12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum conductor temperature : 90 o C 1 - Conductor Bare or tinned copper Flexible-class 5 NF C -013 IEC 228 2 - Insulation Thermoplastic rubber 3 - Outersheath Thermoplastic rubber colour : black N.B.: Colours and other constructional details can be according to customer special requirements. Marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application These cables are designed for submersible power supply used into water. 1 2 3 48
450 / 750 V THERMOPLASTIC RUBBER ROUND FLEXIBLE CABLE CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 90 o C 50Hz o C Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) Outerdiam. Min. Max. Min. bending radius ➀ Weight approx. (kg/km) 3 G 1.5 3 G 2.5 3 G 4 3 G 6 3 G 10 3 G 16 3 G 25 3 G 35 3 G 50 33 45 58 107 142 175 212 2 16.9 10.5 7.0 4.0 2.5 1.68 1.22 0.87 9.6 11.5 13.0 20.0 22.5 34.5 16.0 20.0 25.5 34.0 3 44.0 50 60 105 120 140 155 1 160 220 0 0 720 1010 1450 1900 25 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 22 40 52 71 127 1 190 23.3 14.0 8.74 5.86 3.44 2.21 1.46 7 0.78 10.5 16.5.5 33.0 3 13.5 15.5 1 22.0 2.0 37.5 42.0 48.5 55 75 90 115 1 150 170 200 195 270 3 520 900 1260 1850 00 90 G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available 49
12 SUBMERSIBLE PUMP CABLES 12.2-0.6 / 1 K/V PE / PE Round Cables Maximum conductor temperature : 70 o C 1 - Conductor Flexible bare copper class 5 NF C -013 IEC 228 2 - Insulation 3 - Outersheath colour : black N.B.: Colours and other constructional details can be according to customer special requirements. (+ green / yellow conductor when required) Sheath marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application Submersible pump power supply cables must have excellent water tightness and very good insulation. is the material that best meets these requirements. The special PVC sheath improves the cable flexibility compared to a PE sheath. The designed materials are suitable for use in drinking water. Cables with food-grade flexible PVC sheath, can also be manufactured Use ambient temperature : in the water : up to 40 o C in the air : -20 o C to + 60 o C Maximum use depth : up to 200 m. 1 2 3 50
0.6 / 1KV PE / PE ROUND CABLES CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 70 o C 50Hz o C Technical Data PE / PE Round cables Specifications can change according to customer requirements Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) Outerdiam. Min. Max. Min. bending radius ➀ Weight approx. (kg/km) 3 x 1.5 3 x 2.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 184 223 259 0.55 0.42 0.35 10.0 1 12.0 1 15.1 17.2 23.5 27.4 31.8 36.5 40.0 1 1 16.6 18.8 23.5.0 35.0 40.0 44.0 70 75 90 100 115 145 160 1 210 0 260 1 170 220 285 4 0 1 020 1 0 1 810 2 620 3 0 4 200 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 10.5 11.5 14.0 16.0 19.5.0.0 11.6 13.0 14.0 15.5 1 22.0 33.0 70 85 95 110 135 160 1 200 150 200 270 350 540 820 1 290 1 6 2 0 Also single core cables : on special request G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available Ambient temperature o C 5 10 15 20 25 35 40 45 50 55 60 Correction factors 1.27 1.22 1.17 1.12 6 0 0.94 0.87 0.79 0.71 0.61 0.50 51
12 SUBMERSIBLE PUMP CABLES 12.3-0.6 / 1 K/V PE / PE Flat Flexible Cables Maximum conductor temperature : 70 o C 1 - Conductor Flexible bare copper class 5 NF C -013 IEC 228 2 - Insulation 3 - Outer shearth colour : black N.B.: Colours and other constructional details can be according to customer special requirements. Core Identification According to customer requirements (+ green / yellow for 4 core cables). Laying up Conductors are side by side and parallel. Sheath marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application Submersible pump power supply cables must have excellent water tightness and very good insulation. is the material that best meets these requirements. The flat shape makes it possible to obtain smaller overall dimensions and a tighter bending radius. The designed materials are suitable for use in drinking water. Cables with food grade flexible PVC sheath, can also be manufactured. Use ambient temperature : in the water : up to 40 o C in the air : -20 o C to + 60 o C Maximum use depth : up to 200 m. 1 2 3 52
0.6 / 1 KV PE / PE FLAT FLEXIBLE CABLE CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 70 o C 50Hz o C Technical Data PE / PE Flat cables Specifications can change according to customer requirements Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) External nominal dimensions Min. bending radius ➀ Weight approx. (kg/km) 3 x 1.5 3 x 2.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 184 0.55 13.1 x 5.7 14.4 x 5.6 15.9 x 6.5 18.4 x 7.2 21.6 x 8.8 26.4 x 10.5.4 x 1 36.0 x 14.4 39.7 x 15.9 47.5 x 18.9 25 25 40 45 55 60 90 125 1 235 390 600 920 1 2 1 720 2 460 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 15.8 x 5.0 19.5 x 5.6 x 6.5 23.6 x 7.2 29.1 x 8.8 35.3 x 10.4 43.6 x 1 48.4 x 14.4 53.5 x 15.9 20 25 40 45 55 60 115 170 0 3 5 810 1 220 1 700 2 500 G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available Ambient temperature o C 5 10 15 20 25 35 40 45 50 55 60 Correction factors 1.27 1.22 1.17 1.12 6 0 0.94 0.87 0.79 0.71 0.61 0.50 53