PFM 5000 Measuring Instrument

Similar documents
HDU-SF (Horizontal Distribution Units - Single Flat)

SonoMeter 31 Energy Meters

Infocal 9 Energy calculator

SonoSelect 10 and SonoSafe 10 Energy Meters

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

DL/N 70. Datalogger CUSTOMER BENEFITS

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

POWER SYSTEM MODE STATUS

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Screw-in resistance thermometers with terminal head Form B

Product Features Benefits The IMC Group Ltd.

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ph or ORP Transmitter

MC2: Practicality for Calibration

GasSense NDIR INFRARED TRANSMITTER

Power supply. Calibration. Surface finishing. Seal. Process connection

Datalogger DL/N 70 Version:

CALYS 150. Advanced documenting multifunction calibrator thermometer

4-20mA, 0-10V and general process measuring bargraph displays

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

Goyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO)

On-site multifunction calibrator

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

ANALYTICAL - COMPLEXITY MADE SIMPLE

Conductivity Transmitter

GS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application

Windsond Product Catalogue

CALYS 150. Advanced documenting multifunction calibrator thermometer

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Datalogger DL.OCS/N/RS485

DTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor

CALYS channels High accuracy calibrator

Additel 875 Series Dry Well Calibrators

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Windsond Product Catalogue

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

CALYS 150. Advanced documenting multifunction calibrator thermometer

Wireless LAN network. Wireless USB network

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Additel 875 Series Dry Well Calibrators

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RELAY G10S PILOT S GUIDE B Yamaha Guitar Group, Inc. All rights reserved.

Wireless Temperature Sensor with Probe

CALYS 75. Field documenting multifunction calibrator

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

S45 Pump Electric Proportional Control

Wireless Temperature Sensor

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Resistance thermometers for process technology

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GeoMax GNSS Zenith10 & Zenith20 Series

Interface EKC 366 REFRIGERATION AND AIR CONDITIONING. Manual

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

CHANFLO 2500 / 3000 Open Channel Flowmeters

E instruments. MAXiCAL. ATEX Calibration Lab Multifunction Pressure and Temperature ATEX Calibrators

Digital conductivity transmitter

Wireless LAN network. Wireless USB network

Wireless systems.

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

BORE ALIGNMENT. Straightness measurement of bore and bearing journals PRINTER CONNECTION PC PROGRAM INCLUDED ELECTRONIC INCLINOMETER EXPANDABLE

FLOWIZ ( M L ) Warranty conditions are available on this website: only in English version

Instruction also available on

Product Features Benefits The IMC Group Ltd.

RAY MC COMPACT ENERGY METER MECHANICAL

MRP Rs.20,000 Free Home Delivery Offer Price Rs.11,000 Inclusive of Taxes Save Rs.9,000 1 Year Warranty. Part No K0

CALYS 50. Field multifunction calibrator for basic use

Warranty conditions are available on this website: only in English version

Hand-held temperature calibrator Model CEP3000

Main Features. Highlights

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Screw-in resistance thermometers with plug connector

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

Indoor, outdoor and duct resistance thermometers

500mW WIRELESS PHOTOCELL HL3-5x User s Manual Version 11/2017

Indeks: WMXXCMM60 Advanced Industrial Multimeter

RAY MC COMPACT ENERGY METER MECHANICAL

R-Log Radio data logger

Control solutions Biofloor

Dräger X-zone 5500 with Advanced 3D Communications

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

nvision Reference Recorder

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Resistance thermometer Model TR30, compact design

OFFSHORE ENERGY. BUYER S GUIDE HYDROlog Hydrotest Logger Range. Simply advanced

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Miniature resistance thermometer Model TR33, thread-mounted

PROCESS TOOLS SELECTION GUIDE

Pressure Transducer Handbook

Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

Transcription:

Application Multi branch systems The PFM 5000 is able to calculate complicated multi branch heating systems by simulating the hydraulic system using balancing calculations based on readings in each branch. This function drastically reduces the time required for balancing. PFM 5000 Multi Source Measuring accuracy The PFM 5000 has the advantage of high class digital technology which enables it to compensate for inaccuracies normally associated with pressure measurements, such as temperature dependency and non-linearity. PFM 5000 Standard The PFM 5000 has been designed to create hydraulic balance in heating and cooling systems. It enables measuring of pressure flow and temperatures in a system. Using differences in pressure the PFM 5000 is capable of turning these two pressures on both sides of a valve into flow. Flow through individual branches of the system can be measured, creating perfect balance in the whole system. Two separate units a main pressure unit for measuring pressure, flow and temperature a computing unit for displaying results and data analysis. The main pressure unit is designed with incoming by-pass couplers for hydraulic zero setting in order to increase the accuracy of low pressure measuring and to enable pressure connection deaeration. The PFM 5000 can be supplemented with an external thermometer connected via a coaxial connector. The temperature of the working medium can be measured by inserting the thermometer into the measuring nipples of the valve where you normally insert 3 mm measuring needles. Specifications for other valve manufacturers than Danfoss are pre-programmed in the memory of the PFM 5000. Autonomous measuring mode The PFM 5000 allows independent data recording based on a pre-programmed period. The acquired data are initially saved in the main pressure unit and can subsequently be analysed in the computing unit. The main pressure unit is extremely robust with a sturdy frame and sound cover. Inside the pressure unit is a differential pressure gauge with an integrated true differential pressure sensor for accurate digital data processing. The pressure gauge automatically corrects the flow for different types of mediums being measured, e.g., antifreeze additives in cooling systems. Danfoss Heating Solutions VDE2F202 Danfoss 04/2013 1

Features Separated main pressure unit and computing unit based on Smart Phone with Android OS (not iphone) connected by Bluetooth. Multi source version includes Converter Unit which converts Bluetooth to wireless communication in ISM band. Possible to choose from different pressure units (kpa, bar, etc.). Accurate pressure measuring with true differential pressure sensor and 24 bit ADC. Hydraulic by-pass for exact small differential pressure measuring. External PT-100 thermometer. Working with projects. Programmable autonomous recording mode. Main unit powered by rechargeable Li-Ion battery. Usage The PFM 5000 pressure unit must be connected on the high side as well as on the low side of the valve using the appropriate needles, connectors and hoses. If you are to measure under high static pressure it is recommended to connect the red hose first in order to protect the membrane inside the pressure unit. If you connect the blue hose first the pressure unit may be damaged. How to measure: 1. Select manufacturer 2. Select the type of valve 3. Select the dimension of the valve 4. Select pre-setting 5. Connect the valve to the pressure unit 6. Zero adjust 7. Measure the flow You can read flow and pressure on the Android mobile phone which is separate from the pressure unit. The maximum distance recommended between the Android mobile phone and the pressure unit is 30 meters. Dimensions 46 17 41 129 110 109 35 51,5 2 VDE2F202 Danfoss 04/2013 Danfoss Heating Solutions

Technical Specifications PFM 5000 Standard Type Pressure range Max. static pressure Max. over pressure Reliability, linearity and hysteresis error Temperature error Static pressure effect Medium temperature Ambient temperature Storage temperature Temperature probe Temperature measuring range Temperature measuring error Power Operating time Charging time Interface Communication speed RF transmitter power Radio range (open air) Recording period Specification 0-1000 kpa ~ 0-10 bar 0-2000 kpa ~ 0-20 bar 10 or 20 bar 1200 kpa ~ 12 bar 2200 kpa ~ 22 bar 0.15 % of range 0.25 % of range ± 200 Pa - 5 to 90 C (at end of connection tubes) - 5 to 50 C -10 to 70 C Pt 100 digital -20 to 120 C ± 1 C Li lon battery 3.6 V 950 mah (for Nokia 6230 mobile phone) Max. 120 hours 7 hours Bluetooth 57000 bps Class 1, 49 mw Up to 20 m 1 sec up to 24 hours Number of records Max. 3000 Dimensions w x h x d Weight 77 x 19 x 25 mm 620 g Cover IP 65 Calibration validity 12 months PFM 5000 Multi Source Type Pressure range Max. static pressure Max. over pressure Reliability, linearity and hysteresis error Temperature error Static pressure effect Medium temperature Ambient temperature Storage temperature Temperature probe Temperature measuring range Temperature measuring error Power Operating time Charging time Interface Specification 0-1000 kpa ~ 0-10 bar 0-2000 kpa ~ 0-20 bar 10 or 20 bar 1200 kpa ~ 12 bar 2200 kpa ~ 22 bar 0.15 % of range 0.25 % of range ± 200 Pa - 5 to 90 C (at end of connection tubes) - 5 to 50 C -10 to 70 C Pt 100 digital -20 to 120 C ± 1 C Li lon battery 3.6 V 950 mah (for Nokia 6230 mobile phone) Max. 120 hours 7 hours RF wireless 868 MHz Danfoss Heating Solutions VDE2F202 Danfoss 04/2013 3

Type Specification Communication speed 9600 bps RF transmitter power 25 mw Radio range (open air) Up to 30 m Wireless routers 868 MHz, 500 mw Number of routers max. 3 Radio range with 3 routers 300 m (open air) Recording period 1 sec up to 24 hours Number of records Max. 3000 Dimensions w x h x d 77 x 19 x 25 mm Weight 620 g Cover IP 65 Calibration validity 12 months Ordering PFM 5000 No. Type Set / pcs Danfoss code no. 1 PFM 5000 Standard 10 bar without mobile phone 1 003L8330 2 PFM 5000 Standard 20 bar without mobile phone 1 003L8331 3 PFM 5000 Multi Source 10 bar without mobile phone 1 003L8332 4 PFM 5000 Multi Source 20 bar without mobile phone 1 003L8333 5 PFM 5000 Standard 10 bar with mobile phone 1 003L8334 6 PFM 5000 Standard 20 bar with mobile phone 1 003L8335 7 PFM 5000 Multi Source 10 bar with mobile phone 1 003L8336 8 PFM 5000 Multi Source 20 bar with mobile phone 1 003L8337 PFM 5000 Standard contains one pressure transmitter. PFM 5000 Multi Source contains two pressure transmitters and one converter (routers available as accessories). Accessories No. Type Set / pcs Danfoss code no. 1 Measuring hose 2 x 1.5 m 2 003L8210 2 Battery for pressure unit 1 003L8214 3 Router with antenna 1 003L8215 4 Strap for pressure unit 1 003L8224 5 Filters for pressure unit 2 003L8231 6 AC adapter for pressure unit 1 003L8234 7 Quick coupling for measuring hose 1 003L8237 8 Plastic bracket for mounting 2 measuring needles 1 003L8251 9 Adapters DN15 x DN20 2 003L8272 10 Measuring adapter DN20 x 3 mm needle connection 1 003L8273 11 Measuring needles 2 003L8279 12 Temperature probe, 120 C, 3 mm 1 003L8288 13 TA adapters 2 003L8289 14 Hose adapter 1 003L8290 15 Converter - radio waves into Bluetooth 1 003L8338 16 PFM 5000 pressure unit Standard 10 bar 1 003L8220 17 PFM 5000 pressure unit Standard 20 bar 1 003L8221 4 VDE2F202 Danfoss 04/2013 Danfoss Heating Solutions

No. Type Set / pcs Danfoss code no. 18 PFM 5000 pressure unit Multi Source 10 bar 1 003L8222 19 PFM 5000 pressure unit Multi Source 20 bar 1 003L8223 Setup PFM 5000 ST PFM 5000 MS PFM 5000 ST PFM 5000 MS PFM 5000 MS max. 30 m max. 30 m max. 120 m R R R Pump PFM 5000 MS Chiller = Android OS = pressure unit ST = standard MS = Multi Source R = Router Max. distances: - between PFM and router max. 30 m - between 2 routers max. 120 m - between pressure unit and router max. 30 m If there is a long distance between the pressure transmitters and the mobile phone up to 3 routers can be used. For further information see the User Guide. Danfoss Heating Solutions VDE2F202 Danfoss 04/2013 5

6 VDE2F202 Danfoss 04/2013 Danfoss Heating Solutions

Danfoss Heating Solutions VDE2F202 Danfoss 04/2013 7

Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone: +45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. 8 VDE2F202 Danfoss 04/2013 Danfoss Heating Solutions