NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Similar documents
NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.


71332 LED Dusk To Dawn (Area Light)

Eternal Shine Technology Co.,Ltd. EST

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

Cat# LED High Bay

QPL ID # PLG2YNJ831VZ

RoHS. Model: VAC 50/60HZ.83A Max 100W

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

Cat# 71440A LED Classic Large Wall-Pack

Dimming: PWM/TIME/0-5V/0-10V. RoHS


Cat# 71146A 150W Trunion Mount

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

71352A QPL ID # PLT2P2L2UNWR. RoHS

RoHS QPL ID # PLC6V1PABNUJS

Morris Products 53 Carey Road, Queensbury, NY 12804

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Cat# LED Classic MINI Wall-PACK

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Cat# LED Wall-PACK

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

LM Test Report

LM Test Report

LM Test Report

LM Test Report

Photometric Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

LM Test Report

Photometric Test Report

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Photometric Test Report

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

Photometric Test Report

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Transcription:

LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K Model Different: All construction and rating are the same, except CCT Test & Report By: GarmanMo Engineer: Garman Mo Date: Sept 18,2016 Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Address Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 10

Report No.: GZE160819-C 1.1 Product Information: Organization Name LED Waves, Inc. Brand Name Model Number LWQR2x2-40W-4000K, LWQR2x2-40W-5000K SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Linear Retrofit Kits for 2x2 Luminaires Rated Voltage / Frequency 100-277Vac, 50/60 Hz Nominal Power 40W Rated Initial Lamp Lumen Declared CCT 4000K,4500K,5000K LED Manufacturer EVERLIGHT ELECTRONICS CO., LTD LED Model 67-21S Series Sample Number GZE160819-C1(4000K); C2(5000K) Luminaire Aperture (for downlights) in. Luminaire Length mm Luminaires Width mm Number of Units (modular products) N/A s Photo Address Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://w w w.standard-tech.com 2 / 10

1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction Aug.18,2016 Aug.24,2016 1. Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Electrical Parameters 1. IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products 2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products 3. CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources 4. CIE 15-2004 Technical Report Colorimetry 5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source 6. IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD25 1.3 Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Chromaticity Measurement Sphere-Spectroradiometer Method: Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the s pectral power distribution taken at 5 nm intervals over the range of 380 to 780 nm. 3) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 3 / 10

2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2016-08-24 Test Ambient: 25.2 º C Test Orientation As intended Stabilization Time (min) 90 Model Number LWQR2x2-40W-4000K Electrical Measurement in Lithonia 2GT8 lensed 2x2: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE160819-120.0 60 0.3046 35.97 0.9840 14.57 C1 277.0 60 0.1423 35.94 0.9119 19.23 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement in Lithonia 2GT8 lensed 2x2 - Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 82 R9 6 Frequency (Hz) 60 R2 92 R10 80 CCT (K) 4019 R3 96 R11 79 Duv -0.0003 R4 80 R12 62 Chromaticity (x, y) x=0.3793 y=0.3754 R5 82 R13 85 Chromaticity (u, v ) u'=0.2249 v'=0.5008 R6 88 R14 98 Color Rendering Index (CRI) 83.1 R7 84 R15 75 R9 6 R8 62 Photometric Measurement in Lithonia 2GT8 lensed 2x2 Goniophotometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 Total Luminous (lm) 4450.7 4447.6 >=2000 (-10%) Luminous Efficacy (lm/w) 123.73 123.75 Standard: >= 100(-3%) Zonal lumens in the 0-60 zone (%) 85.5 >=75(-3) SC: 0-180 (if applicable) 1.22 1.0-2.0(±0.1) SC: 90-270 (if applicable) 1.15 1.0-2.0(±0.1) Beam Angle ( ) 90.1 Center Beam Candle Power (cd) 2053 Premium: >= 125(-3%) Address Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 4 / 10

Spectral Power Distribution & Chromaticity Diagram Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens % Total Zone Lumens % Total 0-30 1,559.6 35% 0-40 2,468.0 55.5% 0-60 3,806.2 85.5% 60-90 636.2 14.3% 70-100 289.9 6.5% 90-120 2.0 0% 0-90 4,442.3 99.8% 90-180 7.8 0.2% 0-180 4,450.1 100% 0-10 194.1 4.4% 90-100 0.1 0% 10-20 551.9 12.4% 100-110 0.6 0% 20-30 813.6 18.3% 110-120 1.3 0% 30-40 908.4 20.4% 120-130 1.6 0% 40-50 791.5 17.8% 130-140 1.5 0% 50-60 546.7 12.3% 140-150 1.2 0% 60-70 346.4 7.8% 150-160 0.8 0% 70-80 217.2 4.9% 160-170 0.5 0% 80-90 72.6 1.6% 170-180 0.2 0% 5 / 10

Photometric Data 6 / 10

7 / 10

2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2016-08-24 Test Ambient: 25.2 º C Test Orientation As intended Stabilization Time (min) 90 Model Number LWQR2x2-40W-5000K Electrical Measurement in Lithonia 2GT8 lensed 2x2: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE160819-120.0 60 0.3200 37.77 0.9836 15.17 C2 277.0 60 0.1493 37.74 0.9126 19.83 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement in Lithonia 2GT8 lensed 2x2- Sphere-Spectroradiometer Method : Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 82 R9 10 Frequency (Hz) 60 R2 90 R10 75 CCT (K) 5037 R3 94 R11 83 Duv 0.0036 R4 83 R12 62 Chromaticity (x, y) x=0.3447 y=0.3585 R5 83 R13 84 Chromaticity (u, v ) u'=0.2085 v'=0.4879 R6 85 R14 97 Color Rendering Index (CRI) 84.0 R7 87 R15 77 R9 10 R8 67 Photometric Measurement in Lithonia 2GT8 lensed 2x2 Sphere-Spectroradiometer Method : Parameter Result DLC V4.0 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 Total Luminous (lm) 5004 5001 >=2000 (±10%) Luminous Efficacy (lm/w) 132.49 132.51 Standard: >= 100(-3%) Premium: >= 125(-3%) Address Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 8 / 10

Spectral Power Distribution & Chromaticity Diagram 9 / 10

3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R-336 2 meter Integrating Sphere 2016-07-01 2017-06-30 ST-R-331 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30 D204 Standard Lamp 2016-07-01 2017-06-30 PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30 EE-09 Goniophotometer system 2016-07-01 2017-06-30 D908S Standard Lamp 2016-07-01 2017-06-30 PF210 Power Meter for Goniophotometer 2016-07-01 2017-06-30 ST-R-181A Temperature Tester 2016-07-01 2017-06-30 Uncertainty: Photometric Measurement (Sphere):1.74% Chromaticity Measurement(Sphere):14.3K Photometric Measurement(Goniophotometer):1.62% ****** END OF REPORT ****** 10 / 10