Product Evaluation Report

Similar documents
2012/2015 IBC Section VersaPin fasteners meet the intent of the IBC when installed in accordance with the manufacturer's installation

Aerosmith Fastening Systems 5621 Dividend Road Indianapolis, IN 46241

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

*Revised September 1, 2003

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

ESR-1799 Reissued June 1, 2009 This report is subject to re-examination in one year.

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Engineering Services Program

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015.

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013.

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

Joint Evaluation Report

ICC-ES Evaluation Report

REPORT HOLDER: JAACO CORPORATION NORTHEAST 68 TH STREET, SUITE C-130 REDMOND, WASHINGTON EVALUATION SUBJECT:

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

Exterior Wall Fastener Schedule

CITY OF LOS ANGELES CALIFORNIA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

Submittal / Substitution Request

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

Section Section Section

ROOFING APPLICATION STANDARD (RAS) No. 130

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

COMPOSITE SIDING INSTALLATION GUIDE

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED

eco-shake INSTALLATION INSTRUCTION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: ELCO CONSTRUCTION PRODUCTS 1032 KERR DRIVE DECORAH, IOWA 52101

Turada Hardwood Shingles and Shakes Installation instructions

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

PRODUCT EVALUATION Effective July 1, 2009 RC-204

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

RED DIAMOND SHINGLES Roof Installation Introduction:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

DIVISION 6 WOOD AND PLASTICS

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Load Tables, Technical Data and Installation Instructions

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

ForceField Air & Water Barrier System. installation instructions

ROOFING City of Grand Rapids Building Safety Division

APA Performance Rated Rim Boards

Roaring River, NC White City, OR CertainTeed Fiber Cement Plant 1001 W. Industrial Drive Terre Haute, IN 47802

Introduction. to Wall Bracing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

LAP SIDING INSTALLATION GUIDE

UL Construction No. 254

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

Building for High Wind Resistance in Light-Frame Wood Construction

REPORT HOLDER: SENCO BRANDS INC IVY POINTE BOULEVARD CINCINNATI, OHIO EVALUATION SUBJECT: SENCO SELF-DRILLING AND SELF-PIERCING SCREWS

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

PROJECT INSTRUCTIONS Roofing

THE ENGINEERED WOOD ASSOCIATION

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI SELF-DRILLING AND SELF-PIERCING SCREWS

Submittal Sheet. Product: Item# Description Unit Pack

SDWH TIMBER-HEX Screw

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER:

Product Information & Installation Instructions

CBUCK Engineering. for. Florida Product Approval # FL R1

3.1 General Provisions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

UNA-CLAD Metal Roof Systems

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: TREE ISLAND INDUSTRIES, LTD.

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

Shapes Siding. Perfection Shingles. Chalk Line

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

CITY OF LOS ANGELES CALIFORNIA

Installation Manual for M4-Exterior Sheathing

FASTENERS BUILDING DEPARTMENT

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

Transcription:

Product Evaluation Report PER0601 Page 1 of 6 Initial Listing September, 06 This Document Published By: ReApproved April, 08 Listed Product VersaPin Gripshank Pneumatic Fastener Listed For Aerosmith Fastening Systems 621 Dividend Road Indianapolis, IN 621 Progressive Engineering Inc. 860 State Road 1 7330337 Goshen, Indiana 628 www.pei.com Progressive Engineering Inc. is an accredited Testing Laboratory and Third Party Quality Control Agency. This Product Evalation Report represents a product that Pei has a followup service agreement with. This Product Evaluation Report in no way implies warranty for this product or relieves Aerosmith Fastening Systems of their liabilities for this product. Pei is accredited to ISO Standard 1 and 12. This Product Evaluation Report is an official document if it is within one year of the initial or reapproved date. Product Manufacturing The VersaPin Gripshank Fasteners are manufactured by independent companies. Any company manufacturing product for Aerosmith, that is intended to be listed by this Product Evaluation Report, has an agreement in place and has been approved and audited quarterly by Pei. Listing Details VersaPin Gripshank Fasteners are pneumatically driven steel pins used to attach siding and sheathing materials to steel stud framing. The pins pierce the steel framing while the specially designed shank grips the steel framing. The threaded portion of the shank must penetrate completely through the stud steel thickness. Product Description The VersaPin Gripshank Fasteners are manufactured from AISI 1060 steel, heat treated to a Rockwell C hardness between 2 and 6, have a minimum tensile strength of ksi and a bending yield strength of ksi. The pins are electrozinc plated with a chromate rinse or are mechanically zinc plated. The plating is a minimum thickness of.0002" thick. The pins are manufactured with a nominal finished shank dia. of." and a nominal head dia. of or. The shank has a proprietary thread and the point is ballistic shaped. The pins are identified by the Aerosmith logo head stamp as shown on page 2 of this Product Evaluation Report. The pins are collated for powered gun and air tool applications. Steel Framing The steel framing shall comply with ASTM A 63 SS (33 ksi) with the following minimum steel thickness for each nominal gage size. Minimum Gripshank Ultimate Gage Thickness Withdrawal Values 1.071" 16.0" 18.0".037" 22.033" 96 lbs. 9 lbs. 337 lbs. 28 lbs. 18 lbs. Approved Siding Material James Hardie Building Products / Hardipanel Vertical Siding & / Hardiplank Lap Siding or equivalent. See ICCES Legacy Report NER0. The siding is to be installed using the siding manufacturers Installation Instructions and Gripshank Fasteners. The minimum steel thickness to be used is gage.

PER0601 Page 2 of 6 Approved Exterior Sheathing DensGlass Gold Exterior Sheathing 1/2" and /8" Fireguard Type X. See ICCES Legacy Report ER30. The sheathing is to be installed using the sheathing manufacturers Installation Instructions and Gripshank Fasteners. The minimum steel thickness to be used is 22 gage. The Sureboard Series 0 Structural Panel /8" or 1/2" thick Type X gypsum board adhered to 22 ga. steel, listed on ICC ES ER161. Aerosmith pins shall be installed in compliance with manufacturers Installation Instructions. The minimum steel thickness to be used is gage. Approved Plywood Sheathing Plywood sheathing complying with USDC Product Standard PS1 or PS292 (UBC Standards 232 or 233) Aerosmith pins shall be installed in compliance with manufacturers Installation Instructions. The minimum steel thickness to be used is gage. Tested to ASTM E 330 Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Differences ASTM D 1037 Fastener Withdrawal Test ASTM E 72 Wall Racking Test Code Compliance 1997 Uniform Building Code 03 International Residential Code 06 International Residential Code 03 International Building Code 06 International Building Code 0 Florida Product Approval Application FL#900 The VersaPin Gripshank Fasteners are limited to use in resisting negative wind forces in this Product Evaluation Report. Fire Rated assemblies are outside of the scope of this Product Evaluation Report. Product Documentation VersaPin Gripshank Fastening Guidelines for Cement Fiber Board dated August,06 Aerosmith Installation Instructions for DensGlass Sheathing not dated Hardie Plank & HardiPanel Installation Instructions dated December, 0 SureBoard Installation guide for Aerosmith pins Densglass Gold Installation Recommendations dated 06 A Quality Control Manual for Aerosmith Fastening Systems Dated 9//0 A Quality Control Manual from each Approved Manufacturer An agreement between Product Evaluation Report owner (Aerosmith) & each Approved Manufacturer A followup Listing & Inspection agreement between PEI and Aerosmith Fastening Systems A Pei test report No. 0378 Fastener Withdrawal Test using Gripshank and Helical Shank Fasteners Dated 6/9/03 Stamped by a professional engineer. A Pei test report No. 07119 ASTM E72 Wall Racking Test with 19/32" APA Rated Sheathing and Aerosmith Gripshank Pins with Studs Spaced " o.c. Dated 8/1/07. A Pei test report No. 0798(A) ASTM E330 Test with /8" DensGlass Gold FireGuard Type X and Aerosmith Gripshank Pins with Studs Spaced o.c. Dated 9/06/07 Stamped by a professional engineer. A Pei test report No. 0798(B) ASTM E330 Test with /8" DensGlass Gold FireGuard Type X and Aerosmith Gripshank Pins with Studs Spaced o.c. Dated 9/06/07 Stamped by a professional engineer. A Pei test report No. 0639(A) ASTM E330 Test with Hardipanel and Aerosmith Gripshank Pins with Studs Spaced o.c. Dated 2/28/06 Stamped by a professional engineer. A Pei test report No. 0639(B) ASTM E330 Test with Hardipanel and Aerosmith Gripshank Pins with Studs Spaced o.c. Dated 3/1/06 Stamped by a professional engineer. A Pei test report No. 0639(C) ASTM E330 Test with 61/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 2/28/06 Stamped by a professional engineer.

PER0601 Page 3 of 6 Product Documentation A Pei test report No. 0639(D) ASTM E330 Test with 71/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 2/28/06 Stamped by a professional engineer. A Pei test report No. 0639(E) ASTM E330 Test with 81/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 3/1/06 Stamped by a professional engineer. A Pei test report No. 0639(F) ASTM E330 Test with 61/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 2/27/06 Stamped by a professional engineer. A Pei test report No. 0639(G) ASTM E330 Test with 71/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 2/28/06 Stamped by a professional engineer. A Pei test report No. 0639(H) ASTM E330 Test with 81/" Wide Hardiplank Nailed using Aerosmith Gripshank Pins Dated 3/1/06 Stamped by a professional engineer. A Pei test report No. 0639(I) ASTM E330 Test with 61/" Wide Hardiplank Nailed Over 1/32" Plywood using Aerosmith Gripshank Pins Dated /10/06 Stamped by a professional engineer. A Pei Allowable Wind Speed Calculation, project No. 061268, for Hardipanel & Hardiplank using Aerosmith Gripshank Pins Dated 8/8/06 Stamped by a professional engineer. A Pei test report No.0309(A) ASTM E330 Test with /8" DensGlass and 18 Gauge Steel framing Grip Shank Fasteners @ 8"o.c. Dated /2/03 Stamped by a professional engineer. A Pei test report No.0309(B) ASTM E330 Test with /8" DensGlass and 22 Gauge Steel framing Grip Shank Fasteners @ 8"o.c. Dated //03 Stamped by a professional engineer. A Pei test report No.0309(D) ASTM E330 Test with 1/2" DensGlass and 22 Gauge Steel framing Grip Shank Fasteners @ 8"o.c. Dated /6/03 Stamped by a professional engineer. ICCES Legacy Report ER667 Reissued December 1, 02 DH Brown Associates Test Report p No. B9216 Not Dated p g with Aerosmith Pins (Tables ONLY) p p g with Aerosmith Pins A Specialized Testing report No. STQA009 SureBoard Series 0 Structural Panels racking shear tests and shear walls. Dated 11/21/06 Product Labeling Each Box of fasteners shipped, that are covered by this Product Evaluation Report, must have a label attached with at least the following information: Head Stamps 1. Aerosmith Fastening Systems name, address or website. 2. Fastener designation 3. This Product Evaluation Report number & Pei's logo. The catalog number. A lot number & Mfg. Plant Identification/Traceability 6. A Trademark head stamp by Aerosmith as shown Dia. Head Dia. Head

PER0601 Page of 6 Maximum Allowable Wind Speed (mph3 second gust) Based on 06 IBC section 1609.1.1(ASCE 7 0) Siding Type & Dimensions Exposure Nominal Head Nailing Method Stud Spacing Zone B C D Diameter 1' 30' 1' 30' 8" x 96" Hardipanel Vertical Siding 8" x 96" Hardipanel Vertical Siding / tk. x 61/" wide Hardiplank Lap Siding / tk. x 71/" wide Hardiplank Lap Siding / tk. x 81/" wide Hardiplank Lap Siding / tk. x 61/" wide Hardiplank Lap Siding / tk. x 71/" wide Hardiplank Lap Siding / th. x 81/" wide Hardiplank Lap Siding / th. x 61/" wide Hardiplank Lap Siding with 1/32" Plywood Underlayment 1 8 8 1 10 10 10 10 10 1 10 10 1 1 1 1 1 1 8 8 8 8 1 Maximum Allowable Wind Speed (mphfastest mile) Based on 1997 UBC Exposure Siding Type & Dimensions Nominal Head Nailing Method Stud Spacing Zone B C D Diameter 1' 30' 1' 30' 8" x 96" Hardipanel Vertical Siding 8" x 96" Hardipanel Vertical Siding / tk. x 61/" wide Hardiplank Lap Siding / tk. x 71/" wide Hardiplank Lap Siding / tk. x 81/" wide Hardiplank Lap Siding / tk. x 61/" wide Hardiplank Lap Siding / tk. x 71/" wide Hardiplank Lap Siding / th. x 81/" wide Hardiplank Lap Siding 1 1 1 1 1 / th. x 61/" wide Hardiplank Lap Siding with 1/32" Plywood Underlayment 1. For Vertical Siding, pins were set 8" o.c. in the field, " o.c. around the perimeter, 3/8" from panel edge & 2" from corners. 2. For Lap siding, butt joints were placed at 1/3 and 2/3 of wall height, siding was overlapped 11/", and pins were set at 3/8" form siding end and 3/" up from bottom edge. 3. All siding used Gripshank fasteners, ga x 33ksi CWN Cstuds (depth = 13/8", flange = 3/8", and a return = 3/8"), wall heights for the above values = 30ft or less.. Zone is the interior section of the wall between Zone s & Zone is the section within a minimum of 3 ft of all corners.

PLS0601 Page of 6 Tested Design Values Siding Type & Dimensions Nominal Head Diameter Fastener Spacing Gage Tensile Strength Stud Spacing Design Load /8" Densglass Fireguard Gold Type X 8" o.c. 16 ga. 0 KSI 38.1 PSF /8" Densglass Fireguard Gold Type X 8" o.c. 16ga. 33 KSI 0.3 PSF /8" Densglass Fireguard Gold Type X 8" o.c. 18 ga. 33 KSI 2. PSF /8" Densglass Fireguard Gold Type X 8" o.c. 22ga. 33 KSI 2.7 PSF /8" USG Sheetrock Type X Gypsum 8" o.c. 22ga. 33 KSI 22.9 PSF 1/2" Densglass Gold 8" o.c. 22 ga. 33 KSI 23.3 PSF 1. Pins were installed 8" o.c. in the field, 8" o.c. around the perimeter, 3/8" from panel edge & 2" from corners. 2. All studs were CWN Cstuds (depth = 13/8", flange = 3/8", and a return = 3/8"), wall heights for the above values = 30ft or less for Exposure B. Exp. C and D are divided into values for 1ft. And 30ft. 3. Zone is the interior section of the wall between Zone s & Zone is the section within a minimum of 3 ft of all corners. Plywood Grade Maximum Allowable Shear for Plywood Shear Walls using." Pins (lbs per foot) Framing Spacing Minimum Steel Gage Minimum Panel Thickness 3/8" 6" on Edge 1 " on Edge 23 Pin Spacing 3" on Edge 310 2" on Edge 39 " on Edge 8" in Field Structural I 7/ 1 2 30 3 1/32" 30 10 Grades other than Structural I 3/8" 7/ 1/32" 10 1 18 210 230 27 2 310 3 360 3 APA Rated 16 19/32" 1.9 Sheathing 1. Values listed are test values and have not been changed by wind or seismic adjustment factors. 2. The minimum panel edge distance for pin placement is 3/8 inch 3. The tracktostud connection is permitted to be any means of one." diameter by 3/" long Aerosmith pin at each trackto stud connection, for a total of two at each end to each stud.

PLS0601 Page 6 of 6 Fasteners Spacing Studs Sheathing Holdowns Peak Force Mean Drift (In.) Screw = No. 8 x 1 3/" / Aerosmith 1 3/8" x 1/in. SureBoard Series 0 Structural Panel Racking Resistance 16Gauge ft. X 9ft. SureBoard Series 0 1/" Magnesium Board SHD1 9981 LBS 1.238" Screw = No. 8 x 1 3/" / Aerosmith 1 3/8" x 1/in. 18Gauge ft. X 9ft. SureBoard Series 0 1/" Magnesium Board SHD1 83 LBS 1.196" Screw = No. 8 x 1 3/" / Aerosmith 1 1/" x /16in. 16Gauge ft. X 9ft. SureBoard Series 0 /8" Densglass Gold (2)SHD10 (1) SHD1 11 LBS 1.606" Screw = No. 8 x 1 3/" / Aerosmith 1 1/" x /16in. 18Gauge ft. X 9ft. SureBoard Series 0 /8" Densglass Gold (2)SHD10 (1) SHD1 9797 LBS 1.0" * The spacing for the Grabber Screws and Aerosmith pins are as follows: Vertical Perimeter Fasteners Screws are 12" oncenter (o.c.); five() Aerosmith pins installed between screws at approximately 2" o.c. Vertical Field Fasteners Screws were 12" o.c.; Aerosmith Pins Gripshank Pins in collated form Boxes of Gripshank Pins as shipped www.aerosmithfastening.com