Complete units: Selector switches ø 22mm

Similar documents
Control Stations ø 22

Complete units: Push-buttons ø 22mm

Complete units: Mushroom heads ø 22mm

Operator Heads: ø 22mm

Operator Heads: ø 22mm

Separate units: Blocks

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Pendant control stations 6

FM series position switches

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LR Position Switches TECHNICAL DATASHEET

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

Accessories. Accessories

Safety switches with slotted hole lever

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Pendant control stations 6

05/09/2012

Type CP-S, CP-C & CP-A Switch mode

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Pendant control stations 6

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Actuators Series 8602/3

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Characteristics 5 TeSys k contactors and reversing contactors

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

Three-phase monitoring relay CM-PFS

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Three-phase monitoring relays CM-PFE and CM-PFE.2

02/11/2015

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

NS..S contactor relays - with spring terminals AC operated

A W - A 2A R - 24D - 1

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Control module CP-A CM

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Solid-state Timer H3DS

62 Series - Power relays 16 A. Features / /

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Liquid level monitoring relay CM-ENS.2x

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Description Basic devices with positive operation contacts

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Switches & Pilot Devices

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-TGD.22

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

New Products Catalogue 2009 Safety Relays ESR5

2 or 4 pole changeover contact Plug-in/Faston 187

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Power consumption In operation At rest For wire sizing

General data. 13/20 Siemens IC Overview Front plate mounting

02/11/2015

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Electronic timer CT-MFS.21

Electronic timer CT-SDD.22

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Custom "Compact" range with display CD20 Custom Part number

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Position switches FM series

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Indicator actuator, white bezel, IP40 front protection, 16mm mounting - Indicator element, mounting flange and LED needed for complete unit

RT200 Series Single-axis Industrial Joystick. RunnTech

Controls Contactors and Contactor Assemblies Special Applications

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

02/11/2015

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Transcription:

Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions - 45 23 Black NO L21TA3-1E1 L22TA3-1E1 1 Black 2 NO L21TA3-3E2 L22TA3-3E2 Black NO + NC L21TA3-3E11 L22TA3-3E11 Maintained positions - 45 L21UA3-3E2 Black 1 2 2 NO L21UA3-3E2 L22UA3-3E2 WITH KEY 2 positions Ø 29.9 Supplied with 2 keys profile n 455 Maintained positions - 45 Key free in position Black NO L21LA-1E1 L22LA-1E1 1 Black 2 NO L21LA-3E2 L22LA-3E2 Black NO + NC L21LA-3E11 L22LA-3E11 2.1 26 26.2 48.4 L21LA-1E1 2.1 19.6 Spring Return - 45 Key free in position Black NO L21LB-1E1 L22LB-1E1 Black 1 2 NO L21LB-3E2 L22LB-3E2 Black NO + NC L21LB-3E11 L22LB-3E11 Maintained - 9 Key free in both positions Black NO L21LG-1E1 L22LG-1E1 1 Black 2 NO L21LG-3E2 L22LG-3E2 Black NO + NC L21LG-3E11 L22LG-3E11 WITH KEY 3 positions Ø 29.9 Supplied with 2 keys profile n 455 48.4 Maintained positions - 45 Key free in position 26.2 Black 2 NO L21NA-3E2 L22NA-3E2 1 2 2.1 26 Spring Return - 45 Key free in position L21NA-3E2 Black 2 NO L21ND-3E2 L22ND-3E2 1 2 17

GENERAL Characteristics Standards > Storage temperature - 4 C to + 7 C > Operating temperature - 25 C to + 7 C > Climatic resistance Constant humid heat IEC 668-2-3 Cyclic damp heat IEC 668-2-3 Resistance to sea air IEC 668-2-52 > Degree of protection IP 66 for standard heads IEC 6529 IP 67 for shrouded heads IP 66 for equipped control stations IP 2 at the rear of the panel for contact blocks and one piece pilot lights Type 1, 2, 3, 3R, 3S, 4, 4X, 12, and 13 for heads and control stations NEMA standard > Protection against mechanical impacts IK 5 illuminated and non-illuminated heads IEC 62262 IK 7 empty control station > Electrical insulation Class II - heads and control station IEC 6947-5-1 > Terminal marking IEC 6947-1 > Tightening torques Locking ring: recommended 3 N.m terminals: max. 1.2 N.m > Approvals UL United states and Canada UL 58, CSA 22.2 BV Bureau Véritas Marine rules Certification OC/CB IEC 6947-5-1 IEC 6947-5-5 IEC 6947-5-4 > Vibrations withstand vibration IEC 668-2-6 Fc test: 2 to 25 Hz, 1.6 mm; 25-1 Hz, 4 g 13

HEADS Characteristics Standards > Mechanical endurance Spring return: 5,, Push-push: 5, Selector switches: 3, Mushroom head maintained function EN 418: 1, Mushroom head maintained function: 15, > Activation force in N Spring return + NO: 6.5 Spring return + NC: 4.5 Additional NO contact: 4.5 Additional NC contact: 3. Push-pull mushroom head + NO + NC: 27 Push-turn mushroom head + NO + NC: 22 Push-pull mushroom head EN 418 + NO + NC: 37 Push-turn mushroom head EN 418 + NO + NC: 6 > Activation force in Nm Selector switch + NO:.4 Additional NO contact:.3 EMERGENCY STOP ACTUATORS - EN 418/ISO 1385: According to IEC/EN6947-5-5, the emergency stop function can be provided by an EN418/ISO1385 mushroom head combined with a "positive opening" NC contact block. The mechanism of our EN418/ISO1385 mushroom heads is so designed that a "push" action of sufficient force to open the contact systematically triggers an irreversible locking of this opening. This generates an "emergency stop" signal which can be cancelled only by deliberate manual resetting of the mushroom head (pull and turn or unlocking by key). This function allows to generate an "emergency stop" signal for any equipment subject to directive 98/37CE (machinery safety) completed by the IEC 624-1 standard. The EN418/ISO1385 mushroom heads also comply with the safety requirements detailed in standards EN418 and ISO1385. 14

CONTACT BLOCKS Screw and plug-in connection characteristics Standards > Rated insulation voltage 69 V AC IEC/EN 6947-1 6 V AC UL 58 > NC contacts Positive opening IEC/EN 6947-5-1 > Rated impulse voltage Uimp 6kV Pollution degree 3 > Conventional thermal current in free air conditions AC15: 1 A IEC 6947-5-1 DC13: 2.5 A > Electrical ratings Alternating current Direct current IEC 6947-5-1 AC15 - A 6 DC13 - Q 6 Ue = 12 V, Ie = 6 A Ue = 125 V, Ie =.55 A Ue = 24 V, Ie = 3 A Ue = 25 V, Ie =.27 A Ue = 38 V, Ie = 1.9 A Ue = 4 V, Ie =.15 A Ue = 48 V, Ie = 1.5 A Ue = 5 V, Ie =.13 A Ue = 5 V, Ie = 1.4 A Ue = 6 V, Ie =.1 A Ue = 6 V, Ie = 1.2 A Minimum operating current - standard blocks - gold plated contacts Ue = 24 V DC and Ie = 5 ma Ue = 5 V DC and Ie = 1 ma Failure rate < 1-8 Failure rate < 1-8 UL58 Alternating Current 5/6Hz - A6 Continuous Current - 1 amps Rated Voltage - 6Vac Direct Current - Q6 Continuous Current - 2.5 amps Rated Voltage - 6Vdc Max. Amps Max. Amps Max. Amps Max. Amps Voltage Make Break Voltage Make Break 72 6 1 24 2.5 2.5 12 6 6. 125.55.55 24 3 3. 25.27.27 48 15 1.5 31-6.1.1 6 12 1.2 > Electrical operating life 1 million cycles for: - AC15 - B 3 - DC13 - R 3 Ue = 12 V, Ie = 3 A Ue = 125 V, Ie =.22 A Ue = 24 V, Ie = 1.5 A Ue = 25 V, Ie =.1 A > Applicable wire sizes Rigid or flexible wire without ferrule:.5 mm 2 to 2 x 2.5 mm 2 Rigid or flexible wire with ferrule:.5 mm 2 to 2 x 1.5 mm 2 15

CONTACT BLOCKS Faston connection Standards > Rated insulation voltage 32 V AC IEC/EN6947-1 3 V AC UL 58 > NC contacts Positive opening IEC/EN 6947-5-1 > Rated impulse withstanding voltage Uimp 6 kv Pollution degree 3 > Conventional thermal current in free air conditions AC 15: 1 A IEC 6947-5-1 DC 13: 2.5 A > Electrical ratings Alternating current Direct current IEC 6947-5-1 AC15 - A 3 DC13 - Q 3 Ue = 12 V, Ie = 6 A Ue = 125 V, Ie =.55 A Ue = 24 V, Ie = 3 A Ue = 25 V, Ie =.27 A Minimum current of use Ue = 24 V DC and Ie = 5 ma Failure rate < 1-8 UL58 Alternating Current 5/6Hz - A3 Continuous Current - 1 amps Rated Voltage - 3Vac Direct Current - Q3 Continuous Current - 2.5 amps Rated Voltage - 3Vdc Max. Amps Max. Amps Max. Amps Max. Amps Voltage Make Break Voltage Make Break 72 6 1 24 2.5 2.5 12 6 6. 125.55.55 24 3 3. 25.27.27 > Electrical operating life 1 million cycles for: - AC15 - B 3 - DC13 - R 3 Ue = 12 V, Ie = 3 A Ue = 125 V, Ie =.22 A Ue = 24 V, Ie = 1.5 A Ue = 25 V, Ie =.1 A > Faston size 6.35 mm (.25 ) or 2 x 2.8 mm (.11 ) 16

CONTACT BLOCKS Pin-style connection (for PCB) Standards > Rated insulation voltage 25 V AC IEC/EN6947-1 25 V AC UL 58 > NC contacts Positive opening IEC/EN 6947-5-1 > Rated impulse withstanding voltage Uimp 4 kv Pollution degree 3 > Conventional thermal current in free air conditions AC 15: 5 A IEC 6947-5-1 DC 13: 1 A > Electrical ratings Alternating current Direct current IEC 6947-5-1 AC 15 - B 3 DC13 - R 3 Ue = 12 V, Ie = 3 A Ue = 125 V, Ie =.22 A IEC 6947-5-4 Ue = 24 V, Ie = 1.5 A Ue = 25 V, Ie =.1 A Minimum current of use - standard blocks - golden contacts Ue = 24 V DC and Ie = 5 ma Ue = 5 V DC and Ie = 1 ma Failure rate < 1-8 Failure rate < 1-8 UL58 Alternating Current 5/6Hz - B3 Continuous Current - 5 amps Rated Voltage - 3Vac Direct Current - R3 Continuous Current - 1 amp Rated Voltage - 3Vdc Max. Amps Max. Amps Max. Amps Max. Amps Voltage Make Break Voltage Make Break 72 3 5. 24 1. 1. 12 3 3. 125.22.22 24 15 1.5 25.11.11 > Electrical operating life 1 million cycles for: - AC15 - B 3 - DC13 - R 3 Ue = 12 V, Ie = 3 A Ue = 125 V, Ie =.22 A Ue = 24 V, Ie = 1.5 A Ue = 25 V, Ie =.1 A > Pin diameter ø 1 mm 17

LED BLOCKS FOR ILLUMINATED HEADS Characteristics Standards > Rated insulation voltage 3 V IEC/EN 6947-5-1 > Rated impulse voltage Uimp 4 kv (with filter block see p. 7) IEC/EN 6947-1 Pollution degree 3 > Operating voltage 12 to 24 V AC/DC 48 V AC/DC (for LED block) 13 V AC 23 V AC > Frequency 5 or 6 Hz > Lifetime at rated supply voltage Red and yellow: 1 hours at 25 C Other colors: 5 hours at 25 C > Consumption of LED blocks Voltage: - 24 V: 25 ma ± 2% - 48 V: 15 ma ± 5% - 13 V: 2 ma ± 1% - 23 V: 16 ma ± 3% ONE PIECE PILOT LIGHT BA9S Characteristics > Rated insulation voltage 4 V IEC 6947-5-1 > Rated impulse withstand voltage Uimp 4 kv IEC/EN 6947-1 > Bulb rating 4 V max. - 2.6 W max. IEC 6947-5-1 24 V max. - 2.6 W max. UL 58 18

PANEL CUT-OUT DRILLING Ø 22.3 +.4 - For heads equipped with electrical blocks with screw or plug-in terminals Minimum interval (mm) = 3 With or without legend (usual case) = 33 IP 67 (silicon shroud) B A A B = 4 With large legend plate > 4 For mushroom head ø 4 > 45 For selector switch with long handle = 38 For super-flush button = 5 With 5 position clip = 45 With or without legend plate (usual case) = 54 With double touch = 77 With double touch + legend plate = 5 Joystick DRILLING FOR SUPER-FLUSH BUTTON Ø 3.5 +.5 - DRILLING WHEN USING THE ANTI-ROTATION RING (OPTIONAL) 3.2 Ø 22.3 +.4-24.1 +.4 - THICKNESS OF PANEL (E) E = 1 to 6 mm E 19

NON-ILLUMINATED Note: Dimension are to FRONT of Panel. Head with 1 contact block in a 1 position clip Head with 1 or 2 contact blocks in a 3 position clip Head with 3 contact blocks in a 3 position clip 5 Head with 4 or 5 contact blocks in a 5 position clip Note: blocks cannot be stacked when using the 5 position clip Head with 4, 5 or 6 contact blocks 2 nd level of contact blocks stacked directly on first row (3 position clip) 64.5 11

ILLUMINATED Note: Dimension are to FRONT of Panel. Pilot light in a 1 position clip Illuminated head with LED and 1 or 2 contact blocks in a 3 position clip Illuminated head with LED and 3 or 4 contact blocks 2 nd level of contact blocks stacked directly in first row (3 position clip) 64.5 8.5 Illuminated head with LED on transformer supply with 1 or 2 contact blocks in a 3 position clip 5 Illuminated head with LED and 3 or 4 contact blocks in a 5 position clip Note: blocks cannot be stacked when using the 5 position clip Illuminated blocks 111

MECHANICAL OPERATION For 3 position selector switches Handle position (view from front of panel) 1 2 1 2 1 2 Non operated block Operated block Contacts block actuation (clip position) 2 3 1 2 3 1 2 3 1 MECHANICAL OPERATION For twin/triple touch switches Operator View (highlighted button is depressed) Non operated block Operated block Contacts block actuation (clip position) 2 3 1 2 3 1 2 3 1 MECHANICAL OPERATION For Joysticks 2 position 4 position Two block clip (LME3 - standard with joystick head) LM11 in Terminal Position Clip Location Numbers A O B Two block clip (LME3 - standard with joystick head) LM11 in Terminal Position Clip Location Numbers A B O C D 3-4 X O O 1 1-2 O O X 3-4 O O X 2 1-2 X O O 3-4 O O O O X 1 1-2 O O O X O 3-4 O X O O O 2 1-2 X O O O O Four block clip (LME5) LM11 in Terminal Position Clip Location Numbers A O B Four block clip (LME5) LM11 in Terminal Position Clip Location Numbers A B O C D 3-4 X O O 1 1-2 O O X 3-4 O O X 2 1-2 X O O 3-4 X O O 3 1-2 O O X 3-4 O O X 4 1-2 X O O 3-4 O O O O X 1 1-2 O O O X O 3-4 O X O O O 2 1-2 X O O O O 3-4 O O O O X 3 1-2 O O O X O 3-4 O X O O O 4 1-2 X O O O O 112

DIAGRAMS PUSH-TO-TEST LED PILOT LIGHT DIAGRAMS Lamp-testing module with 1 diode (33ET) for direct supply 24 V and 48V Lamp-testing module with 2 diodes (33ETT) for direct supply 24 V and 48 V Lamp-testing assembly for direct supply 13 V and 24 V L1 Test L1 Test L1 Test Lamp testing module Y X1 Lamp testing module X1 Y X Lamp testing module Test + LED assembly Load LED block Load LED block Load LED block with test L2 L2 L2 PRINTED CIRCUIT BOARD MOUNTING PCB Board Drill Plan Ø 1.2 +.1 -. 11.75 11.75 45 PCB Terminal - single clip PCB Terminal - 3 position clip 5 5 2.1 19.6 11.75 11.75 2.1 19.6 11.75 11.75 26 1 1 Ø 1 Ø 1 1 1 3 25 3 113