015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH-ARE3 & AH-ASE3 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com info@purelighting.com General Information Fixture must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. Not for use in wood or tile ceilings. Fig.1 Complete Fixture 6 1/16" (154mm) HOUSING ANCHOR SCREENS WORKFLOW CHART 1. Locate and mount housing. Screw and lock-in housing 3. Connect wires in housing 5 7/8" (149mm) 18 1/" (470mm) 8 7/8" (5mm) 1 1/8" (307mm) PLASTER PLATE CONTRACTOR 1. Install and cut drywall around housing. ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP. 1. Adjust plaster flange frame and tighten wing nuts.. Connect the MR16 and LEDS wiring to the plaster plate. 3. Screw plaster plate into housing. 4. Test MR16 and LEDs. CONTRACTOR 1. Plaster, sand & paint.. Clean aperture with clean damp towel. TILT GEAR Fig. Pan tilt Mechanism attached to inside of plaster plate. BACK LIGHT SHIELD HOT AIMING WITH PHILLIPS SCREWDRIVER PAN LOCK PAN ROTATION RING 1. Clean aperture with clean damp towel, where the drywall contractor missed.. Adjust pan rotation ring and aim lamp. You're done! Important Scan with your mobile device to watch the installation video or visit www.purelighting.com/auror a-install Importante Escanear con el dispositivo móvil para ver el video de instalación o visite www.purelighting.com/auror a-install HOT AIMING TILT SCREW Fig.3 Snoot Assembly LIGHT SPILL SHIELD 5 BULLET CATCHES SNOOT RETAINING RING LOCKING RING (INCLUDED) MR16 HALOGEN LAMP ONLY LOCKING RING (INCLUDED) SOFT FOCUS LENS (INCLUDED) LENS (OPTIONAL) LOUVER (OPTIONAL) SNOOT LAMP HOLDER 1
A ANCHOR SCREENS 1 5 7/8" (149mm) 14 3/4" (375mm) 8 7/8" (6mm) ALIGNMENT NOTCH B NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. (NOT CENTER IN FIXTURE) NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. ALIGNMENT NOTCH 1 1/8" (308mm) MUST BE FLUSH WITH JOIST 1: Use these dimensions when locating the center point of the aperture during the installation process. Align the fixture using a laser or a chalk line. NOTE: Drywall anchor screens may be removed, if the joist are less than 14 1/" apart. Refer to page 8 to shorten the hanger bars, : Hanger bars must align and remain flush with joist. C D 4 REMODEL NOTE: CUT TO MIDDLE OF JOIST. 3 3: After fixture is positioned, tighten all (10) screws on hanger bars. 4: After installation, pull on fixture to ensure there is no movement.
E LINE INPUT 10V - 40V INSIDE AURORA JUNCTION BOX (NOT TO SCALE) - Neutral TO NEXT FIXTURE + Dimmable Switchleg *NOTE* Leave 1" of wire in the junction box for future maintenance through the f ixture aperture. Make sure the wire nut connections are tight. MAGNETIC LOW VOLTAGE DIMMER INSIDE AURORA FIXTURE 10V 75W MAGNETIC TRANSFORMER (40V ELECTRONIC TRANSFORMER FOR EUROPE) MR16 LAMP WIRING DIAGRAM FOR USE WITH PURE LIGHTING AURORA NON-RGB FIXTURES 3
CONTRACTOR F Contratista hojas de pared tiene que instalar la hoja de pared y corte un aqujero 14 3/4" (375mm) X 1 1/8" (308mm) con une corte rotatorio alrededor el enseres fijo o lo corte un agujero antes que instalar. G ANCHOR SCREEN CUTOUT 5 6 ROTARY TOOL 5: Drywall contractor must install drywall and cut 14 3/4" (375mm) X 1 1/8" (308mm) hole with rotary cutting tool around fixture or pre-cut hole in drywall prior to ANCHOR SCREW 6: Electrian must anchor drywall anchor screens. Insert screws through drywall into anchor screen on fixture. H I CEILING 7 PLASTER FLANGE FRAME LOOSEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 8 7: Loosen (4) wing nuts and adjust plaster flange frame to be flush with drywall. All 4 corners MUST be exactly even with drywall. Plaster flange frame adjusts to accommodate 1/" (13mm) to 1 1/4" (3mm) ceiling 8: Use a straight edge or level and move plaster flange frame up or down to be exactly even with drywall ceiling. 4
J TIGHTEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 9 K LED QUICK CONNECTOR 9 USE A PEN TO TIGHTEN LOCKING RINGS. 10 LAMP LOCKING RING LOUVER AND LENS LOCKING RING SNOOT LAMP HOLDER 9: Tighten (4) wing nuts securely. 10: Assemble lamp holder fixture to MR16 socket. Use a pen to tighten locking rings into place. L M 11 1 11: Loosely attach plaster plate using all (4) screws. After all (4) screws are started, go back and tighten the screws securely. 1: Check to ensure that the plaster plate is flush and even with the drywall. 5
N O 15 MAKE SURE ALL LEDS ARE WORKING. MR16 HALOGEN ACCENT LIGHT (NO MR16 LED) MAKE SURE ALL LEDS ARE WORKING. 14 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 13: Turn on and test MR16 and LEDs to ensure they are properly installed. 14: To aim lamp, loosen pan lock, rotate and position the pan rotation ring. P Q OPEN SPACE ON RACK 16 GEAR COVER 15 17 18 TOP CLIP HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 15: Tilt and rotate MR16 as needed. When lamp is properly adjusted secure pan lock. BOTTOM CLIP 16: Measure the distance of the open space on the track. 17: Remove the protective film from the gear cover. 18: Cut the gear cover to fit the space if necessary. 6
R 1 19 APERTURE S CONTRACTOR Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. RACK GEAR COVER GEAR COVER RACK 0 Aplicar incluido Perfect Finish FibaTape Ultra-Thin Tape alrededer de los cuatro lados 19: Insert the gear cover (make sure the gear cover clips are facing the lamp assembly rack) from the bottom of the aperture. : Apply included Perfect Finish FibaTape Ultra-Thin Drywall Tape around all four sides of the plaster plate. DO NOT OVERLAP. 0: Secure by snapping in the two bottom clips of the gear cover first to the bottom edge, then snap in the top two clips to the top edge. T U 4 3 Aplique una capa delgada de Durabond 45 compuesto alrededor de todo cuatro lados de la placa de yeso Lijar superficie de yeso. Repita según sea necesario hasta que la superficie es totalmente lisa antes de pintar. 3: Apply a thin layer of Durabond 45 compound around all four sides of the plaster plate. 4: Sand plastered surface. Repeat as needed until surface is completely smooth before painting. 7
V W 7 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 5: Paint and finish plaster plate and wall. Remove paint shield from plaster plate 0-60 minutes after painting. 7 6: Clean all excess paint from the aperture. 7: Wash hands and clean all drywall residue from inside aperture, with a clean damp towel. Electrician or lighting designer - ensure pan rotation ring is adjusted, locked in place, and the lamp is aimed properly. SHORTENING THE HANGER BAR (ONLY FOR JOISTS SPACED LESS THAN 14.5") X HOUSING Y HOUSING HANGER ARM HANGER ARM 1 1 1 1 HANGER ARM 3 ANCHOR SCREEN 3 PHILLIPS SCREW 1: Remove the four Phillip screws on the housing to remove the two anchor screens, and put the screws back on. : Pull the hanger arms completely out of the housing. 3: Break the ends completely off hanger arms. 8
Z HOUSING HANGER ARM 4 4 4: Insert the hanger arms back into the housing, and continue to step A on page to complete instillation. 9