An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

Similar documents
Mathematical Modeling of Ultrasonic Phased Array for Obstacle Location for Visually Impaired

A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer

Novel Imaging Techniques for Defects Characterisation in Phased Array Inspection

AN EMAT ARRAY FOR THE RAPID INSPECTION OF LARGE STRUCTURES USING GUIDED WAVES. Paul Wilcox 1, Mike Lowe 2

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

AIP (2015) 34. AIP ISBN

TOFD-Scan Imaging Based on Synthetic Aperture Focusing. Technique

Virtual ultrasound sources

High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure

Nondestructive Testing and Flaw Detection in Steel block Using extension of Split Spectrum Processing based on Chebyshev IIR filter

Reconfigurable Arrays for Portable Ultrasound

Full Polarimetric THz Imaging System in Comparison with Infrared Thermography

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

Reduction of Dispersive Wave Modes in Guided Wave Testing using Split-Spectrum Processing

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

15 th Asia Pacific Conference for Non-Destructive Testing (APCNDT2017), Singapore.

DEFECT SIZING IN PIPE USING AN ULTRASONIC GUIDED WAVE FOCUSING TECHNIQUE

A COMPARISON BETWEEN ASTM E588 AND SEP 1927 RELATING RESOLUTION LIMITS AT DETERMINATION OF THE PURITY GRADE

Optimized Semi-Flexible Matrix Array Probes for Large Rotor Shafts and DGS Sizing Diagram Simulation Tool

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors

Data set reduction for ultrasonic TFM imaging using the effective aperture approach and virtual sources

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

Phased Array Inspection of Coarse Grain Welds (Austenitic, CRA, etc)

On Determination of Focal Laws for Linear Phased Array Probes as to the Active and Passive Element Size

DESIGN & VALIDATION OF A SEMI-FLEXIBLE PAUT PROBE FOR THE MANUFACTURING INSPECTIONS OF LARGE FORGED ROTORS

The Application of TOFD Technique on the Large Pressure Vessel

Further Developments in Ultrasonic Phased Array Inspection of Aging Aircraft

1112. Dimensional evaluation of metal discontinuities by geometrical parameters of their patterns on imaging flaw detector monitor

Long Range Guided Wave Monitoring of Rail Track

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Exercise 2: Simulation of ultrasound field using Field II

Imaging System for Non-Destructive Testing of Glass Fibre Reinforced Plastics Martin NEZADAL 1,2, Jan SCHÜR 1, Lorenz-Peter SCHMIDT 1

PLANAR BEAM-FORMING ARRAY FOR BROADBAND COMMUNICATION IN THE 60 GHZ BAND

REAL-TIME B-SCAN ULTRASONIC IMAGING USING A DIGITAL PHASED. Robert Dunki-Jacobs and Lewis Thomas General Electric Company Schenectady, New York, 12301

ENHANCEMENT OF PHASED ARRAY SIZE AND RADIATION PROPERTIES USING STAGGERED ARRAY CONFIGURATIONS

3. Ultrasound Imaging(2)

Multi-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays

Electromagnetic Array Imaging of Steel Bars in Concrete Using High-Speed SAFT

Developments in Ultrasonic Phased Array Inspection I

Random Thinning of Segmented Annular Arrrays

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

SIMULATION OF B-SCAN IMAGES FROM TWO-DIMENSIONAL TRANSDUCER ARRAYS: PART II - COMPARISONS BETWEEN LINEAR AND TWO-DIMENSIONALPHASED ARRAYS

Ultrasound Nondestructive Evaluation (NDE) Imaging with Transducer Arrays and Adaptive Processing

Guided Wave Travel Time Tomography for Bends

Developments in Ultrasonic Phased Array Inspection III

Linear arrays used in ultrasonic evaluation

Further development of synthetic aperture real-time 3D scanning with a rotating phased array

Adaptive Ultrasound Technology for the Inspection of Variable Geometry Composite Material. Presenter Etienne Grondin Olympus NDT Canada, Quebec

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

Extending Acoustic Microscopy for Comprehensive Failure Analysis Applications

Available online at ScienceDirect. Physics Procedia 70 (2015 )

Manual UT vs PIMS (Permanently installed monitoring sensors)

LOS 1 LASER OPTICS SET

Effect of coupling conditions on ultrasonic echo parameters

Ultrasonic Air-Coupled Non-Destructive Testing of Aerospace Components

NDT-PRO Services expands service offering

Ultrasound Redefined. Ultrasonic Transducers

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Advanced Ultrasonic Imaging for Automotive Spot Weld Quality Testing

Detection of fibre waviness using ultrasonic array scattering data

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to publication record in Explore Bristol Research PDF-document

Operation and Sound Field of an Ultrasonic Biplane-Array

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Multi-spectral acoustical imaging

Ultrasonic Guided Wave Testing of Cylindrical Bars

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

ULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE

NOVEL ACOUSTIC EMISSION SOURCE LOCATION

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Developments in Ultrasonic Guided Wave Inspection

High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz

RapidScan II Application Note General Composite Scanning

Hybrid Passive/Active Impact Detection & Localization for Aerospace Structures Seth S. Kessler and Eric B. Flynn. Metis Design Corporation

Latest Developments for Pipeline Girth Welds using 3D Imaging Techniques. Novel Construction Meeting Jan van der Ent March 2016, Geneva

A New Elastic-wave-based NDT System for Imaging Defects inside Concrete Structures

A PHASED ARRAY ULTRASONIC TESTING OF A MANUAL THICK AUSTENITIC WELD FEEDBACK

Basic functions of the universal flaw detector GEKKO

Effects on phased arrays radiation pattern due to phase error distribution in the phase shifter operation

Curved arrays for improved horizontal sizing in small pipe welds

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Transcription:

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array S. Mondal London South Bank University; School of Engineering 103 Borough Road, London SE1 0AA More info about this article: http://www.ndt.net/?id=19093 Abstract The report presents an algorithm called the total focusing method for the circular phased array. It shows an improvement in the focusing for the main lobe beam and eliminates the effects of the side lobe. The report visualizes the effects for different ring sizes of the circular array and the effect of different numbers of array elements. The results of this modelling indicate that, for a given number of elements, placing them around the circular ring allow them to perform best and that the element spacing should be less than half a wavelength to avoid grating lobes and to eliminate grating lobes. In addition to that it describes how the TFM images have been built by computing half time traces of the transmitter and receiver array. Keywords: Phased array, ultrasonic beam focusing and total focusing method 1. Introduction The phased array technology is now a popular technique in the field of NDT inspections where a complex geometry is involved. The main advantages of the phased array system are of its beam steering and focusing capabilities which allows geometry to inspect areas where physical access is not possible. In recent years phased array technology has enhanced the way in which engineers evaluate components for their structural safety and protection, introducing a new form of inspection known today as phased array NDT non-destructive testing. Application of phased arrays (PA) can vary from pressure vessel testing, aerospace and nuclear power plants and further to the medical field where its application was initially implemented. The early 1970 s saw the use of a PA system confined to the medical field, later introduced in the industrial industry in the 1980 s, but because of varying acoustic properties, complex component geometries and ranges in material thicknesses found in industrial testing, application of PA in this field presented a greater challenge [1,2]. Due to the amount of possible element configurations experiments concluded by [6], demonstrated the effects of three different geometrical selections of elements. The visual response of the circular array designs showed the best performance in terms of beam directivity not only this, by increasing the number of elements decreases the amplitude of the grating lobes and proved to be more superior in terms of obtaining the lowest array performance indicator (API) values. In the journal published by [4], the spherical-section produced a much higher focal intensity gain and the amplitude of the grating lobes with respect to the focus was lower when compared to planar geometries. Another method of beam focusing analysed the beam directivity and the pressure distribution to predict the behaviours of focusing oppose to steering. A numerical simulation was utilised to show some key effects of focusing within and beyond the transition range. L.Azar, Y. Shi and S-C Wooh [3] demonstrated a focusing method which involved a parabolic time delay; taken from the Huygens principle; propagating waves are focused to a specific point within a material where all the individual

wave fronts are summed up therefore producing maximum focal beam intensity along any desired direction. 1.1 Simulation of array data The arrays are compared by simulating the response to a point reflector that can be located anywhere in the +z halfspace, as indicated in Figure 1. To do this time domain signals (timetraces) are simulated for every transmitter-receiver combination. For example, if n is the number of elements in the array then a maximum of n x n possible time-traces are available for all transmitter-receiver combinations. However, the number of independent time-traces n that actually need to be computed for the simulation is only n 1, because the time-trace 2 when element 1 transmits to element 2 is identical to the time-trace when element 2 transmits to element 1 due to reciprocity. The mathematical details of the circular phased array, in term of the time traces of the transmitting and receiving signal, and frequency responses analysis is described in the journal paper [6]. Array element (x n, y n ) x ref r y ref X Y Z d z ref (x ref, y ref, z ref ) Point reflector Figure 1 : Array elements are uniformly spaced on the circumference of a circle of radius, r, in the x-y plane and a point reflector is in the x-y-z plane. 1.2 Total focusing method (TFM) imaging The synthetic aperture focusing technique (SAFT) uses only the pulse echo responses of the array so that it does not take advantage of the much larger number of responses for various pairs of elements that can be recorded with an array. The total focusing method does utilize all combinations of sending and receiving elements, also called full matrix capture, to from an image [5]. The formation of a TFM image with a circular array (Figure 1) with N elements. In this case, it has been recorded all the voltage time domain signals V(X tn, X rm,t), (n= 1..N),(m= 1 N),

for sending element whose centroid is located at X tn and a receiving element whose centroid is at X rm. In the image formation process a grid of image points has been setup as shown in Figure 2, advance all these sending/receiving element pair responses by the travel times T(Xtn,Y) +T(Xrm,Y) and then calculate their sum at time t =0 to form an image, I TFM (Y), giving Transforming the measured time domain signals to the frequency domain and evaluate at M positive frequencies, as in the SAFT method, the alternate frequency domain TFM form: Circular array probe T(X tn, Y) T(X rm, Y) Focus point Y Figure 2: Imaging algorithms for the TFM scan 2 Fundamental of the TFM mapping In the TFM mapping, each input (x, y) and output value (z) from the function corresponds to a point on a grid, the images are created corresponding to the colours on the colour bar, the lowest point is represented as dark blue; the highest point is represented as red.

Figure 3.1: Grid representation of beam In phased array simulation; the point representing the strongest focus of the beam are displayed on a grid like image as shown in Figure3.1; only the colours showing the strongest (deep red) and weakest points (dark blue) which are also demonstrated on the grid as 0 and 1 are displayed at the point above the threshold (cut-off point) removing all remaining colours in-between. 2.1 Results and Discussion For a circular array the characteristics of the main lobe, side lobes and grating lobes are governed by geometrical parameters such as ring size, inter-element spacing, and number of elements. The effect of varying these geometrical parameters is shown in Figures 4(a)-(c) and Figures 5(a)-(c). Figures 4(a)-(c) demonstrate the effect of varying ring diameter while the number of elements is kept constant and equal to eight. In Figure 4(a) the ring diameter is 1.67 and the space between elements is /2. The result shows that there are no side or grating lobes but that the main lobe width is large. In Figure 4(b) and Figure 4(c) the ring size is increased to 3.33 and 5 respectively. The main beam lobe width is decreased but there are indications of grating lobes due to the space between elements being greater than /2. In Figures 5(a)-(c) the number of elements is increased in a circular array with a fixed diameter of 5. The figures show that as the number of elements increases the amplitude of the grating lobes decreases. In Figure 5(c) there are no side lobes because for 32 elements, the inter-element spacing is less than /2 in a 5 diameter ring..

(a) (b) (c) Figure 4 : Effect of ring size on side lobes and main beam width for an 8 element circular array transducer: (a) ring size 1.67 (b) ring size 3.33 ; (c) ring size 5 The scales shown to right of each image are in db. (a) (b) Total elements 4 (c) Figure 5: Effect of number of elements on side lobes when the diameter of the circular array is 5 (a) 4 elements; (b) 8 elements; (c) 32 elements. The scales shown to right of each image are in db.

3. Conclusions The parameters that determine the outcome in the scanned image include the used frequency, propagation material, strength of the main lobe, transducer properties and electrical networks. It is important that for these to be carefully considered in hopes of achieving the best image resolution; an ideal outcome would show a narrowly focused, high intensity beam with minimal unwanted defects in the image such as grating and side lobes. These are unwanted abnormalities that occur in the scanned image reducing the focus of the main beam; parameters that are involved with side lobes include element configuration, frequency, the element size; number, pitch and spacing as well as the bandwidth. Grating lobes occur when the element size is equal or greater than the wavelength but no longer visible when the size is less than half a wavelength. To spot such abnormalities, concentration of the main-lobe; together with increasing intensity range of the near field delivering maximum penetration of usable focus for a given array, needs to be improved to allow greater detection. References [1] Yen, J.T., and Smith, S.W., 2002, Real Time Rectilinear Volumetric Imaging, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 49, no. 1, pp. 114-124. [2] Mendelsohn,Y., and Wiener-Avnear, E., 2002, Simulations of Circular 2D Phase-Array Ultrasonic Imaging Transducers, Ultrasonics, 39, pp. 657-666. [3] Azar, L., Shi, Y. and Wooh, S. (2000). Beam focusing behavior of linear phased arrays. NDT & E International, 33(3), pp.189-198. [4] Ebbini, E. and Cain, C. (1991). A spherical-section ultrasound phased array applicator for deep localized hyperthermia. IEEE Transactions on Biomedical Engineering, 38(7), pp.634-643. [5] Holmes, C., Drinkwater, B. and Wilcox, P. (2005). Post-processing of ultrasonic phased array data for optimal performance. Insight Non-Destructive Testing and Condition Monitoring, 47(2), pp.88-90. [6] Mondal, S., Wilcox, P. and Drinkwater, B. (2005). Design of Two-Dimensional Ultrasonic Phased Array Transducers. J. Pressure Vessel Technol., 127(3), [7] Daniel, H.T., and Stuart, F., 1991, Beam Steering with Pulsed 2D Transducer Arrays, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 39, no. 4, pp. 464-475. [8] Wooh, S.C., and Yijun, S., 1999 Optimum Beam Steering of Linear Phased Arrays, Wave Motion, 29, pp. 245 265.