SUBMERSIBLE PUMP CABLES

Similar documents
HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

FieldLink MC at 20 x outer diameter Torsion

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Welding Cables Rubber Insulated

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Tri-Rated Flexible PVC Equipment Wire

Medium Voltage Power Cables

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

kv: medium voltage reeling cable with fibreoptics

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

NETWORK CONNECTIVITY SYSTEMS

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Selection table for flat & ribbon cables

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Armoured Power and Control Cables to BS7917

CABLES AND WIRES

Electric cables. Cranes

Armoured Power and Control Cables Fire Resistant

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

Motor, Servo & Feedback Cables

BUS cable. BUS cable. Cables for use in automation- and communication technique.

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

Servo Cable Selection

MV water-proof and water tree retardant power cable

FLEXIBLE MULTI CORE CABLES

CIR (Crush & Impact Resistant) VFD Power Cable

IEC Standard Caledonian Offshore & Marine Cables

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

CAT 5e UTP Cable: NETSET BOX [305m], indoor

P Low Voltage Catalogue Cables Australia Powering your Project

Instrumentation Cables

TRAXLINE CABLES FOR MOTION

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

MarineLine YOZp 0,6/1 kv

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

EXCELLENT ELECTRICAL PERFORMANCES

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

List Price w.e.f. 02nd January, 2018

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

ABOUT US ABOUT US 1 CRANE CABLES

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

UNIRAIL D RS485 and BUS cables

SAC-5P- 1,5-PUR/M12FS SH

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

EDS LV WAVEFORM MAINS CABLE RATINGS

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

H05Z-K / H07Z-K BS EN LSZH Wire

TIGER BRAND MINING CABLES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Armoured Power and Control Cables to BS6883

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

REPORT OF PERFORMANCE TIC

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

MULTIMEDIA CABLE H6091ZHB

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

THE WORLD OF LAPP. Cables for power chains

Power Cables and their Application

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

Marine Cables General Catalogue

SAC-3P- 5,0-PUR/M12FR SH

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Installation Recommendations

gesis MINI 2, 3 and 5 pole

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Chapter Seven. Under Ground Cables

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

16-2-C Series. Specification Table. Page <1> 19/06/10 V1.0. : Varies with colour and packing.

Complete, innovative cables range for shipbuilding industry

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Flexitime! Our flexible cables save you time and money.

H07RN-F BS EN Flexible Rubber Cable

15 years of experience

Kerman & Kavian Cable Industries ( KCI )

COPPER + LWL RAW CABLES

Transcription:

12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum conductor temperature : 90 o C 1 - Conductor Bare or tinned copper Flexible-class 5 NF C -013 IEC 228 2 - Insulation Thermoplastic rubber 3 - Outersheath Thermoplastic rubber colour : black N.B.: Colours and other constructional details can be according to customer special requirements. Marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application These cables are designed for submersible power supply used into water. 1 2 3 48

450 / 750 V THERMOPLASTIC RUBBER ROUND FLEXIBLE CABLE CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 90 o C 50Hz o C Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) Outerdiam. Min. Max. Min. bending radius ➀ Weight approx. (kg/km) 3 G 1.5 3 G 2.5 3 G 4 3 G 6 3 G 10 3 G 16 3 G 25 3 G 35 3 G 50 33 45 58 107 142 175 212 2 16.9 10.5 7.0 4.0 2.5 1.68 1.22 0.87 9.6 11.5 13.0 20.0 22.5 34.5 16.0 20.0 25.5 34.0 3 44.0 50 60 105 120 140 155 1 160 220 0 0 720 1010 1450 1900 25 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 22 40 52 71 127 1 190 23.3 14.0 8.74 5.86 3.44 2.21 1.46 7 0.78 10.5 16.5.5 33.0 3 13.5 15.5 1 22.0 2.0 37.5 42.0 48.5 55 75 90 115 1 150 170 200 195 270 3 520 900 1260 1850 00 90 G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available 49

12 SUBMERSIBLE PUMP CABLES 12.2-0.6 / 1 K/V PE / PE Round Cables Maximum conductor temperature : 70 o C 1 - Conductor Flexible bare copper class 5 NF C -013 IEC 228 2 - Insulation 3 - Outersheath colour : black N.B.: Colours and other constructional details can be according to customer special requirements. (+ green / yellow conductor when required) Sheath marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application Submersible pump power supply cables must have excellent water tightness and very good insulation. is the material that best meets these requirements. The special PVC sheath improves the cable flexibility compared to a PE sheath. The designed materials are suitable for use in drinking water. Cables with food-grade flexible PVC sheath, can also be manufactured Use ambient temperature : in the water : up to 40 o C in the air : -20 o C to + 60 o C Maximum use depth : up to 200 m. 1 2 3 50

0.6 / 1KV PE / PE ROUND CABLES CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 70 o C 50Hz o C Technical Data PE / PE Round cables Specifications can change according to customer requirements Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) Outerdiam. Min. Max. Min. bending radius ➀ Weight approx. (kg/km) 3 x 1.5 3 x 2.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 184 223 259 0.55 0.42 0.35 10.0 1 12.0 1 15.1 17.2 23.5 27.4 31.8 36.5 40.0 1 1 16.6 18.8 23.5.0 35.0 40.0 44.0 70 75 90 100 115 145 160 1 210 0 260 1 170 220 285 4 0 1 020 1 0 1 810 2 620 3 0 4 200 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 10.5 11.5 14.0 16.0 19.5.0.0 11.6 13.0 14.0 15.5 1 22.0 33.0 70 85 95 110 135 160 1 200 150 200 270 350 540 820 1 290 1 6 2 0 Also single core cables : on special request G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available Ambient temperature o C 5 10 15 20 25 35 40 45 50 55 60 Correction factors 1.27 1.22 1.17 1.12 6 0 0.94 0.87 0.79 0.71 0.61 0.50 51

12 SUBMERSIBLE PUMP CABLES 12.3-0.6 / 1 K/V PE / PE Flat Flexible Cables Maximum conductor temperature : 70 o C 1 - Conductor Flexible bare copper class 5 NF C -013 IEC 228 2 - Insulation 3 - Outer shearth colour : black N.B.: Colours and other constructional details can be according to customer special requirements. Core Identification According to customer requirements (+ green / yellow for 4 core cables). Laying up Conductors are side by side and parallel. Sheath marking - Name of manufacturer - Metric marking - Size - Other : as per customer requirements Application Submersible pump power supply cables must have excellent water tightness and very good insulation. is the material that best meets these requirements. The flat shape makes it possible to obtain smaller overall dimensions and a tighter bending radius. The designed materials are suitable for use in drinking water. Cables with food grade flexible PVC sheath, can also be manufactured. Use ambient temperature : in the water : up to 40 o C in the air : -20 o C to + 60 o C Maximum use depth : up to 200 m. 1 2 3 52

0.6 / 1 KV PE / PE FLAT FLEXIBLE CABLE CURRENT RATING GENERAL CONDITIONS The following current data are indicated for continuous duty operation and apply to : Maximum conductor temperature Industrial frequency Free air ambient temperature 70 o C 50Hz o C Technical Data PE / PE Flat cables Specifications can change according to customer requirements Cables (mm 2 ) Permissible current rating (A) Voltage drop cos ϕ = 0.8 (V/Ax km) External nominal dimensions Min. bending radius ➀ Weight approx. (kg/km) 3 x 1.5 3 x 2.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 184 0.55 13.1 x 5.7 14.4 x 5.6 15.9 x 6.5 18.4 x 7.2 21.6 x 8.8 26.4 x 10.5.4 x 1 36.0 x 14.4 39.7 x 15.9 47.5 x 18.9 25 25 40 45 55 60 90 125 1 235 390 600 920 1 2 1 720 2 460 4 G 1.5 4 G 2.5 4 G 4 4 G 6 4 G 10 4 G 16 4 G 25 4 G 35 4 G 50 15.8 x 5.0 19.5 x 5.6 x 6.5 23.6 x 7.2 29.1 x 8.8 35.3 x 10.4 43.6 x 1 48.4 x 14.4 53.5 x 15.9 20 25 40 45 55 60 115 170 0 3 5 810 1 220 1 700 2 500 G = with green / yellow core ➀ Values to be doubled during laying operations Other sizes are also available Ambient temperature o C 5 10 15 20 25 35 40 45 50 55 60 Correction factors 1.27 1.22 1.17 1.12 6 0 0.94 0.87 0.79 0.71 0.61 0.50 53