EMI Filter Safety. Herbert Blum Product Manager EMC

Similar documents
Caution - leakage currents! Leakage currents in fault-current protected environments

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

OUTLINE. Introduction. Introduction. Conducted Electromagnetic Interference in Smart Grids. Introduction. Introduction

C B. Models. Models 2MOPP

MTC Series 15 W AC/DC Switching Power Supply Module Medical

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Manual. MOVITRAC LTE-B/LTP-B Accessories Braking Resistors, Filters, Chokes, Shielding * _0515*

LFWLP W 12V 15.00A 25.00A 92%

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

Applications & Cases. EPCOS AG A TDK Group Company Edition

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

AC/DC Power Supply Single-Output

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Doc. EA Model Number:

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

AC-DC ITE & Medical Switching Power Supply

Industrial Applications Telecom Daracom

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

AC-DC ITE & Medical Switching Power Supply

Zelio Control Measurement Relays

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

Electrical Specifications

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

Power Supplies 3. SDN-C Compact DIN Rail Series

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

SAMSUNG ELECTRO-MECHANICS CO., LTD

Personalized Product Catalog

Watts HCP Series

EMC Test Report. Report Number: M030826

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Metal Case Power Supplies

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Electromagnetic Compatibility

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

For more information, please visit the product page. output. output current max (A)

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Cable Solutions for Servo and Variable Frequency Drives (VFD)

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

CB Patent Protection RoHS

Switching Power Supply Type SPP1 60W Enclosed type

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

LED control gear Linear / area fixed output

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

ISOMETER Headline IR /IR

Electrical Specifications

TB65 65W Single Output Test and Measurement/Industrial Series

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

General. Environmental. EMC & Safety

PDAM500 Series 500W Power Supply

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE

MB120S 120W Single Output Medical Series

Power supply CP-T 48/20.0 Primary switch mode power supply

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Sample Test Data SWF Series SWF100P W, High Surge Tolerant, Low Noise Power Supply

Power supply CP-E 24/20.0

FILTERS & SUPPRESSION

CB Scheme UL508 UL ATEX II3G

AC - DC 150W LED Driver MDC150 Single Output Series

Solid-state Timer H3DS

AC/DC Converter LD10-13Bxx Series

PF 0.96/230VAC PF 0.96/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load INPUT EFFICIENCY (Typ.)

Custom "Compact" range with display CD20 Custom Part number

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

Product Specification

CHAPTER 2 EQUIVALENT CIRCUIT MODELING OF CONDUCTED EMI BASED ON NOISE SOURCES AND IMPEDANCES

DC/DC Converter G_S-2WR2 & H_S-2WR2 Series

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

AC - DC 120~150W LED Driver MDC120 Single Output Series

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

SSD3000 MODULE 280 WATT 12V FRONT END 8.66 x 1.99 x x 50.5 x 40mm

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SAMSUNG ELECTRO-MECHANICS CO., LTD

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

TOSHIBA International Corp

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

80W Single Output Switching Power Supply

AC/DC Power Supply Series APPLICATION NOTE

150 Watt Industrial (WLT)

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

LED Driver Constant voltage

Transcription:

Herbert Blum Product Manager EMC

Level in dbµv EMI Filter Safety > Application with high EMI noise over the standard limits 80 70 60 EN 55011 Voltage on Mains QP Class B 50 EN 55011 Voltage on Mains AV Class B 40 30 20 10 0 150k 300k 400k500k 800k 1M 2M 3M 4M 5M 6M 8M 10M 20M 30M Fre quency in Hz 12.01.2017/BLU Product Marketing 2

Filter > Basic requirements > Voltage DC/AC / no. of phases > Current, inrush / leakage current > Attenuation: db @ khz, sym./asym. > Dimensions, weight, connection > Safety approvals Filter data sheet > Additional requirements > High voltage tests > Leakage currents > Inrush / overcurrents (e.g. SCCR) > Environment: temperature, humidity, vibration > Durability (MTBF) > Service: CAD and simulation data 12.01.2017/BLU Product Marketing 3

Filter high voltage tests > Standard requirements Standard Rated voltage L L L - PE IEC 60939-2 250 VAC 1075 VDC 1500 VAC / 2250 VDC UL 1283, CSA 22.2 no. 8 250 VAC 1000 VAC / 1414 VDC 1500 VAC / 2121 VDC IEC 60939-2 480 VAC 2064 VDC 2000 VAC / 3000 VDC UL 1283, CSA 22.2 no. 8 480 VAC 2000 VDC 2031 VAC / 2872 VDC > AC: 50/60Hz, 60 sec. > Test source min. 500 VA > Attention: repetition of the voltage proof test may damage the filter! 12.01.2017/BLU Product Marketing 4

Filter high voltage tests > Filter tests with AC voltage cause leakage current through capacitors > Example: 1µF 1500V 60Hz = 560mA (840 VA)! I = 2π f U C > Do HV tests on filters with DC 12.01.2017/BLU Product Marketing 5

Filter high voltage tests > Voltage ramp-up time > Too fast ramp-up time cause errors because of capacitor charging I = C V t (without internal and series resistance) wikipedia.org > Example: > 3 phase filter tested > 3000 VDC test L PE > ramp-up 5 sec. max. current 17mA 12.01.2017/BLU Product Marketing 6

High voltage tests on equipment with EMI filter > Do HV tests with DC > Be aware of the charge currents of the capacitors > Not too fast voltage ramp-up time > Don t do repetition of HV test too many times > Some application standards allow to disconnect the filter for HV tests > Example: IEC / UL 60950-1 (IT Equipment) > Test voltage AC 50/60Hz, or DC equal, 60 sec. > NOTE 2 Where there are capacitors across the insulation under test (for example, radio-frequency filter capacitors), it is recommended that d.c. test voltages are used. > NOTE 3 Components providing a d.c. path in parallel with the insulation to be tested, such as discharge resistors for filter capacitors and voltage limiting devices, should be disconnected. 12.01.2017/BLU Product Marketing 7

Leakage Currents > Leakage currents, are currents that under normal operation not returns through the neutral or line conductor > Direct coupling through capacitors e.g. Y-capacitors in mains filter wired from line to ground > to calculate I = 2π f U C > Capacitive coupling from line to ground e.g. cable shielded or long cables to chassis > Capacity often unknown > Higher frequencies generate high leakage currents > Long shielded cable = high capacity capacity between shield and wires 12.01.2017/BLU Product Marketing 8

Filter leakage currents > In EMC filters, capacitors from all conductors are wired to ground > Current is continually flowing through each of these Y-capacitors, and the amount depends on the size of the capacitor, grid voltage and the frequency Example leakage currents > Most filter manufacturers specify the maximum expected leakage current so that it is easier to select the most suitable filter 12.01.2017/BLU Product Marketing 9

> Leakage currents on filters data sheets Leakage current under normal condition acc. IEC60950-5.2.5 > Worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) 12.01.2017/BLU Product Marketing 10

Leakage current in frequency inverters > In inverter the associated harmonics of the switching frequency can have very large amplitudes at higher frequencies > These frequencies are on the motor cables and the motor > the motor cables with their grounded shields act like a capacitor to ground > Current is then diverted to earth through this capacitance > The same currents are flowing to ground inside the inverter and motor 12.01.2017/BLU Product Marketing 11

Leakage currents in frequency inverter system Leakage currents through capacitors Leakage currents parasitic capacity > Leakage currents in frequency inverters arise through internal interference-suppression measures and all parasitic capacitances in the inverter and motor cables 12.01.2017/BLU Product Marketing 12

Transient leakage currents > Transient leakage currents can arise when the system is turned on or off > Depending on the phase angle, turning the system on, can result in steeply rising voltage spikes as a result of the fast voltage increase > These fast voltage spikes generate a transient leakage current to ground through the filter capacitors 12.01.2017/BLU Product Marketing 13

System leakage currents > Mains frequency leakage currents of the EMI filter are known by the capacity to ground > Overall capacity of an inverter system are mostly not known > Leakage currents might occur over a wide frequency range > RCD shuts down operation when leakage currents are too high > RCD shuts down when system is first turned on or off (Residual-Current Device) > What to do? 12.01.2017/BLU Product Marketing 14

Leakage current measurement > It is recommended to measure the leakage current for every newly installed machine > The simplest method for doing so is to measure the current on the ground conductor with a clip-on ammeter > Most clip-on ammeters display only 50-Hz current! 12.01.2017/BLU Product Marketing 15

Leakage current measurement > Most clip-on ammeters display only 50-Hz current, and thus a better way to measure the value is with a leakage-current analysis system. 50Hz leakage current 12.01.2017/BLU Product Marketing 16

Measurement over frequency range 50Hz 6kHz 10kHz > Leakage current in higher frequency ranges (9 ma @ 6 khz) can be larger than at 50 Hz (6 ma @ 50 Hz)! 12.01.2017/BLU Product Marketing 17

Practical example > 2 different filters for a motor drive 12.01.2017/BLU Product Marketing 18

> 2 different filters for a motor drive FMAC ECO (single stage) FMBC ECO (double stage) 3 x 0.57 mh 3.3 F = max. 240mA 6 x 0.9 mh 47 nf = max. 4mA Quasi Peak Average 12.01.2017/BLU Product Marketing 19

Big Y-capacitors to ground cheap, compact, good attenuation but high leakage currents! Replacement of the Y-capacitors with an additional choke expensive, bigger, good attenuation and small leakage currents FMAC ECO (single stage) FMBC ECO (double stage) 12.01.2017/BLU Product Marketing 20

Reducing leakage currents > Placing the frequency inverter close to the motor shorter shielded cables = lower capacity = lower leakage current > Output filter (sinewave filter) on the drive output It effectively attenuates leakage currents above 1 khz by reducing the slew rate of the motor voltage > Central filter at the grid input instead of a filter for each inverter saves money and space but also reduces the leakage current > Power-line chokes reduces the current's ripple factor along with harmonics and thus provides for smaller leakage currents 12.01.2017/BLU Product Marketing 21

Reducing leakage currents > 4-conductor filter with a neutral instead of a 3-conductor filter Y-capacitors are connected between the phase conductors and the neutral conductor 3 conductor filter FMAC 4 conductor filter FMBD 8 Y-capacitors to PE 1 Y-capacitors to PE high leakage current small leakage current 12.01.2017/BLU Product Marketing 22

Reducing leakage currents > Separate circuits in RCD protected / non protected areas > Separate filtered and unfiltered cables > Starting up the system / frequency inverter in steps > Overvoltage protection to protect against voltage spikes > A RCD with delayed response characteristics > A differential RCM (residual current measuring device) > Low leakage-currents filters > Medical filters > 3 phase industrial filters with low leakage currents SCHURTER FMBC LL 3 phase low leakage current filter 12.01.2017/BLU Product Marketing 23

12.01.2017/BLU Product Marketing 24