MIX OFFICE BUILDING (N2-32) PREPARATION OF DESIGN AND EIA PROJECT BRIEF

Similar documents
Last Name: First Name: M.I:

2018 Conference Theme Imagine the Future"

Certificate by the Architect: Certified that no addition and deletion has been made to the tender documents downloaded from the IIT Madras web site.

Over-the-Rhine Historic District New Construction Guidelines Competition: The Challenge to elevate new build design in OTR to national recognition.

PITKIN COUNTY STANDARDS for ELECTRONIC DRAWINGS and DOCUMENTS SUBMISSION

Addendum to Description of Services for Building and Planning, Digital Design. The Association of of Consulting Engineers

FIT-OUT PERMIT REQUEST (GENERAL WORKS)

Architectural Review Board Application For Modifications & Renovations

Niguel Shores Community Association Architectural Committee (AC) EXTERIOR MODIFICATION SUBMITTAL (EMS) FINAL APPLICATION

APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT

Architectural Review Application

Single-Family Dwelling Submittal Requirements

Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:

5.7 Plan Documentation and Supporting Information.

IMPORTANT ADDITIONAL CONTRACTOR INFORMATION FROM THE OKLAHOMA TAX COMMISSION

Project 01: Infill Office Building Precast Concrete

Design Deliverables. Summary. A. Expectations for Design Deliverables:

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

Architectural Floor Plan Symbols

DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN

INDIGO LAKES HOA ARCHITECTURAL REVIEW COMMITTEE REQUEST FOR MODIFICATION

Cielito Lindo de Tubac Home Owners Association PAINTING POLICIES AND PROCEDURES

Landmarks Preservation Commission Tacoma Economic Development Department Culture and Tourism Division

The GMFI Process. Design Intent Document Preparation. Enroll in GMFI Program. Image Consultation. You are here. Design Intent Document.

Architectural Design Process

Company. Signed: Date:

Promontory Architectural Review Committee

Exhibit A Project Identification. Exhibit B Project Charter / Project Intent. Exhibit C Project Scope. Exhibit C Project Schedule

Dimension Below are the critical settings in AutoCAD. Other software should follow the same settings.

MULTIPLE-FAMILY DESIGN REVIEW SUBMITTAL CHECKLIST

Simonson Design Lab, Inc. Design Agreement

BIM/VDC on TAA Projects:

DOCUMENT LIST OF DRAWINGS, TABLES AND SCHEDULES

Developer Design Review Submittal Requirements - SECTION 5

Tri-County Commercial Application Checklist

Participants are limited to one (1) team, or one (1) individual, per chapter; one (1) entry per team or individual.

State College Area School District

CHAPTER 5 ARCHITECTURE

Tenant Design Criteria Section k Kiosk Design Criteria Updated: September 2013

2018 Design Competition Frequently Asked Questions. Q: Are teams allowed to register in more than one category of the competition?

Certificate of Appropriateness (CoA) Checklist

ARCHITECTURAL REVIEW COMMITTEE TOWN APARTMENT CONSTRUCTION SUBMITTAL FORM AND APPLICATION

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

NON-RESIDENTIAL DEVELOPMENT

Stanford University-Facilities Design Guideline SECTION Plans Review Submission Guidelines

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

SECTION PROJECT COORDINATION VIA BIM

Required Supporting Information and Documentation for Historic Preservation Certification Applications

Architectural Drafting

Entry Level Assessment Blueprint Architectural Drafting

HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA

Architect. Architect.

3 Basic Code Enforcement, Part 3

Listed below are the competencies required and examples from the aforementioned job:

SIGN PERMIT APPLICATION

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

CITY OF OLIVETTE SITE PLAN AND COMMUNITY DESIGN REVIEW INFORMATION PACKET

Environmental Design. Floor Plan. Planometric Drawing. Target Audience. Media. Materials

DESIGN REVIEW PROCESS AND APPLICATION

UPDATE TO ARCOM SUBMITTAL REQUIREMENTS - JULY 2018

New Denver, BC FEASIBILITY REPORT OCTOBER 2018 BOSUN HALL. p f

JAZZ DESIGNS. Looking for a designer that understands you and your market? B U I L D I N G D E S I G N E R S

EXECUTIVE SUMMARY of DESIGN REVIEW

Contents OVERVIEW INTRODUCTION TO CHIEF ARCHITECT GETTING READY TO DRAW QUICK START VACATION CABIN: FLOOR PLAN. How this Book is Put Together

SPARTAN DAY CAMP 4814 FREEDOM RING RD

Assignment 1.5 Pre-Design Base Building Model Investment Bank ARCH 5901 Instructor: Glenn Hill Fall 2013

National Association of Women in Construction Education Foundation CADIDESIGNIDRAFTING COMPETITION HIGH SCHOOL STUDENTS

ELECTRONIC DRAFTING GUIDELINES

Rezoning/OCP Amendment Application. Current OCP Designation. Proposed OCP Designation

PLAN SUBMITTAL REQUIREMENTS

Windmill Village Homeowners Association

This Call for Qualifications does not require the preparation of a design proposal.

CHICAGO LANDMARKS PERMIT APPLICATION AND PRE-PERMIT SUBMISSION REQUIREMENTS

GENERAL REQUIREMENTS (Print or Type) PROJECT DESCRIPTION OWNER CERTIFICATION

NEW SINGLE FAMILY HOMES

Scope of work of Architect (as per the agreement signed by the Architect)

Major Requirements Code Title Credits Description. 4 Interior Design Studio III

BRYANT HERITAGE PLAZA 5301 Magasin Avenue Beaumont, AB

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Attachment A HERON RIDGE ESTATES RESIDENTIAL NEIGHBORHOODS PROCEDURE FOR OBTAINING DESIGN COMMITTEE APPROVAL

HOENER ASSOCIATES INC. ARCHITECTS

Archicad Layout of Drawings

Electronic Plan Review. City of Mesquite, TX. eplan Review Standards Document

752 ST. MARYS RD. LAFAYETTE, CA. PROJECT DATA FLOOR AREA

Chuck Caesar. VIA: /Webposting April 27, 2017

ARCHITECTURAL REVIEW COMMITTEE HOMESITE CONSTRUCTION SUBMITTAL FORM AND APPLICATION

A GUIDE TO APPLYING FOR A BUILDING PERMIT FOR A DETACHED GARAGE OR ACCESSORY BUILDING

Building Standards Department. Markham eplan Submission Standards For Building Permits, Sign Permits and Zoning Preliminary Review

SANTA MONICA BOULEVARD BEVERLY HILLS OWNER: 9908 SANTA MONICA BLVD., LLC SAN VICENTE BLVD. SUITE 550

BDT119 Carpentry Basics

A-308 SITE 75A. Gensler 2020 K Street, Northwest Suite 200 Washington DC Telephone Facsimile

COVER SHEET A0.1 A0.1 COVER SHEET A1.1 FLOOR PLANS - FOUNDATION & MAIN LEVEL A1.2 FLOOR PLANS - UPPER LEVEL & ROOF A3.1 SECTIONS & INTERIOR ELEVATIONS

APPLICATION FOR SITE PLAN REVIEW

technologically advanced residential design software

Public Call to Artists for Expressions of Interest Newton Recreation Centre Glass Curtain Wall Design for glass frit application

COURSE OUTLINE. Course Number Course Title Credits. Co- or Pre-requisite BCT110 Construction Materials & Methods

North West Facilities Ltd Gaerwen Industrial Estate Gaerwen Isle of Anglesey LL60-6HR Tel: Fax: Mobile:

Telecommunication Application Form

British Club Renovation, Bangkok, Thailand Proposal for Full Scope Architectural & Engineering Services Submission Date:

Transcription:

MIX OFFICE BUILDING (N2-32) PREPARATION OF DESIGN AND EIA PROJECT BRIEF 1. INTRODUCTION The Mix Office building plot N2-32, is the first low carbon, energy efficient building to be developed in hulhumale located in the heart of Hulhumale phase 1, near the Central Park. The building is to become an iconic institutional development. 2. PROJECT DETAILS 2.1 Plot Area: 940 sqm (10,118 sqft) 2.2 Foot print: 737 sqm (7,933 sqft) 2.3 Gross Floor Area: 7,683 sqm (82,699) 2.4 Height: 37m (10 stories) 3. SCOPE OF WORK The project is designing as an energy efficient, contemporary office building with green sustainable strategies. The designer is expected to obtain the necessary consultancy from the relevant parties during the course of design stage to incorporate green sustainable strategies into the design. Following are the features that the Employer requires the Designer to explore within the course of the design, however the Designer will have the flexibility to decide and recommend the most relevant and cost effective features to this building; 3.1 Green strategies 3.1.1 Rainwater harvesting system 3.1.2 Solar/PV cells sufficient to power common areas 3.1.3 Vertical roof gardens at the different levels (with specially engineered Mix-Office Building Design and EIA Project Brief Planning & Development Department, Housing Development Corporation Ltd, Tel: 3353535, Fax: 3358892, Email:planning@hdc.com.mv 1

slabs) 3.1.4 Central AC system (OR) Water chill system 3.1.5 Energy efficient cladding (E.g. Low E, tinted glass) 3.1.6 Sun screen louvre system of exterior walls (Where required) 3.1.7 Natural light and ventilation The employer will propose a basic concept design. The designer shall not deviate his detail from this concept by the employer, however can propose methods in detail design to improve the project. (Please find attached concept drawings for further details). Employer will provide the support to give clarification to any queries which the designer would require at any stage. The designer is required to submit a work schedule indicating the important milestones of Design Stage considering the review period (Feedback period) within two days of signining the contract. Please find below the Required documents. With the submission of Required documents, the Employer would provide the necessary feedback. In giving feedbacks we would check whether if it fits the design guidelines, function, aesthetics, materials, façade etc. and a two way dialogue attain satisfactory level of work. The designer shall complete the Required documents in the order given 3.1 Required documents. The time of completion for the project shall be maximum 90 calendar days from which within the first 15 days designer has to submit documents 3.2.1 to 3.2.4 under 3.1 Required documents Please note that these documents should be designed and presented in a way which. Designer has to submit the documents 3.2.4 to 3.2.14 within the next 55 days. For the remaining 20 days the designer can submit the remaining document 3.2.15, 3.2.16. The project is only deemed to be completed when the Employer has issued the approval for all Required Documents. Designer should accommodate for the review period after submission and attend to any corrections or supplementary documents if required by the Employer. However please note that this will not change the time of completion of project. Mix-Office Building Design and EIA Project Brief Planning & Development Department, Housing Development Corporation Ltd, Tel: 3353535, Fax: 3358892, Email:planning@hdc.com.mv 2

3.2 Required Documents 3.2.1 Basic Architectural Drawings (Floor plans, Sections, Elevations, Exterior and interior material finishes) 3.2.2 2D rendered floor plans for each floor highlighting unit type and area 3.2.3 4 exterior 3D renders 3.2.4 4 interior 3D renders 3.2.5 Detailed Architectural Drawings & Structural drawings 3.2.6 Material schedule(in MS Word & PDF Format) 3.2.7 Design Specifications (In MS Word & PDF Format) 3.2.8 Services drawings 3.2.8.1 Plumbing drawings (referring to the latest MWSC guidelines) 3.2.8.2 Electical drawings (referring to the latest STELCO guidelines) 3.2.8.3 Fire (approved as per the latest MNDF fire guidelines) 3.2.9 Landscaping Details design 3.2.10 Environmental Impact Assessment Report 3.2.11 Structural calculations 3.2.12 protection method 3.2.13 inspection report 3.2.14 Bill of quantities both priced and unpriced (In MS Excel & PDF format) 3.2.15 Final exterior and interior render as per the final detail drawings 3.2.16 3D walkthrough animation/video Please note that the designer can start preparation of Environment impact assessment and (E.I.A) send for approval to the relevant authorities for approval once the documents 3.1.1 to 3.1.4 has been approved by the employer. For any further information, please refer to the attached guideline/concept drawings for further details Mix-Office Building Design and EIA Project Brief Planning & Development Department, Housing Development Corporation Ltd, Tel: 3353535, Fax: 3358892, Email:planning@hdc.com.mv 3

HDC Building Mini Mall Mix Office Building N2 Mosque PROJECT:N2-32 MIX OFFICE BUILDING DRAWING:LOCATION PLAN PLANNING AND DEVELOPMENT DEPARTMENT

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: SITE PLAN PLANNING AND DEVELOPMENT DEPARTME

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: GROUND FLOOR PLANNING AND DEVELOPMENT DEPARTMENT

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: FIRST FLOOR PLANNING AND DEVELOPMENT DEPARTME

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: SECOND FLOOR PLANNING AND DEVELOPMENT DEPARTME

OPTION 1 OPTION 2 PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: THIRD FLOOR PLANNING AND DEVELOPMENT DEPARTMENT

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: FOURTH TO NINTH FLOOR PLANNING AND DEVELOPMENT DEPARTMENT

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING: TENTH FLOOR PLAN PLANNING AND DEVELOPMENT DEPARTMENT

PROJECT:N2-32 MIX OFFICE BUILDING DRAWING:ROOF PLAN PLANNING AND DEVELOPMENT DEPARTME