Linear measurement with a magnetic pole stripe (I 2 C-Mode)

Similar documents
MiniSense 100 Analog PCB

P-Series Inclinometer

KMA36 universal magnetic encoder

80 khz Cylindrical Ultrasound Transducer

TSYS01 Digital Temperature Sensor

NDT1-220K Ultrasonic Transducer

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

AccuStar Electronic Clinometer

Accelerometer ACH-01. Piezoelectric Accelerometer Wide Bandwidth; AC Coupled Ultra Low Power High G Ranges

TSYS02S Digital Temperature Sensor

ED-17 Serial Output Magnetic Encoder

OPERATION MANUAL LDM-1000

A Simple Pressure Sensor Signal Conditioning Circuit

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Signal Conditioning for MEAS Pressure Sensors

Altitude and Airspeed Measurements Temperature Range. Range psid psig psia 0 to 1 0 to 5 0 to 15 0 to 30 0 to 50 0 to to to 300

Instruction Manual Single and Dual Axis Inclinometer V-Series

TSYS02P Digital Temperature Sensor

KMA36 universal magnetic encoder

FC22 Compression Load Cell

P125 High pressure sensor

V-SERIES INCLINOMETER

XP5 Miniature pressure sensor

ELPF Load Cell DESCRIPTION

E2-Series Inclinometer

TSYS02P Digital Temperature Sensor

Instruction Manual Single and Dual Axis Inclinometer P-Series

Instruction Manual DPG-Series Inclinometer

U5700 Submersible Liquid Level Pressure Transducer

PSI Temperature Scanners

FC22 Compression Load Cell

TSYS02D Digital Temperature Sensor

HS1101LF Relative Humidity Sensor

Specification DPG-Series Inclinometer

Operation Manual. LVDT/RVDT Signal Conditioner

KMA36-SPI Rotational and Linear Position Sensor IC

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

HM1500LF Relative Humidity Module

Model 140 Inline Amplifier

Instruction Manual D-Series Inclinometer

BIPOLAR HALL-EFFECT POSITION SENSORS

PSBDAF20~200V1 Schottky Barrier diode

PSBDBFXXXV5 Schottky Barrier diode

HTG3500 Series Relative Humidity and Temperature Module

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

KMT37 Magnetic Angle Sensor

Parameter Symbol Min Typ Max Unit Note Strip Length L 300±2 mm Active length = 300mm Strip Width W 10±0.2 mm Active width = 10mm 1,3±0, 15

EVERSPIN s New 2mm Exposed Pad DFN Package Meets Both SOIC-8 and DFN8 PCB Layouts

ic-sm2l LINEAR AMR SENSOR (2 mm)

P-Series Inclinometer

ARCHIVE INFORMATION. Cellular Band RF Linear LDMOS Amplifier MHL9318. Freescale Semiconductor. Technical Data MHL9318. Rev.

ARCHIVE INFORMATION. Cellular Band RF Linear LDMOS Amplifier MHL9838. Freescale Semiconductor. Technical Data MHL9838. Rev.

M5200 Industrial Pressure Transducer

ic-sm5l LINEAR AMR SENSOR (5 mm)

4 Maintaining Accuracy of External Diode Connections

IR Sensor Module for Remote Control Systems

TP2 SWP 4.7 H. Designator LXP VOUTP NCP ENABLE J2 TP5 SWN FBN SWN D1 L2. R4 18k TP8 FBN. Figure 1. NCP5810DGEVB Schematic

EBR7912EBI-CA-KA Incremental Sensor Module with Reference

FlexTimer and ADC Synchronization

Features. Packages. Applications

SCALE BASED MAGNETORESISTIVE SENSOR SYSTEMS

Pin Configuration T Package (TO-220-) S/SA Package (TO-26-) S SA 2 1 GND 2 1 GND 2 1 GND DA Package (TO-252-2(1)) (TO-252-2(2)) 2 GND 2 GND 1 1 (TO-25

FPF1005-FPF1006 IntelliMAX TM Advanced Load Management Products

KMT36H 360 Magnetic Angle Sensor

IR Sensor Module for Remote Control Systems

XPC10 High temperature miniature pressure sensor

ARCHIVE INFORMATION. PCS Band RF Linear LDMOS Amplifier MHL Freescale Semiconductor. Technical Data MHL Rev. 4, 1/2005

PESDHC5D7VU ESD Protector

5A LOW DROPOUT LINEAR REGULATOR. Features. Applications

ARCHIVE INFORMATION. Cellular Band RF Linear LDMOS Amplifier MHL9236MN. Freescale Semiconductor. Technical Data

MMIC VCO MMVC92. MMIC VCO GHz Type Q. General Description. Features. Packages. Functional Diagram. Applications

5KP Series 5000 Watt Axial Leaded Transient Voltage Suppressor

CAT5126. One time Digital 32 tap Potentiometer (POT)

P4KE6.8A thru P4KE540A. TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor. FEATURES PRIMARY CHARACTERISTICS

Single Phase Rectifier Bridge, 1.9 A

NXH80T120L2Q0S2G/S2TG, NXH80T120L2Q0P2G. Q0PACK Module

KMA36 Contactless Rotational and Linear Encoder

PESDLC23T5VU Low Capacitance ESD Protector

ICTE5 thru ICTE18C, 1N6373 thru 1N6386. TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor.

Single Phase Bridge Rectifier, 2 A

Heterojunction Bipolar Transistor (InGaP HBT) Broadband High Linearity Amplifier

SINGLE PHASE HALL EFFECT LATCH General Description. Features. Applications

PESDSC2FD5VB ESD Protector

PIEZO FILM LAB AMPLIFIER

PCS2I2309NZ. 3.3 V 1:9 Clock Buffer

Versatile Planar Transformer

EVALUATION BOARD FOR STK N, 120N, 140N. Phenol 1-layer Board) Figure 2. STK NGEVB Figure 3. STK NGEVB Figure 4.

AL794 MagnetoResistive FixPitch Sensor (2.5 mm)

Rotational Absolute Magnetic Kit Encoder Version 33 LP and HP Displacement Sensor

PESDAWC236T5VU Low Capacitance TVS Array

CONSTANT VOLTAGE AND CONSTANT CURRENT CONTROLLER General Description. Features. Applications

1 Block HV2 LDMOS Device Number of fingers: 56, Periphery: 5.04 mm Frequency: 1 GHz, V DS. =26 v & I DS

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

Heterostructure Field Effect Transistor (GaAs HFET) Broadband High Linearity Amplifier

PCS2P2309/D. 3.3V 1:9 Clock Buffer. Functional Description. Features. Block Diagram

LA1654C. Function RF amplifier, rectifier, detector, time code output, and standby circuit.

HTM25X0LF Temperature and Relative Humidity Module

Is Now Part of To learn more about ON Semiconductor, please visit our website at

AN4269. Diagnostic and protection features in extreme switch family. Document information

Transcription:

Linear measurement with a magnetic pole stripe (I 2 C-Mode) KMA36 / Demo board Version: 1.0 July 2012 Please use also KMA36 white paper and KMA36 data sheet Hauert 13, D-44227 Dortmund, Germany 1 of 7 fax: +49-(0)231-9740-20

Linear measurement with a magnetic pole stripe (I 2 C-Mode) Fig. 1: Setup for linear measurement with a magnetic pole stripe You can use the KMA36 demo board in combination with a magnetic stripe for linear measurement. This document describes the operation in I 2 C-Mode (Supplementary instructions can be found in the documents KMA36 white paper and KMA36 data sheet ). KMA36 technical key data Max. resolution ±70 µm Max. absolute range of measurement Max. incremental range of measurement Digital resolution 10 mm 2^32 x 10mm = 42.949 km 13 Bit / 0.04 degree Operation power supply range 3.0 5.5V Operating temperature - 25 +85 C Average current Sleep current Data Update rate I2C Clockrate 10 30 ma 1.2 ma 24 720 Hz Up to 100 kbit/s Hauert 13, D-44227 Dortmund, Germany 2 of 7 fax: +49-(0)231-9740-20

Setup For restoring the standard configuration (s. white paper) please apply two solder connections on the back of the board (Fig. 2.) Fig. 2: Position of junctions For contacting the circuit board (PCBA) you can solder a double-row pin header (pitch 2.54 mm) (Fig 3). Please use the white paper for detailed information about the pin configuration. Fig. 3: Position of contact pins For performing a linear measurement, please remove a part of the PCB. Remove the superfluous part at the perforated site (s Fig. 3). Fig. 4: Preparation of the PCB Hauert 13, D-44227 Dortmund, Germany 3 of 7 fax: +49-(0)231-9740-20

Please position the demo board perpendicularly above the magnetic stripe, to reach a maximum accuracy (Fig. 4). The outer edge of the sensor chip has to be placed in the middle of the magnetic stripe. The optimal distance (air gap) between sensor and magnetic stripe is 0.1 mm The KMA36 sensor is optimized for magnetic stripes with a pole pair length of 5 mm. To achieve optimal results, please use comparable magnetic stripes. KMA36 magnetic stripe carrier (not magnetic) Fig. 4: Linear setup Please note that magnetic anomalies occur at the cutting edges of the magnetic stripe. To avoid inaccuracies the measurement should not start at the edge but with a distance to the edge of at least 5 mm (Fig 5) direction of movement Fig. 5: ideal measurement range Hauert 13, D-44227 Dortmund, Germany 4 of 7 fax: +49-(0)231-9740-20

Measurement Please configure the sensor via I²C at the beginning of the measurement (Supplementary instructions can be found in the datasheet and the white paper). To perform a linear measurement the linear mode has to be activated (set LIN-Bit in KCONF register). Furthermore we recommend to work with an oversampling of 32 (OVCS-Bits in KCONF register) and a resolution of 32768 (KRES register). If required, the incremental counter can also be activated (set CNT-Bit in KCONF register). With activated incremental counter the number of overrun pole pair can be read out (Supplementary information is given in the datasheet and the white paper). The previously described configuration leads to a measurement result as shown in Fig. 6. Fig. 6: measurement result Hauert 13, D-44227 Dortmund, Germany 5 of 7 fax: +49-(0)231-9740-20

With commercial magnetic stripes and optimal configuration an accuracy of ±70 µm can be reached. If the air gap is increased the measurement error will increase also. (Fig. 7) Fig. 7: accuracy vs. air gap Hauert 13, D-44227 Dortmund, Germany 6 of 7 fax: +49-(0)231-9740-20

CONTACT NORTH AMERICA EUROPE ASIA Measurement Specialties, Inc. 1000 Lucas Way Hampton, VA 23666 United States Phone: +1-800-745-8008 Fax: +1-757-766-4297 Email: sales@meas-spec.com Web: www.meas-spec.com MEAS Deutschland GmbH Hauert 13 D-44227 Dortmund Germany Phone: +49-(0)231-9740-0 Fax: +49-(0)231-9740-20 Email: info.de@meas-spec.com Web: www.meas-spec.com Measurement Specialties China Ltd. No. 26, Langshan Road High-tech Park (North) Nanshan District, Shenzhen 518057 China Phone: +86-755-33305088 Fax: +86-755-33305099 Email: info.cn@meas-spec.com Web: www.meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. Hauert 13, D-44227 Dortmund, Germany 7 of 7 fax: +49-(0)231-9740-20