APA Performance Rated Rim Boards

Similar documents
THE ENGINEERED WOOD ASSOCIATION

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Featuring TJ Rim Board and TimberStrand LSL

LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

Joint Evaluation Report

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2018

Nailed Structural-Use Panel and Lumber Beams

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

SDWH TIMBER-HEX Screw

Load Tables, Technical Data and Installation Instructions

Building for High Wind Resistance in Light-Frame Wood Construction

Glulam Connection Details

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Introduction. to Wall Bracing

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

ESR-2913* Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

CITY OF LOS ANGELES CALIFORNIA

ICBO ES ER-5598 n HUD MR 1310 DSA PA-123 n LAC RR25448 n CCMC R. Limit States Design

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

MAT105: Floor Framing


Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

3.1 General Provisions

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

VERSA-LAM. An Introduction to VERSA-LAM Products

Sections & Details VOCABULARY

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

A. Rough carpentry includes but is not limited to the following:

Prescriptive Residential Wood Deck Construction Guide Based on the 2006 International Residential Code

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

ICC-ES Evaluation Report

APPLICATION FOR A BUILDING PERMIT

Product Information & Installation Instructions

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

SECTION ROUGH CARPENTRY

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

A. Product Data: For each type of process and factory-fabricated product indicated.

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng.

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Structural Criteria for Residential Rooftop Solar Energy Installations

Residential I-Joist & LVL INSTALLATION GUIDE

ICC-ES Evaluation Report

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Lateral Tension System

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: EVALUATION SUBJECT:

Wood Connections. Presented by: Karyn Beebe, P.E.

Section Downloads. Terminology Outline. Industry Standards/ Publications. American Softwood Lumber Standard ANSI/TPI 1. Section 02: Terminology

FASTENERS BUILDING DEPARTMENT

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

SECTION ROUGH CARPENTRY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

Backer Block (both sides) of web with single RFPI Joist. (12) - 10d. Backer Block. each side. 2 min. 2 min.

Structural Criteria for Residential Flush-Mounted Solar Arrays

Wall Form Design Part I

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L

Vertical Offset Base and Safety Rail System Installation Instructions

Continuing Education. Michelle Kam-Biron, S.E. Wood Products Council WoodWorks!

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

Structural Criteria for Residential Rooftop Solar Energy Installations

EWP Product Guide. For Use With Products Manufactured by. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2 LSSH35 THFI2514

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

SECTION ROUGH CARPENTRY

City of Virginia Beach, Virginia Typical Deck Details

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

Typical Deck Details

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS SECTION: STAPLES REPORT HOLDER:

Deck Design Guide. One and Two Family Residential Dwellings

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

EWP Product Guide. For Use With Products Manufactured by.

Changes in the 2001 NDS for Wood Construction

RIDGE-JOIST CONNECTION 12/12 maximum slope

Exterior Wall Fastener Schedule

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

ROOF-CEILING CONSTRUCTION

ROOF-CEILING CONSTRUCTION

Transcription:

D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top plate and bottom plate of two wall sections. The Rim Board must match the depth of the framing members between floors or between the floor and foundation to function properly. In addition to supporting the wall loads, the Rim Board ties the floor joists together. It is an integral component in an engineered wood system because it transfers both lateral and vertical bearing forces. While lumber has been the traditional product used for Rim Boards, it is not compatible with the new generation of wood I-joists used in floor construction. With the increasing use of wood I-joists, a demand for compatible engineered wood Rim Boards has resulted. In this application, an engineered wood Rim Board is installed between the foundation sill plate and the floor under a wall section. The Rim Board matches the depth of the I-joists used in the floor framing. Table 1 Standard Sizes for APA Performance Rated Rim Boards Standard Sizes (a) Thickness (inches) 1 (b), 1-1/8 (b), 1-1/4, and 1-1/2 Depth (inches) 9-1/2, 11-7/8, 14, 16, 18, 20, 22, 24 Length (feet) 8 to 24 (a) All sizes may not be available. Check suppliers for availability. (b) Predominant thicknesses manufactured by APA members. APA Performance Rated Rim Boards can be manufactured using plywood, oriented strand board (OSB), glued laminated timber (glulam), or structural composite lumber (SCL), which is composed of laminated veneer lumber (LVL), laminated strand lumber (LSL), or oriented strand lumber (OSL). These engineered wood Rim Boards have less shrinkage than lumber and match the depth of wood I-joists and other engineered wood framing products. They are available in lengths up to 24 feet, depending on the product used. See Table 1. Most APA Performance Rated Rim Boards are structural-use panels that are manufactured in accordance with the Performance Standard for APA EWS Rim Boards and Voluntary Product Standards PS 1 or PS 2, or APA Standard PRP-108. Glulam Rim Boards are a resawn grade of glued laminated timber manufactured in accordance with the Performance Standard for APA EWS Rim Boards and ANSI A190.1. The Performance Standard for APA EWS Rim Boards meets or exceeds the requirements given in the ICC-ES Acceptance Criteria for Wood-Based Rim Board Products, AC124. A typical trademark for APA EWS Rim Boards is shown at right. RIM BOARD PLUS 1-1/8 INCH MILL 000 PRR-401 Rim Board is a registered trademark of APA The Engineered Wood Association.

2 As glued engineered wood products, APA Rim Boards have greater dimensional stability, higher strength, increased structural reliability, more consistent quality and a lower tendency to check or split than sawn lumber. Plus, APA Rim Boards are readily available in most markets in North America. Connection Require m e nts 1. Floor sheathing to APA Performance Rated Rim Board (See Figure 1) Use 8d nails (box or common) at 6 inches o.c. Caution: The horizontal load capacity is not necessarily increased with a decreased nail spacing. Under no circumstances should the nail spacing be less than 3 inches. The 16d (box or common) nails used to connect the bottom plate of a wall to the Rim Board through the sheathing do not reduce the horizontal load capacity of the Rim Board provided that the 8d nail spacing (sheathing-rim Board) is 6 inches o.c. and the 16d nail spacing (bottom platesheathing-rim Board) is in accordance with the prescriptive requirements of the applicable code. FIGURE 1 ATTACHMENT DETAILS WHERE RIM BOARDS ABUT 8d nails at 6" o.c. (typical) 1-1/2" (1) 8d nail top and bottom (typical) 8d nails h Rim Board joint Rim Board joint 8d toe-nails at 6" o.c. (typical) 8d common (0.131" x 2-1/2") or 8d box (0.113" x 2-1/2") nails may be used Rim Board Joint Between Floor Joists Rim Board Joint at Corner 1-1/2" APA recommends a minimum 3/8-inch panel edge distance be maintained when nailing. Calculations show that the tongue does not need to be removed for floor sheathing 7/8-inch thick or less when used in conjunction with Rim Boards of 1-1/8 inches or thicker. Some local jurisdictions, however, may require removal of the tongue at the edge of floor framing when nailing it to Rim Board. 2. APA Performance Rated Rim Board to I-joist (See Figure 1) Use two 8d nails (box or common), one each into the top and bottom flanges. This is typical for Rim Board having a thickness up to 1-1/8 inches. A larger nail size may be required by the I-joist manufacturer or for thicker Rim Board products. 3. APA Performance Rated Rim Board to sill plate Toe-nail using 8d (box or common) at 6 inches o.c. (see Figure 2). FIGURe 2 TOE-NAIL CONNECTION AT RIM BOARD Rim board Top or sole plate 30

3 4. Attachment of 2x lumber ledgers to APA Performance Rated Rim Board Use 1/2-inch-diameter lag screws (minimum nominal length of 4 inches) or 1/2-inch-diameter throughbolts with washers and nuts. In both cases, use a design value of 350 lbf per fastener if the Rim Board thickness is 1-1/8 inches or thicker, or 300 lbf per fastener if the Rim Board thickness is 1 inch (see Figures 3 and 4 and Table 2). Caution: The lag screw should be inserted in a lead hole by turning with a wrench, not by driving with a hammer. Over-torquing can significantly reduce the lateral resistance of the lag screw and should therefore be avoided. See the 2005 National Design Specification for Wood Construction (NDS) published by the American Forest & Paper Association for the appropriate size of clearance and lead holes. FIGURE 3 2X LEDGER TO RIM BOARD ATTACHMENT DETAIL Existing stud wall Rim Board Floor sheathing Wood I-joist Existing foundation wall 2" min. 1-5/8" min. 5" max. 2" min. Exterior sheathing Remove siding at ledger prior to installation Continuous flashing extending at least 3" past joist hanger 1/2" diameter lag screws or thru-bolts with washers Deck joist Joist hanger 2x ledger board (preservative-treated); must be greater than or equal to the depth of the deck joist FIGURE 4 FASTENER SPACING FOR DECK LEDGER Typical spacing (see Table 2) Lag screw or thru-bolt with washer 2" typical Stagger fasteners in 2 rows 2" typical Table 2 Fastener Spacing for Deck Ledger and APA Performance Rated Rim Boards Using 1/2-Inch-Diameter Lag Screws or Thru-Bolts with 15/32-Inch Maximum Sheathing (a) (Deck Live Load = 40 psf, Deck Dead Load = 10 psf) APA Rim Boards Joist Span (L) L 6' 6' < L 8' 8' < L 10' 10' < L 12' 12' < L 14' 14' < L 16' 16' < L 18' On-Center Spacing of Fasteners (b) 1-1/8" or thicker 28" 21" 16" 14" 12" 10" 9" 1" 24" 18" 14" 12" 10" 9" 8" (a) See Figure 3 for attachment details. Ledger shall be spruce-pine-fir or other wood species with a specific gravity of 0.42 or greater. (b) Lag screws and thru-bolts shall be staggered in accordance with Figure 4.

4 5. Lateral resistance of nails applied to the faces of APA Performance Rated Rim Board Calculate the lateral nail resistance based on the procedures given in the 2005 NDS and the following guidelines: a) If the APA Performance Rated Rim Board is made of OSB, use the bearing strength equivalent to Douglas fir-larch. b) If the APA Performance Rated Rim Board is made of plywood, use the bearing strength equivalent to Douglas fir-larch. The calculated lateral resistance should then be adjusted by a factor of 0.9. c) If the APA Performance Rated Rim Board is made of glulam, use the wood species of the layup combination. d) If the APA Performance Rated Rim Board is made of SCL, use the equivalent species published in the manufacturer s code report or APA Product Report. e) If the product information is unavailable, refer to the appropriate 2005 NDS design values applicable to Spruce-Pine-Fir. Applic ation Note s Standard sizes for APA Performance Rated Rim Boards are given in Table 1 and design capacities are given in Tables 3, 4 and 5. 1. APA Performance Rated Rim Boards spanning over openings Rim boards may be used to span openings up to 4 feet in length, depending on the applied loads on the opening. Table 5 gives the allowable load that can be carried by a single or double-ply Rim Board used in this application. If other loads outside the scope of Table 5 are to be considered, the allowable edgewise bending values of Table 4 may be used for design. When spanning openings, Rim Board end (butt) joints shall not occur over the opening or within 12 inches of the opening. Requirements for holes in Rim Board are detailed in APA Performance Rated I-Joists, Form EWS Z725. Table 3 Design Capacities For APA Performance Rated Rim Boards (a) H h (c) V (d) z (e) P (f) (lbf/ft) (lbf/ft) (lbf) (lbf) t min (b) depth (d) Limitation (in.) Grade (in.) d 24 d 16 16< d 24 d 24 d 24 Rim Board Rim Board Plus 1 180 3,300 1,650 300 3,500 1-1/8 180 4,400 3,000 350 3,500 1 N/A (g) N/A (g) N/A (g) N/A (g) N/A (g) 1-1/8 200 4,850 3,200 350 3,500 (a) These design values are applicable only to Rim Board applications in compliance with the connection requirements given in this document and shall not be used in the design of a bending member, such as joist, header, rafter, or ledger. All design values are applicable to the normal load duration (10 years) for wood products, except for the horizontal load transfer capacity (H), which is based on the short-term load duration (10 minutes). Design values may be adjusted for other load durations in accordance with the applicable code except that the bearing (vertical) load capacity (V) and concentrated vertical load capacity (P) are not permitted to be increased for any load durations shorter than the normal load duration (10 years). Toe-nailed connections are not limited by the 150 lbf/ft lateral load capacity noted for Seismic Design Categories D, E and F in Section 2305.1.4 of the IBC. (b) t min = Minimum thickness for design capacities listed. (c) H = The horizontal (shear) load transfer capacity based on attachment schedule specified in Figure 1. H is based on qualification tests and is not subject to the limitations per Section 2305.1.4 of the 2006 IBC. (d) V = The bearing (vertical) load capacity, which shall not be adjusted for load durations in accordance with the applicable code. (e) Z = The lateral resistance of a 1/2-inch-diameter lag screw. (f) P = The concentrated vertical load capacity based on 4-1/2-inch bearing length. The maximum concentrated load acting along any area of the floor sheathing above the Rim Board. The bearing load must be simultaneously satisfied along with the concentrated load capacity. See Application Note 4 for additional information. (g) The minimum thickness for APA Rim Board Plus is 1-1/8 inches.

5 2. APA Performance Rated Rim Boards used as fire blocking panels The minimum thickness of 1 inch for APA Performance Rated Rim Boards exceeds the minimum requirement of 23/32 inch published in the model building codes as long as the joints are backed by another APA Rim Board or a 23/32-inch structural-use panel. For fire-rated assemblies, refer to APA Data File, APA Rim Board in Fire Rated Assemblies, Form D350. 3. APA Performance Rated Rim Boards used in applications where a high lateral load transfer capacity is required When the applied lateral loads exceed the published horizontal load capacities of APA Rim Boards, add a commercially available specialty connector made by connector manufacturers between the Rim Board and framing or sole plate. This type of connector is installed using face nailing into APA Rim Board and has a typical lateral load capacity of 400 to 500 lbf per connector. Table 4 Allowable Edgewise Bending Properties for APA Performance Rated Rim Boards (a) Grade f (b) be e (c) e f (d) ve f (e) c e (psi) (psi) (psi) (psi) Rim Board and Rim Board Plus 600 550,000 140 550 (a) The tabulated values are applicable to Rim Boards when subjected to the normal load duration (10 years) and permitted to be adjusted for other load durations in accordance with the applicable code except for edgewise modulus of elasticity and compressive stress perpendicular to grain. (b) Allowable edgewise bending stress is applicable only to a span of 4 feet or less. The adjustment for volume effect is already included. For applications requiring a longer span over an opening, use glulam, I-joists, or SCL headers. (c) Allowable edgewise apparent modulus of elasticity. (d) Allowable edgewise shear stress, which is permitted to be increased to 270 psi for mat-formed panels such as OSB. (e) Allowable compressive stress perpendicular to grain based on 0.04-in. deformation. Table 5 (a, b, c, d, e, f) Allowable Load for APA Rim Board and Rim Board Plus Used as Headers (Load Duration factor = 1.0) Load Condition Size Span Span Size 24" 30" 36" 42" 48" 24" 30" 36" 42" 48" 1,180 790 560 420 330 1,330 890 630 470 370 1" x 9-1/2" 1-1/8" x 9-1/2" Min. End Bearing (in.) 3.0 3.0 3.0 1.5 1.5 3.0 3.0 3.0 1.5 1.5 2 plies 2,370 1,580 1,130 850 660 2 plies 2,660 1,780 1,270 950 740 Min. End Bearing (in.) 1" x 9-1/2" 3.0 3.0 3.0 1.5 1.5 1-1/8" x 9-1/2" 3.0 3.0 3.0 1.5 1.5 1,660 1,130 820 620 480 1,870 1,270 920 700 540 1" x 11-7/8" 1-1/8" x 11-7/8" Min. End Bearing (in.) 4.5 3.0 3.0 3.0 3.0 4.5 3.0 3.0 3.0 3.0 2 plies 3,320 2,260 1,640 1,240 970 2 plies 3,740 2,550 1,840 1,400 1,090 Min. End Bearing (in.) 1" x 11-7/8" 4.5 3.0 3.0 3.0 3.0 1-1/8" x 11-7/8" 4.5 3.0 3.0 3.0 3.0 2 plies 4,170 2,890 2,120 1,620 1,280 2 plies 4,690 3,250 2,390 1,820 1,440 Min. End Bearing (in.) 1" x 14" 6.0 4.5 4.5 3.0 3.0 1-1/8" x 14" 6.0 4.5 4.5 3.0 3.0 2 plies 4,940 3,780 2,770 2,120 1,670 2 plies 5,560 4,250 3,120 2,380 1,880 Min. End Bearing (in.) 1" x 16" 6.0 6.0 4.5 4.5 4.5 1-1/8" x 16" 6.0 6.0 4.5 4.5 4.5 (a) This table is for preliminary design use only. Final design should include a complete analysis. (b) Span = simply supported beam subjected to uniform loads only; span is distance measured between inside faces of opening; connect the 2-ply Rim Boards with a minimum of 3 rows of 8d box nails (0.113" x 2-1/2") at 6" on center for 11-7/8" or less in depth, and 4 rows of 8d box nails at 6" on center for deeper Rim Boards. Clinch the nails whenever possible. For side-loaded members, the connection may require modifications. (c) Service condition = dry. (d) Tabulated values represent total loads and have taken the dead weight of the Rim Board (assumed 45 pcf) into account. (e) Joints in Rim Board shall not be located within opening. (f) For larger openings, use glulam, SCL or other engineered wood products.

6 4. APA Performance Rated Rim Boards subjected to a combination of uniform and concentrated vertical loads First, the applied concentrated load shall not exceed the concentrated load capacity (P) of the Rim Board, based on a 4-1/2" bearing length over the floor sheathing attached to the top of the Rim Board. Second, the applied concentrated load shall be calculated as an equivalent uniform load based on the applied loading length increased by a 45 load distribution through decking and plate on both sides of the concentrated load, as applicable. The equivalent uniform load shall be added to the applied uniform load to determine the total applied uniform load, which shall not exceed the bearing load capacity (V) of the Rim Board. If the total applied uniform load exceeds the bearing load capacity (V), use appropriate squash blocks, double Rim Boards, or a higher grade of APA Performance Rated Rim Board to carry the concentrated vertical load. Example: A mechanical device distributes a weight of 3,000 lbf for a distance of 12 inches along the top of a 1-1/8- inch x 16-inch APA Rim Board through 23/32-inch floor sheathing. In addition to the mechanical device the Rim Board carries a uniform load of 2,000 lbf/ft. Check: a) Concentrated vertical load = 3,000 lbf < 3,500 lbf. OK. b) Equivalent uniform bearing load = 3,000 / [(12 + 2 * 23/32) / 12] = 2,680 lbf/ft. Total equivalent uniform bearing load = 2,680 + 2,000 = 4,680 lbf/ft > 4,400 lbf/ft. NG. Use APA Performance Rated Rim Board Plus that has an allowable bearing (vertical) load capacity of 4,850 lbf/ft, or use double Rim Boards.

We have field representatives in many major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying engineered wood products, contact us: APA Headquarters 7011 So. 19th St. Tacoma, Washington 98466 (253) 565-6600 Fax: (253) 565-7265 Product Support HELP Desk (253) 620-7400 E-mail Address: help@apawood.org Discl aimer The information contained herein is based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research and comprehensive field experience. Neither APA, nor its members make any warranty, expressed or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions or recommendations included in this publication. Consult your local jurisdiction or design professional to assure compliance with code, construction and performance requirements. Because APA has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. Form No. W345K/Revised July 2009