://shop.nag.ru 12/10/2009 shop.nag.ru Page 9 of 9