Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Similar documents
Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifier for flow control with proportional

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Electric amplifier for proportional cartridge throttle valves

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

RA / /6. Replaces: Table of contents RA /06.98

4/3 proportional directional valve direct operated, with integrated electronics

p/q closed-loop control amplifier

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

RT-5005/5006/5007/5008

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

Analog amplifier RA. RE Edition: Replaces:

Service case with test unit for servo and proportional valves with integral electronics (OBE)

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

DENISON HYDRAULICS Proportional Pressure Control Valves

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

Digital axis control HNC100

4/3-way fast response valve Type 4WRGE

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Accessories Power Amplifiers

Drive electronics pq11

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Proportional directional valves

Drive Electronics pq11

Mobile dual solenoid driver

Digital amplifier for proportional valves PEM XD

Analog position controller

MDSD (Series 2X) Mobile Dual Solenoid Driver

ELECTRONIC REGULATOR FOR OPEN LOOP

Sensor technologies Proximity sensors Series ST9. Brochure

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Proportional Directional Control Valves Size 6

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

Digital axis control. Table of contents. RE 30139/08.12 Replaces: Type VT-HNC100. Component series 3X 1/20

Frequency converter. Frequency Converter Fe

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Directional valves Coils Series CO1. Brochure

Proportional amplifier type EV22K5

Proportional Directional Control Valves Nominal sizes 16 and 25

Speed sensor DSA series 12

Electronic amplifier type EV1D

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

EURAX UI 505, Combined Transducer for AC current and AC voltage

Digital Function Generator

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Proportional Directional Control Valves Size 6

Analog Servo Drive 25A20DD

Proportional amplifier type EV1M3

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

Proportional amplifier type EV1M3

Operating Instructions

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

ph or ORP Transmitter

Analog Servo Drive 20A20

Analog Servo Drive 30A8

LENORD. +BAUER... automates motion. GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter

Continental Hydraulics Installation Manual CEM-RA-A

Analog Servo Drive 30A8

400 (±2,5 V/ V/ ,3% V4A

S200 I/O System Units

OPERATION MANUAL LDM-1000

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Analog Servo Drive 30A20AC

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Continental Hydraulics Installation Manual CEM-PA-A

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

AxCent Servo Drive A25A100

BFS / BFSM SERIES Installation & Maintenance Manual

Transcription:

Valve amplifier for proportional directional valves Type VT-VRPA RE 0119 Edition: 01-0 Replaces: 07.05 Component series 1X Analog, Euro-card format Suitable for controlling / proportional directional valves with electrical position feedback: WRE 6 -X, WRE 10 -X H661 Features Contents Differential input (±10 V) Four callable command value inputs (±10 V) Current input ( 0 ma) Inversion of the internal command value signal via V input or jumper Selection of ramp time via quadrant recognition ( V input) or ramp time call-ups ( V inputs) with option T5 Selection of the ramp time range via jumper Characteristic curve correction by means of separately adjustable step levels and maximum values Enable input "Ready for operation" output signal Switchable measuring socket with option T5 Reverse polarity protection for the voltage supply Power supply with DC/DC converter without raised zero point Features 1 Ordering code Function Block diagram/pin assignment, option T1 Block diagram/pin assignment, option T5 5 Technical data 6 Display/adjustment elements, option T1 7 Display/adjustment elements, option T5 8 Dimensions 10 Project planning / maintenance instructions / additional information 10 Bosch Rexroth AG, RE 0119, edition: 01-0

/10 VT-VRPA Valve amplifier Ordering code 01 0 0 0 05 06 VT-VRPA 1X / V0 / / * 01 Valve amplifier for proportional directional valves and proportional pressure valves, analog, euro-card format VT-VRPA 0 For controlling / proportional directional valves WRE 6 -X 1 For controlling / proportional directional valves WRE 10 -X 0 Component series 10 to 19 (10 to 19: Unchanged technical data and pin assignment) 1X 0 Version: Standard V0 05 Option: With one ramp time T1 Option: With five ramp times T5 06 Further details in the plain text * Accessories Open card holder VT 00-1-X/8F (see data sheet 998) Function Power supply unit [1] The amplifier card has a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. Command value specification The internal command value signal is calculated from the total (summation [6]) of the external command value signal available at the differential input [] and at the current input [], the called-up signal [] and the zero point offset [5] (zero point potentiometer "Zw"). The following applies: Standard values Current input Differential input Command value measuring socket Flow direction 100 % ma 10 V 10 V P to B, A to T 0 % 1 ma 0 V 0 V 100 % 0 ma 10 V 10 V P to A, B to T 0 % < 1 ma 1) 0 V 1) If the current input is not wired-up or if the cable of the current command value is broken, the resulting internal command value signal is 0 %. There is no switch-over between current and voltage input. The inputs are permanently available (see block diagram). Command value call-ups [] Four command value signals "w1" to "w" can be called up. The external command value voltages (command values 1 to ) are either defined directly by the regulated voltage outputs +10 V and 10 V or via external potentiometers. If these command value inputs are directly connected to the regulated voltages, the command values are set at the potentiometers "w1" to "w". When using external potentiometers, the internal potentiometers will function as attenuators or limiters. Only one call-up can be operated at the same time. If several call-ups are operated simultaneously, call-up "1" has the lowest priority and call-up "" has the highest priority. The respective active call-up is indicated via a yellow LED on the front plate. Command value inversion [7] The command value created internally from the input signals, the command value call-ups and the zero point offset signal can be inverted by an external signal or jumper J1. The inversion is indicated by an LED (" 1") on the front plate. Bosch Rexroth AG, RE 0119, edition: 01-0

Valve amplifier VT-VRPA /10 Enable function [8] The enable function enables the power output stages and forwards the internal command value signal to the ramp generator. The enable signal is indicated by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value specification) by the set ramp time. Thus, a controlled valve does not open abruptly. Ramp generator [9] The ramp generator limits the rise of the control output. The downstream step functions and amplitude attenuators do not extend or shorten the ramp time. Using jumper J, the ramp time is set to a minimum (< ms) (ramp off). External ramp time setting: Using an external potentiometer, the internally set ramp time can be extended. The setting can be verified by means of the measuring socket. In case of a cable break, the internal default setting will be valid automatically. Position controller [17] The position controller is optimized in a valve-specific manner. Power output stage [18] The power output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to.5 A to.8 A per output. The output stage outputs are short-circuit-proof. The output stages are deenergized in case of an internal fault signal or if they have not been enabled.. Fault recognition [19] The position transducer cable is monitored for cable break and short-circuits on the primary side as well as for over-currents at the output stage. [ ] = Attribution to the block diagrams on pages and 5 Note for setting and measuring the ramp time: Value at measuring socket "t" (T1) / "v" (T5) U t / V 5 Current ramp time (±0 %) t / ms 0 50 U t / V 1 0.5 0. 0. 0.1 0.05 0.0 0.0 t / ms 100 00 500 1000 000 5000 By closing the jumper J, the ramp times specified above can be increased tenfold. Characteristic curve generator [11] Using the adjustable characteristic curve generator, the step level and maximum values for positive and negative signals can be set separately according to the hydraulic requirements. The actual development of the characteristic curve through the zero point is not stepped but linear. Amplitude limiter [1] The internal command value is limited to approx. ±110 % of the nominal range. Oscillator [1] The oscillator creates the control signal for the inductive position transducer. Demodulator [15] The demodulator supplies the actual value signal of the valve spool position from the position transducer signal. 100 % 10 V RE 0119, edition: 01-0, Bosch Rexroth AG

b1 b0 d10 d1 d1 d16 +15 V + + 1 d d8 b1 b16 b b b8 b6 b b d d d6 d8 w u u w u u i u w b10 d18 8 V 0 V z0 z b18 z z6 z8 L0 t 6 Zw 5 w1 7 J1-1 UL 100 F DC 1 DC max t + F J, J t t t 9 t t ok 1 Gw+ Gw- 11 S- Gx S+ J 1 +15 V +7,5 V +5 V M0 5 V 7,5 V 15 V w d6 1 d0 z 17 Controller U 18 z6 z8 z z ok 1 +1 z18-1 z1 15 + - z1 z16 z10 Zx 16 x d d0 ok & d UL 19 b b0 1 F t b6 b8 z0 I /10 VT-VRPA Valve amplifier Block diagram/pin assignment, option T1 Internal command value Solenoid b Inductive position transducer Solenoid a External ramp time Command value 5 ±10 V Actual value Command value 6 0 ma Command value Command value Command value Command value 1 Command value call-ups 1 to Inversion Enable Operating voltage 1 Power supply unit Differential input Current input Command value selection logic 5 Zero point setting Enable Ready for operation +10 V / 5 ma 10 V / 5 ma Measurement signal Ramp time M0 6 Command value summation 7 Command value inversion 8 Enable function 9 Ramp generator 11 Characteristic curve generator UP/DOWN Eable System earth Error detection 1 Amplitude limiter 1 Command value output 1 Oscillator 15 Demodulator 16 Actual value output 17 Position controller 18 Power output stage 19 Fault recognition Bosch Rexroth AG, RE 0119, edition: 01-0

1 b1 b0 d10 d1 d1 d16 +15 V + + 1 d d8 b1 b16 b b b8 b6 b b d d d6 d8 w u u w u u i u w b10 d18 8 V 0 V z0 z b18 z z6 z8 L0 t1 10 A B C D t t t t5 6 6 5 Zw 5 1 w1 7 J1 UL 100 F DC 1 DC -1 E 1 w d6 1 d0 ok Gw+ F S+ J Q max t t1 t 9 Gw- J, J S- + - t t t 7 11 1 0 Gx 1 15 8 ok +1-1 U z z6 z8 z z z18 z1 + - z1 z16 x z10 d +15 V +7,5 V +5 V M0 5 V 7,5 V 15 V 1 17 Controller Zx 16 18 + & 01 5 67 89 A BC DEF 0 19 ok UL v d0 d b b0 b6 b8 z0 I Valve amplifier VT-VRPA 5/10 Block diagram/pin assignment, option T5 Internal command value Solenoid b Inductive position transducer Solenoid a Actual value 0156789ABCDEF External ramp time Command value 5 ±10 V Command value 6 0 ma Command value Command value Command value Command value 1 Command value call-ups 1 to Inversion Enable Operating voltage Ready for operation +10 V / 5 ma 10 V / 5 ma Measurement signal M0 -quadrant operation Ramp call-ups 1 to 1 Power supply unit Differential input Current input Command value selection logic 5 Zero point setting 6 Command value summation Enable 7 Command value inversion 8 Enable function 9 Ramp generator 10 Ramp time selection logic 11 Characteristic curve generator 1 Amplitude limiter Enable Error detection Measuring points 1 Command value output 1 Oscillator 15 Demodulator 16 Actual value output 17 Position controller 18 Power output stage 19 Fault recognition 0 Measuring point switch-over System earth RE 0119, edition: 01-0, Bosch Rexroth AG

6/10 VT-VRPA Valve amplifier Technical data (for applications outside these parameters, please consult us!) Operating voltage U B VDC + 0 % 0 % Operating range: Upper limit value U B (t) max 5 V Lower limit value U B (t) min 18 V Power consumption P S < VA Current consumption I < A Fuse I S A medium time-lag, exchangeable Inputs, analog Command values 1 to (potentiometer inputs) U e 0 ±10 V, R e > 100 kω (M0 is reference) Command value 5 (differential input) U e 0 ±10 V, R e > 50 kω Command value 6 (current input) I e 0 ma, load R B = 100 Ω External ramp time U e 0 +10 V, R e = 10 kω (internally increased to +15 V, M0 is reference) Inputs, digital Command value call-ups, Command value inversion, Enable, Ramp call-ups (option T5), -quadrant operation (option T5) U U 8.5 V U B > ON, R e > 100 kω 0 6.5 V > OFF, R e > 100 kω Setting ranges Zero adjustment (potentiometer "Zw") ±0 % Command values (potentiometers "w1" to "w") 0 110 % Ramp times (potentiometer "t1" to "t5") 0 ms 5 s, switchable to 0. 50 s Step level (potentiometer "S+" and "S ") 0 50 % Amplitude attenuator (potentiometer "G+" and "G ") 0... 110 % (applies to the step level setting of 0 %) Outputs Command value signal U ±10 V ± %, I max = ma Actual value signal U ±,5 V ± %, I max = ma Measurement signal (option 5) U ±10 V ± %, I max = ma Ready for operation U > 16 V, 50 ma (in case of a fault: U < 1 V, R i = 10 kω) Regulated voltages U ±10 V ± %, 5 ma, short-circuit-proof Power output stage I 0.5 A, short-circuit-proof, clocked with approx. 5 khz Oscillator U ±5 V SS per output, 10 ma f 5.6 khz ± 10 % Measuring sockets Command value "w" ±10 V ± %, I max = ma Actual value signal "x" ±10 V ± %, I max = ma Ramp time "t" See description on page Socket "v" (option T5) See description on page and table on page 9 Type of connection 8-pin male multipoint connector, DIN 161, design F Card dimensions Euro card 100 x 160 mm, DIN 19 Admissible operating temperature range ϑ 0 50 C Storage temperature range ϑ 5 C +85 C Weight m 0.17 kg (net) Notice: For information on the environment simulation testing for the areas EMC (electromagnetic compatibility), climate and mechanical load, see data sheet 0119-U. Bosch Rexroth AG, RE 0119, edition: 01-0

Valve amplifier VT-VRPA 7/10 Display/adjustment elements, option T1 REXROTH -1 Gw + S+ Gw - S- J J6 No function! Reserve Zw w1 w w w J J J1 Zx J5 t Gx x w t J7 VRPA No function! for special functions Inversion J1 Ramp function J Ramp time J Step function J Inverting Off 0. 50 sec. Off Not inverting On 0.0 5 sec. On LED displays: Ready for operation (green) Enable (yellow) 1 External inverting = Factory setting of the jumpers = Jumper closed = Jumper open Measuring sockets: x, w, t Measurement signal (see page 6) Measurement zero Potentiometers (some with LED display): Zw Zero point calibration Adjustable on the board: w1 Command value 1 Gw+ Amplitude attenuator for positive command values w Command value Gw Amplitude attenuator for negative command values w Command value S+ Step level for positive direction w Command value S Step level for negative direction t Ramp time The warranty expires if the sealed potentiometer is adjusted. RE 0119, edition: 01-0, Bosch Rexroth AG

80 1 5 6 7 8/10 VT-VRPA Valve amplifier Display/adjustment elements, option T5 REXROTH -1 Q T Gw + S+ Gw - S- J J6 No function! Reserve Zw w1 w w w t1 t t t t5 J J Zx Gx J5 J1 x 9 A BCD EF v0 - vf w v Measuring point selector switch J7 VRPA No function! for special functions Inversion J1 Ramp function J Ramp time J Step function J Inverting Off 0. 50 sec. Off Not inverting On 0.0 5 sec. On LED displays: Ready for operation (green) Enable (yellow) 1 External inverting Q -quadrant operation T = Factory setting of the jumpers = Jumper closed = Jumper open Measuring sockets: x, w, v Measurement signal (see page 6) Measurement zero Potentiometers (some with LED display): Zw Zero point calibration Adjustable on the board: w1 Command value 1 Gw+ Amplitude attenuator for positive command values w Command value Gw Amplitude attenuator for negative command values w Command value S+ Step level for positive direction w Command value S Step level for negative direction t Ramp time The warranty expires if the sealed potentiometer is adjusted. Bosch Rexroth AG, RE 0119, edition: 01-0

Valve amplifier VT-VRPA 9/10 Display/adjustment elements, option T5 (continued) Measuring socket "v" Signal designation Measuring point selector switch Measurement signal "v" Internal command value 0 ±100 % ±10 V Command value call-up 1 1 ±100 % ±10 V Command value call-up ±100 % ±10 V Command value call-up ±100 % ±10 V Command value call-up ±100 % ±10 V Zero point offset "Zw" 5 ±0 % ± V Composite signal of the command values 6 ±100 % ±10 V Ramp output signal 7 ±100 % ±10 V Zero point offset "Zx" 8 ±0 % ±10 V Not connected 9 Ramp time "t1" A 10 mv 10 V 1) Ramp time "t" B 10 mv 10 V 1) Ramp time "t" C 10 mv 10 V 1) Ramp time "t" D 10 mv 10 V 1) Ramp time "t5" E 10 mv 10 V 1) Current ramp time "t" F 10 mv 10 V 1) 1) The allocations of voltage and ramp time specified in the table on page shall apply. RE 0119, edition: 01-0, Bosch Rexroth AG

10/10 VT-VRPA Valve amplifier Dimensions (dimensions in mm) REXROTH -1 HE (18,) Zw w1 w w w t 100 89 x w t VRPA Ø8 TE (0) 7 165 18 Project planning / maintenance instructions / additional information For more information, refer to document 0119-B. Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +9 (0) 9 5 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 0119, edition: 01-0

Valve amplifier VT-VRPA 11/10 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +9 (0) 9 5 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. RE 0119, edition: 01-0, Bosch Rexroth AG

VT-VRPA Valve amplifier Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +9 (0) 9 5 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 0119, edition: 01-0