CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

Similar documents
VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Submittals Quick Reference Guide

AMP SELECTOR Owner s Manual

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

ET Water SmartWorks Panel Installation Guide

Vernier SpectroVis Plus Spectrophotometer (Order Code: SVIS-PL)

Heart Rate/Pulse Sensor Product Number: ENHRT-A155

SPM-50 RF Spectrum Power Meter PC Software User Manual

AC Digital Signal Generator Model DSG-8 User Manual

USB Microphone. Marshall Electronics

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Non-contact Forehead IR Thermometer

Smartphone RH/Temperature Probe Instruction Manual

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

23070 / Digital Camera Owner s Manual

Operators Manual. Radio Transcorder. Recorder Radio Interface. SensorLink

Dawson DSM150. Digital Light Meter User s Manual

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

eflex 75x/300x Digital Microscope with Flexible Neck User Guide

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

SSI-4 PLUS User Manual

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

Welcome to Polaroid PhotoMAX FUN!

DGT Smart Board manual English

Exercise 2-2. Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Ultrasonic level transmitter DISCUSSION

PROCESS & TEMPERATURE CONTROLLERS

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

MicroLab 500-series Getting Started

Dawson DDM190. Digital Multimeter User s Manual

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

High Temperature InfraRed Thermometer with Laser Pointer

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Radio Systems CP-15 Coupler Manual

±50N FORCE SENSOR. Instruction Manual and Experiment Guide for the PASCO scientific Model CI A 6/ PASCO scientific $7.

DSP Amplifier. Installation Manual DSP3-700

Heavy Duty Meter Model

Dual-band radio transmitter T10, Т10С T10U, T10UC

Introduction. Specifications. Features. Controls. Model 103

A W Table-Top Amplifier. with Built-in Bluetooth streaming

The Discussion of this exercise covers the following points: Differential-pressure transmitter. Differential-pressure transmitter

INTRODUCTION TO DATA STUDIO

Print then Cut Calibration

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

True RMS AC / DC Power Clamp Meter Model

SERIES. Owners Manual & Installation Guide. Limited Warranty: 2-Channel High Speed Digital Stereo Amplifier

Instruction Manual for the Software of ASSAN V2 Series Receiver

SensorTrace BASIC 3.0 user manual

Experiment P-10 Ohm's Law

CAST Application User Guide

MXL USB.006.

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

ph / ORP Transmitter / Controller PH2000/ PH3000/ PH5000/ PH ph / ORP Operation Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

TEMPO USB MICROPHONE

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson

User s Guide. Digital AC/DC Clamp Meter Model 38394

The Heart Rate Exercise sensor can be connected to the all einstein Tablets, einstein LabMate, and einstein LabMate+.

uchat Model No. AC-406 Crystal clear audio on Skype, ichat & AIM Talk and walk without uncomfortable headsets

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

NEULOG PHOTO GATE LOGGER SENSOR GUIDE

INSTRUCTION MANUAL. Model Model V/30A/150W DC Electronic Load

Model Digital Light Meter

Instruction Manual αlpha-do Wire Dissolved Oxygen Transmitter Dissolved Oxygen/ºC meter

GIMP WEB 2.0 ICONS. Web 2.0 Icons: Paperclip Completed Project

Using the USB Output Port to Charge a Device

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software

VBRC 5. Radio Communicator. Installer Manual

Help. Appendix A Camera Settings. IncuCount

Instruction also available on

DGT USB e-board manual English

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Studuino Icon Programming Environment Guide

OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Studuino Color Sensor Manual

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

Mid-Level UHF Dual Channel Wireless Microphone System

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Heart Rate Exercise Sensor Product Number: ENEXRT-A298

User s Guide. Model MA A AC Mini Clamp-on Meter

A-16D A-Net Distributor

GammaPAT MI 3311 Short instructions Ver. 1.4, Code no

PI-10 Broadband Power Indicator

X80 Activator. User's Manual. Version 1.1.

Portable Multi-Channel Recorder Model DAS240-BAT

Start Here. Unpack Contents. Install Software

Ansoft Designer Tutorial ECE 584 October, 2004

USB.007 Studio Quality USB Stereo Condenser Mic. User Manual

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Pen Multimeter. Model

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Linear Motion Servo Plants: IP01 or IP02. Linear Experiment #0: Integration with WinCon. IP01 and IP02. Student Handout

Transcription:

External Sensor CURRENT DT139 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-20mA ±0.1mA ±3% (before calibration) ~170Ω 2 calibration points ±55mA ACCESSORIES User Guide for MicroLog EC600 and EC650

Microlog External Current Sensor DT139 The MicroLog External Current Sensor is one of MicroLog s 6 external sensors. This sensor allows MicroLog to sample any device or transmitter producing an analog and linear output between 0 and 20mA. Using the MicroLab software, the analog current can be converted to any sensor unit simply by entering the sensor name, the unit and two calibration values. fig. 1 2

MICROLOG SOFTWARE Windows 3.x (MicroLab 2.0 only), Windows 95/98/2000/ME/XP compatible. Data can be exported to any common spreadsheet. The external current sensor is compatible with MicroLab software versions 2.0 or higher. Follow the steps below to select the sensor using MicroLab 3.0 (or higher versions): Selecting the MicroLog External Sensor 1. Connect MicroLog to the PC using the serial communication cable. 2. Open the MicroLab software. 3. Select SETUP menu. 4. Activate the MicroLog external sensor by marking the external sensor check box (fig. 2). Selecting the External Current Sensor Select the external current sensor from the drop-down menu. If you are using the sensor to measure current, use the sensor s default parameters: Name = Current, Unit = ma and Calibration Values = 0 and 20mA. 3

When connecting your own sensor to the 0-20mA sensor, you can define it and view its results in your sensor s unit and values. In the DEFINE NEW SENSOR dialog box, select ADD, and select CURRENT. Then fill in the sensor s name, unit and two values representing the sensor s levels when it is measuring 0mA and 20mA. You may also define the sensor using other current values such as 4mA and 20mA. Once you have finished filling in all the parameters, select OK, the dialog box should close automatically. Choose the External Sensor that you defined from the drop down menu. Then click on the SEND SETUP icon and MicroLog will automatically start running. fig. 2 4

Follow the steps below to select the sensor using MicroLab 2.0: Selecting the MicroLog External Sensor 1. Open the MicroLab software. 2. Connect MicroLog to the PC using the serial communication cable. 3. Click on STOP in the left-hand toolbar. 4. Activate the MicroLog external sensor by clicking on the Sensor Selection button next to the external sensor on the right-hand toolbar (fig. 3). 5. Program MicroLog by clicking on the yellow SEND arrow on the bottom of the right-hand toolbar. You will know MicroLog has been programmed when the yellow arrow becomes transparent. fig. 3 5

Choosing the External Current Sensor Select the small rectangle near the External sensor icon (fig. 3). In case you are using the sensor to measure current, use the sensor s default parameters: Name = Current, Unit = ma and Calibration Values = 0 and 20mA. When using your own sensor while connected to the 0-20mA sensor, you can define it and view its results in your sensor s unit and values. To do this, select the Current (0-20mA) option in the Choose External Sensor dialog box. Fill in the sensor name, unit and the two sensor values representing the sensor levels when measuring 0 and 20mA. You may also define the sensor in other current values (e.g. 4, 20mA). In fig. 4 you can see an example of the parameters selection for a pressure sensor producing a linear output 4 to 20mA, while measuring 0 to 100 Bar. fig. 4 6

When all the parameters have been filled in, click on OK. The dialog box should close automatically. If the box is not closed it means that MicroLog is either not connected to the PC or is in Sleep Mode. Before disconnecting the communication cable and connecting the sensor, please do not forget to set MicroLog to logging mode, by clicking on the Run button on the left-hand toolbar. WORKING WITH MICROLOG Disconnect the communication cable from MicroLog and insert the sensor connector cable in its place (fig. 5). Use the sensor terminals to connect to the current source you are measuring. The positive terminal is marked (+) and negative terminal is marked (-). fig. 5 While measuring the 0-20mA sensor, MicroLog s LCD will display Et. When downloading the data to the MicroLab software, the data will be displayed in the predefined units and values. There is no need to select the external sensor before downloading the data. 7

CALIBRATION The external current sensor can be calibrated to reach an accuracy of <±1%. Follow these instructions to calibrate your sensor using MicroLab 3.0 (or higher versions): 1. Select DEFINE NEW SENSOR to open the dialog box (fig. 6). 2. Select Add to define new values. 3. Select external Current sensor as the default for setting the sensor to a current 0-20mA sensor. 4. Use a reference current source and measure two known current values with the sensor, such as 4mA and 16mA. 5. Write down the actual values MicroLog measured for these two known values. 6. Now define your own sensor using the actual current values you measured in Step 4. In the following example we have defined a pressure sensor producing an output of 4-20mA, while measuring 0-100 Bar. We have calibrated this sensor between 4 to 16mA. In this example, the 0-20mA sensor was measuring 4.1mA when connected to a 4mA reference and 15.8mA when connected to a 16mA reference. Those values are used to define the pressure sensor as seen in fig. 6 8

fig. 6 Follow the instructions below to calibrate your sensor using MicroLab 2.0: 1. Use the Choose External Sensor dialog box and select the default setting of the sensor as a current 0-20mA sensor. 2. Use a reference current source and measure two known current values with the sensor (e.g. 4, 16mA). 3. Write down the values that MicroLog was reading for these two known values. 4. Now select the Choose External Sensor to define your own sensor using the actual values you ve measured in Step 2. 9

fig. 7 In the following example we have defined a pressure sensor producing an output of 4-20mA, while measuring 0-100 Bar. We have calibrated this sensor between 4 to 16mA. In this example, the 0-20mA sensor was measuring 4.1mA when connected to a 4mA reference and 15.8mA when connected to a 16mA reference. These values are used to define the pressure sensor as seen in fig. 7. 10

Warranty FOURIER SYSTEMS warranties this product to be free from significant deviations in material and workmanship for a period of one year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse within the warranted time period, please return freight pre-paid and correction will be made without charge. FOURIER SYSTEMS alone will determine if the product problem is due to deviations or customer misuse. Out-of-warranty products will be repaired on a charge basis. Return of items Authorization must be obtained from your FOURIER SYSTEMS distributor before returning items for any reason. When applying for authorization, please include data regarding the reason the items are to be returned. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. We will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorized returns. Note: We reserve the right to make improvements in design, construction, and appearance of products without notice. 11

MORE AVAILABLE EXTERNAL SENSORS Temperature Sensor PH Sensor Voltage Sensor Contact Sensor Light Sensor -50 to 100 C (-58 to 212 F) 1-14 ph 0-10 V open / close 0-5000 lux Contact Us For further information please contact our local dealer.