Current Probe Fixture Instruction Manual

Similar documents
Bulk Current Injection Probe Test Procedure

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

AK-18G Antenna Kit Operation Manual

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

SAS-551 Passive Monopole Antenna Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

TDS-535 Tuned Dipole Set Operation Manual

SAS-543 Biconical Antenna Operation Manual

SAS Log Periodic Antenna Operation Manual

Current Probes. User Manual

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

Model 3106 Double-Ridged Waveguide Horn

Model 3116 Double-Ridged Waveguide Horn

Model 3110B Biconical Antenna

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

FISCHER CUSTOM COMMUNICATIONS, INC.

860 DSP & 860 DSPi Multifunction Interactive Cable Analyzer. Section VI: Appendix

Instruction Manual Model M Switch, DPDT, Manual Select

MODEL 3810/2 Line Impedance Stabilization Network

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Glass Electrode Meter

PI-10 Broadband Power Indicator

SureCall TM CM800 65dB

Model BiConiLog Antenna. User Manual

80i-600A AC Current Probe

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Model 3148 & Log-Periodic Dipole Array Antenna

PI-150 Broadband Power Indicator

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Log Periodic Dipole Array Antenna

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

SPM-50 RF Spectrum Power Meter PC Software User Manual

Model 9305 Fast Preamplifier Operating and Service Manual

Inline Antenna Signal Amplifier

TA MHz oscilloscope probe TA MHz oscilloscope probe

Broadband Power Amplifier

Model 1791 VHF Radio User's Manual

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Model 3180B Mini-Bicon Antenna User Manual

Instruction Manual CT-6 High Frequency AC Current Probe

o-ring grease can be used to hold the o-ring in the groove during installation.

HDTV Antenna. Contemporary Indoor. User s Guide

Log Periodic Antenna

Model 3140B BiConiLog Antenna User Manual

TRANSDUCER IN-LINE AMPLIFIER

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

TRANSDUCER IN-LINE AMPLIFIER

Broadband Step-Up Transformer. User Manual

PDB4. Four Channel Passive Direct Box USER'S GUIDE

Model 935A Current Source Operation Manual

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

AT Advanced Wire Tracer. Users Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Radio Remote Controls Manual K Series

K1FO 12 ELEMENT 144/147 MHz YAGI

Single Flex and Double Flex Couplings (i)

M2M. Overview. volts DC. AC power.

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model 44L1/L1P BROADBAND RF WATT METER OPERATION MANUAL

Double-Ridged Waveguide Horn Model 3115 User Manual

o-ring grease can be used to hold the o-ring in the groove during installation.

Model 113 Scintillation Preamplifier Operating and Service Manual

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Model 3142B BiConiLog Antenna

High Performance Microphone Splitter. Artcessories. User's Manual

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

INSTRUCTION MANUAL. March 11, 2003, Revision 3

PARALLEL ELEMENT ANTENNA MODEL PEA-30

2100L Broadband Power Amplifier

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Model 44A/AP BROADBAND RF WATT METER OPERATION MANUAL

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Mirage B-320-G FEATURES

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Model Biconical Antenna. User Manual

MFJ-2389 Compact 8 Band Vertical

RF & MICROWAVE COMPONENTS. FIXED ATTENUATORS Watts Terminations & RF Test Accessories.

Type N Coaxial Calibration Kit

MICROTOOLS MICRONETBLINK KIT

User Guide. Digital AC/DC Clamp Meter Model 38394

742A Series Resistance Standards

User s Guide. Digital AC/DC Clamp Meter Model 38394

Transcription:

Current Probe Fixture Instruction Manual 1

TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 5 SAFETY 7 FIGURES 8 FORMULAS 10 MAINTENANCE 11 WARRANTY 12 2

INTRODUCTION figure 1 Mechanical Outline Model Number Frequency Range A B C D E Weight CPF-630 20 Hz 500 MHz 2.75 4.72 0.625 10.25 5.72 9.25 lbs. CPF-631 400 MHz 1.5 GHz 2.75 4.72 1.25 10.25 5.72 10.5 lbs. 3

GENERAL INFORMATION INTENDED PURPOSES This equipment is intended for general laboratory use in a wide variety of industrial and scientific applications, and designed to be used in the process of generating, controlling and measuring high levels of electromagnetic Radio Frequency (RF) energy. It is the responsibility of the user to assure that the device is operated in a location which will control the radiated energy such that it will not cause injury and will not violate regulatory levels of electromagnetic interference. GENERAL DESCRIPTION The current probe fixture is composed of an electrically short section of trough transmission line. The short section permits the measurement of current in the center conductor of the line, while the current probe is clamped around the center conductor. The fixture's output terminal is terminated in a 50 receiver, spectrum analyzer or RF voltmeter. A measurement of the voltage developed by this RF voltmeter permits the calculation of current flowing in the center conductor. The trough is large enough to permit the current probe to be clamped around the center conductor, with the outer conductor of the trough extending around the current probe's outer shield. A mechanical outline of the fixture and a typical injection probe mounted in the fixture is shown in Figure 1. This fixture is useable over the frequency range of 10 khz to 400 MHz. BROADBAND CURRENT PROBES (MONITOR PROBES) During the equipment test a broadband current probe (monitoring probe) is clamped around the same wire or wire bundle that the injection probe is clamped around. The broadband current probe shall be calibrated for the test frequencies and cable of operating with 1 ampere of RF current. The broadband current probe shall be located approximately 5 cm from the injection current probe. INJECTION CURRENT PROBES Injection current probes must be capable of injecting the specified current levels into the circuit under test. Each probe has its own technical description and model number, and each has its own individual technical literature. 4

TEST METHODS PROBES AND TEST FIXTURES In order to carry out a Bulk Current Injection Test, the following probes and fixture will be required: Calibration Test Fixture Broadband Current Probes (Monitor Probes) Injection Current Probes TEST METHOD FOR PRECALIBRATION Due to the occurrence of large variable circuit impedance s and resonances in cables, a calibration fixture is used to establish the forward power into the injection probe, which develops defined currents in the calibration fixture. The limits of current are established in a "Precalibration Test Set Up". This test configuration is shown in Figure 2. PRECALIBRATION TEST PROCEDURE This test procedure consists of precalibration to establish the levels of forward power necessary to generate the specification limits while clamped onto the calibration fixture. The precalibration is described in the following, and should be carried out first. 1) The injection probe will be clamped in the calibration fixture as shown in Figure 2. 2) The calibration fixture will be terminated in a 50 ohm, 50 watt RF load at one end and a 50 ohm receiver 30 db attenuator will be required to protect the receiver or spectrum analyzer. The VSWR of the terminations at both ends of the calibration fixture will be less than 1.2:1 over the frequency range of the test. 3) The injection probe receives signal levels from the signal generator and power amplifier. The limits of injected current in the calibrating fixture are precalibrated for two levels of current magnitude: 5

a) An accept/reject level of current which should not cause a malfunction in the equipment under test. b) A level of current which will cause a malfunction in the equipment under test, without creating permanent damage to it, or the specification level. 4) Precalibration Procedure Steps a) Increase the test signal to the injection probe until the accept/reject level of current is flowing in the calibration fixture. b) Record the forward power and reverse power necessary to generate the accept/reject level of current. c) Increase the test signal until the specification levels of current are achieved. d) Record the forward power and reverse power necessary to generate the specification levels of current. e) Repeat steps 1-4 over the required frequency range. The calibration frequency range can extend from 10 khz to 400 MHz. f) The forward power in steps 1-4 identifies the total power from the amplifier required to achieve the necessary current levels. The reverse power permits the ability to 1) establish the VSWR of injection probe, 2) the power forward - power reverse establishes the net power delivered to the load attached to the calibration fixture. g) The test report shall document steps 1-4 data. INJECTION OF CURRENT INTO EQUIPMENT CABLES PROCEDURE The equipment test shall be applied to individual wires and entire cables as required by the specifications. A test procedure will be prepared that identifies each wire and cable to be tested. In all cases of injected current, the test configuration used shall be as shown in Figure 3. The broadband current probe shall be placed at the specified distance from the injection probe. This distance is approximately 5 cm for most specifications. EQUIPMENT PROCEDURE TEST STEPS 1) Carry out the Precalibration Procedure Steps again in this test configuration and record the current from the broadband current probe. 6

2) At each test frequency, increase the signal level until a malfunction occurs or until the specification current level is measured by the broadband current probes. Record the following: Current from the Broadband Current Probe Forward power injected Reverse power injected 3) Repeat this test for all frequencies necessary. Measure enough frequencies to be sure that all susceptibility levels have been determined. 4) At frequencies where the equipment under test shows susceptibility, reduce the signal levels until the susceptibility stops. Record the same data as in step 2. SAFETY Caution during all of these tests is advised. High RF voltages and currents are being generated during these tests. Personnel conducting tests should not come in contact with any exposed metallic items of the test setup. Use extreme care when clamping current probes around uninsulated conductors. It is advised to de-energize the test item during assembly and disassembly of the test setup. Place all conductors passing through the aperture of probes in the center of the aperture for additional voltage breakdown protection. Do not permit the uninsulated current probe connector and cable connectors to come in contact with the ground plane or other adjacent conductors. 7

Figure 2 Precalibration of Injection Current Probe 8

Figure 3 Test Configuration for Current Injection 9

ANTENNA FORMULAS AND CALCULATIONS A specific Transfer Impedance Factor is associated with each frequency. This number is to be subtracted from the receiver reading in order to convert to dbua db A = db V (from Receiver) - Transfer Impedance (db ) + cable Loss (db) EXAMPLE: Assume that the frequency of interest is 80 KHz and we need to find the current at this frequency. Connect the probe per figure 1 Frequency: 80 KHz Transfer Impedance: -2.76 db ohms Cable Loss: 0.1dB Receiver Reading: -33.0dBuV db A = db V (from Receiver) - Transfer Impedance (db ) + cable Loss (db) db A = -33.0 - -2.76 + - 0.1 db A = -30.34 When injecting current: Injection current (db) = Input current (db) - Insertion loss (db) - Cable loss Maximum power rating : 100 Watts for 30 minutes Do not handle injection probe while testing is in progress. Hazardous voltages may be present. 10

MAINTENANCE To ensure reliable and repeatable long-term performance, annual re-calibration of your current probe by A.H. Systems experienced technicians is recommended. Our staff can recalibrate almost any type or brand of antenna. For more information about our calibration services or to place an order for antenna calibration visit our website at http://www.ahsystems.com or call 1(818) 998-0223. 11

WARRANTY INFORMATION A.H. Systems Inc., warrants that our Antennas, Sensors and Probes will be free from defects in materials and workmanship for a period of three (3) years. All other products delivered under contract will be warranted for a period of two (2) years. A.H. Systems' obligation under this warranty shall be limited to repairing or replacing, F.O.B. Chatsworth, California, each part of the product which is defective, provided that the buyer gives A.H. Systems notice of such defect within the warranty period commencing with the delivery of the product by A.H. Systems. The remedy set forth herein shall be the only remedy available to the buyer, and in no event shall A.H. Systems be liable for direct, indirect, incidental or consequential damages. This warranty shall not apply to any part of the product which, without fault of A.H. Systems has been subject to alteration, failure caused by a part not supplied by A.H. Systems, accident, fire or other casualty, negligence, misuse or normal wear of materials. Except for the warranty set forth above, there are no other warranties, expressed or implied, with respect to the condition of the product or it's suitability for the use intended for them by the buyer. For prompt service, please contact our service department for a Return Material Authorization Number before shipping equipment back to us. 12