McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Similar documents
Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

Using the VR448 in place of the Marathon DVR 2000

SPECIFICATION, CONTROLS AND ACCESSORIES

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

SPECIFICATION, CONTROLS AND ACCESSORIES

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

R180. AVRs. Installation and maintenance

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

ADVR-16. Hybrid Universal Analog Digital Voltage Regulator Operation Manual. Self Excited 16 Amp Analog / Digital Voltage Regulator

1. SUMMARY 2. SPECIFICATION 3. WIRING. 3.3 Power Input Voltage Selection. 3.1 A to C: Sensing Input. 3.2 B to C: Power Input

ENGINE GOVERNING SYSTEMS LSM200 SERIES LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

SPECIFICATION, CONTROLS AND ACCESSORIES

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

GX 600 SERIES (AUTOMATIC VOLTAGE REGULATOR)

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

AMC mA Positioner

Generator AutomaticVoltageRegulator OperationManual

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

EA05A. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator 5 Amp AVR For General Generators

WATT TRANSDUCER. Instruction Manual

D I G I T A L V O L T A G E R E G U L A T O R

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

ADVR-2100M. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R448 & R448 V50 A.V.R.

DynaDrive INFORMATION MANUAL SDFP(S)

Rev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.

INSTRUCTION MANUAL FOR TIME OVERCURRENT RELAY BE1-51

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

EVC600C User Manual EVC600C SERIES. EVC600C User Manual. Date Version Note. Version. Page 1 of 6. Ver 1.

EA06 (220V) Generator Automatic Voltage Regulator Operation Manual

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

Current Loop Interface Module M 2025D

DLVP A OPERATOR S MANUAL

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

MODEL KBWD-15 Pulse Width Modulated (PWM)

Ledex Drive Electronics and Coil Suppressors

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

MODEL AT-10 ANALOG TRANSMITTER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2844 PID CONTROLLER WITH FEED FORWARD COMPENSATION

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 A.V.R. R150. Installation and maintenance

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

V S UF OPEN IN 60Hz OE UF SL R120 V N1 U N F1 F2 A.V.R. R120. Installation and maintenance

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

M40FA640A/A - Mark I. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators. (Issued: 04.

Back to the Basics Current Transformer (CT) Testing

PART # mA Positioner

Variable Transformers Product Design & Engineering Data

DISCUSSION OF FUNDAMENTALS

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

BC145 SIGNAL ISOLATOR BOARD

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2547 UNIVERSAL AMPLIFIER MODULE

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

High Frequency SineWave Guardian TM Filter

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

How to Choose Power Supplies

Matrix Power Company MH xxx-va series Specification Document

Generator Speed Controller Model GSC 1

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

SCA-SS (70V, 10A)

HLC-1000 High-limit Humidity Control

WDG 71 - Technical Data Sheet

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

Exercise 1: The DC Ammeter

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

SRVODRV REV7 INSTALLATION NOTES

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

Manual SCA-SS V /02 page 1

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

R438 A.V.R. R438. Installation and maintenance X2 Z1 X1 Z2 E+ E- 0V REQUEST A QUOTE

Linear Power Amplifier Module

TMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual

Protective Relays Digitrip 3000

Load-Trainer Transformer Simulator

Installation, Operation and Maintenance Instructions

Installation and Operation

2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE. Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor.

WDG 12 - Technical Data Sheet

Model Operating Manual

High Frequency Sinewave Guardian TM Filter

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Transcription:

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL 33142 305-634-1511 To avoid of possible personal injury or equipment damage read and understand this manual before installation. (A.V.R) 208 / 380 / 480VAC 50/60HZ OUTPUT: 42VDC 7A DESCRIPTION The voltage regulator is designed for use on 50/60 Hz brushless generators that have internal auxiliary power winding. This regulator includes frequency compensation, over excitation shutdown, a solid-state build-up circuit, and EMI filtering. 1-1 SPECIFICATIONS Refer to Table 1-1 for the electrical specifications of the and to Table 1-2 for the physical specifications. Dc Output Power: Exciter Field Dc Resistance: Ac Power Input: Sensing Input: Voltage Adjust Range: Regulation Accuracy: Paralleling: Table 1-1. Electrical Specifications. 7 Adc at 42 Vdc maximum continuous. 15 Adc at 90 Vdc forcing for 10 seconds. (At 240 Vac supply voltage) 6 Ohms minimum, 105 Ohms maximum. Operating rang 220 Vac to 260 Vac, 1-Phase, 50/60 Hz 200-252 Vac ± 10%, 2-Phase, 50/60 Hz < 1 VA Burden. 180-277 Vac. < 1% No-load to Full-load, Average Sensing. Input for 5 Vac from External C.T./Burden to allow 10% Droop. Response Time: Less than 1.5 cycles for ± 5% change in sensing voltage. Link (T C) and Adjustable Stability to optimize response. EMI Suppression: Internal EMI filter. Frequency compensation: Twice Volts per Hertz (See Paragraph 1-3 for curve). Over-excitation Shutdown: Inverse Time delayed, fixed setting. Trip range from no trip @ 50. Vdc to instantaneous at 100 Vdc. (See Paragraph 1-4 for curve). Disable link terminals (N D) provided for parallel operation. Voltage build-up: Internal provision for automatic build-up from 6 Vac, Soft Start 1

Power Dissipation: Operating Temperature: Storage Temperature: Vibration: Shock: Weight: 20 Watts typically. Table 1-2. Physical Specifications. -20 C (-4 F.) to 60 C. (140 F.) -40 C (-40 F.) to 85 C. (185 F.) Withstands 1.3 G s at 2 to 27 Hz; 0.036 double amplitude at 27 to 52 Hz; and 5 G s at 52 to 1000 Hz. Withstands up to 20 G s in each of three mutually perpendicular axes. 0.68 kg (1.5 lbs). 1-3 FREQUENCY COMPENATION (See Figure 1-1) a. The frequency compensation characteristic of Figure 1-1 used to improve system load pickup performance by restraining voltage recovery until frequency has also started to recover. b. The regulator is shipped from the factory set at a 47 Hz corner frequency for 50 Hz systems. For 60 Hz systems, a 57 Hz corner frequency is achieved by removing the 50-50 external link. GENERATOR OUTPUT(%FROM NORMINAL) 100 90 80 70 60 50 40 30 20 10 0 50 HZ CURVE 60HZ CURVE 5 10 15 20 25 30 35 40 45 50 55 60 65 70 FREQUENCY (HZ) Figure 1-1 Frequency Compensation Curves. 2

1-4 OVER-EXCITATION TIME DELAY If exciter voltage exceeds 52 ± 2 Vdc, the regulator automatically removes the field current, after a time delay. The time delay is inversely proportional to the magnitude of the detected field in over voltage condition up to 95 ± 5 Vdc point. Beyond 95 ± 5 Vdc, the field voltage is removed at a much faster rate. This shutdown function may be disabled for parallel operation by linking terminals N and D together. 1000 100 TIME DELAY(SECONDS) 10 1 0.1 55 60 65 70 75 80 85 90 95 100 105 110 115 FIELD VOLTAGE-Vdc Figure 1-2 Typical Inverse Time Delay Characteristic Curve. 3

2-1 MOUNTING The regulator may be mounted on the generator in any convenient position. Refer to outline drawing Figure 2-1. Figure 2-2 provides the drilling template. NOTE The ground terminal must be bonded either to a metal ground by the mounting screw or by means of a cable to the most suitable earthing point available close to the regulator. GROUND CONNECTION AT THIS MOUNTING HOLE 50 50 VOLT STAB. Q P B A 430mm (17 ) MIN U/F C T D N Figure 2-1 Outlined Diagram. 4

2-2 EXCITER FILELD POWER CIRCUIT a. Connect regulator + wire to the brushless exciter field F+ terminal, and the wire to the field F- terminal. Refer to Figure 2-3. CAUTION The DC resistance of the exciter field must be equal to or greater than 6 ohms and less than 100 ohms. b. If the exciter field resistance is less than 6 ohms, and if the full-load field current does not exceed the maximum continuous current rating of the regulator (7 Adc), a resistor of sufficient wattage must be added in series with the field to bring the total resistance to 6 ohms. AUXILIARY WINDING 50/60HZ GENERATOR U V W + - FIELD GROUND CONNECTION LINK FOR 50HZ EXT. VOLTS ADJUST C.T. (N:1A) N - + 50 4 3 VOLT 50 Q 5A 240 V FUSE STAB. P B V Y A X U U/F C T D N DROOP ADJUST RHEOSTAT (5 OHMS, 10W) LINK IF EXT. VOLTS ADJUST NOT REQUIRED LINK FOR LARGER TIME CONSTANTS LINK TO DISABLE OVER-EXCITATION SHUTDOWN Figure 2-2 Interconnection Diagram, 480 Vac High Y Generator. 5

2-3 POWER INPUT Connect wiring as shown in Figure 2-3. Power for the regulator is derived from the generator auxiliary winding, connected to wires 3 and 4. The operable power input range is 171 264 Vac. 2-4 SENSING INPUT For sensing, wires U and V are connected to the generator phase U and Phase V respectively. Wires X and Y are connected to the opposite ends of the U and V phase coils, or connected together at the Neutral (star) point. 2-5 QUADRATURE DROOP INPUT When paralleling is required, a current transformer (C.T.) and variable burden resistor (rheostat) should be connected to terminals A and B. The ratio of the C.T. and the maximum value of the burden must be chosen so that at maximum current the voltage applied to terminals A and B does not exceed 5 Vac rms. A suitable value of burden would be a rheostat adjustable from 0-5 ohms (10 Watts) for a C.T. with a 1 Aac secondary current at full load. These terminals may either be linked or left open when paralleling is not required. 2-6 FUSES It is recommended that a fuse or fuses with high interruption capability be installed per the interconnection diagram. A suitable fuse type would be Littlefuse TM type 3AG, rated 250 Vac, 6,3 A, SLOBLO. Dimensions are 6.3 mm 32 mm (11/4 M 1/4 M ). NOTE Fuse(s) MUST be installed per interconnection diagram avoid interrupting field current. 2-7 VOLTAGE ADJUST RHEOSTAT (V) a. An internal screwdriver pre-set (V) provides coarse adjustment of generator output voltage. Moving the rheostat clockwise increases voltage. b. The voltage regulator is shipped from the factory with a link across terminals P and Q. If a remote voltage adjusts rheostat is used, the link should be removed and the Rheostat connected to P and Q. A 1 Kilo-Ohm, 0.5W. Potentiometer will provide a fine voltage range adjustment of approximately ± 10% over most of the coarse range of adjustment. See Figure 2-2 interconnection diagram. 6

2-8 V/Hz CORNER FREQUENCY SELECTION For 50 Hz systems, the regulator is pre-set at the factory for a 47 Hz corner frequency, and a link fitted across terminals 50. If operation at 60 Hz is required, this link should be removed; the corner frequency is now set to 57 Hz. do not operate the system at 60 Hz with the 50 Hz link in place. 2-9 OVER-EXCITATION SHUTDOWN a. Over-excitation shutdown is provided by removing output excitation should the regulator s output voltage exceeds 52 ± 2 Vdc for a sufficient time. The inverse-time delay curve is shown in Figure 1-2. For voltage above 95 ± 5 Vdc, there is a second and much shorter inverse time curve. b. After output power is removed, the regulator can be reset by decreasing the input voltage to less than 6 Vac for a minimum of 2 seconds; stopping the prime mover or interrupting the regulator input by means of a reset switch accomplishes this. c. In cases where the generator is operating in a parallel mode, it is sometimes considered undesirable to allow the regulator to shut down, which may cause the generator to be motored. The regulator is provided with terminals N and D, which may be linked together to prevent over-excitation shutdown. Note however that continuous running at output levels greater than the continuous rating may result in eventual regulator failure, and that other means should be employed to protect the system. 7

3-1 GENERAL CAUTION Meggers and high-potential test equipment must not be used. Incorrect use of such equipment could damage the semiconductors used inside this regulator. a. The following operation procedures provide instructions for adjusting the voltage regulator. Symptoms resulting form a faulty regulator and certain generator system problems are included, together with suggested remedies. b. Complete the following steps before proceeding with system start-up. 3-2 PRELIMINARY SET-UP a. Verify that the voltage regulator specifications conform to the generator system requirements. b. Ensure that the regulator links are fitted correctly where required, as follows: (1) If the remote voltage adjust rheostat is not required, ensure terminals P and Q are linked together. (2) If a 57 Hz corner frequency for 60 Hz systems desired, ensure the 50-50 link is removed. If a 47 Hz corner frequency for 50 Hz systems is desired, ensure the 50-50 link is connected. (3) If the system is to be run in parallel, consider whether shutdown of the generator s excitation is acceptable. If not, ensure that the link between terminals N and D is in place. c. Confirm that the voltage regulator is correctly connected to the generator; F+ to field positive, F- to field negative, and terminals 3 and 4 to the auxiliary winding supply. It is vital that the sensing connections are correctly made to all 4 wires U, V, X, and Y. Confirm that the metal ring tag at one mounting hole is bonded to ground via either a metal screw or shout length of cable. d. Install the fuses as per paragraph 2-6. e. Set the regulator and external voltage adjust, if used, as follows: Regulator Volts Adjust V Fully CCW Remote Volts Adjust Centered Stability Adjust S Centered 8

3-3 SYSTEM START-UP a. Perform preliminary set-up, per paragraph 3-2, checking wiring carefully. NOTE All AC voltage readings are to be taken with an RMS average reading voltmeter. b. Start the Prime mover and bring it up to rated speed. RESULT Voltage should build up to less than nominal value. If not, proceed to paragraph 3-4. c. Slowly adjust the regulator voltage adjust V until the generator output voltage reaches the nominal value. Should a low frequency oscillation or hunting be present on the generator output voltage, adjust stability control S to cause this to be damped out. In general, Clockwise increases the stability but in some cases, too far CW may start to reduce stability again, and will invariably slow the response of the generator to load changes. An optimum method of setting is to adjust S slowly CCW until the generator voltage just starts to become unstable, then back off 1/4 turn CW from that position. d. If used, adjust the external voltage adjust rheostat to fine trim the voltage to the exact value desired. RESULT Voltage should now have built up and be stable at the desired value. If voltage does not build to rated value, check that there is no short circuit or excessive load present on the generator lines. If a minimum residual of 6 Vac is not present, perform field flashing per paragraph 3-4. e. Check regulator under normal operating and loading conditions. RESULT Voltage regulation should be better than ± 1.0% no-load to full-load. If regulation is not within this range, check the following: (1) Voltage reduction under loads of cosθ > 0.0 may be due to speed reduction due to loading of the prime mover. This may be causing the frequency compensation (V/Hz) circuit to reduce voltage at a speed that is less than the corner frequency. (2) Replace voltage regulator. 9

3-4 FIELD FLASHING When the regulator is operated with the generator for the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not make build-up voltage, and if the residual voltage is less than 6 Vac, shut down the Prime mover and proceed with the following steps: a. With the Prime-mover at rest and the regulator s field output wires disconnected, apply a DC source (NOT grounded) of not more than 24 Vdc with Positive to F+ and Negative to F-. b. c. Allow approximately 3 seconds before removing the DC source. d. With the voltage regulator disconnected (wires 3 and 4), start the prime mover and measure the residual voltage available at the auxiliary winding. If this voltage is greater than 6 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 6 Vac is measured, repeat field flashing procedure. e. If repeating steps a. and b. does not result in generator voltage build-up, and residual is greater than 6 Vac, replace voltage regulator. 10

R AUXILIARY WINDING OR PMG R T S T S 4 3 V Y X U 380/220 Volts 440/254 Volts 480/277 Volts 4 3 V Y X U 380/220 Volts 440/254 Volts 480/277 Volts R T S 4 3 V Y X U 240/120 DELTA 4 3 V Y X U 208/120 VOLTS INPUT TERMINALS 3 & 4 CAN BE POWERED USING THE GENERATOR ITSELF, AN AUXILIARY WINDING OR A PMG. AUXILIARY WINDING OR PMG THE INPUT OF 3 & 4 MUST BE FROM 60 TO 277 Vac and from 60 to 400 HERTZ See Regulator instructions for more information 4 3 V Y X U 208/120 VOLTS

Use SS47-7M in place of PM100 AVR SS47-7M Original PM100 is used in 1 or 3 phase alternators. If used with 3 phase sensing voltage feed lines into E1, E2, E3 (one E2 lead is null) If used with 1 phase sensing voltage feed lines into E1, E2 and connect jumper between E2,E3 --See Marathon drawing at http://www.marathonelectric.com/generators/connect/pm1 001.pdf To replace the PM100 with the M SS47-7M 1) If 3 phase 200~240V (R,S,T) wiring R-->U, S-->Y, T-->X & V = E1-->U, E2--Y, E3-->X & V 2) If 3 phase 380 ~ 480V The alternator must have neutral point N Interwiring R-->U, T-->V, N-->Y & X = E1-->U, E3-->V, N-->Y & X E2 must be isolated avoid E2 conducting to any metal. 3) PMG is wired to lead 3 and 4 of M Keep original capacitor connected to the 2 wire of PMG output. The capacitor is a big (5~7.5MF 370V) and it is connected to leads 3 & 4 of PM100 The M has no additional lead to connect capacitor therefore move connection to terminal 3 & 4 4) Add one 3A 600V fuse ahead of either lead 3 or 4 wiring Set HF to Max CCW for PM100 Use