Achieving accurate measurements of large DC currents

Similar documents
RAZTEC LINK CURRENT SENSOR TECHNICAL INFORMATION

Current Sensor: ACS750xCA-100

Application Note 5121

5. Transducers Definition and General Concept of Transducer Classification of Transducers

How to Select the Right Current Probe APPLICATION NOTE

APPLICATION NOTE. Using Current Sense Resistors for Accurate Current Measurement

Current Sensor: ACS755SCB-200

Current Sensor: ACS752SCA-050

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

Current Sense Application Note. Resistors. BI Technologies IRC Welwyn

AC/DC Current Probe CT6844/CT6845/CT6846

MECE 3320 Measurements & Instrumentation. Data Acquisition

Ammeter shunt resistors find renewed demand in renewable energy applications

TABLE 1 - SPECIFICATIONS PARAMETER CSM2512 CSM3637

Typical Application VCC IP+ ACS755 GND C F 3 R F

Current Sensor: ACS750xCA-050

Application Notes. Current Measurement SENSING MAGNETIC FIELD FROM A CURRENT-CARRYING WIRE Axis of sensitivity. Direction of current flow

Balanced Constant Current Excitation for RTD Sensor Measurements

ni.com Sensor Measurement Fundamentals Series

Page ENSC387 - Introduction to Electro-Mechanical Sensors and Actuators: Simon Fraser University Engineering Science

MAS.836 HOW TO BIAS AN OP-AMP

Current Sensor: ACS754SCB-200

Current transducer FHS 40-P/SP600

RF and Optical Bolometer

Common-emitter amplifier, no feedback, with reference waveforms for comparison.

± 0.5 % (1 m to < 2 m ) ± 0.1 % (2 m to 200 m ) Temperature Coefficient. ± 25 ppm/ C (1 m to < 3 m ) Max. (- 55 C to C,

EEE 432 Measurement and Instrumentation

Current Sensor: ACS754xCB-100

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Introduction to NVE GMR Sensors

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

SPECIAL REPORT: RENEWABLE ENERGY (PG29) January/February 2012

Dynamic calculation of nonlinear magnetic circuit for computer aided design of a fluxgate direct current sensor

Custom Resistors for High Pulse Applications

Resistance Value. Interloop capacitance. reduction. in series. Mutual inductance. reduction. due to change in current direction

technicalnote Implementing Advanced Cold-Junction Compensation Techniques to Improve Temperature Measurement Accuracy Headline Type K Thermocouple

FGM-series Magnetic Field Sensors

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Electronic Instrumentation and Measurements

Calibration Technique for SFP10X family of measurement ICs

Chapter 7. Response of First-Order RL and RC Circuits

High Common-Mode Voltage Difference Amplifier AD629

Interface to the Analog World

Application Note: AnadigmApex Thermocouple Solution, Sensor linearization

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

Digitally Controlled Crystal Oven. S. Jayasimha and T. Praveen Kumar Signion

Feb. 1, 2013 TEC controller design experts offer tips to lower the cost and simplify the design of the devices, and to increase their ease of use.

225 Lock-in Amplifier

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

Bridge Measurement Systems

BSNL TTA Question Paper Control Systems Specialization 2007

150mA, Low-Dropout Linear Regulator with Power-OK Output

Maconic Shunt Resistors

Guide for Choosing Resistors that are Exposed to Different Stresses

DUAL STEPPER MOTOR DRIVER

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

Signal Conditioning for MEAS Pressure Sensors

Advanced electromagnetism and electromagnetic induction

High-side Current Sensing Techniques for the isppac-powr1208

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

Experiment 1: Amplifier Characterization Spring 2019

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

The Physics of Single Event Burnout (SEB)

Driving Strain-Gauge Bridge Sensors with Signal- Conditioning ICs

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ABB flowmeter technology FSM4000 AC-excited magmeter

Discontinued Product

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

High Accuracy 8-Pin Instrumentation Amplifier AMP02

UNIT II MEASUREMENT OF POWER & ENERGY

ECE 363 FINAL (F16) 6 problems for 100 pts Problem #1: Fuel Pump Controller (18 pts)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

200 ma Output Current High-Speed Amplifier AD8010

Limited Availability Product

Using Optical Isolation Amplifiers in Power Inverters for Voltage, Current and Temperature Sensing

Advantages of Analog Representation. Varies continuously, like the property being measured. Represents continuous values. See Figure 12.

Inductive Sensors. Fig. 1: Geophone

Typical Application VCC IP+ ACS755 GND C F 3 R F

Chapter 2 Analog-to-Digital Conversion...

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Figure 4.1 Vector representation of magnetic field.

CQ-3 Series Current Sensor Application Note

IC Preamplifier Challenges Choppers on Drift

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

Thermocouple Measurement Using AI-225/AI-207 App Note # United Electronic Industries, Inc. All Rights Reserved.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Voltage Charge Pumps Deliver Low EMI

ECEN 5014, Spring 2009 Special Topics: Active Microwave Circuits Zoya Popovic, University of Colorado, Boulder

SGM8957-1/SGM V, Micro-Power CMOS Zero-Drift Operational Amplifiers

High Precision Current Measurement for Power Converters

Application Information

Sendyne SFP101EVB-LAB Signature Series

Fast IC Power Transistor with Thermal Protection

Fluxgate Magnetometer

MODERN ACADEMY FOR ENGINEERING & TECHNOLOGY IN MAADI

OUTPUT UP TO 300mA C2 TOP VIEW FAULT- DETECT OUTPUT. Maxim Integrated Products 1

Driver Amplifier for 7 Tesla MRI Smart Power Amplifier

Transcription:

Achieving accurate measurements of large DC currents Victor Marten, Sendyne Corp. - April 15, 2014 While many instruments are available to accurately measure small DC currents (up to 3 A), few devices are capable of accurate measurements (better than 1%) of DC currents in ranges that extend beyond 50 A. Such large current ranges are typical of the loads in electric vehicles (EVs), grid energy storage, and photovoltaic (photoelectric) renewable energy installations, to name a few. Furthermore, such systems need to accurately predict state of charge (SOC) of the associated energy storage batteries. As SOC estimation can be derived from current and charge (Coulomb counting) measurement, accurate data is a necessity for precise SOC estimation. In general, any system for current or charge measurements is designed to include built-in data acquisition attributes, such as suitable amplifiers, filters, analog-to-digital converters (ADCs), etc. A current sensor would sense the current; the output of a current sensor may require a circuit that converts its output into a usable form (i.e. voltage). The signal is filtered with a view of reducing electromagnetic and radio frequency interference; it s then amplified and digitized. Each current data sample may be multiplied by the appropriate time interval and accumulated (through digital calculations) for charge value. Alternatively, if digitization is performed at a constant and stable frequency, the current samples are first accumulated, and then multiplied by an appropriate time interval only when the accumulated charge value is read-out or utilized in some way. Selecting an appropriate minimum Nyquist sampling rate and utilizing sufficiently narrow anti-aliasing filters in front of the ADC also require consideration.

Figure 1. The signal chain of a typical modern current measurement system Available Sensor Technologies for Large Current Measurements Two sensor technologies are most commonly used for measurements of large current. The first of these techniques senses the magnetic field encircling the conductor that carries the current. The second technique measures the voltage drop across a resistor (often called a current shunt) that carries the current (and thus charge) to be measured; this voltage drop follows Ohm s law (V = I R). One device used for high current measurements is generally known as the Hall-effect current sensor; it incorporates a current-carrying element in which a voltage differential exists at the element s sides that is perpendicular to the direction of the current and perpendicular to the direction of the external magnetic field when both are applied to such element. The Hall-effect voltage differential has a low value in ordinary metals. Note that not all DC current sensors that measure the magnetic field around the current-carrying conductor are based on Hall Effect. We ll explain the differences shortly. High-Current Hall-effect Sensors High-Current Hall-effect Sensors To make a current sensor with a Hall-effect device, the magnetic field that surrounds the current flowing in a conductor is concentrated by a magnetic core that contains a slot with the actual Hall element. Comparatively small dimensions of the slot (as related to the whole length of the magnetic path) create a magnetic field that is nearly uniform and perpendicular to the plane of the Hall element. When the Hall element is energized with current, a voltage is produced that s proportional to that excitation current and to the magnetic field in the core. The Hall voltage is amplified and presented at the output of the current sensor.

Figure 2. Diagram of magnetic field around conductor, linear open-loop Hall-effect sensor, and closed-loop sensor Since there s no galvanic connection between the current-carrying conductor and the magnetic core (the only coupling being magnetic), the sensor is naturally isolated from the circuit being measured. The current-carrying conductor may have very high voltage potentials while the output of Hall-effect current sensors can be safely connected to grounded circuits or to circuits that are at an arbitrary potential relative to the current-carrying conductor. It s relatively easy to provide clearance and creepage values that satisfy the most demanding safety standards. However, such linear sensors have some shortcomings. Perhaps the least of them is the fact that Hall-effect sensors require constant excitation current. Furthermore, the amplification and conditioning circuits that process the signals from Hall-effect elements typically consume significant amounts of energy. Of course, depending on application, this may or may not be significant. Nevertheless, the energy consumption of Hall-effect sensors that continuously measure the current can t be reduced to micro power levels. Hall-effect Sensors: High drift, Small Usable Operating Temperature Range Because the output of the typical linear sensor is ratiometric (it depends not only on the strength of the magnetic field being measured, but also on the value of the excitation current), stability of the excitation current greatly affects both the magnitude of the measured current and zero offset when there is no current flow. Typically, both depend on the supply voltage s stability and temperature changes (since resistance of the Hall sensing element that influences the excitation current and Hall voltage itself depend on the operating temperature). A variation of the sensor where excitation current is measured and factored into the output is possible; however it requires precision external components and a larger processing circuit. Moreover, the Hall voltage is a nonlinear function of the sensed magnetic field. This further adds to

the sensor s inaccuracies. Because different errors arise under different conditions, most linear Hall Effect device makers separate the total error into many individual components. Sometimes it s not easy to calculate the total combined error. Closed-Loop Current Sensor Closed-Loop Current Sensor To combat the non-linearity of the Hall sensing element, a technique has been developed that relies on detection of the absence or sign of the magnetic field in the sensing core, rather than on measurement of the magnitude of such magnetic field. In addition, it frees the measurements from the errors due to unstable excitation current for the Hall element. A winding is added on the magnetic core that can introduce a magnetic field opposite in sign, but exactly equal to the field produced by the current being measured. The Hall sensing element is now only used to detect the magnetic field s sign, and not its magnitude. The winding works in a circuit with an op amp that maintains such a current in this compensation winding that the perceived

magnetic field by the Hall sensor is zero. The current in the compensation winding is many times (perhaps over 1000) smaller than the current in the conductor being sensed. This is achieved simply by making the compensation winding with many turns on the magnetic core; the number of turns is precisely controlled. Such current sensors are often called closed-loop due to the location and to the action of the compensation winding in the op amp s feedback loop. Conversely, the simple linear Hall-effect sensors described earlier are often called open loop, signifying the absence of feedback action in their operations. In a Hall-effect device, the (offset) error in detecting zero magnetic fields can t be reduced to an arbitrarily-small value, due to various drifts, and mostly due to temperature dependency. This is why some of the higher-performance current sensors operate with technologies that don t rely on the Hall effect. However, they may still be commonly called Hall-effect simply due to visual similarity of their housing to Hall-effect devices. Other Magnetic Field Detectors In non-hall devices, sensors based on various physical phenomena may perform the function of the magnetic-field detector. One such technology is based on the magnetoresistance effect, the change of the sensor s resistance when a magnetic field is applied to it. Another technology for magnetic-field detectors relies on nonlinear properties of ferrites in respect to the relationship between the magnetic field strength (denoted by H), magnetic flux density (denoted by B), and specifically on a phenomenon called saturation. When the H field increases, the B flux density eventually reaches a point where it can no longer increase significantly this point is called saturation. Some materials have been specifically formulated to have quite low levels of saturation. These are used in devices called fluxgates. Effectively, a fluxgate-based sensor can convert a constant magnetic field into a gated or chopped magnetic field that alternates between the full amount and almost zero. Such magneticfield changes are readily picked up by a winding on a core, and then easily amplified by an AC amplifier. A value that s proportional to the sensed constant magnetic field is recovered using socalled synchronous detection (since the circuit itself controls the chopping action). It should be clear that the complexities of the sensor s mechanical construction and accompanying circuit are much higher for the closed-loop sensors. Furthermore, they possess a significant operational difficulty application of the measurement current while the sensor isn t energized or the compensation winding circuit is open due to a loose connection to the external sense resistor

results in the typically irrecoverable upset of the offset and gain specification. As the compensation winding can t counteract the magnetic field from the sensed current, the magnetic components in the sensor acquire persistent magnetization. Precision Resistor Needed Precision Resistor Needed The output signal of a closed-loop sensor is simply the current in the compensation winding (that s the specific number of times smaller than the current being measured). This current would be normally converted to a voltage for further processing and digitization. A simple resistor could be used for this purpose. However, the accuracy and stability of this resistor will directly affect the accuracy and stability of the closed-loop current sensor. A closed-loop sensor that has a specified basic accuracy of 0.0001 % is quickly reduced to 1 % accuracy by using a 1 % sensing resistor. Procurement of resistors that are better than 0.01 %, even when operated in a narrow temperature range, can be difficult in commercial quantities. High-current Shunts As mentioned previously, the second technique for current measurements employs the voltage drop across a resistor. When a current is being determined according to Ohm s law, a unique set of concerns applies, depending on the current s magnitude. For relatively low currents, the shunt s voltage drop can be made quite large, as to overcome any errors due to sensing connections and temperature differentials created by the passing current due to heat dissipation in the shunt, or from the operating environment. However, for currents above 50 A, the heat dissipation and thermoelectric errors are of paramount importance. Likewise, since the shunt will invariably be heated up by the passing current and possibly operated in an unstable-temperature environment, the stability of the shunt s resistance in respect to temperature is particularly significant. Physical Shunt Composition At a first glance, the shunt is simply a resistor. A quantity of a current-conductive material with suitable properties with respect to the level of the volume resistivity, its stability (with temperature and time), and appropriate mechanical outline, can be used as a shunt. A low-precision shunt can be exactly that a length of a wire or rectangular shape constructed from suitable alloy and simply

soldered (or somehow electrically attached) in series with current-carrying conductors. However, it would be nearly impossible to insert such a shunt into the circuit it s supposed to measure without affecting its resistance (due to a variable amount of solder on the joints, or mechanical details of its attachment). Moreover, for stability reasons, it s advantageous to arrange the shunt in such a way that the current density in any given cross-section of the shunt is mostly uniform. This prevents formation of so-called hot spots, defined as areas within a shunt that have a higher temperature than the rest of the material. In addition to simple resistance changes, the high temperature rise in the hot spots may bring the resistive material to its annealing temperature, at which point its resistivity (achieved by careful control of chemical composition and processing) may start to change permanently. Even if the actual presence of hot spots wasn t detrimental to the accuracy, it s not possible to assure that they ll form in exactly the same places as at the time the shunt was calibrated. Consequently, the shunt s design includes the means to equally distribute the current across the cross-section of the resistive material, or between individual parallel-connected resistive sections and inside each of those sections. That s why most of the higher-precision shunts are constructed in three distinct parts: two areas that are the terminals for connections into the circuit (almost invariably made from thick highconductivity material, such as copper), and one section or multiple parallel sections that constitute most of the shunt s resistance. The two terminal areas are jointed with the resistive portion or portions using welding or metallurgical processes, with very uniform seams. The material for the resistive (also called active) part of a precision shunt must have the attribute of low dependency of resistance on the temperature. Because of its suitable resistance and low Temperature Coefficient of Resistance (TCR), one of the most common alloys used for precision shunts is Manganin, developed in 1892 by Edward Weston (well-known for his development of the electrochemical cell, the Weston Cell). Heat Dissipation in Shunts Heat Dissipation in Shunts Heat dissipation in a resistor is proportional to the square of the current and to the resistance (W = I2 R). For example, a 1-mO shunt would dissipate 2.5 W of heat with 50 A current, a manageable amount with moderate heat sinking and in still air. Conversely, at 1 ka, the same shunt would dissipate 1 kw of heat, an amount that would necessitate large physical size and possibly forced air (or liquid) cooling.

Figure 3: Heat dissipation in a shunt vs. resistance and current Figure 4: Heat dissipation in a shunt vs. full-scale output voltage and current It should be clear from the above charts that the only method for reducing the heat dissipation in a

shunt, for a given current, is to reduce its resistance. However, this would also reduce the measured voltage across the shunt, and the signal will become more sensitive to errors developing in the shunt and in the sensing circuit, with resulting degradation of accuracy in low currents. Error Sources in Shunt Current Measurement High operating temperature and temperature differentials in a shunt adversely affect both gain and offset errors. For shunt-based measurement systems, not only does the ambient temperature come into play, but also the measured current itself, as high currents heat the shunt. While the shunt s resistive (active) portion is made from a material with low TCR, high operating temperature will invariably instigate a resistance change from the calibrated value, however small that change may be. This produces sensitivity (gain) errors. Due to dissimilar materials used in the shunt s construction (i.e. materials of the connecting terminals and sensing wires are not typically the same as the shunt s resistive portion), so-called thermoelectric errors (such as the Seebeck Effect) exist that affect the offset error (reported current reading when the actual current is zero). Because the shunt s heating effects can be measured and can be expressed in a predictable way, some shunt-based systems can compensate for the shunt s thermal effects that lead to both offset and gain errors. In any case, when designing a shunt-based current measurement system as described in Figure 1. The signal chain of a typical modern current measurement system, care should be taken to select components which can provide the lowest errors and drifts. Selecting the Right Measurement Method For measurements of large DC currents, the fundamental issues are the accuracy of the measurements and costs. Other important considerations include operating environment (especially temperature range), power consumption, size, and durability (considering possible overloads, transients, and un-energized operations). To determine accuracy of the measurements for any given

method, it s important to consider all possible error sources, over all relevant extremes of the operating conditions. Table 1: Comparison of Current Sensors