For doors up to and including standard door sizes

Similar documents
80/2 & 80/3 Telescopic system

HENDERSON. Securefold Bottom Rolling. Fitting Instructions For Bottom Rolling External Doors with Morticed hinges SYSTEM CAPACITY.

HENDERSON. Securefold R-Loc Non-Mortice 100kg. Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

HIDEAWAY SERIES POCKET DOOR SYSTEM ASSEMBLY INSTRUCTIONS

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

MODUS 770 AND MODUS 1280 (FLAT PACK) OPERATIONAL, ASSEMBLY & FIXING INSTRUCTION LEAFLET

INSTALLATION INSTRUCTIONS

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

1 PREPARE HEADER AND ROUGH OPENING

SINGLE TRACK BYPASS (patent pending) barn door hardware

VISAGE SCREEN SYSTEM - FOUR SIDED (FLAT PACK) OPERATIONAL, ASSEMBLY & FIXING INSTRUCTION LEAFLET

LOWLINE SINGLE FOLD DOWN WALL BEDS

Decmber Residential Sliding Gear. Design in Motion

Heavy Duty I-Beam Trolley

SIDE FOLDING POST ADJUSTMENTS

Bathroom Installation Guide

Heavy-Duty Bypass Track System

C-Series & S-Series Classic Frame with Transom (Single or Pair)

Box Track INSTALLATION INSTRUCTIONS

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

Assembly guide. Before you start...check the pack and make sure all the components and fixings are included see. Tools required (Not Supplied)

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

INSTALLATION GUIDE. 1. Overview. 2. Measuring. 3. Tools & fixings you will need B C. Opening Width. Opening Height

How To Measure Your Finished Opening

Installation Instructions

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

Preference Slimline 5536 Utility Console

INSTALLATION INSTRUCTIONS

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

ROOM FOLD SLIDING FOLDING INTERNAL DOORSET FITTING & FIXING GUIDELINES

Vanity Installation Instructions

Therma-Tru Door Gallery Setup Instructions Swing Unit with Hardware Kit - Hardware Part # MADGSWU15 (Swing Unit) Part # MADGHKSU10 (Hardware Kit)

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

Arriva. Concealed frame doorsets. Installation instructions

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

LAN Locker Adjustable Shelves

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

M10 x 75mm Sockethead Cap Screws. 5mm Fender Washer (12) Included - (8) Required. #10 x 2.5" PH Wood Screws. (30) Included - (24) Required

Top Mount Ultra Modern Hanger

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H

ASSEMBLY INSTRUCTIONS FOR SL500A AND SL500AL

2 Section Slider Loft Ladder Instructions

Sliding Pocket Door Systems

ROCKWELL. Two Panel Door. Half X Door. Double X Door. Z Combination Door

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

INSTALLATION INSTRUCTIONS

ASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Tools Required Page 1. KIT CONTENTS: Smoking Shelter Page 1-2 Smoking Shelter Optional Extras Page 3

Use Deluxe PVC Cassette Roman Blind

Cellar Hanger ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Assembly Instructions

Section 1. Kitchen installation. Base cabinets

Vanity Installation Instructions

JELD-WEN DesignGlide Barn Door Hardware System Installation (JII-90003)

a.k.a. casegoods instructions

Baby Grande with Crank, Housing, and Side Rails Installation Instructions

TOYOTA MOTOR EUROPE CA Products Division Tel : Fax :

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H


Installation Instruction

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

Custom Wood Frame Overlay for Glass Doors Installation Instructions

Flat Panel Tilt Wall Mount (GPM-111)

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

GARAGE DOOR WITH TORSION SPRING

INSTALLATION INSTRUCTIONS

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

Industrial Hanger ASSEMBLY INSTRUCTIONS


Privacy Wall Glass Selections - Polished Edge Slider Door

Preference Collection and Treatment Console INSTALLATION GUIDE

LF Series Assembly Instructions

Queen Wingback Bed King Wingback Bed

SINCE 1922 P UBLICATION N O

Classic SportBar Camaro V6 or V8



Contour Hanger ASSEMBLY INSTRUCTIONS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

1. TOOLS + MATERIALS REQUIRED

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S

Shop Style Miter Saw Stand Kit

Oxford Stalls Installation Instructions

Use Cassette Roman Blind Kit

Assembly Instructions

ASSEMBLY INSTRUCTIONS. enook Pro

Timber Professional Complete Loft Access Kit

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

CHEVY/GMC SuperRail Mounting Kit #3117

Transcription:

The Pocket Door Kit FITTING INSTRUCTIONS - NOTICE DE POSE - MONTAGE HANDLEIDING - MONTAGEANLEITUNG ISTRUZIONI DI MONTAGGIO - INSTUCCIONES DE MONTAJE Warranty. This product is covered by a 10 year manufacturer s warranty. Please see the P C Henderson website for terms and conditions. WATCH THE INSTALLATION VIDEO Visit: www.pchenderson.com/pocket-door-installation Or scan the QR code using your phone Door sizes and kits numbers - for doors up to 60kg For doors up to and including standard door sizes 1981mm (78 ) high x 762mm (30 ) wide doors 1981mm (78 ) high x 838mm (33 ) wide doors 2040mm high x 762mm wide doors 2040mm high x 826mm wide doors 2040mm high x 726mm wide doors 2315mm high x 930mm wide doors Kit number PDK3 PDK4 PDK5 PDK6 PDK7 PDK10 Door thickness between 28mm and 44mm - Maximum door weight 60kg - Wall cavity 95mm Tools required 1 x Phillips screws driver 1 x Tenon wood saw (only needed if reducing kit in size) 1 x Spirit level 1 x Junior metal hack saw (only needed if reducing kit in size) 1 x Tape measure 1 x Allen Key - 5mm 1 x Drill + 2mm drill bit 1 x Adjustment spanner

Kit components 1 x Plastic guide 2 x Clipstops 2 x Hanger apron plates 1 x Rubber stop 2 x Hangers Screws shown actual size Screw A x 4 3 /4 CSK. HD. Pozi (19mm) Screw B x 8 1 BUT. HD. Pozi (25mm) Screw C x 8 1 3 /4 CSK. HD. Pozi (44mm) Screw D x 14 5 /8 BUT. HD. Pozi (16mm) Screw E x 8 1 1 /2 BUT. HD. Pozi (38mm) 2 x Stud insert brackets 1 x Track, head and end brackets 4 x Uprights including timber infill

Step 1 Preparing the Rough Opening Kit assumes installer is using standard (C10/C24) studwall timber 47mm x 100mm (actual size 45mm x 95mm) How to calculate the opening width required Opening width in mm = (Door width in mm x 2) + 30mm Opening height in mm = (Door height in mm) + 90mm Refer to Figure 1. Note: 90mm = door floor clearance 8mm + door to track clearance 28mm + header/track clearance 54mm Finished studwall is 95mm thick plus plaster board used i.e. 95+12.5+12.5 = 120mm Rough opening width - W (Including any liners) Rough opening height - H FFL Figure 1. Quick look up table for opening sizes when using UK standard door sizes Kit No. Standard door size Rough opening height - H Rough opening width - W PDK3 1981mm (78 ) high x 762mm (30 ) wide doors 2071mm 1554mm PDK4 1981mm (78 ) high x 838mm (33 ) wide doors 2071mm 1706mm PDK5 2040mm high x 762mm wide doors 2130mm 1554mm PDK6 2040mm high x 826mm wide doors 2130mm 1682mm PDK7 2040mm high x 726mm wide doors 2130mm 1482mm PDK10 2315mm high x 930mm wide doors 2405mm 1890mm Ensure that the rough opening is as square as possible to aid the fitting of the pocket door system, and so allowing the door to operate correctly when the installation is completed. For double doors the rough opening width is as for one door multiplied by 2 and the 2 kits MUST be fixed directly to a suitable lintel.the two middle support brackets are not to be used.

Step 2 - Install Guide screws Fit a guide screw - A to both frame uprights of the opening at the door height plus 28mm (measured from the Finished Floor Level - FFL).The screws should be fitted on the centre line of the cavity, refer to diagram for details (Fig 2.1). Fix both screws into the frame until the head of the screws are protruding about 3mm from the frame uprights. Screw - A Screw - A CL Height of Guide screws = Door Blank Height + 28mm Figure 2.1. Frame Upright (not by PCH) Frame Upright (not by PCH) Figure 2. Step 3 - Fit stud insert brackets FFL Using the Track and Head assembly as a template, mark on the floor between the vertical uprights with a soft pencil the lines as shown on diagram. These lines are the position of the stud insert bracket near the pocket opening. Fit remaining stud insert bracket half way between the rough opening upright and the first fitted stud insert bracket using screws - D (see Fig 5). Cavity side Opening side Pencil lines Intermediate stud bracket = = Figure 3. Pencil lines Figure 3.1.

Step 4 - Fitting the track & head assembly Insert both hangers and clipstops into the track with the hanger ears facing the clipstops at each end of the track, as shown in Fig. 4.1. Carefully lift the Head and Track assembly into the opening, then hook the metal brackets at both ends of the assembly on to the protruding guide screws fitted earlier. Then rotate the assembly into the final upright position (Fig.4).Whilst holding the assembly with one hand, screw the guide screws home at both ends.this should hold the Head and Track assembly in position with friction. Do not let go of the assembly if it is not held securely in place by the screws. Using a spirit level, check and correct the assembly ensuring it is level in all directions. Using screws B secure end brackets as indicated in Fig 4.2 & Fig 4.3. Ear Figure 4.1. Ear Screw - A Figure 4.2. Screws - D Screws - B Figure 4. Screw - A Screw - D Screws - B Figure 4.3.

Step 5 - Fit uprights Slot first upright into stud insert bracket (as indicated in Figure 5.) and line the top of the upright against the side of the wooden head fascia. Check upright for vertical alignment with a spirit level, then screw the top of the upright to the wooden header board through the slots on the back of the upright. Repeat this for the second upright on the opposite side. Slot the third upright on the intermediate stud insert bracket, use a spirit level to check vertical alignment and then screw the top of the upright in to the wooden header board, through the slots on the back of the upright, (as indicated in figure 5.1). Repeat step for the forth upright on the opposite side. Wooden header board Wooden head fascia Screws - D Upright Stud insert bracket Screws - C Figure 5. Upright Figure 5.1. Step 6 - Installing the guide Using screws A position the guide assembly on the centre line of the cavity and in front the of stud insert bracket (figure 6.), checking the distance between the guide uprights is correct for the thickness of the door before screwing down to the floor, do not overtighten. Pencil line Centre line Screws - A Guide fixed on centre line Pocket cavity Opening Figure 6.

Step 7 - Fitting the apron plates to the door The centre of the apron plates must be no closer to the corners of the door than 160mm (figure 7). Position the centres of the apron plates along the centre of the door blank. Using screws E fix both the hanger apron plates on to the top face of the door. Centre of the door blank Screws - E Hanger apron plate Centre of hanger > 160mm Figure 7. Step 8 Hanging of the door Move the hangers within the track to align with the hanger apron plates on the door. Carefully hook the door, via the apron plates, on to the bolt heads hanging beneath the hangers. The bolts heads must be firmly seated on the underside of the apron plates behind the apron plate ears.when in place adjust the door for height and alignment to the frame upright. When adjusted correctly screw down the lock nuts and tighten with spanner provided. Figure 8.

Step 9 The finishing touches Now with the door hung, position the clip stops to the desired positions within the track to limit the travel of the door, then tighten the clip stop bolts to fix in position. Remember that when the door is in the open position there will have to be enough of the door protruding from the pocket to pull the door shut.alternatively the door may be flush with the pocket if used in conjunction with the Henderson 395 flush door lockset. Screw the rubber stop supplied into the frame upright on the pocket side, in alignment with door, at a height of approximately 50mm above the FFL (as indicated in figure 9). When the installation of the Henderson Pocket Door Kit is complete and the door is running smoothly, the plaster board panels can be fitted to the uprights to create the wall pocket, and then the desired mouldings and skirting board to finish off. Rubber Stop Screw - B Figure 9. Ironmongery available To complement the installation of your Henderson Pocket Door System, we can supply a range of flush pulls and lock catches. Please contact P C Henderson sales department for further information. Reducing the kit size Kits can be reduced both in height and width to meet particular door sizes.to reduce the height of a kit cut down the uprights by the same amount, starting from the bottom of each upright (avoid cutting through the side slots). To reduce the width of the kit cut down the track and timber head assembly separately. Cut from the opening side by the difference between the kit door width and the door to be used in equal proportion. For further information contact the P.C. Henderson Technical Department. P C Henderson Limited, Durham Road, Bowburn, County Durham DH6 5NG, UK. Web: www.pchenderson.com UK Customer Services Department: Tel: +44 (0)191 377 7345 Fax: +44 (0)191 377 3116 Email: sales@pchenderson.com Export Department: Tel: +44 (0)191 377 7346 Fax: +44 (0)191 377 0755. Email: international@pchenderson.com. For all technical queries email our Technical Department: technical@pchenderson.com Part No: 666770 July 2017 -Issue 8