LM Test Report

Similar documents
LM Test Report

LM Test Report

LM Test Report

LM Test Report

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

REVOLUTION LIGHTING TECHNOLOGIES INC

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

Eternal Shine Technology Co.,Ltd. EST

Cat# LED Wall-PACK

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Photometric Test Report

Cat# LED High Bay

Cat# 71440A LED Classic Large Wall-Pack

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Cat# 71146A 150W Trunion Mount

71352A QPL ID # PLT2P2L2UNWR. RoHS

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

QPL ID # PLG2YNJ831VZ

Photometric Test Report

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Photometric Test Report

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Photometric Test Report

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

Morris Products 53 Carey Road, Queensbury, NY 12804


Cat# LED Classic MINI Wall-PACK


LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

NVLAP LAB CODE:

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

IES LM Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Approved Method:Electricaland Photometric

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Approved Method:Electricaland Photometric

Photometric Test Report

Transcription:

LM-79-08 Test Report For IRICO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH) 22AP3240A (CLC/WLC FPL22-840-32W-130LW-UNV-DIM1-WH) 22AP3250A (CLC/WLC FPL22-850-32W-130LW-UNV-DIM1-WH) Representative (Tested) Model: 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH) Model Difference: All is the same construction, except CCT Prepare By: Review By: Engineer: Leo Liu Technical Lead: Vincent Yuan Date: 2017-08-31 Date: 2017-09-01 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Page 1 / 11

Product Information: Client Name: IRICO AOTOM (HUBEI) PHOTOECTRICITY CO., LTD Brand Name: AOTOM Model Number: 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH) Product type: 2X2 Luminaires for Ambient Lighting of Interior Commercial Spaces Rating Input: 100-277V, 50/60Hz, 32W Declared CCT: 3500K LED Manufacturer: EVERLIGHT LED Model: 67-21S Forward current of LED Chip: 60mA Driver Model: LF-GMD045YS080U Date of Receipt Samples: 2017-08-11 Quantity of Receipt Samples: 1 Sample Number: 170811009-S1 Laboratory Information: Test Laboratory Address: 3F, No. 1 the 1 st North Industry Road, Songshan Lake Science & Laboratory Contact Name: Neil Zhong Laboratory Contact E-mail: Neil_ntc@163.com Report Information Issued Date of Test Report: 2017-09-01 Revised Date of Test Report: N/A Test Report No.: NTCR17080062 Remark (If applicable) N/A Technology Park, Dongguan, Page 2 / 11

Test Specifications: Date of Test 2017-08-30 Test item 1. Total Luminous Flux Reference Standard 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. THD and PF IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products CIE 13.3-1995 Method of Measuring and Specifying Color Rendering Properties of Light Sources CIE 15-2004 Technical Report Colorimetry Test Methods 1. Photometric and Electrical measurements Light Distribution Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 Vertical intervals. 2. Photometric and Electrical Measurements Integrating Sphere Method: Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm. 3. THD and PF measurements The sample was tested according to the ANSI C82.77-2002, the sample was operated at rated voltage and was stabilized before measurement. The total harmonic distortion were calculated from the digital power meter. Page 3 / 11

Integrating Sphere Test Results Test Condition: Test Ambient Test Humidity Orientation Stabilization Time Test Time 25.2 C 41 % Face Down 90 min 25 min Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor 120.0 60 0.2553 29.96 0.9777 Color Data: Parameter Result Special Color Rendering CCT (K) 3486 R1 80 R9 4 Color Rendering Index (CRI) 82.3 R2 90 R10 77 R9 4 R3 96 R11 79 Chromaticity, x 0.4067 R4 80 R12 64 Chromaticity, y 0.3928 R5 80 R13 83 Chromaticity u 0.2358 R6 87 R14 98 Chromaticity v 0.5123 R7 84 R15 73 Duv 0.00059 R8 60 - - Spectrum Diagram: Page 4 / 11

Goniophotemeter Test Results: Test Condition: Test Ambient Test Humidity Orientation Stabilization Time Test Time 25.5 C 36 % Face Down 90 min 25 min Electrical Data: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor 120.0 60 0.2553 29.96 0.9777 Goniophotometer Data: Parameter Result Total Luminous (lm) 3801.2 Total Luminous per foot (lm/ft) N/A Luminous Efficacy (lm/w) 126.89 Zonal Lumens Distribution (0-60 ) 83.4% Spacing Criterion (0-180) 1.36 Spacing Criterion (90-270) 1.42 Beam Angle ( ) 101.2 Luminous Intensity Distribution Diagram: Page 5 / 11

Isocandela Diagram: Page 6 / 11

Zonal Flux Diagram: Page 7 / 11

Luminous Distribution Intensity Data: THD and PF Measurement Test Result: Electrical Measurement: Voltage (Vac) Frequency (Hz) Current (A) Power (W) Power Factor ithd 277.0 60 0.1270 33.14 0.9421 10.92 Page 8 / 11

Photo of Sample: Page 9 / 11

Equipment List: Equipment ID Equipment Name Last Cal. Due Cal. NTC-F01-001 Goniophotometer System 2016-12-03 2017-12-02 NTC-F01-006 2.0 meter Integrating Sphere 2016-12-03 2017-12-02 NTC-F01-013 Standard Lamp 2016-12-27 2017-12-26 NTC-F01-031 Digital Power Meter 2016-12-05 2017-12-04 NTC-F01-019 Temperature & Humidity Meter 2016-11-28 2017-11-27 Page 10 / 11

*****END OF DATASHEET***** Page 11 / 11