Agilent InfiniiMax III probing system

Similar documents
InfiniiMax III probing system

Keysight Technologies InfiniiMax III/III+ Probing System

Keysight Technologies InfiniiMax III/III+ Probing System

Keysight Technologies InfiniiMax III/III+ Probing System

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2750A/51A/52A InfiniiMode Differential Active Probes

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Agilent 8762F Coaxial Switch 75 ohm

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes


Keysight Technologies Infiniium Oscilloscope Probes and Accessories. Data Sheet

Solar Array Simulation System Integration

Agilent 8761A/B Microwave Switches

How Offset, Dynamic Range and Compression Affect Measurements

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Infiniium Oscilloscope Probes and Accessories

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Keysight Technologies Infiniium Oscilloscope Probes and Accessories. Data Sheet

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent NFA Noise Figure Analyzer

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Solutions for Solar Cell and Module Testing

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Evaluating Oscilloscope Bandwidths for your Application

Agilent NFA Noise Figure Analyzer

TriMode Probe Family P7700 Series TriMode Probes

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Advanced Test Equipment Rentals ATEC (2832)

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent U1730C Series Handheld LCR Meters

N9051A Pulse Measurement Software

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent NFA Noise Figure Analyzer

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Agilent 87075C Multiport Test Set

MXG X-Series Signal Generator N5183B Microwave Analog

Agilent N4916B De-emphasis Signal Converter

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Differential Probes P6248 P6247 P6246 Datasheet

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Keysight E5063A ENA Series Network Analyzer

Agilent MXG Signal Generators

Agilent U1240 Series Handheld Digital Multimeters

Essential Capabilities of EMI Receivers. Application Note

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent MXG Signal Generators

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent HMMC-3124 DC-12 GHz Packaged High Efficiency Divide-by-4 Prescaler 1GC TR1-7" diameter reel/500 each 1GC BLK-bubble strip/10 each

Evaluating Oscilloscopes for Low-Power Measurements

Advanced Test Equipment Rentals ATEC (2832)

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent U9391C/F/G Comb Generators

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Agilent N9320B RF Spectrum Analyzer

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

High-impedance Buffer Amplifier System

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

30 A AC/DC Current Probe TCP0030A Datasheet

AC Current Probes CT1 CT2 CT6 Data Sheet

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Passive Voltage Probes

AC/DC Current Probe TCP0150 Datasheet

Making a S11 and S21 Measurement Using the Agilent N9340A

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Transcription:

Agilent InfiniiMax III probing system Data Sheet World s highest speed and highest performing probe system Full 30 GHz bandwidth to the probe tip Industry s lowest probe and scope system noise Industry s highest fidelity and accuracy due to bandwidth and extremely low loading Probe amplifiers loaded with measured s-parameters for more accurate response correction Bandwidth upgradable Variety of probe heads for different use models with maximum usability Unmatched Performance Industry leading probe bandwidth The InfiniiMax III probing system offers you the highest performance available for measuring differential and single-ended signals, with flexible connectivity solutions for today s high-density ICs and circuit boards. Four different InfiniiMax III probe amplifiers ranging from 16 GHz to 30 GHz are available for matching your probing solution to your performance and budget requirements. A proprietary 200 GHz ft InP (indium phosphide) IC process with backside ground vias and novel thick film technology is utilized to accommodate your highest performance needs and is unmatched by any product in the market.

Highest fidelity and accuracy InfiniiMax III provides the highest bandwidth and incredibly low loading to allow for a new level of signal fidelity and accuracy. Continuing the probe head topology pioneered by Agilent in the InfiniiMax I and II probe systems, four new probe heads are provided to accommodate multiple use models: an 30 GHz browser that is extremely usable, an 28 GHz ZIF probe head with economical replaceable/ removable ZIF tips, an 28 GHz 2.92 mm probe head which allows cabled measurements using 2.92 mm, 3.5 mm, or SMA coax cables, and an economical 16 GHz solder-in probe head for less demanding measurements. Uncompromised Usability More accurate probe correction Each individual InfiniiMax III probe amplifier contains its own frequency response data. The 90000-X Series oscilloscopes download this data and automatically correct the response of the unique probe system. Traditionally, probe correction uses a nominal model based on a typical probe amplifier, not the specific amplifier being used. Generally, the biggest variation between probing systems is a result of the probe amplifier. The ability to correct a specific probe amplifier s response results in a more accurate probe correction, which yields a more accurate measurement. Correction No Correction 12 9 6 3 0-3 -6-9 -12-15 -18 1E8 1E9 1E10 4E10 Frequency Hz Extensive line-up of probe heads and accessories Agilent s InfiniiMax III probes support a wide variety of high-speed applications with an extensive line-up of probe heads and accessories. N5445A browser head (30 GHz) is the best choice for general-purpose trouble shooting of differential signals with z-axis compliance and variable spacing from 20 mil 125 mil (or 0.5 mm 3.1 mm). The span between the signal tips is easily adjusted with a thumb wheel on the browser. Integrated LED lighting at the tip illuminates the probing area for better visibility. Order N5476A for replacement browser tips (set of 4). 2

N5439A ZIF probe head provides 28 GHz bandwidth in an economical replaceable tip form factor. Because of their extremely low loading, the ZIF tips can be left on the DUT as the probe head is moved from one probing site to the next. Order N5440A (450 Ω) or N5447A (200 Ω) for a set of 5 ZIF tips with plastic sporks to aid in soldering the tips to your DUT. Variable spacing from 5 mil 80 mil (or 0.127 mm 2 mm). N5444A 2.92 mm/3.5 mm/sma probe head (28 GHz) allows you to connect two 2.92 mm, 3.5 mm or SMA cables to make a differential measurement on a single oscilloscope channel. Order N5448A 2.92 mm head flex cables (10 or 25 cm) to extend the cable length and add convenience. The N5444A provides for a termination to a common DC voltage rather than to ground, which is required for many signal standards. It is implemented such that from DC to ~1kHz the termination is 55 Ω to the termination voltage, and above ~10 khz the termination is 50 Ω to 0.9 times the termination voltage. The termination voltage range is ±4 V with a minimum step of 5 mv and a maximum current of 80 ma. The termination voltage can be controlled internally by the oscilloscope or applied externally using the supplied DC jack. N5441A solder-in probe head is an economical, semipermanent connection that provides up to 16 GHz of bandwidth. Variable span of the leads ranges from 5 mil 80 mil (or 0.127 mm 2 mm). 3

N5442A Precision BNC 50 Ω adapter allows you to use your existing InfiniiMax I (1130A-1134A), InfiniiMax II (1168A/69A), 1156A-58A active probes or a general purpose 50 Ω BNC cable with the Infiniium 90000-X Series oscilloscope. N5449A high impedance adapter allows the connection of probes that require a high impedance scope input such as a high impedance passive probe, 1147A current probe, or N2790A differential probe to the Infiniium 90000-X Series oscilloscopes. The N5449A provides switchable AC/DC coupling as well as 10:1 and 1:1 attenuation settings. The adapter comes with a N2873A 500 MHz 10:1 passive probe. N5477A sampling oscilloscope adapter makes the InfiniiMax III probing system fully compatible with the Infiniium 86100C DCA-J sampling oscilloscope. Previously the DCA-J was limited to 13 GHz of probing, but with the N5477A, the DCA-J now has 30 GHz of probing, increasing its performance and flexibility. N5443A performance verification and deskew fixture is required to calibrate and verify the performance of the InfiniiMax III probe. Agilent is currently the only oscilloscope vendor in the market that provides the hardware for the customer to validate their high performance probing system. Bandwidth upgradeability As frequencies have continued to increase, so have the cost of probes. The InfiniiMax III system offers the world s first fully upgradeable probe amplifier. Purchase a 16 GHz probe amplifier today, knowing that in the future, you can upgrade the amplifier to higher bandwidths (20/25/30 GHz) at a fraction of the cost of a new probe amplifier. 4

InfiniiMax III probing system family diagram DCA-J 86100 Wideband Oscilloscope 90000-X Series Oscilloscope N5477A Sampling Scope Adapter N5442A Precision BNC 50 Ω Adapter N5449A High Impedance Adapter PV/Deskew Fixture and Stand (properly positions probe for PV testing) InfiniiMax III Amplifiers N2800A (16 GHz) N2801A (20 GHz) N2802A (25 GHz) N2803A (30 GHz) 50 Ω Autoprobe Probes (InfiniiMax I or II probes, 1156A-58A probes, etc.) N2873A 500 MHz Passive Probe (or other similar probes**) 1147A Current Probe or N2790A High Voltage Differential Probe (or other similar probes***) N5439A ZIF Probe Head N5447A 200 Ω ZIF Tip (high sensitivity) N5440A 450 Ω ZIF Tip (normal sensitivity) N5444A 2.92mm/3.5mm/SMA Probe Head N5441A Solder-in Probe Head (16 GHz max) N5445A Browser Probe Head N5448A 2.92mm Extension Cables (optional - used in place of supplied semi-rigid cable set) *Components are not drawn to scale. **The N5449A includes one N2873A probe. The adapter is specifically tuned for the N2873A probe, but other similar probes (1 MΩ input) can be used. Other probes may not meet the bandwidth specification. ***The N5449A is also compatible with other similar active probes with the Autoprobe interface and outputs designed to drive 1 MΩ inputs. 5

Performance characteristics (of N2803A, 30 GHz probe amplifer, with each probe head) N2802A: BW=25 GHz, tr=17.4 psec N2801A: BW=20 GHz, tr=21.7 psec N2800A: BW=16 GHz, tr=27.1 psec Probe bandwidth (-3dB), probe only N2803A with N5439A and N5447A (ZIF 200Ω) Rise and fall time, probe only 20.9 psec (10-90%), 13.8 psec (20-80%) System bandwidth (-3dB) with DSO/DSAX93204A Rise and fall time with DSO/DSAX93204A N2803A with N5439A and N5440A (ZIF 450Ω) 28 GHz (typical) 28 GHz (typical), 26 GHz* (warranted) 20.9 psec (10-90%), 13.8 psec (20-80%) N2803A with N5445A (browser) 30 GHz (typical), 28 GHz* (warranted) 16.2 psec (10-90%), 10.9 psec (20-80%) N2803A with N5441A (solder-in) 17.2 GHz (typical) 28 GHz 34.8 psec (10-90%), 26.6 psec (20-80%) 28 GHz 28 GHz 30 GHz 16 GHz 28 GHz 15.5 psec (10-90%) 11.0 psec (20-80%) 15.5 psec (10-90%) 11.0 psec (20-80%) 14.3 psec (10-90%) 10.2 psec (20-80%) 27.1 psec (10-90%) 19.2 psec (20-80%) N2803A with N5444A (SMA adapter) 18.8 psec (10-90%), 12.7 psec (20-80%) 15.5 psec (10-90%) 11.0 psec (20-80%) Input capacitance Cdiff=32fF, Cse=44fF Cdiff=32fF, Cse=44fF Cdiff=35fF, Cse=50fF Cdiff=77fF, Cse=105fF N/A DC input resistance* Rdiff = 50 kω ± 2%, Rse = 25 kω ± 2% Rdiff = 100 kω ± 2%, Rse = 50 kω ± 2% 55 Ω to Vterm Input resistance >10 khz Input voltage range (differential or single-ended) Input common mode range Rdiff = 500 Ω, Rse = 250 Ω 0.8Vpp, ±0.4V (HD2&3<-38db), 1.6Vpp, ±0.8V (HD2&3<-34db)** ±6V DC to 250Hz ±1.25V > 250Hz 1.6Vpp, ±0.8V (HD2&3 <-38db), 2.5Vpp, ±1.25V (HD2&3 <-34db)** ±12V DC to 250Hz ±2.5V > 250Hz Rdiff = 1 K Ω, Rse = 500 Ω 1.6Vpp, ±0.8V (HD2&3 <-38db), 2.5Vpp, ±1.25V (HD2&3<-34db)** ±12V DC to 250Hz ±2.5V > 250Hz 50 Ω to 0.909x Vterm 2.5 Vrms ±12V DC to 250Hz ±2.5V > 250Hz (must not exceed max input voltage) DC attenuation ratio 3:1 6:1 6:1 Offset range ±16V when probing a single-ended signal ±16V when probing a single-ended signal ±16V when probing a single-ended signal ±16V when probing a single-ended signal (must not exceed max input voltage) Noise referenced to input, probe only 2mVrms 4mVrms Maximum input voltage 18V peak Cat I Same as input voltage range * Denotes warranted characteristic. All others are typical. ** Harmonic distortion < -38dB is standard; < -34dB wider input range with slightly increased distortion 6

Ordering Information InfiniiMax III probe amplifier models Model Number Description Recommended oscilloscope N2803A 30 GHz InfiniiMax III probe amplifier DSO/DSAX93204A 32 GHz Infiniium oscilloscope DSO/DSAX92804A 28 GHz Infiniium oscilloscope N2802A 25 GHz InfiniiMax III probe amplifier DSO/DSAX92504A 25 GHz Infiniium oscilloscope N2801A 20 GHz InfiniiMax III probe amplifier DSO/DSAX92004A 20 GHz Infiniium oscilloscope N2800A 16 GHz InfiniiMax III probe amplifier DSO/DSAX91604A 16 GHz Infiniium oscilloscope Note: N2800A-N2803A InfiniiMax probe amps are not compatible with existing InfiniiMax I or II probe heads. InfiniiMax III probe heads Model Number Description Notes N5445A InfiniiMax III browser head Order N5476A for replacement probe tips (set of 4) N5439A InfiniiMax III ZIF probe head Order N5440A (450 Ω) or N5447A (200 Ω) for a set of 5 ZIF tips with plastic sporks. N5444A InfiniiMax III 2.92 mm/3.5 mm/sma probe head Order N5448A 2.92 mm head flex cables to extend the cable length. N5441A InfiniiMax lll solder-in probe head Note: N54xxA InfiniiMax III probe heads are not compatible with InfiniiMax I or II probe amps. InfiniiMax III probe adapters Model Number Description Notes N5442A Precision BNC adapter (50 Ω) For use with InfiniiMax I and II probes, 1156A-58A etc. N5449A High impedance probe adapter Includes one N2873A 500MHz 10:1 passive probe N5477A Sampling scope adapter For use with Agilent 86100C DCA-J sampling scope N5443A Performance verification and deskew fixture Probe bandwidth upgrade options Model Number Description Notes N5446A 16 GHz to 20 GHz bandwidth upgrade N5446B 20 GHz to 25 GHz bandwidth upgrade N5446C 25 GHz to 30 GHz bandwidth upgrade Note: Purchase two or more upgrade options to go from 16 to 25 or 30 GHz and 20 to 30 GHz. To upgrade the probe bandwidth, you simply need to send the probe to the Agilent service center. Other recommended accessories for InfiniiMax III probing system Model Number Description Notes N2787A 3D probe positioner For hands-free probing N2812A High performance input cable, 2.92 mm connectors, 1 m length For use with Infiniium 90000-X Series oscilloscope MV-23 Carson Optical MagniVisor www.carsonoptical.com/magnifiers Note: Purchase two or more upgrade options to go from 16 to 25 or 30 GHz and 20 to 30 GHz. 7

www.agilent.com www.agilent.com/find/infiniimax3 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Windows is a U.S. registered trademark of Microsoft Corporation. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Latin America 305 269 7500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: July 8, 2010 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2010 Printed in USA, November 24, 2010 5990-5653EN