Supplementary information for: Paper-Based Standard Addition Assays: Quantifying Analytes via Digital Image

Similar documents
Supplementary Information for: Programmable Diagnostic Devices Made from Paper and Tape

Chem466 Lecture Notes. Spring, 2004

OPTOFLUIDIC ULTRAHIGH-THROUGHPUT DETECTION OF FLUORESCENT DROPS. Electronic Supplementary Information

S U P P O R T I N G I N F O R M A T I O N. Paper Microzone Plates. George M. Whitesides*

Determination of reagent cross-reactivity. When adding a new, candidate protein to an

Millimeter-Scale Contact Printing of Aqueous Solutions using a Stamp. Made out of Paper and Tape

Millimeter-Scale Contact Printing of Aqueous Solutions Using a Stamp Made Out of Paper and Tape

Supplementary Figures and Videos for

Dip-and-read paper-based analytical devices using distance-based detection with color screening

Electronic Supplementary Information

Supporting Information: Electron Microscopic Visualization of Protein Assemblies on Flattened DNA Origami

Title. CitationAnalyst, 141(24): Issue Date Doc URL. Rights(URL)

INSTRUMENTATION BREADBOARDING (VERSION 1.3)

Paper-Based Piezoresistive MEMS Sensors

Supplemental Information for Manuscript: Dual Colorimetric and Electrochemical Detection of Food and Waterbonre Bacteria from A Single Assay

Printing silicone-based hydrophobic barriers on paper for microfluidic assays using low-cost ink jet printers

Structural, optical, and electrical properties of phasecontrolled cesium lead iodide nanowires

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Paper-Based Piezoresistive MEMS Sensors

Supporting Information for. Electrostatic Self-Assembly of Polystyrene Microspheres. Using Chemically-Directed Contact Electrification

Supporting Information. Thread as a Matrix for Biomedical Assays

Experiment G: Introduction to Graphical Representation of Data & the Use of Excel

Appendix III Graphs in the Introductory Physics Laboratory

Assay of sodium thiosulfate and ionic impurities in sodium thiosulfate using ion chromatography

Engineering Fundamentals and Problem Solving, 6e

Digital Photometric Determination of Protein Using Biuret, Bradford and Bicinchoninic Acid Reagents

Magnetic Levitation as a Platform for Competitive Protein. Ligand Binding Assays. Supporting Information

Colour Theory Basics. Your guide to understanding colour in our industry

Pixel Response Effects on CCD Camera Gain Calibration

DATA REPOSITORY METHODS. Field counting of K-feldspar megacrysts

Electrical and Optical Tunability in All-Inorganic Halide. Perovskite Alloy Nanowires

Lab Ch 3 Chromatography of Markers & Skittles

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

Experiment 6: Paper Chromatography

UV:SPECTROPHOTOMETERS

Supporting Information:

Ion-Selective Optical Sensors: A New Look at Well- Established Techniques of Signal Acquisition

Supplementary Information. Phase-selective cation-exchange chemistry in sulfide nanowire systems

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

Quality control of microarrays

Measurement of urinary oxalate by grain sorghum leaf oxalate oxidase immobilized to affixed alkylamine glass beads

A rapid automatic analyzer and its methodology for effective bentonite content based on image recognition technology

CHM 130 Paper Chromatography

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Figure 1: Energy Distributions for light

Supporting Information for. Thin, Lightweight, Foldable Thermochromic Displays on Paper

Test 1: Example #2. Paul Avery PHY 3400 Feb. 15, Note: * indicates the correct answer.

Chapter 6 Introduction to Statistical Quality Control, 6 th Edition by Douglas C. Montgomery. Copyright (c) 2009 John Wiley & Sons, Inc.

Individually color-coded plasmonic nanoparticles for RGB analysis

Special Print Quality Problems of Ink Jet Printers

CALIBRATED SKY LUMINANCE MAPS FOR ADVANCED DAYLIGHT SIMULATION APPLICATIONS. Danube University Krems Krems, Austria

MOLD INSTRUCTION MANUAL

Using a large area CMOS APS for direct chemiluminescence detection in Western Blotting Electrophoresis

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Lab on a Chip Accepted Manuscript

Mass Variation Tests for Coating Tablets and Hard Capsules: Rational Application of Mass Variation Tests

Dissolved Oxygen Analysis

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

Product Information. Introduction

NAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships

Laser Beam Analysis Using Image Processing

Residual Bulk Image Characterization using Photon Transfer Techniques

Measurement of channel depth by using a general microscope based on depth of focus

A piece of white paper can be 1,000,000,000 times brighter in outdoor sunlight than in a moonless night.

Contents. 1. Supplementary figures Supplementary Table Supplementary Methods Supporting movie list...

Supporting Information

Experimental Procedure

Cambridge Assessment International Education Cambridge International General Certificate of Secondary Education. Published

Quantitative Analysis of Pictorial Color Image Difference

UV:SPECTROPHOTOMETERS

SPECIFICATIONS HIGHLIGHTS SUPER AURIUS ADDITIONAL SPECIFICATION BENEFITS PERFORMANCE. High Performance Scans. Derivative Spectra.

Assay development (biochemical protein-protein interaction assays)

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Unit-23 Michelson Interferometer I

Estimation of spectral response of a consumer grade digital still camera and its application for temperature measurement

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

William Reiniach 5th Year Microelectronic Engineering Student Rochester Institute of Technology

Integrated into Nanowire Waveguides

High resolution ion mobility-mass spectrometry for separation and identification of isomeric lipids

Technical Bulletin. Guide for Using BD Cytometric Bead Array (CBA) Flex Sets with the BD Accuri C6 Flow Cytometer. Introduction

SOLDER PASTE STENCIL MANUFACTURING METHODS AND THEIR IMPACT ON PRECISION AND ACCURACY

IncuCyte ZOOM Fluorescent Processing Overview

Please refer to the figure on the following page which shows the relationship between sound fields.

Chemiluminescence- and Fluorescence-Imager Celvin S

Photometric Colorimetry

MOLD INSTRUCTION MANUAL

Developed by BioDiscovery, Inc. DualChip evaluation software User Manual Version 1.1

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Investigation of Physical Characteristics of Bread by Processing Digital Images (machine vision)

Content Spectrophotometers

Color Management and Your Workflow. monaco

Everything you always wanted to know about flat-fielding but were afraid to ask*

Reference Manual SPECTRUM. Signal Processing for Experimental Chemistry Teaching and Research / University of Maryland

Comparative Analysis of RGB and HSV Color Models in Extracting Color Features of Green Dye Solutions

Ultra-Low Power Analog Sensor Module for Sulfur Dioxide

Lab 9 Photosynthesis. Background. Chromatography. Light Absorption

The Correspondence with Beer s Law for the Optical Density of Stained Protein Patterns on Filter Paper as a Function of Surface Protein Concentration

TECHNICAL INFORMATION Hungarian Red Catalog Nos. LV503, LV5031

Electronic Supplementary Information

Transcription:

Supplementary information for: Paper-Based Standard Addition Assays: Quantifying Analytes via Digital Image Colorimetry under Various Lighting Conditions Cory A. Chaplan, ǂ Haydn T. Mitchell ǂ and Andres W. Martinez* Department of Chemistry & Biochemistry, California Polytechnic State University, San Luis Obispo, CA 93401 ǂ These authors contributed equally to this project. * Corresponding author E-mail: awmartin@calpoly.edu

Table S1. Comparison of results from the standard addition assays and the external calibration assays for three different lighting conditions. All results are reported as the mean ± standard deviation for three trials. The external calibration curve generated from the scanner data was used to calculate the external calibration concentrations for all three lighting conditions. Standard Addition, mm External Calibration, mm Sample Scanner Outdoor Camera Indoor Camera Scanner Outdoor Camera Indoor Camera 0 mm -0.02±0.04 0.07±0.03 0.10±0.07-0.02±0.03 0.03±0.02 0.03±0.02 1.25 mm 1.3±0.3 1.4±0.3 1.33±0.08 1.31±0.09 0.79±0.04 0.43±0.01 2.50 mm 2.4±0.3 2.2±0.2 2.1±0.4 2.5±0.1 1.20±0.05 0.58±0.03 5.00 mm 4.9±0.3 5.4±0.9 5.2±0.8 5.4±0.5 2.01±0.01 0.91±0.03 Art. Urine (2.50 mm) 2.2±0.3 2.5±0.5 2.2±0.3 2.58±0.07 2.0±0.1 0.84±0.04 Unknown (2.50 mm) 2.5±0.3 2.3±0.5 2.1±0.6 2.8±0.2 1.24±0.03 0.63±0.06 EXPERIMENTAL DESIGN In order to develop the standard addition assay for glucose, we made three improvements over previously published paper-based glucose assays: (i) we optimized the reagents for the assay in order to achieve more uniform distributions of color in the test zones, (ii) we introduced the use of colored wax barriers to minimize signal interference from the background, and (iii) we introduced the use of a rectangular hyperbolic equation with two parameters for improved external calibration curve fitting for colorimetric paper-based assays. Previous work with paper-based colorimetric assays used quadratic fits and logarithmic fits for the external calibration curves of colorimetric assays with moderate succes. 1,2 The rectangular hyperbolic equation provides excellent fits to plots of signal versus concentration for paper-based colorimetric assays and allows for non-linear standard addition assays to be performed. 2

Device design and fabrication The device consisted of a central sample zone from which the sample was distributed through eight channels (spokes) into eight test zones arranged uniformly around the sample zone (Figure 1). We chose to pattern the device by wax printing since this method is simple, rapid, and the patterns can be printed in a variety of colors. 3 The length and width of the spokes were optimized to contain 0.7 μl of solution. The size of the test zones was optimized to store the reagents for the assay and provide a sufficiently large area so that the signal of the assay could be imaged and measured easily. The device was designed to run four replicates of sample (S 0 ) and four replicates of sample spiked with a known concentration of glucose (S 1 ). For the spiked replicates, a known concentration of glucose was added to the spokes and dried during fabrication of the device. Choice of glucose assay Initial experiments were conducted using a reagent mixture containing glucose oxidase, horseradish peroxidase and potassium iodide, but the brown triiodide produced by the assay tended to concentrate around the rim of the test zone and led to large indeterminate errors (Figure S1). By replacing the potassium iodide with 2,2 -azinobis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS), a much more uniform color distribution in the test zone was obtained. 3

Figure S1. Figure S1. Optimization of the reagents and devices for detection of glucose. (A) Original devices using iodide and black wax barriers. The color generated by the assay accumulated around the edges of the test zones. (B) Inverted red channel of the image shown in (A). The black wax barriers contribute a significant signal, which interferes with the signal of the results. (C) Optimized devices using ABTS and red wax barriers. The distribution of the color generated by the assay is more uniform in the test zones. (D) Inverted red channel of the image shown in (C). The red wax barriers are virtually invisible making it easier to measure the signal from the assay. 4

Choice of wax barrier color We chose to pattern the hydrophobic barriers in the device using red wax because we found this color interfered the least with signal from the assay (Figure S1). Since the ABTS produced a blue-green color, we found that the best signal to noise ratio could be obtained by splitting the image into its red, green and blue channels in ImageJ, and measuring the intensity of the color in the red channel. The red wax generated much less signal in the red channel compared to black, blue or yellow wax. Choice of lighting conditions To demonstrate the capability of the standard addition assay to provide quantitative results that were independent of lighting conditions, the devices were imaged under three different lighting conditions: (i) scanner with an LED light source, (ii) digital camera outdoors in sunlight and (iii) digital camera indoors under fluorescent lighting. The scanner provided uniform and reproducible lighting conditions for imaging. Both the outdoor and indoor lighting conditions varied throughout the day. The devices were imaged on a sunny day around noon, and the devices and camera were arranged in order to minimize the presence of shadows in the image. Data analysis and calculations The intensity of the color generated in the test zones was read using ImageJ by inverting the image (to obtain the negative), splitting it into the red, green and blue channels and analyzing the red channel (Figure S1). Our initial experiments focused on preparing external calibration curves by plotting signal versus concentration for a series of known glucose standard solutions and attempting a number of different curve fitting equations. It was only after attending a mock lecture from a biochemistry job candidate 5

that we realized that the signal versus concentration plot of our colorimetric assay for glucose had a similar shape to the curves observed in enzyme kinetics experiments as described by the Michaelis-Menten equation. 4,5 sa rectangular hyperbolic equation was then used to derive an expression for the non-linear standard addition assay for glucose. EXPERIMENTAL DETAILS The devices were designed in CleWin and the colors of the barriers were adjusted in Adobe Illustrator. The patterns were printed onto Whatman No. 1 chromatography paper using a Xerox Phaser 8560 printer. The paper was baked in an MTI Corporation Compact Forced Air Convection Oven for 2 minutes at 195 C and then cooled to room temperature under ambient conditions. All eight test zones were spotted with 0.7 μl of a reaction mixture consisting of 25-mM ABTS, 75-kU L -1 glucose oxidase, 250-kU L -1 horseradish peroxidase and 1-M trehalose dissolved in 1xPBS. The spokes for the test zones labeled S 1 were spotted with 0.7 μl of a 5-mM glucose solution prepared in 1xPBS. All reagents were allowed to dry under ambient conditions for 15 minutes. The assays were run by adding 35 μl of sample solution to the sample zone while the device was held horizontally. The results were imaged using an EPSON Perfection V300 scanner and a Nikon D5100 camera after 30 minutes. The images were opened in ImageJ and split into red, green and blue channels. The red channel was inverted, and the mean intensity of each test zone was measured by selecting the entire circular area of the test zone. The intensity of the sample zone was also measured and subtracted from 6

the signal of the test zones as background. Outliers were rejected using Grubb s test at a significance level of α=0.05. 6 An external calibration curve was prepared by running seven devices with glucose concentrations of 0, 0.625, 1.25, 2.50, 5.00, 7.50, and 10.0 mm, all prepared in 1xPBS. No glucose was added to the spokes of the calibration devices. The calibration curve for each lighting condition was fit with Equation 4 using KaleidaGraph in order to obtain values for S max and K. Four spoke-calibration devices were prepared to determine the magnitude of C s. A 5-mM glucose solution was added to all eight spokes of the calibration devices, and the devices were run with 0, 0.125, 2.50 and 5.00-mM glucose samples respectively. The determined glucose concentrations from the test zones were plotted versus the known concentrations of the glucose samples, and the data was fit with a linear function. The x-intercept of the resulting equation was taken as the value of C s. Standard addition assays were performed in triplicate using a series of known samples with concentrations of 0, 1.25, 2.50 and 5.00-mM glucose. A simulated urine sample containing 2.50-mM glucose and 5-mM Tartrazine, a yellow dye, in 1xPBS was also tested. Finally an unknown sample, which also contained 2.50-mM glucose, was tested via a blind experiment where the assay and data analysis were performed blind to the unknown s true glucose concentration. All chemicals were purchased from commercial sources and unaltered from factory composition before use: Fisher Scientific 10xPBS Solution, Acros Organics D- (+)-Trehalose Dihydrate (99%), Sigma Aldrich D-(+)-Glucose Anhydrous, Sigma Aldrich Horseradish Peroxidase Type VI, Sigma Aldrich Glucose Oxidase, Alpha Aesar ABTS (98%). 7

REFERENCES 1. A.W. Martinez, S.T. Phillips, E. Carrilho, S.W. Thomas, H. Sindi and G. M. Whitesides, Anal. Chem., 2008, 80, 3699 3707. 2. K.C. Schilling, A.L. Lepore, J.A. Kurian and A.W. Martinez, Anal. Chem., 2012, 84, 1579-1585. 3. E. Carrilho, A.W. Martinez and G. M. Whitesides, Anal. Chem., 2009, 81, 7091 7095. 4. L. Michaelis and M. L. Menten, Biochem. Z., 1913, 49, 333-369. 5. L. Michaelis, M. Menten, K.A. Johnson and R.S. Goody, Biochemistry, 2011, 50, 8264-8269. 6. D. Harvey, Analytical Chemistry 2.0; David Harvey, 2008, published online at http://www.asdlib.org/onlinearticles/ecourseware/welcome.html 8