InfiniiMax III probing system

Similar documents
Agilent InfiniiMax III probing system

Keysight Technologies InfiniiMax III/III+ Probing System

Keysight Technologies InfiniiMax III/III+ Probing System

Keysight Technologies InfiniiMax III/III+ Probing System

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2750A/51A/52A InfiniiMode Differential Active Probes

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies Infiniium Oscilloscope Probes and Accessories. Data Sheet

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent NFA Noise Figure Analyzer

How Offset, Dynamic Range and Compression Affect Measurements

Keysight Technologies Infiniium Oscilloscope Probes and Accessories. Data Sheet

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Agilent U9391C/F/G Comb Generators

MXG X-Series Signal Generator N5183B Microwave Analog

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Essential Capabilities of EMI Receivers. Application Note

Evaluating Oscilloscopes for Low-Power Measurements

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes


Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Infiniium Oscilloscope Probes and Accessories

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Agilent NFA Noise Figure Analyzer

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

TriMode Probe Family P7700 Series TriMode Probes

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent U1730C Series Handheld LCR Meters

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Agilent First-generation MXG Signal Generators

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Agilent N432A Thermistor Power Meter

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent N4916B De-emphasis Signal Converter

Keysight E5063A ENA Series Network Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Agilent 8761A/B Microwave Switches

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies Oscilloscope Probe Loading Experiment

The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 khz a capability typically found

Differential Probes P6248 P6247 P6246 Datasheet

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Introduction. Part 1. Introduction...2

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Agilent 8762F Coaxial Switch 75 ohm

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Keysight Technologies U1730C Series Handheld LCR Meters Take your expectations higher with the latest LCR meters. Data Sheet

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Agilent N9320B RF Spectrum Analyzer

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Advanced Test Equipment Rentals ATEC (2832)

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Agilent N9342C Handheld Spectrum Analyzer (HSA)

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Keysight Technologies N2114A and N2115A DDR4 BGA Interposers for Infiniium Oscilloscopes

Agilent NFA Noise Figure Analyzer

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Agilent U1230 Series Handheld Digital Multimeter (DMM)

N9051A Pulse Measurement Software

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Advanced Test Equipment Rentals ATEC (2832)

Transcription:

InfiniiMax III probing system Data Sheet World s highest speed and highest performing probe system Full 30 GHz bandwidth to the probe tip Industry s lowest probe and scope system noise Industry s highest fidelity and accuracy due to bandwidth and extremely low loading Probe amplifiers loaded with measured s-parameters for more accurate response correction Bandwidth upgradable Variety of probe heads for different use models with maximum usability Unmatched Performance Industry leading probe bandwidth The InfiniiMax III probing system offers you the highest performance available for measuring differential and single-ended signals, with flexible connectivity solutions for today s high-density ICs and circuit boards. Four different InfiniiMax III probe amplifiers ranging from 16 GHz to 30 GHz are available for matching your probing solution to your performance and budget requirements. A proprietary 200 GHz ft InP (indium phosphide) IC process with backside ground vias and novel thick film technology is utilized to accommodate your highest performance needs and is unmatched by any product in the market.

Highest fidelity and accuracy InfiniiMax III provides the highest bandwidth and incredibly low loading to allow for a new level of signal fidelity and accuracy. Continuing the probe head topology pioneered by Agilent in the InfiniiMax I and II probe systems, four new probe heads are provided to accommodate multiple use models: an 30 GHz browser that is extremely usable, an 25/28 GHz ZIF probe head with economical replaceable/ removable ZIF tips, an 28 GHz 2.92 mm probe head which allows cabled measurements using 2.92 mm, 3.5 mm, or SMA coax cables, and an economical 16/26 GHz solder-in probe head for demanding measurements. Uncompromised Usability More accurate probe correction Each individual InfiniiMax III probe amplifier contains its own frequency response data. The 90000-X/Q Series oscilloscopes download this data and automatically correct the response of the unique probe system. Traditionally, probe correction uses a nominal model based on a typical probe amplifier, not the specific amplifier being used. Generally, the biggest variation between probing systems is a result of the probe amplifier. The ability to correct a specific probe amplifier s response results in a more accurate probe correction, which yields a more accurate measurement. Correction No Correction 12 9 6 3 0-3 -6-9 -12-15 -18 1E8 1E9 1E10 4E10 Frequency Hz Extensive line-up of probe heads and accessories Agilent s InfiniiMax III probes support a wide variety of high-speed applications with an extensive line-up of probe heads and accessories. N5445A browser head (30 GHz) is the best choice for general-purpose trouble shooting of differential signals with z-axis compliance and variable spacing from 20 mil 125 mil (or 0.5 mm 3.1 mm). The span between the signal tips is easily adjusted with a thumb wheel on the browser. Integrated LED lighting at the tip illuminates the probing area for better visibility. Order N5476A for replacement browser tips (set of 4). 2

N5439A ZIF probe head provides 28 GHz bandwidth in an economical replaceable tip form factor. Because of their extremely low loading, the ZIF tips can be left on the DUT as the probe head is moved from one probing site to the next. Order N5440A (450 Ω ceramic), N5447A (200 Ω ceramic) or the new N2838A (450 Ω PC board) for a set of 5 ZIF tips with plastic sporks to aid in soldering the tips to your DUT. The N2838A PC board ZIF tip increased the robustness of the ZIF tip significantly while maintaining the bandwidth performance up to 25 GHz when used in conjunction with the N2803A and N5439A. Variable spacing from 5 mil 80 mil (or 0.127 mm 2 mm). N5444A 2.92 mm/3.5 mm/sma probe head (28 GHz) allows you to connect two 2.92 mm, 3.5 mm or SMA cables to make a differential measurement on a single oscilloscope channel. Order N5448A 2.92 mm head flex cables (10 or 25 cm) to extend the cable length and add convenience. The N5444A provides for a termination to a common DC voltage rather than to ground, which is required for many signal standards. It is implemented such that from DC to ~1kHz the termination is 55 Ω to the termination voltage, and above ~10 khz the termination is 50 Ω to 0.9 times the termination voltage. The termination voltage range is ±4 V with a minimum step of 5 mv and a maximum current of 80 ma. The termination voltage can be controlled internally by the oscilloscope or applied externally using the supplied DC jack. N5441A solder-in probe head is an economical, semipermanent connection that provides up to 16 GHz of bandwidth. Variable span of the leads ranges from 5 mil 80 mil (or 0.127 mm 2 mm). 3

N2836A solder-in head provides up to 26 GHz bandwidth when used in conjunction with the N2803A probe amplifier. N5442A Precision BNC 50 Ω adapter allows you to use your existing InfiniiMax I (1130A-1134A), InfiniiMax II (1168A/69A), 1156A-58A active probes or a general purpose 50 Ω BNC cable with the Infiniium 90000-X Series oscilloscope. N5449A high impedance adapter allows the connection of probes that require a high impedance scope input such as a high impedance passive probe, 1147B current probe, or N2790A differential probe to the Infiniium 90000-X Series oscilloscopes. The N5449A provides switchable AC/DC coupling as well as 10:1 and 1:1 attenuation settings. The adapter comes with a N2873A 500 MHz 10:1 passive probe. N5477A sampling oscilloscope adapter makes the InfiniiMax III probing system fully compatible with the Infiniium 86100C DCA-J sampling oscilloscope. Previously the DCA-J was limited to 13 GHz of probing, but with the N5477A, the DCA-J now has 30 GHz of probing, increasing its performance and flexibility. N5443A performance verification and deskew fixture is required to calibrate and verify the performance of the InfiniiMax III probe. Agilent is currently the only oscilloscope vendor in the market that provides the hardware for the customer to validate their high performance probing system. Bandwidth upgradeability As frequencies have continued to increase, so have the cost of probes. The InfiniiMax III system offers the world s first fully upgradeable probe amplifier. Purchase a 16 GHz probe amplifier today, knowing that in the future, you can upgrade the amplifier to higher bandwidths (20/25/30 GHz) at a fraction of the cost of a new probe amplifier. 4

InfiniiMax III probing system family diagram 5

Performance characteristics (of N2803A, 30 GHz probe amplifer, with each probe head) N2802A: BW=25 GHz, tr=17.4 psec N2801A: BW=20 GHz, tr=21.7 psec N2800A: BW=16 GHz, tr=27.1 psec Probe bandwidth (-3dB), probe only N2803A with N5439A and N5447A (Ceramic ZIF 200Ω) Rise and fall time, probe only 20.9 psec (10-90%), 13.8 psec (20-80%) System bandwidth (-3dB) with DSO/DSAX93204A Rise and fall time with DSO/DSAX93204A N2803A with N5439A and N5440A (Ceramic ZIF 450Ω) /N2838A (PCB ZIF 450 Ω) 28 GHz (typical) 28 GHz (typical), 26 GHz* (warranted) /25 GHz (typical) 20.9 psec (10-90%), 13.8 psec (20-80%)/ 23.1 psec (10-90%) 14.9 psec (20-80%) N2803A with N5445A (browser) 30 GHz (typical), 28 GHz* (warranted) 16.2 psec (10-90%), 10.9 psec (20-80%) N2803A with N5441A (16 GHz solder-in)/ N2836A (26 GHz solder-in) 17.2 GHz (typical)/ 27 GHz (typical) 34.8 psec (10-90%), 26.6 psec (20-80%)/ 21.1 psec (10-90%) 13.8 psec (20-80%) N2803A with N5444A (SMA adapter) 28 GHz 28 GHz 28 GHz/25 GHz 30 GHz 16 GHz /26 GHz 28 GHz 15.5 psec (10-90%) 11.0 psec (20-80%) 15.5 psec (10-90%) 11.0 psec (20-80%)/ 17.6 psec (10-90%) 12.5 psec (20-80%) Input capacitance Cdiff=32fF, Cse=44fF/ Cdiff=32fF,Cse=44fF/ Cdiff=95 ff, Cse=130 ff DC input resistance* Rdiff=50 kω ±2%, Rse=25 kω ±2% Input resistance >10 khz Rdiff=500 Ω, Rse=250 Ω Input voltage range (differential or single-ended) Input common mode range 0.8Vpp, ±0.4V (HD2&3 <-38db), 1.6Vpp, ±0.8V (HD2&3<-34db)** ±6V DC to 250Hz ±1.25V > 250Hz 14.3 psec (10-90%) 10.2 psec (20-80%) Cdiff=35fF, Cse=50fF Rdiff=100 kω ±2%, Rse=50 kω ±2% Rdiff=1 kω Rse=500 Ω 1.6Vpp, ±0.8V (HD2&3 <-38db), 2.5Vpp, ±1.25V (HD2&3<-34db)** ±12V DC to 250Hz ±2.5V > 250Hz 27.1 psec (10-90%) 19.2 psec (20-80%)/ 16.5 psec (10-90%) 11.7 psec (20-80%) Cdiff=77fF, Cse=105fF/ Cdiff=108 ff, Cse=140 ff 18.8 psec (10-90%), 12.7 psec (20-80%) 15.5 psec (10-90%) 11.0 psec (20-80%) N/A 55 Ω to Vterm 50 Ω to 0.909x Vterm 2.5 Vrms ±12V DC to 250Hz ±2.5V > 250Hz (must not exceed max input voltage) DC attenuation ratio 3:1 6:1 Offset range ±16V when probing a single-ended signal ±16V when probing a single-ended signal (must not exceed max input voltage) Noise referenced to input, probe only 2mVrms 4mVrms Maximum input voltage 18V peak CAT I Same as input voltage range * Denotes warranted characteristic. All others are typical. ** Harmonic distortion < -38dB is standard; < -34dB wider input range with slightly increased distortion 6

Ordering Information InfiniiMax III probe amplifier models Model Number Description Recommended oscilloscope N2803A 30 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q Series 28 GHz - 63 GHz models N2802A 25 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q Series 25 GHz models N2801A 20 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q Series 20 GHz models N2800A 16 GHz InfiniiMax III probe amplifier Infiniium 90000X Series 16 GHz models Note: N2800A-N2803A InfiniiMax probe amps are not compatible with existing InfiniiMax I or II probe heads. InfiniiMax III probe heads Model Number Description Notes N5445A InfiniiMax III browser head Order N5476A for replacement probe tips (set of 4) N5439A InfiniiMax III ZIF probe head Order N2838A PC board ZIF (450 Ω), N5440A Ceramic ZIF (450 Ω) or N5447A Ceramic ZIF (200 Ω) for a set of 5 ZIF tips with plastic sporks. N5444A InfiniiMax III 2.92 mm/3.5 mm/sma probe head Order N5448A 2.92 mm head flex cables to extend the cable length. N5441A N2836A InfiniiMax lll 16 GHz solder-in probe head InfiniiMax III 26 GHz solder-in probe head Note: N54xxA InfiniiMax III probe heads are not compatible with InfiniiMax I or II probe amps. InfiniiMax III probe adapters Model Number Description Notes N5442A Precision BNC adapter (50 Ω) For use with InfiniiMax I and II probes, N2750A-52A, 1156A-58A etc. N5449A High impedance probe adapter Includes one N2873A 500MHz 10:1 passive probe N5477A Sampling scope adapter For use with Agilent 86100C DCA-J sampling scope N5443A Probe bandwidth upgrade options Performance verification and deskew fixture Model Number Description Notes N5446A-001 N5446A-002 N5446A-003 N5446A-004 N5446A-005 N5446A-006 16 GHz to 20 GHz bandwidth upgrade 20 GHz to 25 GHz bandwidth upgrade 25 GHz to 30 GHz bandwidth upgrade 16 GHz to 25 GHz bandwidth upgrade 16 GHz to 30 GHz bandwidth upgrade 20 GHz to 30 GHz bandwidth upgrade Note: Purchase two or more upgrade options to go from 16 to 25 or 30 GHz and 20 to 30 GHz. To upgrade the probe bandwidth, you simply need to send the probe to the Agilent service center. Other recommended accessories for InfiniiMax III probing system Model Number Description Notes N2787A 3D probe positioner For hands-free probing N2812A High performance input cable, 2.92 mm For use with Infiniium 90000-X/Q Series oscilloscope connectors, 1 m length MV-23 Carson Optical MagniVisor www.carsonoptical.com/magnifiers Note: Purchase two or more upgrade options to go from 16 to 25 or 30 GHz and 20 to 30 GHz. 7

www.agilent.com www.agilent.com/find/infiniimax3 myagilent myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. Three-Year Warranty www.agilent.com/find/threeyearwarranty Agilent s combination of product reliability and three-year warranty coverage is another way we help you achieve your business goals: increased confidence in uptime, reduced cost of ownership and greater convenience. Agilent Advantage Services www.agilent.com/find/advantageservices Accurate measurements throughout the life of your instruments. Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP2-19-13) Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2012, 2013 Published in USA, April 1, 2013 5990-5653EN