VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Similar documents
CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

Submittals Quick Reference Guide

AMP SELECTOR Owner s Manual

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

SSI-4 PLUS User Manual

Welcome to Polaroid PhotoMAX FUN!

Vernier SpectroVis Plus Spectrophotometer (Order Code: SVIS-PL)

Operators Manual. Radio Transcorder. Recorder Radio Interface. SensorLink

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

Heart Rate/Pulse Sensor Product Number: ENHRT-A155

±50N FORCE SENSOR. Instruction Manual and Experiment Guide for the PASCO scientific Model CI A 6/ PASCO scientific $7.

Non-contact Forehead IR Thermometer

Smartphone RH/Temperature Probe Instruction Manual

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

23070 / Digital Camera Owner s Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

ET Water SmartWorks Panel Installation Guide

User s Guide. Digital AC/DC Clamp Meter Model 38394

The Heart Rate Exercise sensor can be connected to the all einstein Tablets, einstein LabMate, and einstein LabMate+.

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

Dawson DSM150. Digital Light Meter User s Manual

eflex 75x/300x Digital Microscope with Flexible Neck User Guide

Dawson DDM190. Digital Multimeter User s Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

DGT Smart Board manual English

Exercise 2-2. Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Ultrasonic level transmitter DISCUSSION

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

MicroLab 500-series Getting Started

SPM-50 RF Spectrum Power Meter PC Software User Manual

High Temperature InfraRed Thermometer with Laser Pointer

INSTRUCTION MANUAL. Model Model V/30A/150W DC Electronic Load

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Radio Systems CP-15 Coupler Manual

AC Digital Signal Generator Model DSG-8 User Manual

Heavy Duty Meter Model

X80 Activator. User's Manual. Version 1.1.

USB Microphone. Marshall Electronics

Introduction. Specifications. Features. Controls. Model 103

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

A W Table-Top Amplifier. with Built-in Bluetooth streaming

The Discussion of this exercise covers the following points: Differential-pressure transmitter. Differential-pressure transmitter

SERIES. Owners Manual & Installation Guide. Limited Warranty: 2-Channel High Speed Digital Stereo Amplifier

Remote Sensor Manual. User Guide. Revision A.0

Linear Motion Servo Plants: IP01 or IP02. Linear Experiment #0: Integration with WinCon. IP01 and IP02. Student Handout

INTRODUCTION TO DATA STUDIO

Experiment P-10 Ohm's Law

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Instruction Manual for the Software of ASSAN V2 Series Receiver

SensorTrace BASIC 3.0 user manual

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

ph / ORP Transmitter / Controller PH2000/ PH3000/ PH5000/ PH ph / ORP Operation Manual

PROCESS & TEMPERATURE CONTROLLERS

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Experiment P11: Newton's Second Law Constant Force (Force Sensor, Motion Sensor)

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Phono3. Two Channel Analog RIAA MM/MC Pre-Amplifier

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

TEMPO USB MICROPHONE

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson

uchat Model No. AC-406 Crystal clear audio on Skype, ichat & AIM Talk and walk without uncomfortable headsets

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

Model Digital Light Meter

Using the USB Output Port to Charge a Device

GIMP WEB 2.0 ICONS. Web 2.0 Icons: Paperclip Completed Project

VBRC 5. Radio Communicator. Installer Manual

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software

Help. Appendix A Camera Settings. IncuCount

Instruction also available on

DSP Amplifier. Installation Manual DSP3-700

DGT USB e-board manual English

Studuino Icon Programming Environment Guide

Keychain Radio Remote Control System

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Studuino Color Sensor Manual

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

User s Guide. Model MA A AC Mini Clamp-on Meter

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

LDG FT-Meter For Yaesu FT-857 and FT-897

GammaPAT MI 3311 Short instructions Ver. 1.4, Code no

Heart Rate Exercise Sensor Product Number: ENEXRT-A298

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

A-16D A-Net Distributor

DM-46 Instruction Manual

200Amp AC Clamp Meter + NCV Model MA250

Pen Multimeter. Model

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Connecting The EasySense unit will detect that the Current Sensor is connected.

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Ansoft Designer Tutorial ECE 584 October, 2004

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Transcription:

External Sensor VOLTAGE DT140 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-10V ±0.05V ±3% (before calibration) 3MΩ 2 calibration points ±30V ACCESSORIES User Guide for MicroLog EC600 and EC650

Microlog External Voltage Sensor DT140 The MicroLog External Voltage Sensor is one of MicroLog s 6 external sensors. This sensor allows MicroLog to sample any device or transmitter producing an analog and linear output between 0 and 10V. Using the MicroLab software, the analog voltage can be converted to any sensor unit simply by entering the sensor name, the unit and two calibration values. fig. 1 2

MICROLOG SOFTWARE Windows 3.x (MicroLab 2.0 only), Windows 95/98/2000/ME/XP compatible. Data can be exported to any common spreadsheet. The external voltage sensor is compatible with MicroLab software versions 2.0 or higher. Follow the steps below to select sensor using MicroLab 3.0 (or higher versions): Selecting the MicroLog External Sensor 1. Connect MicroLog to the PC using the serial communication cable. 2. Open the MicroLab software. 3. Select SETUP menu. 4. Activate the external MicroLog sensor by marking the external sensor check box (fig. 2). Selecting the External Voltage Sensor Select external voltage from the drop-down menu. If you are using the sensor to measure voltage, use the sensor s default parameters: Name = Voltage, Unit = V and Calibration Values = 0 and 10 Volts. 3

When connecting your own sensor to the 0-10V sensor, you can define it and view its results in your sensor s unit and values. In the DEFINE NEW SENSOR dialog box, select ADD, and select VOLTAGE. Then fill in the sensor name, unit and two sensor values representing the sensor s levels when it is measuring 0V and 10V. You may also define the sensor using other voltage values such as 2V and 9V. Once you have finished filling in all the parameters, select OK, the dialog box should close automatically. Choose the external sensor that you defined from the drop down menu. Then click on the SEND SETUP icon and MicroLog will automatically start running. fig. 2 4

Follow the steps below to select the sensor using MicroLab 2.0: Selecting the MicroLog External Sensor 1. Open the MicroLab software. 2. Connect MicroLog to the PC using the serial communication cable. 3. Click on STOP in the left-hand toolbar. 4. Activate the MicroLog external sensor by clicking on the Sensor Selection button next to the external sensor on the right-hand toolbar (fig. 3). 5. Program MicroLog by clicking on the yellow SEND arrow at the bottom of the right-hand toolbar. You will know MicroLog has been programmed when the yellow arrow becomes transparent. fig. 3 5

Selecting the External Voltage Sensor Select the small rectangle near the External sensor icon (fig. 3) In case you are using the sensor to measure voltage, use the sensor s default parameters: Name = Voltage, Unit = V and Calibration Values = 0 and 10 Volts. When using your own sensor while connected to the 0-10V sensor, you can define it and view its results in your sensor s unit and values. To do this, select the Voltage (0-10V) option in the Choose External Sensor dialog box. Fill in the sensor name, unit and the two sensor values representing the sensor levels when the sensor is measuring 0 and 10V. You may also define the sensor in other voltage values (e.g. 2, 9 volts). In fig. 4, you can see an example of the parameters selection for a pressure sensor producing a linear output 0 to 10V, while measuring 0 to 100 Bar. fig. 4 6

When all the parameters have been filled in, click OK. The dialog box should close automatically. If the box is not closed it means that MicroLog is either not connected to the PC or is in Sleep Mode. Before disconnecting the communication cable and connecting the sensor, please do not forget to set MicroLog to logging mode, by clicking on the Run button on the left-hand toolbar. WORKING WITH MICROLOG Disconnect the communication cable from MicroLog and insert the sensor connector cable in its place (fig. 5). Use the sensor terminals to connect to the voltage source you are measuring. The positive terminal is marked (+) and the negative terminal is marked (-). fig. 5 While measuring the 0-10V sensor, MicroLog s LCD will display Et. When downloading the data to the MicroLab software, the data will be displayed in the pre-defined units and values. There is no need to select the external sensor before downloading the data. 7

CALIBRATION Follow these instructions to calibrate your sensor using MicroLab 3.0 (or higher versions): 1. Select DEFINE NEW SENSOR to open the dialog box (fig. 6). 2. Press ADD to define new values. 3. Select external Voltage sensor for setting the sensor to a voltage 0-10 sensor. 4. Use a reference voltage source and measure two known voltage values such as 1V and 9V. 5. Write down the actual values MicroLog measured for these two known values. 6. Now define your own sensor using the actual voltage values you measured in Step 4. fig. 6 8

In the following example we have defined a pressure sensor producing an output of 0-10V, while measuring 0-100 Bar. We have calibrated this sensor between 1 to 9 volts. In this example, the sensor was measuring 1.1V when connected to a 1V reference, and 8.9V when connected to a 9V reference. Those values are used to define the pressure sensor as seen in fig. 6. The sensor can be calibrated to reach an accuracy of <±1%. Follow the instructions below to calibrate your sensor using MicroLab 2.0: 1. Use the Choose External Sensor dialog box and select the default setting of the sensor as a voltage 0-10V sensor. 2. Use a reference voltage source and measure two known voltage values with the sensor (e.g. 1, 9 volts). 3. Write down the values that MicroLog was reading for these two known values. 4. Now select the Choose External Sensor to define your own sensor using the actual voltage values you measured in Step 2. 9

fig. 7 In the following example we have defined a pressure sensor producing an output of 0-10V, while measuring 0-100 Bar. We have calibrated this sensor between 1 to 9 Volts. In this example, the sensor was measuring 1.1V when connected to a 1V reference, and 8.9V when connected to a 9V reference. Those values are used to define the pressure sensor as seen in fig. 7. 10

Warranty FOURIER SYSTEMS warranties this product to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse within the warranted time period, please return freight pre-paid and correction will be made without charge. FOURIER SYSTEMS alone will determine if the product problem is due to deviations or customer misuse. Out-of-warranty products will be repaired on a charge basis. Return of items Authorization must be obtained from your FOURIER SYSTEMS distributor before returning items for any reason. When applying for authorization, please include data regarding the reason the items are to be returned. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. We will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorized returns. Note: We reserve the right to make improvements in design, construction, and appearance of products without notice. 11

MORE AVAILABLE EXTERNAL SENSORS Temperature Sensor PH Sensor Current Sensor Contact Sensor Light Sensor -50 to 100 C (-58 to 212 F) 1-14 ph 0-20 ma open / close 0-5000 lux Contact Us For further information please contact our local dealer.