Measuring current transformers of the W AB(P) series

Similar documents
Measuring current transformers of the W B series

Measuring current transformers of the W, W series

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

ISOMETER IRDH575. Approvals

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Power Quality and Energy Measurement PEM533

Measuring current transformer for universal measuring devices

Power Quality and Energy Measurement PEM575

RCMS460 and RCMS490 Series

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

PEM353. Universal measuring device

LINETRAXX RCMB42. AC/DC sensitive residual current monitor for electric vehicle charging systems

Power Quality and Energy Measurement PEM735

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Installation / Monitoring Technique

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt

Power Quality and Energy Measurement PEM330/PEM333

E-STOP relays, safety gate monitors

Power Quality and Energy Measurement PEM575

ISOMETER iso685-d-p. Device features

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

ISOMETER Headline IR /IR

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Technical data Insulation fault location system Device components

Liquid level monitoring relay CM-ENS.2x

AC/DC sensitive residual current monitoring module RCMB121-

Type CP-S, CP-C & CP-A Switch mode

The Power in Electrical Safety

Three-phase monitoring relay CM-PFS

QUINT-PS-24DC/24DC/10

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Transformers, Power Supply Units and Socket Outlets

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

400 (±2,5 V/ V/ ,3% V4A

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

AC/DC sensitive residual current monitoring module RCMB121-

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Three-phase monitoring relays CM-PFE and CM-PFE.2

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Electronic timer CT-MFS.21

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic Circuit Breaker with reset input ESS20-1..

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

LINAX 4000L Continuous-line recorder

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MINI-PS AC/2X15DC/1

QUINT-PS AC/24DC/40

E-STOP relays, safety gate monitors

Installation- / Monitoring Technique

Electronic timer CT-SDS.22

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Subject to changes 11/2003 Page 1/7

MINI-PS AC/24DC/1.3

PHOENIX CONTACT

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

NS..S contactor relays - with spring terminals AC operated

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Wind Transmitter First Class Advanced Classified according to IEC ( )

E-STOP relays, safety gate monitors

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

PHOENIX CONTACT

Solid State Relay, 1-phase

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Operating instructions Fail-safe delay timer AZS About this document. Content

QUINT-PS/ 3AC/24DC/10

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Overcurrent Protection / 7SJ45

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Data sheet. W-Series WDU 4 BL

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Product overview. Residual current monitoring. AC, pulsed DC and AC/DC sensitive residual current monitors RCM, RCMA, RCMB

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Data sheet. W-Series WDU 10

Controls Contactors and Contactor Assemblies Special Applications

Accessories. Accessories

W DATA SHEET Current Transformer 40 x 10, A

MINI MCR-SL-UI-f(-SP)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

SINEAX B 811 Power Pack with additional Functions

Data sheet. W-Series WDU 2.5

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Output of three-phase motors at 50 Hz and 400 V

Data sheet. W-Series WDU 2.5 RT

Switching power supplies CP range, Linear power supplies CP-L range. Content

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Transcription:

Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017

Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB series are measuring current transformers which in combination with devices of the RCMA420/423 resp. RCMS460/490 series convert AC and DC currents into evaluable measurement signals. Connection to the respective devices is via a five-wire or six-wire cable. The CTs can be used in DC, AC, and 3(N) AC systems. If the measuring current transformers are to be connected to an RCMS460/490 system, one AN420 or AN110 power supply unit is required for six measuring current transformers each. The measuring current transformers of the W35ABP and W60ABP series feature an integrated Mumetal shield. W60AB measuring current transformer Device features W20AB W60AB for AC/DC sensitive RCMA420 residual current monitors W20AB W210AB for RCMS460/490 residual current monitoring systems or for RCMA423 residual current monitors W35ABP and W60ABP for RCMS460/490 and for RCMA420/423 residual current monitors. For use in systems where shortterm load currents are likely to occur. Standards W AB series measuring current transformers comply with the device standards: IEC 61869-1. Installation instructions Make sure that all live conductors are routed through the measuring current transformer Do not route shielded conductors through the measuring current transformer As a general principle, the PE conductor und low-resistance conductor loops must not be passed through the measuring current transformer! Otherwise the applied AC/DC sensitive measurement technique can result in high currents being induced into the conductor loop. Approvals 2 W-AB(P)_D00074_02_D_XXEN/07.2017

W AB(P) series measuring current transformers Wiring diagram I( n) 500 ma I( n) 500 ma W AB(P) I( n) > 500 ma W AB(P) I( n) > 500 ma Connection to the RCMS460/490 residual current monitor using the WXS- connecting cable. Colour coding for WXS and WX : k = yellow, l = green, -12 V = black, GND = brown, +12 V = red, Test (T) = orange Connection to the RCMA420/423 residual current monitor using the WX- connecting cable. W-AB(P)_D00074_02_D_XXEN/07.2017 3

W AB(P) series measuring current transformers Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage Rated impulse voltage/pollution degree Supply voltage Supply voltage U S Operating range of U S Power consumption CT circuit Rated primary residual current W20AB Rated primary residual current W35AB(P) W60AB(P) Rated primary residual current W120AB Rated primary residual current W210AB Rated continuous thermal current Icth Rated short-time thermal current Ith Rated dynamic current Idyn 800 V 8 kv/3 DC ± 12 V 0.95 1.05 x U S 2.5 VA 10 500 ma 10 ma 10 A 100 ma 10 A 300 ma 10 A 40 A 2.4 ka/1 s 6.0 ka/40 ms Environment/EMC EMC IEC 62020 Operating temperature -10 +55 C Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K5 (except condensation and formation of ice) Long-time storage (IEC 60721-3-1) 1K5 (except condensation and formation of ice) Classification of mechanical conditions IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-time storage (IEC 60721-3-1) 1M3 Connection Type of connection Connection RCMA/RCMS measuring current transformers plug-in connectors see table connecting cables Other Degree of protection, internal components (IEC 60529) IP40 Degree of protection, terminals (IEC 60529) IP20 Screw mounting fillister head screw M5 acc. to DIN7985 DIN rail mounting (W20AB W60AB(P) only) Snap-on mounting Flammability class UL94 V-HB Documentation number D00074 Ordering information Mounting Inside diameter Type Art. No. Mounting brackets, DIN rail Mounting brackets Connecting wires 20 mm W20AB B98080008 35 mm W35AB B98080016 W35ABP B98080051 60 mm W60AB B98080026 W60ABP B98080052 120 mm W120AB B98080041 210 mm W210AB B98080040 For device Length Type Art. No. 1 m WX-100 B98080503 RCMA420/423 2.5 m WX-250 B98080504 5 m WX-500 B98080505 10 m WX-1000 B98080511 1 m WXS-100 B98080506 RCMS460/490 2.5 m WXS-250 B98080507 5 m WXS-500 B98080508 10 m WXS-1000 B98080509 Control cable LiYY flexible, 6 x AWG 20 (6 x 0.56 mm²), approved by UL 2464 Accessories Type designation For device Art. No. Snap-on mounting Suitable system components Type designation Power supply units W20AB, W35AB(P) W60AB(P) B98080501 B98080502 Supply voltage US Type Art. No. AC 16 72 V/DC 9,6 94 V DC, AC 42 66 Hz AC/DC 70 276 V DC, AC 42 460 Hz AC 20 60 V; DC 18 72 V DC, AC 50 60 Hz AC 90 264 V; DC 100 353 V DC, AC 50 60 Hz AN420-1 AN420-2 AN110-1 AN110-2 B74053099 B94053100 B94053101 B94053102 Selection list Type RCMA420 RCMA423 RCMS460/490 W20AB W35AB(P) W60AB(P) W120AB W210AB 4 W-AB(P)_D00074_02_D_XXEN/07.2017

W AB(P) series measuring current transformers Dimension diagram Dimensions (mm) Weight Type A B C D E F G H W20AB 30 56.3 50 76.4 48.5 ø 20 29.8 16.4 180 g W35AB(P) 30 79.2 62 99.5 55 ø 35 41.7 20 350 g W60AB(P) 37 116.4 79 135 67 ø 60 60.4 24 570 g W120AB 37 191.5 116.5 210 67 ø 120 98 33.5 1920 g W210AB 45 304.5 173 323 80 ø 210 154.5 45 5800 g Tolerance: ± 0.5 mm Mounting details Screw mounting with mounting brackets: W20AB, W35AB(P), W60AB(P) Snap-on mounting on DIN rail, for vertical or horizontal mounting: W20AB, W35AB(P), W60AB(P) Screw mounting: W120AB, W210AB Dimensions (mm) Type A B C D W35 (mounting with 2 mounting brackets diagonal) 49 31.4 65 18.6 W35AB(P) (mounting with 2 mounting brackets diagonal) 49 49.8 65 12.1 W60AB(P) (mounting with 3 mounting brackets diagonal) 56 66 72 17.7 W120AB (screw mounting) 81 103 90.6 65 W210AB (screw mounting) 98 180 117.1 83 Dimensions in mm Tolerance for screw mounting with mounting brackets: ± 1.5 mm Dimensions (mm) Type A B W20AB 43.5 32 W35AB(P) 43.5 32 W60AB(P) 50 39 W-AB(P)_D00074_02_D_XXEN/07.2017 5

Installation instructions Do not pass shielded cables through the measuring current transformer. As a general principle, the PE conductor and low-resistance conductor loops must not be passed through the measuring current transformer! It is important that the leads are passed through the measuring current transformer in the right direction Bender GmbH & Co. KG P.O. Box 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de * * Distance to the 90 angle = 2 x transformer outside diameter Bending a lead is only permissible with a certain distance to the current transformer * Never pass a PE conductor through the measuring current transformer Make sure that all currentcarrying leads are passed through the measuring current transformer The leads must be aligned with the centre of the measuring current transformer BENDER Group W-AB(P)_D00074_02_D_XXEN / 07.2017 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing.