Positioner with HART Communication Type 3780

Similar documents
SALES SERVICE +358 (0)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

IP26 Series Current to Pneumatic Converter

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

OEM radar transmitter, for aggressive media level measurement

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Resistance thermometer Model TR30, compact design

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Type 3374 Electric Actuator

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Fisher 646 Electro Pneumatic Transducer

SITRANS T measuring instruments for temperature

Head mounted Temperature Transmitter TF02/TF02-Ex

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Rail mounted Temperature Transmitter TH102/TH102-Ex

Field indicator for current loops with HART communication Models DIH50, DIH52

Temperature Measurement

Resistance thermometer Model TR30, compact design

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Isolators A3/1. Vibration Transducer Supply Unit Series

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount 148 Temperature Transmitter

Temperature Input Module for Zone 1 Series 9482/32

FieldIT Temperature Transmitter, field mounted TH202/TH202-Ex

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Technical Data. General specifications. Rated operating distance s n 3 mm

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Assembly. Front view. Power Rail

SITRANS P. Transmitters for level. Introduction 1/42. Application

Ultrasonic level measuring device, non-contact

Isolating Repeater Input Series 9163

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Single-Channel Safety Barriers Series 9001

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Digital Input Output Module for Zone 2 Series 9470/33

0 2 1 â Ó. itemp HART TMT182. Technical Information

Fisher 646 Electro-Pneumatic Transducers

Inductive sensor slot-type SI2-K08-AP7

Binary Output Series 9175

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

KFS. Flap-type flow meter. Design and range of application

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Temperature Measurement Transmitters for mounting in sensor head

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

0 2 1 â Ó. itemp HART TMT182. Technical Information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Temperature Measurement Transmitters for mounting in sensor head

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

Remote I/O. 74 Remote I/O. Remote I/O System

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Resistance thermometer Model TR30, compact design

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Design and applications

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

LST100 Ultrasonic level transmitter for upstream oil and gas

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Isolators A3/1.

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Technical Information Barrier RB223

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Process Protection Acoustic sensors for pump monitoring

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

FOR RELIABLY MEASURING +

Field IT 2600T Series Pressure Transmitters

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter

Level Measurement Continuous level measurement Radar transmitters

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Temperature Measurement

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

HART field temperature transmitter Models TIF50, TIF52, TIF62

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Resistance thermometers for process technology

Operating Instructions

Transcription:

Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels from to 2 mm Opening angle up to 120 Smart instrument according to the HART Field Communication Protocol. Types of protection EEx ia, EEx n or EEx d. The microprocessor-controlled positioner ensures a predetermined assignment of the valve stem position to the electric input signal. It compares the to 20 ma input signal received from a control system to the travel of the control valve and generates the corresponding output signal pressure (output variable). Suitable for attachment to both linear and rotary actuators The Type 780 Positioner is equipped with an interface which complies with the HART Field Communication Protocol, enabling connection to a PC or HART -compatible handheld communicator (configurator) for bidirectional data exchange. SAMSONs TROVIS-VIEW software and the device-specific database module can be used to configure and parameterize the positioner. The positioner can, however, also be operated with other suitable software packages. Version for hazardous areas with type of protection "Intrinsic safety" EEx ia IIC T6, EEx n for Zone 2 or in combination with Type 770 Field Barrier with "Flameproof enclosure" EEx d The digital data processing feature offers the following advantages over conventional positioners: Automatic adjustment of zero and span on initialization Automatic detection of errors in the actuator or pneumatic system Operating direction selectable using software functions and independent of the mounting position Selectable characteristics Simple modification of control parameters even during operation Monitoring and diagnostic functions, e.g. self-test functions for fault alarm output, software limit switches and position transmitters; total valve travel (travel integral) Supports extended valve diagnostics using TROVIS EXPERT software Continuous monitoring and adjustment of zero Minimum air consumption Permanent storage of all parameters in the EEPROM Optionally available with forced fail-safe venting to vent the actuator via the 2/2-way valve (Fig., item ) upon failure of the external signal. As a result, the control valve is forced to move to its fail-safe position. This function can be activated using a hardware switch. Fig. 1 Type 780 Positioner with HART Communication Fig. 2 Ex d positioner with Type 770 Field Barrier Write protection switch Fig. Type 780 Positioner with opened cover Associated Information Sheet T 80 EN Edition January 2006 Data Sheet

Principle of operation The travel of the final control element is sensed using the non-contact inductive travel sensor (1) and transmitted to the microcontroller (2) via a converter. In the microcontroller, the travel is compared to the set point, and the two pneumatic 2/2-way switching valves (, ) are activated whenever a system deviation occurs. Depending on the deviation, these valves either add air to () or vent air by () the pneumatic actuator using corresponding boosters. A second microcontroller () manages the communication according to the HART Field Communication Protocol. The frequency shift keying (FSK) signal used for communication is superimposed on the electric input signal. The TROVIS-VIEW software package can be used to alter and select all required parameters and download these to the positioner. After that, the positioner can operate independently of the PC or handheld communicator. By default, the positioner is equipped with a fault alarm output used to indicate various errors and other relevant alarms. A write protection switch located on the inside of the cover prevents that saved configuration data are overwritten unintentionally. FSK 2 1 Additional equipment Options to extend the function range of the positioner include: Two inductive limit switches (proximity switches) or two software limit switches (to be configured over the software) One analog position transmitter which, independently of the reference input signal, converts the valve stem position into an analog output signal (operating direction can be configured via the software) 1 Inductive travel sensor 2 Microcontroller 2/2-way valve 2/2-way valve Microcontroller FSK Frequency shift keying signal for communication Fig. Functional diagram of Type 780 Positioner Fig. TROVIS-VIEW Configuration and Operator Interface, dialog box for user-defined characteristic 2

Table 1 Technical data Travel Direct attachment to Type 277: Attachment acc. to IEC 60-6 (NAMUR): Reference input signal w Minimum current Load impedance Supply air Output signal pressure Characteristic Air quality acc. to ISO 871 (2001) Adjustable to 0 mm to 2 mm or 0 to 120 with rotary actuators Signal range: to 20 ma Span: to 16 ma Static destruction limit: 00 ma.6 ma 10.8 V (corresponds to 0 Ω at 20 ma) 1. to 6 bar (20 to 90 psi) Maximum particle size and density: Class 2 Oil contents: Class Pressure dew point: Class or at least 10 K below the lowest expected ambient temperature 0 bar up to capacity of the supply pressure Adjustable: linear/equal percentage/reverse equal percentage/freely programmable Deviation from terminal-based conformity: 1 % Dead band Adjustable from 0.1 to 10 %, default: 0. % Resolution 0.0 % Transit time Operating direction Air consumption Air output capacity Permissible ambient temperature Temperature influence Supply influence Effect of vibration 7 s separately adjustable for exhaust and supply air Reversible, selection via software Independent of supply air < 90 ln/h Add air to actuator At Δp = 6 bar: 9. mn /h, at Δp = 1. bar:. mn /h Vent air from actuator At Δp = 6 bar: 1. mn /h, at Δp = 1. bar:.8 mn /h 20 to 80 C 0 to 80 C with metal cable gland For devices equipped with position feedback only 20 to 80 C The limits of the EC Type Examination Certificate listed in Table additionally apply to explosionprotected devices. 0.1 %/10 K None None up to 20 Hz and g Explosion protection II 2 G EEx ia IIC T6 / II 2 D IP 6 T 80 C or II G EEx na II T6 / II D IP 6 T 80 C Degree of protection Electromagnetic compatibility Electrical connection Fault alarm output Forced fail-safe venting Input Kv value Static destruction limit Weight Communication Hardware and software requirements Data transmission Software functions Additional equipment Inductive limit switches Software limit switches Analog position transmitter Output Characteristic Hysteresis Operating range Power supply Permissible load Resolution High-frequency influence Influence of power supply Temperature influence IP 6 using the filter check valve included with the positioner Complies with EN 61000-6-2, EN 61000-6- and NAMUR Recommendation NE 21 requirements One M20x1. cable gland for to 1 mm clamping range Second M20 x 1. threaded connection additionally exist Screw terminals for 0.2 to 2. mm 2 wire cross-sections For connection to signal converter according to EN 60 97--6 Static destruction limit: 16 V To be activated via internal switch 6 to 2 V DC Ri approx. 6 KΩ at 2 V DC (voltage-dependent) Switching point for "1" signal at V Switching point for "0" signal only at 0 V 0.17 V Approx. 1. kg TROVIS-VIEW Configuration and Operator Interface (see Data Sheet T 6661 EN) Handheld communicator, e.g. Type 7 by Emerson Process Management DTM acc. to Specification 1.2 Integration of other user interfaces possible HART Field Communication Protocol Impedance in HART frequency range: receive 0 to 0 Ω, send approx. 11 Ω Automatic start-up; setting of characteristic, operating direction, reference input signal range and transit time; limitation of the travel range; cross-over correction; automatic zero correction; fault alarms; total valve travel (travel integral); diagnostic alarms; device information; nonvolatile storage of data; test functions; logging via IBIS For connection to signal converter according to EN 60 97--6, two SJ2-SN inductive proximity switches For connection to signal converter according to EN 60 97--6, two configurable limit values Hysteresis: 1 % Two-wire transmitter to 20 ma ; operating direction reversible Linear (deviation 1%, incl. influence of mechanical deflection for NAMUR attachment) 0. % 10 to 11 % 12 to V DC US 12 V R B = 20 ma 0.0 % < 2 % at f = 0 to 80 MHz None Same as positioner

Table 2 Materials Housing Die-cast aluminum, chromated and plastic-coated External parts Stainless steel 1.71 and 1.01 Table Data which additionally apply to explosion-protected Type 780-1... Positioner Permissible maximum values for Signal circuit Position transmitter Forced venting Inductive limit switches Type 780-12 Software limit switches Type 780-1 Fault alarm output Ui 28 V 16 V 16 V 20 V Ii 11 ma 2 ma 2 ma 60 ma Pi 1 W 0. W 169 mw 6 mw 20 mw Ci. nf Negligibly small 60 nf 60 nf. nf Li μh Negligibly small 200 μh 200 μh Negligibly small Ambient temperature ranges in C Temperature class Signal circuit Forced venting function Fault alarm output Software limit switches Inductive limit switches at Position transmitter T6 0 to 60 C 20 to 60 C T 0 to 70 C 20 to 70 C T 0 to 80 C Ii = 2 ma 0 to C 0 to 60 C 0 to 7 C Ii = 2 ma 0 to 60 C 0 to 80 C 0 to 80 C 20 to 80 C Summary of the explosion protection certificates for Type 780 Type of approval Certificate number Date Comments EC Type Examination Certificate First Addendum Second Addendum PTB 00 ATEX 208 2000-0-0 2000-10-10 200-01-1 II 2G EEx ia IIC T6;.-volt version Changes in EMC II 2D IP 6 T 80 C, Zone 21; Type 780-1 Statement of Conformity First Addendum PTB 02 ATEX 20 X 2002-0-0 200-01-1 II G EEx na II T6, Zone 2 II D IP 6 T 80 C, Zone 22; Type 780-8 FMRC approval Revision OD6A.AX 1998-02-2 2002-02-20 Class I, II, III; Div. 1, Groups A-G; NEMA Type X Cl. I, Div. 2, Groups A, B, C, D;.-volt version; Type 780- CSA approval LR 227-29 11812 1998-08-1 2002-0-1 Class I; Div. 1; Groups A, B, C, D Type Enclosure Class 1, Zone 0, Ex ia IIC T6;.-volt version; Type 780- GOST approval 2002.C299 2002-12-26 1 Ex ia IIC T6 X, valid until 2008-01-01; Type 780-1 AUS approval AUS Ex 621 X 2000-07-18 Ex ia IIC T6, Class I, Zone 0; -volt version Ex n IIC T6, Class I, Zone 2; Type 780-6 JIS approval C 186 May 2002 Ex ia IIC T6,.-volt version; Type 780-7 The test certificates are included in the Mounting and Operating Instructions and are available on request. Refer to Data Sheet T 879 EN for EEx d certificates concerning the Type 770 Field Barrier.

Electrical connection i GW2 GW1 G i 0 PE 1211 21 21 8 8 8281 2 1 Communication 6 to 2 V DC Signal converter acc. to EN 60 97--6 U S Control signal i ma Limit switches Fault alarm Forced venting Supply voltage for position transmitter Fig. 6 Electrical connection for Type 780 Positioner including additional equipment Connecting the positioner The Type 780 Positioner can be operated as a single unit (point-to-point communication), in multi-drop mode or over a multiplexer. Figs. 7 to 9 illustrate how the unit is to be connected. The signal converters in the explosion-protected version () are only required when Type 780 Positioner is used in hazardous areas. PC PC Safe area Hazardous area...20ma 1 2 780 1 780-1 Fig. 7 Point-to-point communication of Type 780 Safe area Hazardous area PC 780-1 1 2...20 ma 780-1 780-1 Fig. 8 Point-to-point communication of Type 780-1 Positioner in hazardous area 1 FSK modem 2 Handheld communicator (suitable for hazardous areas) Controller / control station Signal converter for version for hazardous areas Control valve Fig. 9 Communication over multiplexers illustrated in this case using an FSK bus

Attachment of the positioner Dimensions in mm The Type 780 Positioner can be mounted directly to the All pneumatic connections Type 277 Actuator using a connection block. For actuators ISO 228/1- G 1 or 1-18 NPT with fail-safe action "Actuator stem extends" and for Type 277- (120 cm 2 effective area), the signal pressure is Direct attachment to routed to the diaphragm chamber through an internal bore in Type 277 Actuator Supply (9) 28 the actuator yoke. For actuators with fail-safe action "Actuator Output (6) M20 x 1. stem retracts" and effective areas of 20 cm 2 or larger, the signal pressure is routed to the diaphragm chamber over ready- made external piping. Using an adapter plate, the positioner can also be easily attached to either side of the actuator according to IEC 60-6-1 (NAMUR recommendation). Attachment to the Type 278 Rotary Actuator or other rotary actuators according to VDI/VDE 8 requires an intermediate piece. The rotary motion of the actuator is converted into a linear motion via a cam disk. The cam disk is designed for 86 angles of either 0 to 90 or 0 to 120. The characteristic can 78. be selected using the software. 198 For double-acting springless actuators (without spring return), a reversing amplifier is required to generate the second opposed signal pressure. 1 0. 27 16 0 10 Attachment acc. to IEC 60-6-1 and NAMUR N1=11 N2=200 9 7 NPT ½ M20 x 1. 78. 8 16 27 6 10 10 16 Ex 198 78. 86 cor.tem 86 Ø 90 10 Attachment to rotary actuators Output1 (A1) 28. Supply (Z) Output2 (A2) Type 780 Ex d Positioner with Type 770 Field Barrier 28. 6 7 198 1 Fulcrum 0 16 27 82 10 9 78. 6 0 86 Reversing amplifier (optional) 6

Article code Positioner Type 780- x x x x x 2 1 0 0 0 0 0 Explosion protection Without 0 II 2 G EEx ia IIC T6 acc. to ATEX 1 FM/CSA Ex ia Australia Ex (Zone 0 and Zone 2)6 0/ JIS Japan 7 0/ II G EEx na II T6 acc. to ATEX 8 Limit switches Without 0 2 x inductive 2 2 x software Forced venting Without 0 With 1 Position transmitter Without 0... 20 ma 1 Pneumatic connections 1-18 NPT 1 ISO 228/1 - G 1 2 Ordering text Positioner with HART Communication Type 780-... (see article code) Optional TROVIS-VIEW operator interface FSK modem Pressure gauge for signal pressure: Without/without For positioners with limit switches: Tag outside active zone Contact closed/ Tag inside active zone Contact opened Attachment to Type 277 Actuator: Actuator sizes 120/20 0/700 cm 2 Fail-safe action: Actuator stem extends/retracts Attachment according to IEC 60-6-1 (NAMUR): Travel: mm Stem diameter: mm (if applicable) If applicable, signal pressure restrictions for actuators with small travel volumes Attachment to rotary actuators: Type 278, actuator sizes 160/20 cm 2 Attachment to single-acting or double-acting rotary actuators according to VDI/ VDE 8: If applicable, signal pressure restrictions for actuators with small travel volumes Specifications subject to change without notice. 7

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 601 Frankfurt am Main Germany Phone: 9 69 009-0 Fax: 9 69 009-107 Internet: http://www.samson.de