Ouput Loop Powered Products Section C

Similar documents
Datasheet ACT20M Signal Isolation and Conversion NEW

Product overview Analogue Signal Conditioning

Assembly. Front view. Parametrization interface. Power Bus

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: R30US4. Remote I/O R30 Series

FC-33, DC SELECTABLE SIGNAL CONDITIONER

2002-ALM USER MANUAL

WAVESERIES Signal converters

Isolators A3/1.

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Temperature transmitter itemp PCP DIN rail TMT 121

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

User manual Firmware V1.0-V1.2 HTB230. In-head transmitter

Industrial Interface The Signal Conditioning People

2002 IS Catalog. Page

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

NEW. Datasheet. ACT20M Signal Isolation and Conversion

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

TSC. Transtech Signal Conditioners. Galvanic Isolation as Standard Full Input Range Field Adjustable 0.1% Accuracy Dual Rail Mounting.

Temperature Transmitters - Head Mounted

P5201 Universal Programmable Transmitters with Galvanic Isolation

User manual V1.0 RTB231 RTB232. RTD transmitter

RTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2.

Temperature Transmitters - DIN Rail Mounted

ADAM 4000/4100 Series

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

FC Series Signal Conditioners

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

itemp HART DIN rail TMT112

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

CONTA-ELECTRONICS. Converter Units

TxBlock-USB Transmitter

Temperature head transmitter itemp PCP TMT 181

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

CALYS 150. Advanced documenting multifunction calibrator thermometer

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

CALYS 50. Field multifunction calibrator for basic use

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.

ISOLATED 4-20 ma TRANSMITTERS

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

CALYS channels High accuracy calibrator

CALYS 150. Advanced documenting multifunction calibrator thermometer

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

MODEL: M1EXT. with Display M1E Series

CALYS 100. Field precision documenting multifunction calibrator

Isolated 4 to 20 ma Transmitters For Demanding Applications Thermocouples, RTD (Pt100) or Ohms, Millivolts, Milliamps, Volts

Miniature Temptran RTD Transmitters

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

CALYS 75. Field documenting multifunction calibrator

Analogue Signal Processing

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

General Specifications

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

High-precision process calibrator Model CED7000

CALYS 150. Advanced documenting multifunction calibrator thermometer

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

Process displays For standard signals, temperature, resistance measurement

MINI MCR-SL-UI-I-LP-NC

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

MODEL: W2TS. Mini-MW Series

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Isolators & converters

4-20mA, 0-10V and general process measuring bargraph displays

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

Additel 875 Series Dry Well Calibrators

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Temperature Transmitter ZTT series

MTL4600 range. Isolating interfaces. Technical data MTL intrinsic safety solutions

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Temperature measurement TMD 832 head transmitter

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

ALM42 ALM46 ALM48 ALM43

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PR product range - links to order details and block diagrams

Bulletin 931 Signal Conditioners Technical Data

DRG-SC Series Signal Conditioners

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transmitters/Signal Conditioners

VersaPoint I/O Module

OPTITEMP TT 20 Technical Datasheet

Transcription:

Ouput Loop Powered Products Section C An output loop powered (or signal powered) isolator derives its power from the voltage drop across the device's current loop output. Because they require no separate power supply wires they have a low installed cost. www.weidmüller.com.au

Output Loop Powered Products Output Loop Powered solators Output loop powered (or 2-Wire) isolators gained their name because the power for their operation is carried on the same pair of wires as the output signal they control. A typical loop consists of a regulated dc power supply, the two-wire transmitter and a receiving device all connected in series as shown. The output signal powers the electronics of the transmitter. The input is filtered and conditioned and then passed across an input to output isolation barrier. The demodulated signal varies the output in proportion to the measurement. The input side can be analogue based with fixed input, or microprocessor based such as the TXPlus, which offers greater flexibility in handling many different input types in a standard off the shelf unit. Typical connection for Loop Powered Transmitter 24Vdc Tx 2-wire Device V ma nput Loop Powered Output Load Receiving Device Output Loop powered isolators require from 6V minimum to operate correctly. The maximum load in the output loop can be calculated using ohm's law as follows: R (max) = (Vs-Vd)/0.02Ω, where Vs is the dc loop supply voltage and Vd is the voltage drop across the inputs of the isolator. Output loop powered isolators accept passive inputs and or active inputs from two wire transmitters in the field. Output loop powered solators are commonly used for isolating and converting inputs from the field to the control or monitoring system. These could include Thermocouples, RTD s, Resistance, Potentiometers, ma, or Volts and now 2-wire transmitters with the ACT20M models available in single and dual channel models. Care should also be taken to ensure that an output loop powered isolator has sufficient power to drive the required load. Failure to do so will not allow the unit to reach full output, resulting in false readings and preventing the activation of high alarms. 0V C.2

Universal nput 1 J/V/ 24 V 6 3 2 4 5 Universal Loop Powered Signal solator/converter TXPlus Weidmüller s TXPlus is a PC configurable 2 wire isolator. The TXPlus is powered from the output loop and boasts a fully programmable input (selectable for Thermocouples, RTD s, mv, V, ma, resistance or potentiometer. The output can be configured for direct or reverse acting or custom curve. Software for the TXPlus is shipped with the CBX100USB adaptor (for programming via PC USB port) or you can order a factory customised unit using the variable number. Although the TXPlus is output loop powered, it can drive a 600Ω output load @ 24Vdc supply. nput/output isolation is 2kV while housed in a 12.5mm wide case. Configurable input to most process signals 10-40Vdc loop powered supply Simple free PC software Slim 12.5mm housing Use the TXPlus to: solate instrument runs between the field and the control system Convert most process signals to 2-wire output Linearise non linear signals from tanks or flow sensors Convert current source signals to Loop Powered CBX100USB nterface kit A CBX100USB provides an isolated USB connection from a PC to provide data transfer to the TXPlus and Wave TTA models. T-Set programming software allows parameter upload or download, live viewing of process value, and data logging. nputs Thermocouple RTD Milliamp Voltage Millivolt Universal B, C, E, J, K, L, N, R, S, T, W3, W5 or User Defined Pt100, Pt200, Ni120, Cu100 (2, 3 or 4-wire mode) -10mA to 20mA into 40Ω (min. span 1mA) -5V to 10V into 2MΩ (min. span 0.5V) -100mV to 200mV into 2MΩ (min. span 4mV) Resistance 0 to 10kΩ (min. span 10Ω) Potentiometer Outputs Output Type Power Supply Power Supply Type Voltage Drop Across Unit Performance 1.2kΩ to 500kΩ (end-to-end resistance) (Output Loop Powered) Output Loop Powered 10V Linearity Typically ±0.1% CJC Lead Length Compensation Step Response (10%-90%) Operating Temperature Better than ±1.0 C < 0.002Ω per Ω of cable resistance Typically 400ms -10 to 70 C Dimensions (mm) 75.5 x 12.5 x 119 Terminals Conductor Type Screw Type 12-28AWG wire Type Order No. TXPlus 7940016563 TXPlus Variable (Specify input type and range) 8944980000 CBX100USB and Software 7940025031 C.3

ACT20M solators for Output Loop Powered Devices 2-wire Transmitter Tx - nput ch. 1 Output ch. 1-24VDC 2-wire Transmitter Tx - nput ch. 2 Output ch. 2-24VDC Single and Dual Channel, Output loop Powered, solator solators for Output Loop Powered Devices The ACT20M OLP provides an isolated field supply for an Active input from a 2 wire transmitter, and repeats this value on the output. This model will insert directly into an existing 2 wire loop and provide isolation with no wiring changes. Extremely compact design (6.1mm wide) solate 2 wire Transmitters Output Loop Powered Available in single and dual channel versions Complete solation (nput to Output) -25 C to 70 C operating temperature DN Rail mounting Accuracy < 0.1% of end value Galvanic solation Passive solator nput/output 0(4)...20 ma/0(4)...20 ma V Drop Typically 2.5V Output Load 600Ω Channels Single/Dual Mounting rail TS 35 Temperature coefficient 50 ppm/k of final value Type of Connection Screw Connection ECEx ratings Ex na C T4 Gc Length x Width x Height 114.3 x 6.1 x 112.5 mm Use ACT20M C-CO-OLP solators for: solating 2-wire (Output Loop Powered) devices Prevention of ground loops and reduction of common mode noise ACT20M C-CO-OLP-S Single Channel, Screw Connection 1176040000 ACT20M 2C-2CO-OLP-S Dual Channel, Screw Connection 1176050000 C.4

Current/Voltage solator Single Channel, Output Loop Powered, solator Output Loop Powered solators The Wave Series output powered (2-wire) isolator draws its power from the output signal current loop (). t has switch selectable input range and can be configured with two response times to suit your application. Output Loop Powered Switch Selectable nput Current /Voltage Ranges Switch Selectable response time Complete solation (nput to Output) 0 C to 55 C operating temperature DN Rail mounting nputs nput Ranges Max. Voltage / Current Analogue Output Output Type Output Range Output Drive Performance Accuracy Step Response DP Switch Selectable Current/Voltage Range 0-20mA into 51Ω into 51Ω 0-5V into 210kΩ 0-10V into 430kΩ 30Vdc / 40mA Output Loop Powered (12Vdc to 30Vdc) 600Ω @ 24Vdc Operating Temperature 0 to 55 C Better than 0.2% of Span Switch Selectable (80ms or 50ms) Dimensions (mm) 92.4 x 17.5.0 x 112.4 Terminals Conductor Clamping Range Screw Type 0.5mm ² to 2.5mm² Use output loop powered isolators for: solation of ma or Volt signals into Conversion and isolation of sourced loops to control systems configured for loop powered inputs Reduction of power supply wiring WAS5 OLP Single Channel, Screw Connection 8543720000 C.5

Dual Channel Signal Splitter/solator 1 2 in/vin 0 V V/ 24 V 5 6 3 4 in/vin 0 V V/ 24 V 7 8 Dual Output Loop Powered solator 1 2 in/v in V/ 24 V 5 6 3 4 0 V V/ 24 V 7 8 Using the TW-2 as a signal splitter TW-2 The TW-2 has two, independent, output loop powered isolators for loops in one box. Typically TW-2 isolators are used as: solators - to eliminate faulty readings caused by ground loops, electrical interference and motor noise. Signal Splitters - to produce two independent isolated outputs from one input. Use the TW-2 for this application by connecting the two inputs in series. The outputs can go to completely separate devices such as control systems, PLCs, indicators, controllers and data loggers. Signal Repeaters - to boost signals for increased transmission distance or allow additional devices to be connected to the loop. Technical data Channels Analogue Output Output load Power supply Adjustments Linearity solation Dual DN Rail mount /0-10V (as ordered) Single/Dual (as ordered) (Fixed) 600Ω Load @ 24Vdc Output Loop Powered 20-turn potentiometers Typically ±0.1% of span 1.5kVrms for 60s (AC & DC) Output Loop Powered Single and Dual Channel versions Current or Voltage inputs ndependent Zero and Span controls for each channel 600Ω output drive capability at 24Vdc No internal adjustments needed Dual DN rail mount housing Plug-in, screw type, terminal blocks Use the TW-2 for: Reduction of rail space for 2 loops Link inputs for 1in/2out option for adding second output Add 250Ω to second output for 1-5V monitoring point TW-2 0-10V TW-2 with 0-10V nputs 7940012011 TW-2 TW-2 with nputs 7940010171 C.6

Splitter/solator Output Loop Powered, Splitter and solator Output Loop Powered Splitter The Wave Series Output Loop Powered Signal Splitter produces two independent isolated outputs from one input. The outputs can go to completely seperate devices such as control systems, PLCs, indicators, controllers and data loggers. Both outputs are loop powered. Very low power consumption Output Loop Powered nput range selected by DP switch Complete solation 0 C to 55 C operating temperature DN Rail mounting nputs Maximum Current 40mA Voltage drop 3.8V Analogue Output Output Type Dual Output Loop Powered (12Vdc to 30Vdc) Output Range Output Load 600Ω @ 24Vdc Output Voltage Drop 12V Performance Accuracy Better than 0.2% of Span Step Response 20ms solation 4kV Operating Temperature 0 C to 55 C Dimensions (mm) 92.4 x 17.5 x 112.4 Terminals Screw Type Conductor Clamping Range 0.5mm ² to 2.5mm² Use Output Loop powered splitters for: that require a second signal from a loop Feeding a duplicate signal to monitoring system, e.g. DCS/PLC Providing a 0-5V test point on a loop across a 250Ω resistor WAS5 CCC 2OLP Output Loop Powered Signal Splitter / solator 8581160000 C.7

MCZ Pt100 Signal Converters MCZ Pt100/3 CLP Pt100 Signal Converters The MCZ Pt100/3 CLP is an Output Loop Powered Signal Converter for two and three wire Pt100 Temperature Sensors. Pt100 sensor construction provides natural isolation from the process. A version is also avaialble with a built-in sensor for enclosure temperature monitoring applications with an overall accuracy of ±0.5 C. Accuracy Typically 0.2% Linearised to Temperature Automatic Lead Length Compensation Operating Temperature 0-50 C Fast response 10ms Output Type Output Drive Step response time Supply voltage max. Temperature coefficient max. Linearised Accuracy solation Pt100 Temperature Sensor with automatic lead length compensation current loop 600Ω 10ms 30 V/min. 9 V (20 ma x RL) ±250 ppm/k To measure temperature Typical 0.2%, max. 0.5% of span None Operating Temperature 0 C to 50 C Mounting rail TS 35 Dimensions (mm) 91 x 6 x 63.2 Terminals Tension Clamp style connectors Conductor Clamping Range 0.5mm ² to 1.5mm ² Use the MCZ Pt100/3 CLP for: Conversion of temperature sensor to for noise immunity cable cost reduction over sensor cable Also available with built-in Pt100 sensor for enclosure temperature monitoring (0-50 C) MCZ Pt100/3 CLP 0-100 C Output Loop Powered Pt100 Converter 0-100 C 8425720000 MCZ Pt100/3 CLP 0-120 C Output Loop Powered Pt100 Converter 0-120 C 8483680000 MCZ Pt100/3 CLP 0-150 C Output Loop Powered Pt100 Converter 0-150 C 8604420000 MCZ Pt100/3 CLP 0-200 C Output Loop Powered Pt100 Converter 0-200 C 8473010000 MCZ Pt100/3 CLP 0-300 C Output Loop Powered Pt100 Converter 0-300 C 8473020000 MCZ Pt100/3 CLP -50 C to 150 C Output Loop Powered Pt100 Converter -50 C to 150 C 8473000000 MCZ Pt100/3 CLP -40 C to 100 C Output Loop Powered Pt100 Converter -40 C to 100 C 8604430000 MCZ Pt100 / 0-100 C /Built-in Pt100 New! Temperature Sensing Teminal Block 0-100 C 7940047724 APMCZ 1.5 End Plate for MCZ housing 8389030000 C.8

TXPlusH Head Mount, Universal nput Converter/solator 1 J/V/ 24 V 6 3 2 4 5 Universal Loop Powered Signal solator/converter TXPlusH The TXPlusH is a truly universal, compact, loop powered, isolated, signal conditioner in head mount housing. You can program it to suit most input signals. t will measure, convert, linearise, filter, and isolate the signal and provide you with an industry standard output. Universal nput Converts, filters and and isolates most common signals and sensor types Loop powered PC Programmable Automatic CJC for thermocouple inputs Automatic lead length compensation for RTD inputs Sensor burnout detection Preset and user-defined linearisation Fully isolated Head mount Use the TXPlusH for: mproved signal over long runs Low cost temperature conversion Valve position monitoring - Potentiometer conversion RTD Conversion in large sensor head DN Rail RTD converter CBX100USB nterface kit A CBX100USB provides an isolated USB connection from a PC to provide data transfer to the TXPlusH, TXPlus and Wave TTA models. T-Set programming software allows parameter upload or download, live viewing of process value, and data logging. nputs Universal Thermocouple B, C, E, J, K, L, N, R, S, T, W3, W5 or usr Defined RTD Pt100, Pt200, Ni120, Cu100 (2,3 or 4-wire mode) Milliamp -10mA to 20mA into 40Ω (min.span 1mA) Voltage -5V to 10V into 2MΩ (min.span 0.5V) Millivolt -100mV to 200mV 2MΩ (min.span 4mV) Resistance 0 to 10kΩ (min.span 10Ω) Potentiometer 1.2kΩ to 500kΩ (end-to-end resistance) Outputs Output type (Output Loop Powered) Power Supply Power Supply Type Output Loop Powered Voltage Drop Across Unit 10V Performance Linearity Typically ±0.1% CJC Better than ±1.0 C Lead Length Compensation < 0.002Ω per Ω of cable resistance Step Response 400ms Typically Operating Temperature -10 to 70 C Type Head mount hockey puck type Dimensions (mm) 44.0 x 25mm Terminals Screw Type Conductor Type 12-28AWG Wire TXPlusH// TXPlusH / 7940010160 TXPlusH TXPlusH Variable (Specify input type and range) 7940083981 CBX100USB and Software Communications and solation for PC USB Port 7940025031 Adaptor to suit CBX100UBB CBX100 USB head mount adaptor 7940029545 C.9

Head Mount Temperature Sensor Converters 24 V NTX/H/RTD Technical data nput Range Channels Analogue Output Power supply Adjustments Linearity Fully encapsulated, Hockey puck style design Pt100 Fixed (as Ordered) Single Output Loop Powered Front panel, multi-turn potentiometers Typically ±0.1% of span NTX/H Series The Mann Series NTX/H/RTD are head mount, loop powered, transmitter suitable for measuring temperatures. nputs are fixed range (with wide adjustment) from Pt 100 resistive temperature detectors (in 2-wire or 3-wire mode). The transmitters are non-isolated since RTD construction normally provides isolation from the process. The fully encapsulated, hockey puck style design mounts directly into a standard temperature probe head. This reduces cabling costs as long runs of expensive RTD (3-wire) and thermocouple extension cables are not required. n addition the low level measurement signals are converted to a high level signal more suitable for long distance transmission. Use the NTX/H Series for: Conversion of temperature sensor at sensor head to for noise immunity cable cost reduction over sensor cable Output Loop Powered Linearised to temperature Accurate, stable and repeatable True lead length compensation Mounts directly in a standard temperature probe head Loop operating LED indication Fully encapsulated, hockey puck style design Ordering nformation Type Type Order No. NTX/H/RTD 100 NTX/H/RTD/0-100 C 7940010161 NTX/H/RTD 150 NTX/H/RTD/0-150 C 7940011771 NTX/H/RTD 200 NTX/H/RTD/0-200 C 7940011383 Other ranges available on request. C.10

Head Mount RTD Sensor Converters 5 4 3 2 6 1 24 V Head mount RTD Transmitter Head Mount RTD Transmitter The head mount RTD transmitter fits in a standard probe head and converts the measurement from an RTD to a standard analogue signal suitable for sending long distances. t is output loop powered so it only requires two wires for both the power and signal connection. Suits most RTD Sensor Types Output Loop Powered Mounts in large temperature probe head Accuracy 0.05% from reading 0.1 C Connects to sensor using three or four wire connection Wide operating temperature range (-40 C to 85 C) PC Programmable via USB port and HTB-Prog interface box Use the HTB230 for: mproved signal over long runs Low cost temperature conversion Valve position monitoring - Potentiometer conversion RTD Conversion in large sensor head DN Rail RTD converter HTB-PROG USB Programmer nputs Type 2, 3 or 4-wire RTD or resistance RTD Sensors Pt100, Ni100, Cu10 Resistance range 0 to 2kΩ Output Type Output Loop Powered, Supply Voltage 6.5 to 30Vdc Drop across outputs 6.5V Sensor fault 23mA (upscale selected) or 3.5mA (downscale selected) Performance Accuracy ±0.05% of span ±0.1 C Thermal Drift ±1μA per C Operating Temperature -40 C to 85 C Type Head mount, hockey puck type Dimensions 24 high x 60 mm diameter Fixing Two captive M4 screws (44mm apart) HTB230 Head mount RTD transmitter 7940084187 HTB-PROG Configuring Hardware 7940084188 HTB300 DN Bracket DN Rail mounting bracket 7940084991 MekuWin Configuring Software (Free) 7940084992 C.11

Wall/Ceiling Mount, RTD Temperature Sensor Converters 75mm 24 V ENVROTRAN 115mm ENXHRTD 30mm ENXRTD ENXHRTD The ENXHRTD is a cost effective, wall mounted temperature transmitter designed to blend into any environment from factory warehouses to hotel rooms. t mounts on a standard electrical wall plate. ts output is either a proportional signal or direct 3-wire Pt100 RTD connection. As a loop powered device, the ENXHRTD uses only two wires and the signal eliminates errors caused by resistance at connections and over the length of the wiring run. The internal electronics of the Envirotran are fully encapsulated and safe to install in any enviroment. Technical data nput Range Channels Power supply Adjustments Linearity Wall mount Pt100 or Fixed (as Ordered) Single Output Loop Powered Multi-turn potentiometers Typically ±0.1% of span Mounts directly on any flat wall or ceiling Highly reliable, fully encapsulated design Low temperature drift Cost effective Loop Powered with Loop operating LED indication Fully factory calibrated Output linearised to temperature Use the ENXHRTD for: Air-conditioning temperature sensor Environmental temperature monitoring Cabinet temperature monitoring ENXRTD Pt100 7940011512 ENXHRTD 60 Output for 0-60 C 7940015211 ENXHRTD 75 Output for 0-75 C 7940012035 ENXHRTD 100 Output for 0-100 C 7940011673 C.12

AC Current Monitoring 1 NC 2 3 N Out NC Out - 7 8 9 WAS1 CMA LP 1/5/10A ac Wave Series current monitoring The WAS1 CMA LP is an output loop powered AC current transmitter with switch selectable input range of 1A, 5A and 10A. Units provide 4kV isolation with 6kV impulse protection and can handle temporary overcurrents up to 100A. Switch selectable input ranges output Slim 22.5mm housing nputs Sinusoidal AC Current (50-60Hz) Measurement Method Via direct connection to nternal CT Current Range Switch selectable 1A, 5A or 10A Max. Current 100A for 1s Outputs Output Type Output Loop Powered Output Range Power Supply Power Supply Type Output Loop Powered Voltage 13-30Vdc Performance Accuracy 0.5% Full Scale Step Response 700msTypically Operating Temperature 0-50 C solation nput/output isolation 4kV mpulse withstand 6kV Dimensions 72.0mm x 22.5mm x 92.4mm Terminals Screw Type rated 2.5A Conductor Diameter 0.5mm² to 2.5mm² For Current Transformers see page K.1 Use nput Loop Powered solators for: Monitoring of mains current Measuring motor current consumption Type nput Sensor nput Range AC/DC Output WAS1 CMA LP 1/5/10A nbuilt CT 0-1A / 0-5A / 0-10A 50-60Hz AC Output Loop Powered 8528650000 C.13