Fluke 40/41 Power Harmonics Analysers

Similar documents
Emicon Engineering Consultants L.L.C.

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

79/26 Series III Multimeter

ABB n.v. Power Quality Products, October 2014

22.0 Harmonics in Industrial Power Systems

Effects of Harmonic Distortion I

Generator Advanced Concepts

Use only for doing work with or for BC Hydro. Complete Legal Acknowledgement is at

Thermal Imaging, Power Quality and Harmonics

Power Factor & Harmonics

Active Harmonic Filter (AF3)

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Tuningintobetter power quality

How adjustable speed drives affect power distribution

Understanding Harmonics

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

ECET Modern Power

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Preface...x Chapter 1 Electrical Fundamentals

Low Pass Harmonic Filters

Load Isolation Transformers

80i-110s AC/DC CURRENT PROBE

Power Quality Monitoring and Power Metering Tutorial

Data Sheet. RISH Master Record %THD

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

6L]LQJ$8366\VWHP )RU1RQ/LQHDU/RDGV

Maintain power systems, troubleshoot power problems, diagnose equipment failures

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

DM-III Multitest & DM-III Multitest F Power Quality Recorders

General Description & Features Selection Charts Definition of Terms... 42

Technical Datasheet. Delta Power 1000A / 400A AC-DC

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

BENNING. CM7 Electrical Tester. Service Information

Fluke 83V and 87V Digital Multimeters

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Fluke 3540 FC Three-Phase Power Monitor

TOSHIBA International Corp

1C.4.1 Harmonic Distortion

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fundamentals of Power Quality

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

HAWK5000 Operators Manual

Est Static Frequency Converter. SFX 10kVA - 10MVA

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

High precision measurement system for current and voltage IHC-A/B-RM01/03

DM-5 Power Quality Analyzer

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

1587/1577 Insulation Multimeters

Alternator winding pitch and power system design

Digital Multifunction Instrument - Rish Master 3440

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Harmonic Requirements

An easy-to-use Precision Power Analyser. The touch of a button gives direct readout of true power and a host of other useful measurements.

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

LH240 LH1040 LH2040 LH2015

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Harmonic Mitigating Transformer - Technical Guide

Multimeter 500CVD21 RTU500 series

DM-III MULTITEST Power Quality Recorder

Fluke 192/196/199. ScopeMeter. Users Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Fluke 3540 FC Three-Phase Power Monitor

312, 316, 318. Clamp Meter. Users Manual

Electromagnetic Harmonic Filters Technical Guide

There s Gold in Those Waveforms Richard P. Bingham, Dranetz-BMI

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

ICM 136R Operating Instruction Electrical Clamp-Multimeter

Fluke Norma 4000/5000

SECTION 1 INTRODUCTION

Effective Harmonic Mitigation with Active Filters

CHAPTER 4 HARMONICS AND POWER FACTOR

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

NJWA - Harmonics and Drives Proper System Design

An Introduction to Power Quality

Harmonics, its Mitigation & Result of Case study of Spinning Mill

N. TEST TEST DESCRIPTION

AC Sources for IEC 1000 Harmonics and Flicker Testing

METRAClip87 and 88 Clamp Multimeters

Transcription:

Data Pack A Issued March 2002 232-4752 Fluke 40/41 Power Harmonics Analysers This data sheet refers to the Fluke 40 and Fluke 41 Power Harmonics Analysers. RS stock no. Description 215-9621 Fluke 41B power harmonics analyser 408-8751 801-1000s 1000A current probe Worldwide there is an increasing concern about the effects of power harmonics on electrical systems. Using their knowledge of hand held test equipment and digital signal processing techniques Fluke developed these affordable, practical tools to diagnose power harmonics problems. Why are power harmonics a problem? Symptoms of harmonics usually show up in the power distribution equipment that support the non-linear loads. There are two basic types of non-linear loads - single-phase and three-phase. Single-phase nonlinear loads are prevalent in offices, while three-phase loads are widespread in industrial plants. Figure 1 Typical non-linear load current waveform (single phase) What are power harmonics? Power harmonics are caused by non-linear loads such as inverters (drives) and switch mode power supplies, even electronic ballasts for fluorescent lighting. Linear loads draw current in sine-waves at the supply frequency, non-linear loads do not, these electronically controlled loads tend to draw current in short pulses causing a distorted current waveform to be drawn from the supply. Figure 2 Typical non-linear load current from a three-phase application ac theory demonstrates that non-linear current consumption actually consists of a sum of current at the supply frequency and at multiples of the supply frequency. These multiples are the harmonics. For example if the supply frequency is 50Hz then the second harmonic is 100Hz and the third harmonic is 150Hz, and so on. Because the electrical distribution system has a source impedance greater than 0Ω, large harmonic currents will cause harmonics to appear on the supply voltage. When this rises to significant levels it may cause additional problems. Each component of the power distribution system manifests the effects of harmonics a little differently. Yet all are subject to damage and inefficient performance.

Neutral conductors In a 3-phase, 4-wire system, neutral conductors can be severely affected by non-linear loads connected to single-phase branch circuits. Under normal conditions for a balanced linear load, the fundamental 50Hz portion of the phase currents will cancel in the neutral conductor. In a 4-wire system with single-phase non-linear loads, certain odd numbered harmonics called triplens (odd multiples of the third harmonic: 3rd, 9th, 15th etc.) do not cancel, but rather add together in the neutral conductor. In systems with many single-phase nonlinear loads, the neutral current can actually exceed the phase current. The danger here is excessive overheating because there is no circuit breaker in the neutral conductor to limit the current as there are in the phase conductors. Excessive current in the neutral conductor can also cause higher than normal voltage drops between the neutral conductor and ground at the 240V mains sockets. Circuit breakers Common thermal-magnetic circuit breakers use a bimetallic trip mechanism which responds to the heating effect of the circuit current. It is designed to respond to the true rms value of the current waveform and therefore will trip when it gets too hot. This type of breaker has a better chance of protecting against harmonic current overloads. A peak sensing electronic trip circuit breaker responds to the peak of current waveform. As a result it won t always respond properly to harmonic currents. Since the peak of the harmonic current is usually higher than normal, this type of circuit breaker may trip prematurely at a low current. If the peak is lower than normal the breaker may fail to trip when it should. Bus bars and connecting lugs Neutral bus bars and connecting lugs are sized to carry the full value of the rated phase current. They can become overloaded when the neutral conductors are overloaded with the additional sum of the triplen harmonics. Electrical panels Harmonics can occasionally effect electrical panels. Panels that are designed for use with 50Hz current may become resonant to the magnetic field generated by higher frequency harmonic currents. If this happens a panel can vibrate and emit a buzzing sound at the harmonic frequency. losses. Higher frequency harmonics cause increased core loss due to eddy currents and hysteresis, resulting in more heating than would occur at the same 50Hz current. These heating effects mean that transformers need to be derated for harmonic loads or replaced with specially designed transformers. Generators Standby generators are subject to the same kind of overheating problems as transformers. Because they provide emergency back-up for harmonic producing loads such as data processing equipment they are often even more vulnerable. In addition to overheating, certain types of harmonics produce distortion at the zero crossing of the current waveform which causes interference and instability for the generators control circuits. Motors Where there is a significant harmonic voltage present on the supply to a motor, certain harmonics can cause a rotating field that opposes the rotation of the motor. Although this may have little apparent effect on the rotation of the motor, it can cause overheating and subsequent damage to the motor. Power factor Harmonics is not only a major contributor to adverse power factor, but can also cause overheating of power factor correction capacitors. Classification of harmonics Each harmonic has a name, frequency and sequence. The sequence refers to phasor rotation with respect to the fundamental (F), i.e. in an induction motor, a positive sequence harmonic would generate a magnetic field that rotated in the same direction as the fundamental. A negative sequence harmonic would rotate in the reverse direction. The first nine harmonics along with their effects are listed below. Name F 2nd* 3rd 4th* 5th 6th* 7th 8th* 9th Frequency 60 120 180 240 300 360 420 480 540 Sequence + - 0 + - 0 + - 0 * Even harmonics disappear when waves are symmetrical (typical for electrical circuits) Sequence Rotation Effects from skin effect, eddy currents, etc.) Positive Forward Heating of conductors, circuit breakers, etc. Negative Reverse Heating as above + motor problems Zero** None Heating, + add in neutral of 3-phase, 4-wire system ** Zero sequence harmonics (odd multiples of the 3rd) are called Triplens (3rd, 9th, 15th, 21st, etc.) Transformers Where a substation has a delta-why transformer, there are two potential problems caused by harmonics. Firstly, single phase non-linear loads produce triplen harmonics which algebraically add up in the neutral. When this neutral current reaches the transformer it is reflected into the delta primary winding where it circulates and causes overheating which may lead to transformer failures. Secondly, since transformers are rated for 50Hz use harmonic currents can cause core losses and copper 2

Fluke 40 and 41 power harmonic meters The Fluke 40 and 41 measure the voltage and current (via the 500A current transformer supplied) of the circuit under test. It can then display the voltage, current or power as a waveform, a bargraph of the harmonics or as a digital display. Fluke have designed these harmonics analysers to be simple to use, all functions and displays are easily accessed via the fewest possible key presses, so there are no menus to work through. The tester uses a set of nine multi-purpose screens to present each type of measurement (Volts, Amps or Watts) as a waveform, a relational bar chart of harmonics, or a series of digital (text) readouts. One key selects between Volts, Amps and Watts, whilst another selects the display type. With multiple values and computations on each screen it becomes simple to access all the information about the power, voltage or current at the test point. When selected a Record function stores Max, Min, and Average readings that can be easily accessed with the cursor keys when on a text screen. Display: Rms, peak, and dc components of measured voltage. The %THD of voltage referenced to either fundamental (%THD- F) or total rms value (%THD-R). Application:Summarising measured quantities. Current measurement Voltage measurements Display: One cycle of the fundamental waveform and its frequency. Instantaneous voltage at cursor position. Application: Detecting flat-topped voltage caused by current harmonics, and notching caused by SCR switching. Display: One cycle of current and readings of true-rms current and fundamental frequency. Instantaneous current at cursor position. Application: Quickly recognising dominant load types in the circuit. Quickly identifying linear, mixed linear and non-linear loads, and phase-shifted motor loads. Display: Bar graph of dc voltage, fundamental voltage, and harmonics (up to 31st). Using cursor, view percent of fundamental (%F), percent of total rms (%R), rms value, frequency and phase angle of harmonic voltage. Application: Quickly identifying patterns of harmonic distortion, and likely sources of voltage harmonics. Display: %-fundamental or %-rms, rms value, frequency, and phase angle of fundamental or harmonic currents (up to 31st), as selected by cursor from bar graph. Application: Identifying sources of harmonic currents. Obtaining data for designing, specifying or sizing transformers, filters, etc. 3

Display: Rms, peak and dc components of measured current. Crest factor, peak/rms value, %THD of current referenced to fundamental (%THD-F), or total rms (%THD-R) of current. Application: Derating transformers. Checking SCR firing balance. Power measurement Display: Watts, Volt-Amps, power factor (total) and displacement power factor of fundamental of single-phase power. Application: Identifying displacement versus distortion power factor. Determining proper power-factor correction methods. Figure 3 A/V signatures Display: Fundamental frequency and active power. Instantaneous value of power over one cycle of voltage or current. Instantaneous power at cursor position. Application: Identifying peak power and positiveversus-negative power components. Display: %-fundamental of active power, active power, cos (ø), and phase angle between voltage and current at harmonic selected by cursor. Magnitude and polarity of power at each harmonic frequency. Application: Identifying direction of harmonic current flow. Current voltage signatures can be viewed by use of the A/V button. This enables a quick diagnosis of the type of harmonic distortion and the power factor, for instance the typical signatures in Figure 3 are interpreted as follows: 1. A linear load with no phase shift. 2. A linear load with phase shift. A narrow ellipsoid in this pattern usually does not mean there is a problem. For wider ellipsoids, check power factor (PF). If the ellipsoid is backwards (upper left to lower right), check that you have pointed the current probe in the right direction. 3. A non-linear load, usually resulting from pulse-type (switch mode) power supplies. 4. A non-linear load resulting from a 3-phase (six pulse) rectifier power supply. 5. A linear load that is 180 out of phase. A current probe pointed in the wrong direction or reversed polarity voltage leads can cause this indication. This incorrect alignment will also cause negative power readings. 6. A combination of harmonic content and phase shift of the fundamental frequency. 7. A pattern indicative of a phase controlled siliconcontrolled rectifier (SCR) power supply. 4

Extra features of the Fluke 41B The Fluke 41B has three additional text screens one each for voltage, current and power. These screens show the following additional data: Total harmonic voltage V HM Voltage crest factor Total harmonic voltage distortion (as % of the fundamental voltage) Total harmonic current A HM K factor, a transformer rating calculation for harmonics tolerance Total harmonic current distortion (as % of the fundamental voltage) kva reactive The phase angle by which current lags the voltage ( A lag). The Fluke 41B is also able to store up to eight complete sets of measurements in memory. Using the supplied opto-isolated RS-232 link the present screen can be sent to a printer (Epson FX of HP Thinkjet compatible). The Fluke 41B is also supplied with FlukeView software, which enables information from the model 41B to be input to a PC into a Windows environment. This enables reading to be archived, further analysis of the measurements and incorporation of survey information into documentation. Specifications Minimum input levels 5V rms (using VØ reference) or 1A rms (using AØ reference) Voltage (true rms) Input range 0.0 to 600.0V rms (ac + dc) 0.0V to ±933 peak Basic accuracy (fundamental, 5-65Hz): rms ±(0.3% + 2 digits) peak, dc ±(2% + 3 digits) Input impedance 1MΩ, balanced Crest factor >3.0 below 300V, 1.56 at 600V Current with mv/a input (true rms) Input range 1.00 to 1000A rms (ac + dc) 1.0 to ±2000A peak Basic accuracy (fundamental, 5-65Hz): rms ±(0.3% + 3 digits) + probe specs Crest factor >3.0 below 600A, 2.0 @ 1000A 80i-500s current probe (supplied) 1 to 20A ac ±(5% + 0.3A) 20 to 100A ac ±5% 100 to 500A ac ±2% Power (watts and volt-amps) with 1mV/A input Range 0 to 600kW (kva) average 0 to 2000 kw (kva) peak Basic accuracy (fundamental, 5Hz-65Hz): Active power ±(1% + 4 digits) + probe specs Harmonics accuracy (cursor data) Volts: Fundamental to 15th harmonic: Volts ± (1% + 2 digits) Phase ± 2 16th to 31st harmonic: Volts ±(2% + 3 digits) Phase ±10 Amps and Watts: Fundamental to 15th harmonic: Amps or Watts ± (2% + 3 digits) + probe specs 16th to 31st harmonic: Amps or Watts ± (3% + 4 digits) + probe specs Other measurement specifications Frequency 5.00Hz-99.9Hz ±0.3Hz Input bandwidth (-0.5dB) dc 5Hz to 2.1 KHz Crest factor (CF range) 1.00 to 5.00 Power factor (PF) 0.00 to 1.00 Displacement power factor 0.00 to 1.00 Phase measurement range -179 to 180 K-factor (KF) range (Model 41) 1.00 to 30.00 5

General specifications Size 9.2 3.9 2.5 inches (234 100 64mm) Weight 2.0 lb(1kg) Battery: Type 4 alkaline C cells ANSI/NEDA-14A IEC-LR14 (supplied) Life 24 hours minimum (continuous) Temperature: Operating 32 to 122 F (0 to 50 C) Storage -4 to 140 F (20 to 60 C) Temperature coefficient 0.1 specified accuracy per C (0 to 18 C, 28 to 50 C) Humidity: Operating 32 to 86 F (0 to 30 C) 90% 86 to 104 F (30 to 40 C) 75% 104 to 122 F (40 to 50 C)45% Storage 90% Altitude: Operating 15,000 feet (4.6km) Storage 40,000 feet (12km) Shock and vibration Per MIL-T-28800, class 3 Electromagnetic compatibility RF emissions EN 50081-1 commercial limits FCC Part 15 Class B VFG 243-1991 RF susceptibility EN 50082-2 Industrial limits Case Drip-proof and dust-proof Display Type Super twisted liquid crystal Contrast User-adjustable Backlight Yes Safety Designed for 600V measurements on industrial power distribution circuits Overload protection: Voltage or current probe input 600V maximum Surge protection 6kV per IEC 1010-1 Max. voltage isolation to earth 600V from any terminal Protection levels IEC 1010-1, Pollution Degree 2 Installation Category III, Material Group II, 600V Protection class Protection Class II as described in IEC 1010-1, Annex H Waveform memory (Model 41B only) Eight nonvolatile memories each store waveform data for both voltage and current inputs for later recall or sending to a computer. EIA-232-E (RS-232) Interface (Model 41B only) Optically isolated, 1.2, 9.6 or 19.2 k baud rate. Printer output in either Epson FX-80 of HP Thinkjet format. FlukeView Windows and DOS software provided. RS Components shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS Components negligence) which may result from the use of any information provided in RS technical literature. RS Components, PO Box 99, Corby, Northants, NN17 9RS Telephone: 01536 201234 An Electrocomponents Company RS Components 1998