RSP-3000 series. 3000W Power Supply with Single Output. File Name:RSP-3000-SPEC Sicherheit ID

Similar documents
TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 3000W MEAN WELL RSP-3000 Series

RSP-2400 series. 2400W Power Supply with Single Output. File Name:RSP-2400-SPEC Sicherheit ID

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 2400W MEAN WELL RSP-2400 Series

SPECIFICATIONS. Input Output Approvals

RSP-1500 series. 1500W Single Output Power Supply

RSP-1500 series. 1500W Single Output Power Supply. File Name:RSP-1500-SPEC Sicherheit ID

RSP-1500 series. 1500W Single Output Power Supply. File Name:RSP-1500-SPEC Sicherheit ID

RSP-1000 series. 1000W Power Supply with Single Output. File Name:RSP-1000-SPEC Sicherheit ID

RSP-1000 series. 1000W Power Supply with Single Output. File Name:RSP-1000-SPEC Sicherheit ID

RST series W Power Supply with Single Output. File Name:RST SPEC Sicherheit ID

RST-5000 series. 5000W Power Supply with Single Output. File Name:RST-5000-SPEC Sicherheit ID

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

RCP-1600 series. 1600W Rack Mountable Front End Rectifier. File Name:RCP-1600-SPEC Sicherheit ID

DRP-3200 series. 3200W Rack Mountable Front End Rectifier. File Name:DRP-3200-SPEC Sicherheit ID

SYNRAD PS DC Power Supply (Meanwell RSP )

RSP-2000 series. 2000W Power Supply with Single Output. File Name:RSP-2000-SPEC Sicherheit ID

RCP-1000 series. 1000W Front End Power System. File Name:RCP-1000-SPEC Sicherheit ID

RCP-2000 series. 2000W Rack Mountable Front End Rectifier. File Name:RCP-2000-SPEC Sicherheit ID

DBU-3200 series. 3200W Intelligent Single Output Battery Charger. File Name:DBU-3200-SPEC Sicherheit ID

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

RSP-1600 series. 1600W Power Supply with Single Output. File Name:RSP-1600-SPEC Sicherheit ID

RSP-2000 SERIES 2000 Watt Enclosed with Fan Power Supply Measures: x 5.00 x 1.61

RCP-1000 SERIES 1000 Watt Front End Power Supply Power Supply Measures: x 5.00 x 1.61

SPECIFICATIONS. Input Output Approvals

DPU-3200 series. 3200W Power Supply with Single Output. File Name:DPU-3200-SPEC Sicherheit ID

RSP-1600 series. 1600W Power Supply with Single Output. File Name:RSP-1600-SPEC Sicherheit ID

RSP-750_ EH RSP-750 series. 750W Power Supply with Single Output. File Name:RSP-750-SPEC

10000W Single Output Power Supply. Features. Applications. Description. Model Encoding RST

3000W Single Output Power Supply

24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%

DRC-40 series LPS. 40W Single Output with Battery Charger (UPS Function) File Name:DRC-40-SPEC Sicherheit ID

1000 ~ 3000W 1U Distributed Power System RCP-1U Rack System

TRC ELECTRONICS, INC

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID

LPS TRC ELECTRONICS, INC

E E E E E E E E E E E E E E

E E E E E E E E E E E E E E E

Features : 15V 50A 0 ~ 50A. 750W 150mVp-p. 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.

RCP-1600 series. 1600W Rack Mountable Front End Rectifier RCP-1600_ EH File Name:RCP-1600-SPEC

RKP-1U Rack System. 2000~6000W 1U Distributed Power System. File Name:RKP-1U RACK SYSTEM-SPEC Sicherheit ID

LPS. DRC-60 SERIES 60 Watt Battery Charger Power Supply Measures: 3.94 x 3.54 x 1.57 (866) MEAN WELL

R S P series

PSU s e r i es

RSP-2000 Series 2000W Single Output Enclosed Power Supplies

150W Single Output Switching Power Supply IP65 IP67

RHP-1U Rack System. 1600~8000W 1U Distributed Power/Charger System. File Name:RHP-1U RACK SYSTEM-SPEC Sicherheit ID

IP65 IP67 HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V 15V 20V 24V 30V 36V 42V 48V

HLG-150H SERIES 150 Watt LED Power Supply

RCP DC VOLTAGE 48V RATED CURRENT 42A CURRENT RANGE 0 ~ 100A 0 ~ 80A 0 ~ 42A RATED POWER. 2016W RIPPLE & NOISE (max.) Note.2 150mVp-p.

HLG-240H SERIES 240 Watt LED Power Supply

IP65 IP67 6.2A. Can be adjusted by internal potentiometer A type only

1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load. LEAKAGE CURRENT Earth leakage current < 300μA/264VAC, Touch leakage current < 100μA/264VAC

2000W Front End Power Supply

C: With I C Interface. Output Voltage I: AC Inlet(IEC320-C14) T: Terminal Block RCP DC VOLTAGE 48V RATED CURRENT 21A CURRENT RANGE

IP65 IP67. Can be adjusted by internal potentiometer A type and C type only. SETUP, RISE TIME Note ms,80ms/115VAC 500ms,80ms/230VAC at full load

2000W Front End Power Supply

IP65 IP67 ID

DRA-60 series LPS. 60W Single Output Switching Power Supply. File Name:DRA-60-SPEC Sicherheit ID

50W Single Output Switching Power Supply

MODEL HLG-80H-24 HLG-80H-48 HLG-80H-54

E E E E E E E E E E E E IP65 IP67

RCB-1600_ EH-0817 RCB W Rack Mountable Front End Battery Charger. Sicherheit ID File Name:RCB-1600-SPEC

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V 4.65 ~ 9.3A 1.0% 3.9 ~ 7.8A 1.0%

HLG-320H SERIES 320 Watt HARSH Power Supply

24V 14.4 ~ 24V 20V 12 ~ 20V. 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 40.

E E E E E E E E E E E E E IP65 IP67. 24V 30V 36V 42V 4.8A 4A 3.2A 2.65A 2.28A 96W 96W 96W 95.4W 95.76W 96W 150mVp-p 22 ~ 27V.

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

IP65 IP mVp-p. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable 5 ~ 10A 3 ~ 6A 1.0% 2.5 ~ 5A 1.

HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

E E E E E E E E E E E IP65 IP67 HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

IP64 HLN-40H-12 HLN-40H-15 HLN-40H-20 HLN-40H-24 HLN-40H-30 HLN-40H-36 HLN-40H-42 HLN-40H-48 HLN-40H-54 12V 20V 12 ~ 20V

IP64 36V 21.6 ~ 36V 4A 3A 2.5A 2A 1.7A 1.45A 1.3A 24V 14.4 ~ 24V 30V 18 ~ 30V. 60W 60W 60W 60W 61.2W 60.9W 62.4W 150mVp-p 17 ~ 22V.

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.

IP65 IP67. 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC

1U Rack Mountable Control and Monitor Unit

120W Single Output Switching Power Supply IP65 IP67

36V 21.6 ~ 36V 5A 5A 4A 3.4A 2.7A 2.3A 1.95A 1.7A 24V 14.4 ~ 24V 20V 12 ~ 20V. 60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 150mVp-p.

MODEL CLG CLG CLG CLG CLG CLG CLG V 18 ~ 24V 20V 15 ~ 20V

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

80W Single Output Switching Power Supply

24V 30V 90% 90% 90.5% 90.5% COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC

HLN-40H SERIES 40 Watt LED Power Supply Measures: 6.34 x 2.42 x 1.38

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

185W Single Output Switching Power Supply IP65 IP67

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

IP65 IP67 264W 285W 300W W 321W 320.4W 321.3W 321.6W

60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W

DRA-60 SERIES 60 Watt LED Power Supply Measures: 3.94 x 3.54 x 1.57 LPS (866) MEAN WELL

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load

24V 30V 60W 60W 60W 60W 61.2W 60.9W 62.4W 62.1W

Power Supply PSU05-045

HVG-65 SERIES 65 Watt LED Power Supply Measures: 7.44 x 4.42 x 1.45

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

E E E E E E E E E E E IP65 IP67

IP65 IP67. 54V CONSTANT CURRENT REGION Note.4 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V RATED CURRENT RATED POWER

800W Single Output Power Supply

300W Industrial 1U ATX 12V/P4 PC Power Supply CH3 12V STANDBY 5VSB RATED CURRENT CURRENT RANGE 30A 1 ~ 30A 18A 1 ~ 18A

Can be adjusted by internal potentiometer A type only ±1.0%

ELG-100 series. 100W Single Output Switching Power Supply IP67 IP65. File Name:ELG-100-SPEC

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

Transcription:

Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 3000W Power Supply with Single Output

SPECIFICATION MODEL RSP-3000-2 RSP-3000-24 RSP-3000-48 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER 2V 200A 0 ~ 200A 2400W 24V 25A 0 ~ 25A 3000W 48V 62.5A 0 ~ 62.5A 3000W RIPPLE & NOISE (max.) Note.2 50mVp-p 50mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 0.8 ~ 3.2V ±.0% 22 ~ 28V ±.0% 43 ~ 56V ±.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) 000ms, 80ms at full load 0ms at full load VOLTAGE RANGE FREQUENCY RANGE 80 ~ 264VAC 47 ~ 63Hz 254 ~ 370VDC POWER FACTOR (Typ.) 0.95/230VAC at full load INPUT EFFICIENCY (Typ.) 87.5% 90% 9.5% AC CURRENT (Typ.) 20A/80VAC 6A/230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT 60A/230VAC <2.0mA / 240VAC 00 ~ 2% rated output power OVERLOAD User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover PROTECTION 3.8 ~ 6.8V 28.8 ~ 33.6V 57.6 ~ 67.2V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down OUTPUT VOLTAGE 2.4 ~ 3.2V 4.8 ~ 28V 9.6 ~ 56V PROGRAMMABLE(PV) Please refer to the Function Manual. CURRENT SHARING Up to 9000W or (2+) units. Please refer to the Function Manual. FUNCTION AUXILIARY POWER(AUX) 2V@0.A(Only for Remote ON/OFF control) REMOTE ON-OFF CONTROL Please refer to the Function Manual REMOTE SENSE Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual. ALARM SIGNAL OUTPUT Power OK signal. Please refer to the Function Manual WORKING TEMP. -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing ENVIRONMENT -40 ~ +85, 0 ~ 95% RH non-condensing SAFETY & EMC (Note 4) OTHERS NOTE WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION ± 0.05%/ (0 ~ 50 ) 0 ~ 500Hz, 2G 0min./cycle, 60min. each along X, Y, Z axes UL60950-, TUV EN60950-, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:00M Ohms / 500VDC / 25 / 70% RH Parameter Standard Conducted Radiated Harmonic Current Voltage Flicker EN55024, EN6204-3, EN6000-6-2 Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions EN55032 (CISPR32) / EN550 (CISPR) Class B EN55032 (CISPR32) / EN550 (CISPR) Class A EN6000-3-2 ----- EN6000-3-3 ----- Standard EN6000-4-2 EN6000-4-3 EN6000-4-4 EN6000-4-5 EN6000-4-6 EN6000-4-8 EN6000-4- 223.8K hrs min. Telcordia SR-332 (Bellcore) ; 75.K hrs min. MIL-HDBK-27F (25 ) Test Level / Note Test Level / Note Level 3, 8KV air ; Level 2, 4KV contact Level 3 Level 3 Level 3, 2KV/Line-Earth ; Level 2, KV/Line-Line Level 3 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods 278*77.8*63.5mm (L*W*H) PACKING 4Kg; 4pcs/6Kg/.8CUFT

Block Diagram I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC PFC CONTROL O.T.P. POWER SWITCHING PWM CONTROL O.L.P. RECTIFIERS & FILTER O.V.P. DETECTION CIRCUIT PFC fosc : 88KHz PWM fosc : 00KHz +S -S PV POK AUX POWER LOAD SHARING FAN REMOTE CONTROL RECTIFIERS & FILTER RC CS AUX POWER (2V/0.A) Static Characteristics LOAD (%) 00 90 80 70 60 50 INPUT MODEL 80~264VAC 2V 24V 48V 2400W 3000W 3000W 200A 25A 62.5A 80 85 90 95 200 20 220 230 240 250 264 INPUT VOLTAGE (V) 60Hz Derating Curve Efficiency vs Load (48V Model) LOAD (%) 00 80 60 50 40 20-20 0 0 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE ( ) EFFICIENCY (%) 92 90 88 86 84 82 80 78 0% 20% 30% 40% 50% 60% 70% 80% 90% 00% LOAD The curve above is measured at 230VAC.

Function Manual. Remote Sense The Remote Sense compensates voltage drop on the load wiring up to 0.25V CN2 PIN7 -S PIN8 +S LOAD Sense lines should be twisted in pairs to minimize noise pick-up. Caution: The power supply, by factory default(also the assumption for other sections), is shipped with, -S & on CN2, as well as +S &, shorted by connector. When activating the Remote Sense, the +S signal should be connected to the positive terminal of the load whereas -S signal to 2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 20~0%(Typ.) of the nominal voltage by applying EXTERNAL VOLTAGE. CN2 PIN7 -S PIN8 +S PIN3 PV PIN5 -S EXTERNAL VOLTAGE (DC) Connecting an external DC source between PV & -S on CN2, and +S &, -S & also need to be connected. 20 Vout OVP >20% 00 00 OUTPUT VOLTAGE (%) 80 60 40 20 Non-Linear MODEL PV Range 2V 2.4 ~ 3.2V 24V 4.8 ~ 28V 48V 9.6 ~ 56V OUTPUT CURRENT (%) 80 60 40 20 2 3 4 5 6 EXTERNAL VOLTAGE (DC) V 20 40 60 80 00 20 OUTPUT VOLTAGE (%) V Please do not adopt PWM signal as the EXTERNAL VOLTAGE. The rated current should change with the Output Voltage Programming accordingly. Caution: ()By factory default, the Output Voltage Programming is not activated, and PV(PIN3) and PS(PIN4) of CN2 are shorted by connector. Whenever this function is not needed to activate, as assumed in other sections diagrams, please keep PV(PIN3) and PS(PIN4) of CN2 shorted ; otherwise, the power supply will have no output. (2) PV(PIN3) and PS(PIN4) of CN or CN2 must be disconnected if Output Voltage Programming function is used; otherwise, the internal electrical components may be damaged, and the power supply unit may thus be out of order.

3.Remote ON-OFF Remote ON-OFF is activated by the configuration with respect to CN,CN2 and CN3 as shown in the following diagram. CN2 PIN RCG PIN2 RC CN3 PIN7 AUXG PIN8 AUX By factory default, PV(PIN3) and PS(PIN4) on CN2 are shorted by connector; likewise, OLP(PIN9) and OL-SD(PIN0) on CN3 are shorted when shipped. Example 3.2(A): Using external voltage source AUX Internal 2V typ. KΩ RC RCG 2V SW AUXG Example 3.2(B): Using internal 2V auxiliary output AUX Internal 2V typ. KΩ RC RCG SW AUXG Example 3.2(C): Using internal 2V auxiliary output AUX Internal 2V typ. KΩ RC SW KΩ RCG AUXG Connection Method Example 3.2(A) Example 3.2(B) Example 3.2(C) SW Logic Power supply output ON SW Open SW Open SW Close Power supply output OFF SW Close SW Close SW Open

4.Alarm Signal Output Alarm signal is sent out through " P OK" & " P OK GND" and P OK2 & P OK GND2 pins on CN3. Please acknowledge an external voltage source is required for this function. CN3 PIN3 P OK GND2 PIN P OK GND PIN4 P OK2 PIN2 P OK By factory default, OLP(PIN9) and OL-SD(PIN0) on CN3 are shorted by connector when shipped. Function POK Description Output of alarm(p OK, Relay Contact) Output of alarm(p OK2, TTL Signal) The signal is "Low" when the power supply is above Low Low 80% of the rated output voltage, or, say, Power OK (0.5V max at 500mA) (0.5V max at 0mA) The signal turns to be "High" when the power supply is under 80% of the rated output voltage, or, say, Power Fail High or open (External applied voltage, 500mA max.) High or open (External applied voltage, 0mA max.) Table 3. Explanation of alarm POK POK2 R R V 0.uF V P OK GND External voltage and R (The max. sink is 500mA and 20V) P OK GND2 External voltage and R (The max. sink is 0mA and 30V) Fig. 4.2 Internal circuit of P OK (Relay, total is 0W) Fig. 4.3 Internal circuit of P OK2 (Open collector method)

5.Select Overload Protection Type ()Insert the shorting connector on CN3 that is shown in Fig 5.2, the Overload Protection Type will be "constant current limiting with delay shutdown after 5 seconds, re-power on to recover". This is the factory default. (2)Remove the shorting connector on CN3 that is shown in Fig 5., the Overload Protection Type will be "continuous constant current limiting". OL-SD OLP OL-SD OLP Fig. 5. Insert the CN3 Overload Protection Type : constant current limiting with delay shutdown after 5 seconds Fig. 5.2 Remove the CN3 Overload Protection Type : constant current limiting 6.Current Sharing with Remote Sense RSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below : The power supplies should be paralleled using short and large diameter wiring and then connected to the load. Difference of output voltages among parallel units should be less than 0.2V. The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(rated current per unit) (Number of unit) 0.9 When the total output current is less than 3% of the total rated current, or say (3% of Rated current per unit) (Number of unit) the current shared among units may not be fully balanced. No.(Master) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit Sense lines should be twisted in pairs to minimize noise pick-up. AC/L AC/N No.2(Slave) +S -S Load AC/L AC/N No.3(Slave) AC/L AC/N +S,-S and CS on CN or CN2are connected mutually in parallel. Under parallel operation, the "output voltage programming" function is not available.

6.Three Phase Connect Users can exploit three units of RSP-3000(unit,unit 2,unit 3) to work with 3ψpower system. Please refer to following diagrams for configuration. FIG. A: 3ψ3W 220VAC SYSTEM R 220V 220V S T unit L FG N unit 2 L2 FG2 N2 unit 3 L3 FG3 N3 FG FIG. B: 3ψ4W 220/380VAC SYSTEM 220V R N S unit L FG N unit 2 L2 FG2 N2 unit 3 L3 FG3 N3 380V T FG FIG. C: 3ψ4W 90/0VAC SYSTEM R 0V N S (N.C.) unit L FG N unit 2 L2 FG2 N2 unit 3 L3 FG3 N3 90V T FG

+ 3000W Power Supply with Single Output Mechanical Specification 278 236.3 27 40 Case No.982B Unit:mm 8-M4(Both Sides) L=5mm 38 2.5 2-M4 M3 ψ8.5 20 63.5 CN CN2 CN3 8 6 4 2 8 6 4 2 0 8 6 4 2 7 5 3 7 5 3 9 7 5 3 236.3 27 4-M4 L=5mm 7.9 OUTPUT 4 LED SVR CN CN2 CN3 8 6 4 2 8 6 4 2 0 8 6 4 2 7 5 3 7 5 3 9 7 5 3 Air flow direction 62 77.8 INPUT 0 3 2 3 6max. TB Mounting Instruction Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque M4 5mm 7~0Kgf-cm Mounting Surface Chassis of RSP-3000 Control Pin No. Assignment (CN,CN2) : HRS DF-8DP-2DS or equivalent 8 2 7 Mating Housing Terminal HRS DF-8DS or equivalent HRS DF-**SC or equivalent Mounting Screw L CN and CN2 are connected internally. Pin No. 2 3 4 5,7 6 8 Function RCG RC PV PS -S CS(Current Share) +S Description Remote ON-OFF Ground Remote ON-OFF Connection for output voltage programming Reference Voltage Terminal Negative sensing for remote sense Current Share Postive sensing for remote sense

Control Pin No. Assignment (CN3) : HRS DF-0DP-2DS or equivalent 0 2 Mating Housing HRS DF-0DS or equivalent 9 Terminal HRS DF-**SC or equivalent Pin No. Function Description P OK GND Power OK Ground 2 POK Power OK Signal (Relay Contact) 3 P OK GND2 Power OK Ground 4 POK2 Power OK Signal (TTL Signal) 5 RCG Remote ON-OFF Ground 6 RC Remote ON-OFF 7 AUXG Auxiliary Ground 8 AUX Auxiliary Output 9 OLP Overload(OLP) type select 0 OL-SD AC Input Terminal Pin No. Assignment Pin No. 2 3 Assignment Diagram Mx a imum mounting torque AC/L AC/N FG 8Kgf-cm Installation Manual Please refer to : http://www.meanwell.com/manual.html