Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Similar documents
PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent E8267C/E8257C/E8247C PSG

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent E8267C PSG Vector Signal Generator

Agilent 8902A Measuring Receiver Product Note

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent 83440B/C/D High-Speed Lightwave Converters

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Base Station Installation and Maintenance

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent. E8267C PSG Vector Signal Generator E8257C PSG Analog Signal Generator E8247C PSG CW Signal Generator

Agilent 8761A/B Microwave Switches

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 87415A, 87400A Microwave Amplifiers

Agilent Technologies 3000 Series Oscilloscopes

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 83711B and 83712B Synthesized CW Generators

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 8902A Measuring Receiver

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Meet the new E4438C ESG vector signal generator...

Agilent PNA Microwave Network Analyzers

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Agilent PNA Series RF Network Analyzers

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Product Note E5100A-2

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Advanced Test Equipment Rentals ATEC (2832)

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Advanced Test Equipment Rentals ATEC (2832)

Agilent EPM Series Power Meters

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

6 Tips for Successful Logic Analyzer Probing

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Improving TDR/TDT Measurements Using Normalization Application Note

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

Agilent 8920A RF Communications Test Set Product Overview

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

Agilent PSA Series Spectrum Analyzers E4406A Vector Signal Analyzer GSM with EDGE Measurement Personality

Flexible Signal Conditioning with the Help of the Agilent 81134A Pulse Pattern Generator

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent 4-Port PNA-L Network Analyzers

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent E8247C/E8257C PSG CW and Analog Signal Generators Self Guided Demo. Product Note

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent 83430A Lightwave Digital Source Product Overview

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Agilent E4428C ESG Analog Signal Generator

Data Sheet. Setting Standards

expanding the possibilities

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

Agilent Optimizing Your GSM Network Today and Tomorrow

Agilent 6800 Series AC Power Source/Analyzer

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Agilent E6651A Mobile WiMAX Test Set

Agilent ESG-D Series, Option UN5 Using the ESG-D RF Signal Generator s Multicarrier, Multichannel CDMA Personality for Component Test.

PGT313 Digital Communication Technology. Lab 6. Spectrum Analysis of CDMA Signal

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Agilent CSA Spectrum Analyzer

Agilent 8560 E-Series Spectrum Analyzers

Choosing an Oscilloscope with the Right Bandwidth for your Application

Agilent 8752C RF Vector Network Analyzer

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007

Keysight Technologies N9063A & W9063A Analog Demodulation

8 Hints for Better Spectrum Analysis. Application Note

Agilent 4285A Precision LCR Meter

Agilent PNA Microwave Network Analyzers

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

PGT313 Digital Communication Technology. Lab 3. Quadrature Phase Shift Keying (QPSK) and 8-Phase Shift Keying (8-PSK)

Agilent N7600A Signal Studio for 3GPP W-CDMA with HSDPA/HSUPA

Transcription:

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs Product Note

Table of contents Introduction................................................................3 Block Diagram of I/Q Adjustments on ESG......................................4 Demo......................................................................5 Configuration of Demo...................................................5 Generate 4-QAM Signal on ESG............................................6 Explore the I/Q Output Control Menu...........................................7 Test the Features of the I/Q Output Control Menu............................8 Explore the Mux Menu......................................................13 Explore the I/Q Adjustment Menu.............................................14 Test the Features of the I/Q Adjustment Menu..................................15 Range of I/Q Adjustments and Baseband Outputs...........................17 Ordering Information........................................................18 Related Literature...........................................................19 2

Introduction Many I/Q modulators and ASICs have balanced inputs. The ESG offers balanced outputs expressly for testing such devices. The I and Q outputs on the ESG have corresponding I and Q, which are equal in magnitude, but opposite in polarity. Manufacturers create balanced components to improve the noise rejection of the differential input device. If the source only has a single-ended output (no corresponding I and Q), users have to build external circuits to create differential outputs. What are baseband I/Q signals? In transmitters, the term baseband I/Q refers to signals that are the fundamental products of individual I/Q modulators, before the I and Q component signals are combined, and before up conversion to IF or RF frequencies. Why create signals at baseband? DSP and baseband engineers may need to test the decoding algorithm of the formatspecific demodulation measurements (e.g. CDMA, GSM, W-CDMA) in receivers. Comparisons of measurements made at baseband and measurements of the same device at RF frequencies are especially revealing. Once signal integrity is verified at baseband, impairments can be traced to specific stages of up conversion, amplification, or filtering by RF analysis. The E4438C ESG comes standard with four 50 Ω BNC baseband I/Q outputs located on the rear panel, see Figure 1. The upper two connectors labeled I and Q are the unbalanced outputs. Balanced I/Q outputs Figure 1. Back panel of E4438C ESG showing the balanced I/Q outputs An unbalanced or single ended baseband I or Q signal is available out of the I or Q connector of the ESG. Baseband I/Q test signals may be generated with the unbalanced outputs of either two connectors (I and Q), or with the balanced outputs using four connectors (I, Q, I and Q ). 3

Block Diagram of IQ Adjustments on ESG I/Q inputs from baseband generator Mux key: I/Q out source I/Q output attn. I/Q out gain balance Σ I/Q output filter through or 40 MHz Σ Σ I/Q ext. out I/Q ext. out I/Q ext. input Selectable 50 Ω or 600 Ω input impedance Σ Mux key: I/Q modulator input Σ I/Q modulator pre filter through, 2.1 MHz, 40 MHz I/Q To internal I/Q modulator to be up converted to RF + Ext. 600 Ω input offset adjustment I/Q offset + + Common mode I/Q offset + Differential mode I/Q and I/Q offset I/Q gain balance and source modulator attenuation Figure 2. Block diagram of IQ adjustments. Note: the I/Q offsets are independently adjustable Explanation of Block Diagram There are two I/Q paths in the ESG. One goes from the multiplexer (MUX) to the external I/Q ouputs; this is the upper path in Fig. 2. The second path goes from the MUX to the internal I/Q adjustments, controlled by similar menus. The controls for the upper path are found under the I/Q Output Menu, while the controls for the lower path are found under the I/Q Adjustments Menu. Both menus may be found under the I/Q hardkey. The MUX redirects the possible input sources (baseband generator, or external I/Q inputs) onto the desired path. One source may feed both paths, or each path may be an independent source. 4

Demo On the following pages is a self-guided demo. The demo will familiarize you with the menu placement of each of the adjustments, as well as their physical function. If the equipment is not available, use what equipment you do have to dry lab the experiments. They are sufficiently straight forward that this can still be an effective learning tool. Configuration of demo In the instrument instruction tables, keystrokes that are surrounded by [ ] indicate hard keys located on the front panel, while keystrokes surrounded by { } indicate soft keys located on the display. Measurements were made of the various I/Q features to illustrate the functionality. The equipment used is listed in Table 2 and set-up is shown in Figure 3. Product type Model number Required options ESG Vector Signal Generator E4438C 001 or 002 Baseband generator operating in CUSTOM mode Infinium Oscilloscope 54800 Series (with attached mouse) Table 2: Equipment list and set-up for I/Q measurements on the E4438C ESG Infinium 2 channel oscilloscope Ch. 1 Ch. 2 Ext. trigger Trigger from ESG #1 I Q ESG E4438C with Option 001 Q I Rear Event 1 Q I LF output Figure 3. Equipment setup for measurements made in this document 5

Generate 4-QAM Signal on ESG Generate 4-QAM Signal on ESG [Preset] [Mode] {Custom} {Real-Time I/Q Baseband} {Data} {PN9} {Filter} {Select} {Gaussian} [Return] {Symbol Rate} [250] {ksps} [Return] {Modulation Type} {Select} {QAM} {4 QAM} [Return] {Custom ON} Figure 4. ESG Menu set-up to create a 4 QAM Signal ESG instructions Go to the I/Q Menu Go to the I/Q Output Menu Turn I/Q adjustments on [I/Q] {I/Q Output Control} {I/Q Adjustments ON} [Return] Notice that I-bar is the same magnitude as I and is 180 out of phase with respect to I. 6

Explore I/Q output Control Menu 1 2 3 4 5 6 Figure 5. I/Q menu on the E4438C ESG Description of each feature on the I/Q output adjustments menu This menu controls the upper branch of Figure 2. 1 I/Q output attenuation The I/Q output attenuation can be adjusted from 0 to 40 db. 2 I/Q gain balance This key adjusts the I and Q gain balance. Adding gain (+x db) to the signal decreases the Q component s magnitude, while the I component stays constant. Decreasing the gain (-x db) of the signal, decreases the I component s magnitude, while the Q component stays constant. The range of gain adjustment allowed is -4 db to +4 db. Change the gain balance to adjust out imperfections in I and Q or to introduce calibrated impairments. 3 Common mode I/Q offset This key adjusts the DC offset of both I and Q signals simultaneously. The common mode offset ranges from -4 to +4 Volts. 4 Differential mode I offset This key adjusts the DC offset level of the I and I-bar output signal. I and I-bar cannot be adjusted independently. The differential mode offset ranges from -4 to +4 Volts. 5 Differential mode Q offset This key adjusts the DC offset level of the Q and Q-bar output signal. Q and Q-bar cannot be adjusted independently. The differential mode offset ranges from -4 to +4 Volts. 6 IQ output filter The default setting turns on the 40 MHz I/Q output filter. This may be bypassed by selecting {Through}. In most cases, this setting need not be changed. 7

Test the features of the I/Q output control menu I/Q gain balance measurement Infiniium oscilloscope Autoscale the instrument Set up Oscilloscope: trigger off Event 1 of the ESG Change input impedance for all signals to 50 Ω Display I on channel 1 and Q on channel 2 Change the trigger level to 500 mv I baseband component from the ESG Q baseband component from the ESG Figure 6. Infiniium oscilloscope display of I and Q of ESG 4 QAM signal 8

ESG instructions Use the RPG Knob to vary the I/Q Out Gain Balance and observe how the I and Q waveforms change in magnitude. {I/Q Out Gain Balance} [-4 to 4] db Figure 7. ESG I/Q out gain balance set to +4 db Infiniium scope instructions After viewing the waveforms in normal time domain mode, switch to XY mode, and observe the effect on the shape of the constellation. This requires using a mouse with the oscilloscope. {Measure} {Math/FFT} {verses} {display ON}. Use the hard keys to turn Channel 1 and Channel 2 voltage display OFF. ESG instructions Vary the I/Q Out Gain Balance control on the ESG to see the effect. Figure 8. ESG I/Q out gain balance set to +4 db 9

Common mode I/Q offset measurement Infiniium scope instructions Return to normal time domain mode by unchecking the Math Function display box. Reactivate the Channel 1 and Channel 2 voltage displays using the hard keys. ESG instructions Return the I/Q Out Gain Balance to 0 db. Press the {common mode I/Q offset} key. Use the RPG knob to vary the common mode offset. Observe the effect on the oscilloscope. Figure 9. Display on Infiniium of ESG common mode I/Q offset set to +1.3 V 10

Differential mode offset measurement ESG instructions Return the Common Mode Offset to 0.00 V. Use the RPG Knob to vary the differential mode offset on the Oscilloscope. {Differential Mode I Offset } [-4 to 4] Volts {Differential Mode Q Offset } [-4 to 4] Volts Figure 10. Oscilloscope display of ESG Diff. Mode I Offset set to +1.2 V 11

Infiniium scope instructions Place the scope back into XY mode, and repeat the differential offset adjustment. Figure 11. Display of ESG differential mode I offset set to +1.2 V When finished, return all differential and common mode adjustments to zero on the ESG. 12

Explore the Mux menu Mux control feature description ESG instructions Go to the Mux Menu [Mux] 1 2 3 4 Figure 12. Mux menu on the E4438C ESG 1 Source 1 4 different options for the source to be sent to the IQ modulator and out the RF Output port are available: Off - sends no signal to the modulator Ext 50 Ohm (input through the I/Q inputs on the front panel of the ESG) Ext 600 Ohm (input through the I/Q inputs on the front panel of the ESG) BBG 1 (internal baseband generator from the ESG. Options 001 or 002) 2 Modulator atten The user may adjust the attenuation of the signal before it goes into the I/Q modulator. There are two settings for this key: Auto and manual. Auto defaults to a preset value, depending upon the active personality. Manual is user adjustable. The range is 0 to 40 db. 3 I/Q output atten The output attenuation may be set. The range is 0 to 40 db. This is really a component of the upper path in figure 2, but is repeated in this menu for convenience. 4 I/Q out This sets which signal is being sent to the IQ Output ports. The following are available: OFF - no signal sent to the I/Q outputs 50 Ω - From externally supplied I and Q inputs to the ESG. The output signal is unbalanced outputs (just I and Q) 600 Ω - From externally supplied I and Q inputs to the ESG. The output signal is balanced outputs (I and Q and I-bar and Q-bar). BBG1 (default) - From the ESG s baseband generator. The output signal is balanced outputs (I and Q and I-bar and Q-bar). 13

Figure 13. I/Q external In 600 Ohm offset adjustments Explore the I/Q adjustment menu IQ adjustments feature description The ESG has a separate I/Q adjustments menu that is distinct from the I/Q output control menu. The I/Q adjustments menu controls the lower path in figure 2, going to the I/Q modulator and RF output. Many of the same adjustments that have been described previously are available, but there are two additional adjustments on this menu: External Input impedance, and Quadrature Skew. The E4438C also gives the user the ability to adjust the externally supplied I and Q signal offsets when the selected impedance is 600 Ω The menu structure is shown in Figure 13. External In 600 Ohm I and Q offset Configures the I and Q input offsets. The differential mode offset ranges from 5 to +5 Volts. (This feature is intended to balance out large DC offsets that may be present in some devices.) Quadrature skew Adjusts the phase angle between the I and Q vectors. When the quadrature skew is zero, the phase angle is 90 degrees. Positive skew increases the angle from 90 degrees while negative skew decreases the angle from 90 degrees. The range of values allowed is ±10 degrees with a minimum increment of 0.1 degrees. Skew adjustments are made in the I/Q modulator, and can not be made on signals delivered to the baseband I/Q outputs. 14

Test the features of the I/Q adjustment menu ESG instructions From the Mux menu, change the I/Q output to Ext 600 Ω {I/Q Out} {Ext 600 Ohm) Infiniium oscilloscope Set the oscilloscope back to normal time base mode. Trigger on channel 1, adjust trigger level if necessary. LF Function Generator Set the LF function generator to produce a 10 khz sine wave, 0.5 Vp. Connect it to the I input on the front panel of the ESG. [LF Out] {LF Source} {Function Generator} {LF Frequency} {10 khz} {LF Amplitude} {0.5 Vp} {LF Out) {ON} Figure 14. Sine wave signal on Infiniium Oscilloscope. Notice that the waveform is being generated by the LF function generator, even though CUSTOM is still on and active. This signal is passing through the upper I/Q path in figure 2. 15

Figure 15. Sine wave output offset by Input Offset adjustment ESG instructions From the IQ menu vary the 600 Ω [I/Q] {I/Q Adjustments} {More (1 of 2)} input offsets of the I component. {Ext In 600 Ohm I Offset} Oscilloscope instructions Adjust the trigger level on the oscilloscope as necessary. Conclusion Preset the ESG, when finished, to restore all functions to their default values. 16

Ranges of I/Q adjustments and baseband outputs I/Q adjustments Source Parameter Range I/Q baseband inputs Impedance 50 or 600 Ω I offset [600.only] ± 5 V Q offset [600.only] ± 5 V I/Q baseband outputs I/Q offset adjustment ± 3 V I/Q offset resolution 1 mv I/Q gain balance ± 4 db I/Q attenuation 0 to 40 db I/Q low pass filter 40 MHz, thru RF output I/Q offset adjustment ± 50% I/Q gain balance ± 4 db I/Q attenuation I/Q quad skew [< 3.3 GHz] ± 10 0 to 40 db [> 3.3 GHz] ± 5 I/Q low pass filter 2.1 MHz, 40 MHz, thru I/Q baseband outputs 1 Differential outputs Single ended Frequency range Output voltage into 50 Ω Output impedance I, I, Q, Q I, Q DC to 40 MHz [with sinewave] (1.5 V P-P) [with sinewave] 50 Ω nominal 1. Parentheses denote typical performance 17

Ordering information The differential IQ outputs come standard on the Agilent E4438C ESG Vector Signal Generator. Contact information can be found at http://www.agilent.com/find/assist. 18

Related literature E4438C ESG Vector Signal Generator: Brochure Agilent E4438C ESG Vector Signal Generator Data Sheet Agilent E4438C ESG Vector Signal Generator Configuration Guide Agilent E4438C ESG Vector Signal Generator Infiniium 54800 Series Oscilloscopes: www.agilent.com Brochure Infiniium 54800 Series Oscilloscopes Product Overview Infiniium 54800 Series Oscilloscopes Product Overview See www.agilent.com for more information 5988-3935EN 5988-4039EN 5988-4085EN 5980-2397EN 19

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test and measurement needs Online assistance: www.agilent.com/find/assist Phone or Fax: United States: (tel) 1-800-452-4844 Canada: (tel) 1-877- 894-4414 (fax) (905) 282-6495 China: (tel) 800-810-0189 (fax) 1-0800-650-0121 Europe: (tel) (31 20) 547-2323 (fax) (31 20) 547-2390 Japan: (tel) (81) 426-56-7832 (fax) (81) 426-56-7840 Korea: (tel) (82 2) 2004-5004 (fax) (82 2) 2004-5115 Latin America: (tel) (305) 269-7500 (fax) (305) 269-7599 Taiwan: (tel) 080-004-7866 (fax) (886 2) 2545-6723 Other Asia Pacific Countries: (tel) (65) 375-8100 (fax) (65) 836-0252 Email: tm_asia@agilent.com Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2002 Printed in U.S.A., March 27, 2002 5988-5413EN