Reduced Voltage Starters

Similar documents
Reduced Voltage Starters

Starters + Enclosed Product

Starters + Enclosed Product

page 10/20 page 10/21 pages 10/21-10/22 page 10/22 page 10/23 none 1 or 2 1 push button extended head red 3 or 4 1 twist lock mushroom red

POWER PRODUCT Low Voltage Motor Starters Contents

Low Voltage Motor Starters

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b

Open Type Without Enclosure

3RA13, 3RA14 Contactor Assemblies

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

AEB Series Bolted Motor Starters and Contactors Explosionproof, Dust-Ignitionproof, Watertight Full Voltage. Combination and Non-Combination.

Open Type Without Enclosure

AC Magnetic Starters (GE)

Transformer Questions & Answers

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Transformer Questions & Answers

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

HPS Universal BUCK-BOOST TRANSFORMERS

Switches Unlimited Contact: Phone: Fax:

Heavy Duty Motor Starters

150 C 30 F B D 8L 152H C 30 F BD 43 8L

ECL03B1AAA 20A 120V Lighting Contactor

BUCK-BOOST TRANSFORMERS

NEMA Contactor and Starter Specifications

Steps for Selecting the Proper Transformer

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001

Deploying Current Transformers in Applications Greater Than 200 A

Switches & Pilot Devices

Inverter MICROMASTER 410

For Immediate Delivery call KMParts.com at (866)

Solid-State Switching Devices

Application Description

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Full Line Product Catalog

Motor Protection Circuit Breaker Series 8146/5-V27

AF91 Adjustable Frequency Drives Series B

Variable Transformers Product Design & Engineering Data

C-Series. Circuit Breaker.

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

CI-tronic Soft start motor controller

NEMA Size 1 Cat. No. CN55DN3AB

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG

Heavy Duty Safety Switches

Overview: Extensions. Stepper Motors

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

Figure 1 Typical Inverter Block Diagram

Type KLF Generator Field Protection-Loss of Field Relay

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English

Ampgard The name motor applications rely on

SIRIUS/SIKOSTART Soft Starters For Standard Applications

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED

Comparison between Direct-On-Line, Star-Delta and Auto-transformer Induction Motor Starting Method in terms of Power Quality

General data 4/5. Overview. You can find further information on the Internet at:

ECET 211 Electrical Machines and Controls

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

hp

Crane Control Class 7001

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

MODEL 421 Over/Under Motor Load Monitor

Instruction Bulletin Reduced Voltage Starters Autotransformer Type Class 8606

Document # Logos: Purch-11B Purchasing Use ONLY: How to Change a Vendor in Logos Original Author Karrie Revolinski Date 5/10/13 Updated Author Date

AC Drives and Soft Starter Application Guide

Sizing an SR55 Soft Starter

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Accessories for A/AF/AL & AE contactors

Price groups PG 41B, 41C, 41E, 41F, 41H, 41J, 42G, 42H, 42J, 401

Small but rugged DRAFT

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Transformer Protection Principles

Primary Resistor Starters with Time Relays

G-Series Servomotors. AC Brushless Servomotors. Understanding the G-Series Servomotor Model Numbers

SIRIUS 3RW Soft Starters 4/5 General data 3RW30, 3RW40 for Standard Applications 4/8 3RW30 4/18 3RW40 3RW44 for High-Feature Applications 4/34 3RW44

ECE 528 Understanding Power Quality. Paul Ortmann (voice) Lecture 6

PowerGard Series C 18-Pulse Enclosed Drive Controllers

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Bulletin 1497 Global Control Transformers

XT IEC Power Control Miniature Controls

PART 1 OWNER/APPLICANT INFORMATION

Full Line Product Catalog

Accessories Field Installable

Single, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

TABLE OF CONTENT

PowerFlex 400 Submittal

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

SECTION A MOTORS AND ELECTRICAL COMPONENTS

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

SINPAC Switches: Brief Operating Description. Mounting Options

Acme Electric Full Line Product Catalog

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

2.1. Product Description

ECET 211 Electric Machines & Controls Lecture 3-2 (Part 2 of 2) Motor Transformers and Distribution Systems

Short-Circuit Current Calculations

Transcription:

Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current of a motor is likely to exceed local power company restrictions, interfere with plant operations or where the load may be damaged by high starting torques. Starting with the best All Sprecher + Schuh reduced voltage starters feature our AT7 and AT9 line of motor starters. These compact starters offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. Our advanced EP7 solid state overload relays are used with starters. See Section B in this catalog for a full description of these excellent motor protection relays. hoosing the right reduced voltage method Autotransformer Starter At starting, three autotransformers (one for each phase) are automatically connected in series with the motor. The voltage at the motor is reduced to either 50%, 65% or 80% depending on which voltage tap was selected. After a timed interval, a contactor connects the motor across-the-line and shorts out the autotransformers. Factory standard autotransformers are rated for medium duty as defined by NEA. Part Winding Starter This type of starting requires that the motor winding be in two equal parts, and that at least six terminal leads be provided on the motor. At starting, the controller is arranged to connect one section of the winding to the supply lines. After a timed interval, a second contactor connects the other section of the motor winding to the supply lines, in parallel with the first. Wye-elta Starter This type of starting requires a special wye-delta motor. Both ends of the motor s three windings are brought out so they are accessible for reconnecting from wye to delta. At starting, the controller connects the motor in the wye configuration. After a timed interval, a second contactor connects the motor in a delta configuration. The reference chart below compares all three reduced voltage starting methods and contrasts them with across-theline starting. Reduced Voltage omparison Table Type of Starter Starting haracteristics Line urrent Voltage @ otor Starting Torque Across-The-Line 100% 100% 100% Autotransformer 80% 65% 50% 64% 42% 25% 64% 42% 25% Part Winding 100% 65% 42% Advantages l Least expensive. l Simple to maintain. l Highest starting torque. l Readily available. l Lowest installation cost. l Provides highest torque per ampere of line current. l Three different taps on transformer permit adjustment of starting voltage. l Suitable for long starting periods. l losed transition starting. l Uses standard motor.. l Least expensive of all reduced voltage starters. l losed transition starting. l Small physical size. l ost dual voltage motors can be used. l Simple design. l Low installation cost. isadvantages l High starting inrush may exceed limits of local utility or electrical system. l Starting torque may be too high for the application. l Limited to smaller horsepower motors. l n lower horsepower, is the most expensive design. l Low power factor. l Large physical size. l High installation cost. l Poor torque efficiency l Unsuited for high inertia, long starting loads. l otor may not accelerate during start period. l Requires special motor design for voltages higher than 230 volts. Wye-elta 100% 33% 33% l Suitable for high inertia, long acceleration loads. l High torque efficiency. l deal for especially stringent inrush restrictions. l deal for frequent starts. l Requires special motor design. l Low starting torque. l Open transition (closed available). l omplex design. 87

Autotransformer - Series AAT Autotransformer 10 HP to 125 HP (losed Transition - Type 1 General Purpose Enclosure) ➍ aximum H.P. 10 15 20 25 30 40 50 60 75 100 125 3 Ø Volts out Short ircuit Protection B Thermal agnetic ircuit Breaker (B) Fuse lip Fusible isconnect ➋➎ atalog No. Price ➊ atalog No. Price ➊ ➌ atalog No. Price ➊ AAT AAT AAT 200 BA7-37- - -G0 7308 F 50 BA7-37- - -TB50G0 9397 S 60 BA7-37- - -JF62G0 8645 S 230 BB7-37- - -G0 7308 F 50 BB7-37- - -TB50G0 9397 S 60 BB7-37- - -JF62G0 8645 S 200 A7-60- - -G0 9102 F 100 A7-60- - -TB100G0 11187 S 100 A7-60- - -JF63G0 9332 S 230 B7-43- - -G0 7616 F 80 B7-43- - -TB80G0 9705 S 100 B7-43- - -JF63G0 8988 S 200 A7-72- - -G0 9358 F 125 A7-72- - -TB125G0 11444 S 100 A7-72- - -JF63G0 9589 S 230 B7-60- - -G0 9102 F 100 B7-60- - -TB100G0 11187 S 100 B7-60- - -JF63G0 9332 S 200 EA7-85- - -G0 9688 F 125 EA7-85- - -TB125G0 11775 S 200 EA7-85- - -JF64G0 9919 S 230 EB7-72- - -G0 9358 F 125 EB7-72- - -TB125G0 11444 S 100 EB7-72- - -JF63G0 9589 S 460 E7-37- - -G0 7308 F 50 E7-37- - -TB50G0 9397 S 60 E7-37- - -JF62G0 8645 S 200 FA7-97- - -G0 10417 F 175 FA7-97- - -TB175G0 ➏ 12564 S 200 FA7-97- - -JF64G0 13033 230 FB7-85- - -G0 9688 F 125 FB7-85- - -TB125G0 11775 S 200 FB7-85- - -JF64G0 9919 S 460 F7-43- - -G0 7616 F 70 F7-43- - -TB70G0 9705 S 60 F7-43- - -JF62G0 8988 S 575 F7-37- - -G0 7308 F 50 F7-37- - -TBH50G0 9542 S 60 F7-37- - -JF62G0 8645 S 200 GA9-146- - -G0 ➐ 15489 H 225 GA9-146- - -TB225G0 ➐ 20584 J 200 GA9-146- - -JF64G0 ➐ 23949 J 230 GB9-116- - -G0 ➐ 13353 H 200 GB9-116- - -TB200G0 ➐ 17745 J 200 GB9-116- - -JF64G0 ➐ 20646 J 460 G7-60- - -G0 9102 F 100 G7-60- - -TB100G0 11187 S 100 G7-60- - -JF63G0 9332 S 575 G7-60- - -G0 9102 F 80 G7-60- - -TBH80G0 11332 S 60 G7-60- - -JF62G0 9332 S 200 HA9-190- - -G0 ➐ 20718 300 HA9-190- - -TB300G0 ➐ 25798 J 400 HA9-190- - -JF65G0 ➐ 26449 K3 230 HB9-146- - -G0 ➐ 15489 250 HB9-146- - -TB250G0 ➐ 20584 J 200 HB9-146- - -JF64G0 ➐ 23949 J 460 H7-72- - -G0 9358 F 125 H7-72- - -TB125G0 11444 S 100 H7-72- - -JF63G0 9589 S 575 H7-60- - -G0 9102 F 100 H7-60- - -TBH100G0 11332 S 100 H7-60- - -JF63G0 9332 S 200 JA9-205- - -G0 ➐ 33096 J 350 JA9-205- - -TB350G0 ➐ 43228 J 400 JA9-205- - -JF65G0 ➐ 40099 K3 230 JB9-190- - -G0 ➐ 20718 300 JB9-190- - -TB300G0 ➐ 25798 J 400 JB9-190- - -JF65G0 ➐ 26449 K3 460 J7-85- - -G0 9688 F 125 J7-85- - -TB125G0 11775 S 200 J7-85- - -JF64G0 9199 S 575 J7-72- - -G0 9358 F 125 J7-72- - -TBH125G0 11589 S 100 J7-72- - -JF63G0 9589 S 200 KA9-265- - -G0 ➐ 33507 J 400 KA9-265- - -TB400G0 ➐ 43118 K2 400 KA9-265- - -JF65G0 ➐ 39443 K2 230 KB9-205- - -G0 ➐ 33096 J 350 KB9-205- - -TB350G0 ➐ 43228 K2 400 KB9-205- - -JF65G0 ➐ 40099 K2 460 K7-97- - -G0 10417 F 175 K7-97- - -TB175G0 ➏ 12564 S 200 K7-97- - -JF64G0 13033 575 K7-97- - -G0 10417 F 150 K7-97- - -TBH150G0 ➏ 12564 S 200 K7-97- - -JF64G0 13033 200 LA9-305- - -G0 ➐ 36984 J2 500 LA9-305- - -TB500G0 ➐ 47561 K2 600 LA9-305- - -JF66G0 ➐ 51773 K2 230 LB9-265- - -G0 ➐ 33507 J 450 LB9-265- - -TB450G0 ➐ 43688 K2 400 LB9-265- - -JF65G0 ➐ 39443 K2 460 L9-146- - -G0 ➐ 15489 225 L9-146- - -TBH225G0 ➐ 20062 J 200 L9-146- - -JF64G0 ➐ 23949 J 575 L9-116- - -G0 ➐ 13353 H 200 L9-116- - -TBH200G0 ➐ 17295 J 200 L9-116- - -JF64G0 ➐ 20646 J 200 A9-370- - -G0 ➐ 42532 J2 700 A9-370- - -TB700G0 ➐ 54695 K2 600 A9-370- - -JF66G0 ➐ 59539 K2 230 B9-305- - -G0 ➐ 36984 J2 600 B9-305- - -TB600G0 ➐ 47561 K2 600 B9-305- - -JF66G0 ➐ 51773 K2 460 9-190- - -G0 ➐ 20718 300 9-190- - -TB300G0 ➐ 25798 J 400 9-190- - -JF65G0 ➐ 26449 K3 575 9-146- - -G0 ➐ 15489 225 9-146- - -TBH225G0 ➐ 20062 J 200 9-146- - -JF64G0 ➐ 23949 J Larger Horsepower ontinued On Next Page NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available See page 104 See pages 105-106 See pages 107-111 ➊ imensional information starts on page 122. ➋ For Non-fusible isconnect applications, replace the "JF" characters with "JU". Example: AATH7-72- - -JF63G0 becomes AATH7-72- - -JU63G0. ➌ Fuse clips sized for use with J -type fuses. ➍ Other enclosures available. ontact your Sprecher + Schuh Representative. ➎ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➏ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➐ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATGB9-116- - -G0 becomes AATGB9-116-E- - -G0. See page 104 for price adder. 88 iscount Schedule B7

Autotransformer - Series AAT Autotransformer 150 HP to 1000 HP (losed Transition - Type 1 General Purpose Enclosure) ➍ aximum H.P. 3 Ø Volts out Short ircuit Protection B Thermal agnetic ircuit Breaker (B) atalog No. Price ➊ atalog No. Price ➊ ➌ atalog No. Price ➊ AAT AAT AAT 200 NA9-460-E- - -G0 45681 J2 800 NA9-460-E- - -TB800G0 60873 R/F 800 NA9-460-E- - -JF67G0 61264 ~ 150 230 NB9-370- - -G0 ➏ 42532 J2 700 NB9-370- - -TB700G0 ➏ 54695 K2 600 NB9-370- - -JF66G0 ➏ 59539 K2 460 N9-205- - -G0 ➏ 33096 350 N9-205- - -TB350G0 ➏ 43228 J 400 N9-205- - -JF65G0 ➏ 40099 K3 575 N9-190- - -G0 ➏ 20718 300 N9-190- - -TB300G0 ➏ 25798 J 400 N9-190- - -JF65G0 ➏ 26449 K3 230 OB9-460-E- - -G0 45681 ~ 1000 OB9-460-E- - -TB1000G0 60873 ~ 800 OB9-460-E- - -JF67G0 61264 ~ 200 460 O9-265- - -G0 ➏ 33507 J 450 O9-265- - -TB450G0 ➏ 43688 K2 400 O9-265- - -JF65G0 ➏ 39443 K2 575 O9-205- - -G0 ➏ 33096 J 350 O9-205- - -TB450G0 ➏ 43228 K2 400 O9-205- - -JF65G0 ➏ 40099 K3 230 PB9-580-E- - -G0 R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ 250 460 P9-305- - -G0 ➏ 36984 J2 600 P9-305- - -TB600G0 ➏ 47561 K2 600 P9-305- - -JF66G0 ➏ 51773 K2 575 P9-265- - -G0 ➏ 33507 J 450 P9-265- - -TB450G0 ➏ 43688 K2 400 P9-265- - -JF65G0 ➏ 39443 K2 230 QB9-750-E- - -G0 R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ 300 460 Q9-370- - -G0 ➏ 42532 J2 700 Q9-370- - -TB700G0 ➏ 54695 K2 600 Q9-370- - -JF66G0 ➏ 59539 K2 575 Q9-305- - -G0 ➏ 36984 J2 600 Q9-305- - -TB600G0 ➏ 47561 K2 600 Q9-305- - -JF66G0 ➏ 51773 K2 230 Refer to Factory R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ 350 460 R9-400-E- - -G0 37753 J2 800 R9-400-E- - -TB800G0 50308 RF 800 R9-400-E- - -JF67G0 50631 ~ 575 R9-370- - -G0 ➏ 42532 J2 600 R9-370- - -TB600G0 ➏ 54695 K2 600 R9-370- - -JF66G0 ➏ 59539 K2 230 Refer to Factory R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ 400 460 S9-460-E- - -G0 45681 ~ 1000 S9-460-E- - -TB1000G0 60873 ~ 800 S9-460-E- - -JF67G0 61264 ~ 575 S9-400-E- - -G0 37753 J2 700 S9-400-E- - -TB700G0 50308 K2 600 S9-400-E- - -JF66G0 50631 ~ 230 Refer to Factory R/F ~ Refer to Factory R/F ~ 450 460 T9-580-E- - -G0 59386 ~ Refer to Factory R/F ~ 575 T9-460-E- - -G0 45681 ~ 800 T9-460-E- - -TB800G0 60873 ~ 500 460 U9-580-E- - -G0 59386 ~ Refer to Factory R/F ~ Refer to Factory 575 U9-460-E- - -G0 45681 ~ 900 Refer to Factory R/F ~ 600 460 U9-750-E- - -G0 77796 ~ 575 U9-580-E- - -G0 59386 ~ Refer to Factory R/F ~ Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Fuse lip Fusible isconnect ➋➎ Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available See page 104 See pages 105-106 See pages 107-111 ➊ imensional information starts on page 122. ➋ For Non-fusible isconnect applications, replace the "JF" characters with "JU". Example: AATN9-205-E- - -JF65G0 becomes AATN9-205-E- - -JU65G0. ➌ Fuse clips sized for use with J -type fuses up to 600A. Power fuses not supplied. ➍ Other enclosures available. ontact your Sprecher + Schuh Representative. ➎ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➏ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATN9-190- - -G0 becomes AATN9-190-E- - -G0. See page 104 for price adder. iscount Schedule B7 89

Part Winding - Series APWT Part Winding (Two Step) aximum Horsepower Three Phase Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resist Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ APWT APWT APWT APWT 10 15 30 30 7-30- - -G0 1536 7-30- - -O 1617 7-30- - -WO 1981 7-30- - -O 1981 U1 15 ~ 40 40 7-37- - -G0 1779 7-37- - -O 1859 7-37- - -WO 2547 7-37- - -O 2547 U1 20 20 50 50 7-43- - -G0 2061 7-43- - -O 2143 7-43- - -WO 2911 7-43- - -O 2911 U1 25 25 60 60 7-55- - -G0 2133 7-55- - -O 2214 7-55- - -WO 2982 7-55- - -O 2982 U1 25 30 60 75 7-60- - -G0 2344 7-60- - -O 2425 O 7-60- - -WO 3266 O 7-60- - -O 3266 V1 30 40 75 100 7-72- - -G0 2506 7-72- - -O 2587 O 7-72- - -WO 3476 O 7-72- - -O 3476 V1 40 50 100 125 7-85- - -G0 3234 7-85- - -O 3314 O 7-85- - -WO 4196 O 7-85- - -O 4196 V1 50 50 100 150 7-97- - -G0 3408 7-97- - -O 3489 O 7-97- - -WO 4371 O 7-97- - -O 4371 V1 60 60 100 150 9-116- - -G0 ➍ 5427 E2 9-116- - -0 ➍ 7097 R2 9-116- - -W0 ➍ 8333 R2 9-116- - -0 ➍ 8333 W2 60 75 150 200 9-146- - -G0 ➍ 6295 G 9-146- - -0 ➍ 8233 T 9-146- - -W0 ➍ 9666 T 9-146- - -0 ➍ 9666 A2 75 75 200 200 9-190- - -G0 ➍ 8175 H 9-190- - -0 ➍ 8918 H 9-190- - -W0 ➍ 11882 H 9-190- - -0 ➍ 11882 Y1 75 100 200 300 9-205- - -G0 ➍ 13607 H 9-205- - -0 ➍ 14417 H 9-205- - -W0 ➍ 17009 H 9-205- - -0 ➍ 17009 Y1 100 150 300 350 9-265- - -G0 ➍ 14596 J 9-265- - -0 ➍ 15364 J 9-265- - -W0 ➍ 17284 J 9-265- - -0 ➍ 17284 Z1 150 200 350 450 9-305- - -G0 ➍ 17861 J 9-305- - -0 ➍ 18693 J 9-305- - -W0 ➍ 18948 J 9-305- - -0 ➍ 18948 Z1 Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ombination Part Winding Starter Options hart ➌ ircuit Breaker or isconnect Switch Thermal agnetic ircuit Breaker Non Fusible isconnect Fusible isconnect - 30 Amp Fusible isconnect - 60 Amp Fusible isconnect - 100 Amp Fusible isconnect - 200 Amp Fusible isconnect - 400 Amp Fusible isconnect - 600 Amp Price (Add to base Part Winding starter list price) 7-60 Enclosure 7-37 7-72 9-190(-E) 7-43 7-85 9-116 (-E) 9-205(-E) Type 7-30 7-55 7-97 9-146 (-E) 9-265(-E) Type 1 1152 1253 2291 4456 6559 Type 12/3R/4/4X 1206 1347 3095 5099 7062 Type 1 804 1018 1407 2519 5782 Type 12/3R/4/4X 858 1112 2265 2787 6285 Type 1 911 ~ ~ ~ ~ Type 12/3R/4/4X 998 ~ ~ ~ ~ Type 1 1052 1099 ~ ~ ~ Type 12/3R/4/4X ~ 1193 ~ ~ ~ Type 1 ~ 1400 1702 ~ ~ Type 12/3R/4/4X ~ 1849 2506 ~ ~ Type 1 ~ ~ 2425 2760 ~ Type 12/3R/4/4X ~ ~ 2613 3028 ~ Type 1 ~ ~ ~ 3705 6492 Type 12/3R/4/4X ~ ~ ~ 3973 6995 Type 1 ~ ~ ~ ~ 7256 Type 12/3R/4/4X ~ ~ ~ ~ 8261 9-305(-E) ontact factory for pricing. Ordering nstructions Specify atalog Number Replace (Q) with oil ode ultiply otor FLA by 50%, Factory odifications available See page 104 See pages 105-106 See pages 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". Price remains the same, dimensions may change. Example: APWT7-30- - -0 becomes APWT7-30- - -R0. ➌ Refer to pages 4-5 for information on modifying standard Part Winding catalog number to combination type or contact Sprecher + Schuh Technical Support. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATN9-190- - -G0 becomes AATN9-190-E- - -G0. See page 104 for price adder. 90 iscount Schedule B7

Wye elta - Series AYT Wye elta (Open Transition, 3-ontactor ➍) aximum Horsepower Three Phase Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AYT AYT AYT AYT 10 15 30 30 7-30- - -G0 1445 7-30- - -O 1496 O 7-30- - -WO 1940 O 7-30- - -O 1940 V1 15 20 40 40 7-37- - -G0 2143 7-37- - -O 2182 O 7-37- - -WO 2628 O 7-37- - -O 2587 V1 20 25 50 50 7-43- - -G0 2344 7-43- - -O 2385 O 7-43- - -WO 2829 O 7-43- - -O 2829 V1 25 30 60 60 7-55- - -G0 2452 7-55- - -O 2492 O 7-55- - -WO 2937 O 7-55- - -O 2937 V1 30 40 75 75 7-60- - -G0 2741 7-60- - -O 3702 Q 7-60- - -WO 3517 Q 7-60- - -O 3702 W1 40 50 100 100 7-72- - -G0 3234 F 7-72- - -O 3951 T 7-72- - -WO 4446 T 7-72- - -O 5659 X1 50 60 125 125 7-85- - -G0 3557 F 7-85- - -O 4285 T 7-85- - -WO 4851 T 7-85- - -O 5983 X1 60 60 150 150 9-116- - -G0 4592 G 9-116- - -0 5177 T 9-116- - -W0 6346 T 9-116- - -0 9443 A2 75 75 150 200 9-146- - -G0 5327 G 9-146- - -0 6005 T 9-146- - -W0 7361 T 9-146- - -0 10954 A2 75 100 200 250 9-190- - -G0 8175 H 9-190- - -0 8621 H 9-190- - -W0 10107 H 9-190- - -0 12002 Y1 100 125 250 300 9-205- - -G0 13202 9-205- - -0 13364 9-205- - -W0 14239 J 9-205- - -0 16377 Z1 150 150 350 450 9-265- - -G0 14211 J 9-265- - -0 14365 J 9-265- - -W0 14596 J 9-265- - -0 16270 Z1 150 200 450 500 9-305- - -G0 15453 J 9-305- - -0 15608 J 9-305- - -W0 16978 J 9-305- - -0 17472 Z1 200 250 500 600 9-370- - -G0 17771 J 9-370- - -0 17949 J 9-370- - -W0 19525 J 9-370- - -0 20093 Z1 250 250 600 700 9-400-E- - -G0 18261 ~ 9-400-E- - -0 18397 ~ 9-400-E- - -W0 21737 ~ 9-400-E- - -0 20196 ~ 300 350 700 800 9-460-E- - -G0 22096 ~ 9-460-E- - -0 22260 ~ 9-460-E- - -W0 26302 ~ 9-460-E- - -0 24437 ~ 350 450 800 1000 9-580-E- - -G0 28725 ~ 9-580-E- - -0 28938 ~ 9-580-E- - -W0 34193 ~ 9-580-E- - -0 31768 ~ 450 500 1000 1250 9-750-E- - -G0 37630 ~ 9-750-E- - -0 37909 ~ 9-750-E- - -W0 44792 ~ 9-750-E- - -0 41616 ~ 600 700 1250 1750 9-860-E- - -G0 50801 ~ 9-860-E- - -0 51177 ~ 9-860-E- - -W0 60470 ~ 9-860-E- - -0 56182 ~ 600 700 1500 1750 9-1060-E- - -G0 56897 ~ 9-1060-E- - -0 57318 ~ 9-1060-E- - -W0 67726 ~ 9-1060-E- - -0 62923 ~ Larger sizes available. ontact your Sprecher + Schuh representative. ombination Wye elta Starter Options hart ➌ ircuit Breaker or isconnect Switch Thermal agnetic ircuit Breaker Non Fusible isconnect Fusible isconnect - 30 Amp Fusible isconnect - 60 Amp Fusible isconnect - 100 Amp Fusible isconnect - 200 Amp Fusible isconnect - 400 Amp Fusible isconnect - 600 Amp Price (Add to base Part Winding starter list price) 9-305(-E) 7-37 7-60 9-190(-E) 9-370(-E) Enclosure 7-43 7-72 9-116 (-E) 9-205(-E) 9-400-E Type 7-30 7-55 7-85 9-146 (-E) 9-265(-E) 9-460-E Type 1 1152 1253 2291 4456 6559 9092 Type 12/3R/4/4X 1206 1347 3095 5099 7062 9594 Type 1 804 1018 1407 2519 5782 6117 Type 12/3R/4/4X 858 1112 2265 2787 6285 6620 Type 1 858 ~ ~ ~ ~ ~ Type 12/3R/4/4X 911 ~ ~ ~ ~ ~ Type 1 1099 1099 ~ ~ ~ ~ Type 12/3R/4/4X 1193 1193 ~ ~ ~ ~ Type 1 ~ 1702 1702 ~ ~ ~ Type 12/3R/4/4X ~ 2506 2506 ~ ~ ~ Type 1 ~ ~ 2760 2760 ~ ~ Type 12/3R/4/4X ~ ~ 3028 3028 ~ ~ Type 1 ~ ~ ~ 6492 6492 ~ Type 12/3R/4/4X ~ ~ ~ 6995 6995 ~ Type 1 ~ ~ ~ ~ 6827 6827 Type 12/3R/4/4X ~ ~ ~ ~ 7162 7162 9-580-E 9-750-E 9-860-E 9-1060-E ontact factory for pricing. Ordering nstructions Specify atalog Number Replace (Q) with oil ode ultiply otor FLA by 58%, Factory odifications available See page 104 See pages 105-106 See pages 107-111 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AYT7-30- - -0 becomes AYT7-30- - -R0. Price remains the same. ➌ Refer to pages 4-5 for information on modifying standard Wye elta catalog number to combination type or contact Sprecher + Schuh Technical Support. ➍ For closed transition Wye elta applications, please contact factory. iscount Schedule B7 91