IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Similar documents
Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Controls Contactors and Contactor Assemblies Special Applications

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

page 2 of 86 Report reference No:

NS..S contactor relays - with spring terminals AC operated

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Output of three-phase motors at 50 Hz and 400 V

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

For non-electrical quantities

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Contactors and Contactor Assemblies

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C

Description Basic devices with positive operation contacts

Semiconductor contactors, Solid-state relays

Technical features table for miniature circuit-breakers SH 200 Series

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Modular equipment. Presentation, standards. Standard contactors TeSys GC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

38 Series - Relay interface modules A. Features /

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Capacitor Switching Contactors

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PVE

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Thermistor motor protection relays

Pluggable interface relays CR-P Pcb relays

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-SDS.22

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Relay interface modules A

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Modular Devices and Enclosures

Modular step relays 16 A

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SPST-NO SPDT DPST-NO DPDT

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.

Control module CP-A CM

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Three-phase monitoring relays CM-PFE and CM-PFE.2

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

E-STOP relays, safety gate monitors

INTERNATIONAL STANDARD

3TM Vacuum Contactors

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

TEST REPORT IEC Contactors and motor-starters Electromechanical contactors and motor-starters

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timers CT-S range Selection and ordering details

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

Semiconductor contactors, Solid-state relays

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

RN Thyristor Controllers

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Solid-State Switching Devices

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Classification Enclosure rating Contact form Contact material

Transcription:

APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- <6=>8? /@A7 B;CD /E FGH 34-52673892I2 <-3J892 K2E http://igs.nigc.ir/igs igs@nigc.ir

1- Scope This standard replaces IGS-EL-22(0):1999 and specifies minimum NIGC requirements of technical specification for electromagnetic A.C contactors whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1000 V A.C. 2- Normative References Throughout this standard specification, the following standards are referred to and are in effect at the time of issuing this standard specification. The applicability of changes in standards that occur after the date of standards that referred shall be mutually agreed upon by the purchaser and supplier and/or manufacturer. 1- IEC 60947-4-1: 2001,"Low-voltage switchgear and controlgear ": Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters. 2- IEC 60947-4-2: 2001,"Low-voltage switchgear and controlgear ": Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters 3- BS EN 60947-1:2007, "Low-voltage switchgear and controlgear ": Part 1: General rules. 4- IEC 61095 :2000, "Electromechanical contactors for household and similar purposes". 5- ISIRI 2868:1386," Degrees of protection provided by enclosures ( IP Code )". 6- BS EN 60947-5-1:2004, "Low-voltage switchgear and controlgear " : Part 5-1 : Control/circuit devices and switching elements-electromechanical control circuit devices. 7- BS EN 60445:2007," Basic and safety principles for man-machine interface, marking and identification -Identification of equipment terminals and conductor terminations". 8- BS EN 60715:2001." Dimensions of low-voltage switchgear and controlgear". Standardized mounting on Rails for Mechanical support of Electrical Devices in switchgear and controlgear.

3-Definitions 3.1 AC contactors AC contactors intended for closing and opening electric circuits. 3.2 Utilization Category The classification of contactors based on different loads as per clause 5.4,IEC 60947-4-1:2001. AC-1 Non Inductive or slightly inductive loads, resistance furnaces, heaters. AC-2 Slip-ring motors: starting,switching off. AC-3 Squirrel-cage motors: starting, switching off motors during running, most typical industrial application. AC-4 Squirrel-cage motors: starting, plugging, inching 3.3 Duty Class Maximum operation cycles of contactor per hour (Maximum operating rate). 3.4 Rated Insulation Voltage ( U i ) The rated insulation voltage of an equipment is the value of voltage to which dielectric tests and creepage distances are referred 3.5 Impulse Withstand Voltage ( U imp ) The highest peak value of an impulse voltage, of prescribed form and polarity, which does not cause breakdown under specified conditions of test. 3.6 Temperature Class of Insulating >

Designation of an Electrical Insulation System (EIS) that is equal to the numerical value of the maximum use temperature in degrees Celsius ( C) for which the EIS is appropriate. 3.7 Uninterrupted duty A duty without any off-load period in which the main contacts of an equipment remain closed, whilst carrying a steady current without interruption for periods of more than eight hours (weeks, months, or even years). 4-Requirements 4.1 Voltage Rating The rated operational contacts voltage of contactors shall be up to 400 V ac. 4.2 Current Rating (I e ) The rated operational contacts current of contactors shall be from 9 A ( Amperes ) to 210 A. 4.3 Overload current withstand capability of contactors Contactors with utilization categories AC-3 or AC-4 shall withstand the overload currents given in below table, as specified in EN 60947-4-1:2001 clause 9.3.5. Rated operational current Test current Duration of test D630 A 8 Ie max/ac-3 10 s 4.4 Power Rating The power rating of contactors shall be from 2 KW ( Kilo Watt ) to 110 KW. 4.5 Coil Voltage The coil voltage of contactors shall be from 24 to 440 V ac/dc.

4.6 Impulse Withstand Voltage ( U imp ) The rated impulse withstand voltage shall be 8 KV ( According to IEC 60947-2 ). 4.7 Insulation voltage ( U i ) The rated insulation voltage of contactor shall be 1000 V( According to IEC 60947-2) 4.8 Rated Frequency The supply frequency for which a contactor is designed and to which the other characteristic values correspond shall be 50 Hz. 4.9 Ambient Temperature The ambient temperature range shall be -20 to + 55 C. 4.10 Temperature Class of Insulating The temperature class of insulating shall be "F" ( 135 C ). 4.11 IP, Protection Class The ingress protection ( IP) class of contactors shall meet at least IP 20 according to IEC 60529:1989. 4.12 Number of Poles The contactors shall have 3 or 4 poles. When a contactor ( 4 poles ) is provided with a pole intended only for connecting the neutral, this pole shall be clearly identified to that effect by the letter "N".A switched neutral pole shall not break before and shall not make after the other poles. The value of the conventional thermal current shall be identical for all poles. 4.13 Auxiliary Contacts The auxiliary contacts of contactors shall have minimum 1 normally open ( NO ) and 1 normally close ( NC ) contact and dealt with in BS EN 60947-5-1:2004. H

4.14 Terminals Terminals shall be screw-type and all parts of terminals which maintain contact and carry current shall be of metal having adequate mechanical strength. Terminal connections shall be such that the conductors may be connected by screws so as to ensure that the necessary contact pressure is maintained. Terminals shall not allow the conductors to be displaced, or be displaced themselves in a manner detrimental to the operation of the contactor and the insulation voltage shall not be reduced below the rated values. The terminal shall be suitable for conductors of the same type (rigid. solid or stranded or flexible) at least two sizes smaller. Terminals shall be clearly and permanently identified in accordance with BS EN 60445:2007. 4.15 Mounting The contactor shall be fast, snap-on DIN rail mounted according to BS EN 60715:2001 and/or mounted by screws. 4.16 Rated duty The Rated duty of the contactor shall be uninterrupted according to EN 60947-1 :2007,clause 4.3.4.2. 4.17 Duty Class The duty class of the contactor shall be up to 120 cycles per hours. 4.18 Tests and Certificate All tests shall be done according to EN 60947-4-1:2001. Any certificate which declare the conformity of the product to EN 60947-4-1:2001 is acceptable. 5- Marking Each contactor shall be provided with a name-plate containing the following data marked in a durable manner and so placed that the marking is visible when the contactor is installed: a) Designation of the contactor, N

b) Manufacturer's name and/or trade-mark, c) Manufacturer's type reference and serial number, d) Country of origin. All the relevant technical details of the contactor shall be given in the separate leaflet, which shall include the following details: a) Overall dimensions and mounting details (Front/back connection), b) Number of main poles and their arrangement (NO/NC), c) Number of auxiliary contacts and their arrangement (NO/NC), d) Values of the operational currents for different utilization categories, classes of intermittent duty and on-load factors, e) Type and VA ratings, f) List of all components with parts numbered, g) Ratings of the auxiliary contacts, h) Mass of the contactor. 6- Documentation The approval test reports shall be issued by certifying body which is accepted by. O

Normative Annex Data sheet Item Subject Requirement Supplier offer Remark 1 Utilization Category AC1 AC2 AC3 AC4 2 Voltage Rating Up to 400 VAC 3 Current Rating 9 to 210 A 4 Power 2 to 110 KW 5 Overload current withstand capability 8 Ie max/ac-3,ac-4 Acc. to.en 60947-4-1:2001 6 Rated Frequency 50 Hz 7 Nos. of Poles 3/4 Poles 8 Coil Voltage 24 to 440 AC/DC 9 Aux Contacts 10 Mounting Min 1 NO, 1 NC Acc. to BS EN 60947-5-1:2004 On rail and/or by Screw Acc. to BS EN 60715:2001 11 Protection Class IP 20 12 Ambient Temperature - 20 to +55 C 13 Terminal Type 14 Temperature Class of Insulating 15 Rated duty Screwed type Acc. to BS EN 60445:2007 "F", 135 C Uninterrupted according to EN 60947-4-2:2001 15 Duty Class Up to 120 cycles per hour 16 Tests According to EN 60947-4-1:2001 Q

Any deviation from the above specification shall be clearly specified by Manufacturer / Supplier. This datasheet shall be signed by Manufacturer / Supplier.