A. Submit properly identified manufacturer's literature before starting work.

Similar documents
SECTION IDENTIFYING DEVICES

*********************************************************************************************************

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION IDENTIFYING DEVICES

SECTION SIGNAGE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

INTERIOR SIGNAGE MANUAL

SECTION INTERIOR SIGNAGE

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

A. Submit manufacturer's technical data and installation for each type of sign required.

SECTION PRE-MANUFACTURED CABINETS

A. Interior and exterior non-illuminated tactile building signs including Braille.

A. It is preferred that all submittals to be submitted electronically in PDF format.

SECTION INTERIOR SIGNAGE

Uniform Sign Plan (USP) MacGregor Village 86-USP-003

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Summary of Modifications/Changes in this Update

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

1. ASME A Scheme for the Identification of Piping Systems.

Architectural Aluminum Frames

ETCHED PLAQUES by Matthews International

Americans with Disabilities Act (ADA) Federal Guidelines

TOILET ROOM ACCESSORIES Concrete Unit Masonry Carpentry Ceramic Tile Solid Plastic Toilet Partition.

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

BUILDING SIGN PROGRAM JULY 2012

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

A. Product Data: For each electrical identification product indicated.

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

***************************************************************************************************************

B. Shop Drawings: For residential casework. Include plans. elevations, details, and attachments to other work.

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction

WOOD WOOD

SECTION MECHANICAL IDENTIFICATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Design and Construction Standards SECTION ATHLETIC LOCKERS

Page 1. FIG. #1 - Shower Door Assembly SHOWER & BATH ENCLOSURES BUILT TO LAST A LIFETIME HANDLE ASSEMBLIES REMOVED FOR CLARITY.

SECTION Display Case Door Series 1301-CM

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION ELECTRICAL IDENTIFICATION

CHAPTER 5 ARCHITECTURE

SECTION ARCHITECTURAL WOODWORK

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

PLANNED SIGN PROGRAM CHECKLIST

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

Architectural Door & Cabinet Door

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION ARCHITECTURAL WOOD CASEWORK

Installation Manual for Metal Toilet Partitions Elite & Elite Plus Series

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

SECTION MECHANICAL IDENTIFICATION

PRODUCT DATA CATALOG

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

SECTION CUSTOM FABRICATED EQUIPMENT

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

SECTION MANUFACTURED CASEWORK

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

SECTION ARCHITECTURAL WOODWORK. B. Related Sections: 1. Section Paints and Coatings: Field applied painted finishes.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Product Guide Specification

B. American Society for Testing and Materials (ASTM):

ADDENDUM TO THE CONTRACT. for the GLACIER FIRE STATION KITCHEN AND CLASSROOM RENOVATION. Contract No. E16-181

***************************************************************************************************************

BUILDING SIGN PROGRAM SEPTEMBER 2016

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

4. Metal roof jacks at penetrations and attachments

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

Architectural Door & Cabinet Hardware

C-Series & S-Series Classic Frame with Transom (Single or Pair)

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION PLAQUE, SERVICE AWARD PUBLICATION

SECTION CUSTOM CASEWORK

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Student Services & Classroom Addition

Series 1600 WeatherGuard Dock Enclosure

SECTION MECHANICAL IDENTIFICATION

INSTALLATION INSTRUCTIONS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

C. Installation shall be by experienced carpenters. Coordinate with plumbing and electrical contractors.

Thermally Broken Framing and Door Installation

INSTALLATION INSTRUCTIONS

Piping & Equipment Identification

Transcription:

SECTION 10400 IDENTIFYING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Labor and materials required for installation of plaque, school name and address numbers, directional signage, signage for classrooms, buildings, traffic control, parking, emergency exits, fire system and warning information, elevators, toilet rooms, and capacity signs and obstruction warnings. 1.02 SUBMITTALS A. Submit properly identified manufacturer's literature before starting work. B. Shop Drawings: 1. Submit a full scale shop drawing or "rub" of plaque, for approval, before casting. 2. Submit a shop drawing of school name and address numbers for approval. C. A list of laminated signs for room and area numbers and names will be furnished by the Board. D. Samples: Submit 3 samples of laminated signs to A/E for approval before fabrication. Approved samples may be used in work. PART 2 PRODUCTS 2.01 MATERIALS A. Dedication Plaque: (Aluminum) (Bronze), as manufactured by A.R.K. Ramos or Sheidow Bronze Corp. 1. Size: 14 inches x 20 inches high. 2. Text: As indicated, with modern block letters. 3. Finish: Stippled background with polished letters. 4. Manufacturer's approved fasteners for concealed mounting. B. School Name and Numbers for Address, Cast Aluminum Letters: Project No. SPECIFICATION GUIDELINES 10400-1

1. Material: Cast aluminum, alloy 214. 2. Style: Helvetica Medium. 3. Finish: Satin aluminum with clear lacquer spray coating. 4. Sizes: a. 18" to 24" letters, 1/4" thick, for school name, approximately required. b. 10" numbers, 1/4" thick, for address, approximately (3) (4) (5) required. 5. Manufacturers: a. A.R.K. Ramos. b. Sheidow Bronze Corp. C. Raised Image Laminated Signs: 1. Comply with Americans with Disabilities Act and Accessibility Guidelines (ADA) and State Requirements for Educational Facilities (SREF). 2. 1/8" thick minimum plastic laminated material with 0.008" thick minimum plastic face layer, of sizes, quantity, colors, with raised numbers, letters, Braille, or symbols as indicated on Drawings or as specified in this section for accessible signage, room identification, and life safety signage. Tape applied or glued raised text, braille, or symbols are not allowed. a. Manufacturers: 1) Andco Industries Corp., Greensboro, NC. 2) ASE (Architectural Signs and Engraving) Inc., Orofino, ID. 3) Best Sign Systems, Montrose, CO. 4) Industrial Frames, Inc., Miami, FL. 5) Mohawk, Schenectady, NY. 3. 1/32" Raised Images: a. Letters: Size, according to Drawings or 1 inch high, Helvetica medium. b. Numbers: Size according to Drawings or 1 inch high Helvetica medium. c. Braille: Grade II. Adhered labels are not allowed. d. Symbols: Use Braille, letters, numbers, and Group One symbols sized per requirements of standard spacing. Project No. SPECIFICATION GUIDELINES 10400-2

4. Sizes: a. Accessible Signage, Room Identification, and Life Safety Signage: 1-3/4" wide by length required or as custom designed. b. Symbol Signage: 9 inches x 9 inches or as custom designed. c. Directional Signage: 9 inches x 9 inches or as custom designed. 5. Mountings: a. Mount using tamperproof screws, shields, and double face tape or adhesives to hold signage in place. 6. Colors: a. Black background or color as specified by A/E for sign face and Braille and white raised text or symbols for the following: 1) Assembly and Non-instructional Spaces: a) Interior/exterior signage for room names and room numbers, as scheduled on drawings. b) Minimum one room name/number/braille sign per each main entrance door. c) Room descriptions average 10 letters. d) Provide room numbers and Braille only at secondary or exit doors of these spaces. 2) Classrooms and Labs: a) Interior/exterior signage for room names and room numbers, as scheduled on drawings. b) Minimum one room name/room number/braille sign per each entrance. c) Provide room numbers and Braille only at secondary or exit doors of these spaces. 3) Toilets/restrooms: One sign minimum at each entrance. 4) Specialty Use Rooms: One name/number sign minimum at each entrance door. 5) Specialty description as required or as indicated on drawings. 6) Accessible egress signage. 7) Directional signage at the follow locations as required or as indicated on drawings: Project No. SPECIFICATION GUIDELINES 10400-3

a) At building entrances indicating to administration area and with "ALL VISITORS TO REPORT TO ADMINISTRATION". b) At corridors indicating direction to specific room numbers or subject areas. ****** ***** **** *** ** * ** *** **** ***** ****** NOTE TO SPECIFIER: Provide one directional sign for every 5,000 square fee of project including necessary accessories. ****** ***** **** *** ** * ** *** **** ***** ****** c) Number of signs. b. Red background for sign face and Braille, with white raised text or symbols for the following: 1) "FIRE EXTINGUISHER INSIDE" at each main door of a room containing a fire extinguisher. 2) "FIRE ALARM PULL STATION INSIDE" at each main door of a room containing a pull station. 3) "EMERGENCY EGRESS - KEEP AREA CLEAR" at emergency egress openings and not readily identifiable secondary egress doors. 4) "EMERGENCY RESCUE - KEEP AREA CLEAR" at emergency rescue openings. 5) "ELEVATOR EMERGENCY" adjacent to exterior alarm bell. 6) "STORAGE NOT PERMITTED" at mechanical, electrical, and kiln rooms. 7) "IN CASE OF FIRE DO NOT USE ELEVATOR. USE STAIRWAYS" at elevator hall call stations. 8) Occupancy load signs for spaces with 50 or more occupants. 9) "NO SMOKING" as indicated on Drawings and specified in this section. D. Evacuation Signage. 1. Metal frames with safety glazing to receive an 8-1/2" x 11" floor plan, provided by the A/E, showing the primary and secondary evacuation routes from each space with an occupant load of 6 or more and not having a door opening directly to the exterior. 2. Number of Frames. 3. Frame Color. E. Traffic Signage. 1. Comply with Florida Department of Transportation requirements for signage as indicated on Drawings. Project No. SPECIFICATION GUIDELINES 10400-4

2. The use of aluminum components is not allowed. F. Obstruction Warnings: 1. Comply with SREF life safety potential hazards. 2. Padding with Colored Striping for TV Brackets Below 6'8": TV Mount Safety Bumpers by Universal Seating Co., Jacksonville, FL. PART 3 EXECUTION 3.01 INSPECTION A. Do not proceed with the work of this section until conditions detrimental to the proper and timely completion of the work have been corrected in an acceptable manner. 3.02 INSTALLATION A. Erect plaque to wall with concealed mounting where directed by A/E. B. Mount school name and address cast aluminum letters where indicated by A/E via threaded pins in drilled holes with mastic cement, and 1/2" diameter aluminum tube spacers. C. Mounting of Laminate Plastic Signs: 1. Mount laminated signs with centerlines at 3'-6" and 5'- 0" above finish floor according to ADA, SREF, and as indicated on drawings with tamperproof fasteners and predrilled holes and double face tape or adhesives. 2. Signage shall be left clean and without any rough edges. Signage shall be left without any defects concerning installation from plumb and level, concerning material quality or any other discrepancy in mounting. D. Obstruction Warnings: Apply padding to exposed lower edges and corners with screws at 6 inches on center and double stick tape. Use rabbeted joints at corners of padding strips. Cover exposed padding with warning tape. END OF SECTION Project No. SPECIFICATION GUIDELINES 10400-5