Analog Technologies. Multimeter 115C and 117C

Similar documents
114, 115, and 117. True-rms Multimeters. Users Manual

True-rms Multimeter. Users Manual

Electrical Multimeter

Analog Technologies. Multimeter 15B and17b

114, 115, and 117. True-rms Multimeters

Electrical Multimeter

True-rms Multimeter. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

Model 77 Series IV. Digital Multimeter. Users Manual

Models 110, 111 & 112

79/26 Series III Multimeter

n/a FLUKE 116 MULTIMETER

175, 177, 179. True-rms Multimeters. Users Manual

1507/1503. Insulation Testers. Users Manual

15B & 17B. Users Manual. Multimeters

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Analog Technologies VC99. Multimeter FEATURES

15B & 17B. Multimeters. Users Manual

USER'S MANUAL DMR-6700

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Model 77 Series IV. Digital Multimeter. Users Manual

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

User Manual Digital Multimeter. model no.: MSR-U1000

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

DM-45 Digital Multimeter

Model 77 Series IV. Digital Multimeter. Users Manual

200Amp AC Clamp Meter + NCV Model MA250

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Analog Technologies. Multimeter DM4070

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

374/375/376 Clamp Meter. Users Manual

Handheld Digital Multimeter PRO-50A

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Autoranging Multimeter Extech EX503

netzerotools.com 374/375/376 Users Manual Clamp Meter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

12B/18 MultiMeter Instruction Sheet

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

User Manual. All rights reserved. Specifications are subject to change without notice.

User s Guide. 400A AC/DC Clamp Meter. Model MA220

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

600A Clamp Meters w/tightsight Display

DCM730. Digital Clamp Meter User s Manual

374/375/376 Clamp Meter

User Manual Digital Clamp Multimeter. model no.: MSR-C600

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DVM1190 DIGITAL MULTIMETER

400Amp True RMS AC Clamp Meter + NCV

374/375/376 Clamp Meter

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

True-rms Remote Display Digital Multimeter. Users Manual

MW3105 DIGITAL CLAMP MULTIMETER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Sales: Technical: Fax:

374/375/376 Clamp Meter

1.General instructions Specifications Description...7

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

CONTENTS MS2033A. 1.Introduction Safety Information...01

902 FC. HVAC True-rms Clamp Meter

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

KMD-S04 Multímetro de bolsillo

312, 316, 318. Clamp Meter. Users Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

AX-C Introduction. 2. Safety Information

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

DMM8900 SERIES USERS MANUAL

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

IDM 98-III & IDM 99-III Digital Multimeters

Digital Clamp Meter Model: &

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Dawson DDM190. Digital Multimeter User s Manual

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

1587/1577. Insulation Multimeters. Users Manual

User Manual Digital Multimeter

User Guide. Digital AC/DC Clamp Meter Model 38394

Users Manual. Introduction. ProcessMeter. Warning. Read Safety Information before you use the Meter.

MS2030 CAT III 600 V A V AUTO RS232

Transcription:

Figure 1. The Photo of Actual 117C Figure 2. The Photo of Actual 117C Figure 3. The Photo of Actual 117C FEATURES Digital display: 6000 counts, updates 4/sec Bar graph: 33 segments, updates 32/sec Operating temperature: -10 to +50 Storage temperature: -40 to +60 Operating altitude: 2000 meters APPLICATIONS It s widely used to measure AC, DC, direct voltage, alternating voltage, resistance, etc. DESCRIPTION are battery powered, true-rms multimeters with a 6000-count display and a bar graph. meet CAT Ⅲ IEC 61010-1 2 nd Edition safety standards. The IEC 61010-1 2 nd Edition safety standard defines four measurement categories (CAT to IV) based on the magnitude of danger from transient impulses. CAT Ⅲ meters are designed to protect against transients in fixed-equipment installations at the distribution level. SAFETY INFORMATION Warning: statement identifies hazardous conditions and actions that could cause bodily harm or death. Caution: statement indentifies conditions and actions that could damage the meter or equipment under test. To avoid possible electric shock or personal injury, follow these guidelines: Use the meter only as specified in this datasheet or the protection provided by the meter might be impaired. Do not use the meter or test leads if they appear damaged, or the meter is not operating properly. Always use proper terminals, switch position, and range for measurements. Verify the meter s operation by measuring a known voltage. If in doubt, have the meter serviced. Do not apply more than the rated voltage, as marked on meter, between terminals or between any terminal and earth ground. Use caution with voltages above 30V AC rms, 42V AC peak, or 60V DC. These voltages pose a shock hazard. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes or capacitance. Do not use the meter around explosive gas or vapor. When using test leads or probes, keep your fingers behind the finger guards. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 1

Only use test leads that have the same voltage, category and amperage ratings as the meter and that have been approved by a safety agency. Remove test leads from meter before opening the battery door or meter case. Check the test leads for continuity before use. Do not use if the readings are high or noisy. Table 1. Symbol Comply with local and national safety requirements when working in hazardous locations. Use only the replacement fuse specified or the protection may be impaired. Do not use the Auto Volts function to measure voltage in circuits that could be damaged by this function s low input impedance ( 3kΩ) (117 only). ~ AC (Alternating Current) Fuse Table 2. Display DC (Direct Current) Hazardous voltage Battery (Low battery when shown on the display) Do not dispose of this product as unsorted municipal waste. Double insulated Important information; refer to datasheet Earth ground AC and DC No. Symbol Description Model 1 Volt Alert The meter is in the VoltAlert TM non-contact voltage detect mode. 117C 2 The meter function is set to Continuity. 3 The meter function is set to Diode Test. 4 - Input is a negative value. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 2

5 Unsafe voltage. Measured input voltage 30V, or voltage overload condition (OL). Display hold enabled. Display freezes present reading. 6 HOLD 7 MIN MAX MAX MIN AVG MIN MAX AVG mode enabled. Maximum, minimum, average or present reading displayed. 8 ( Red LED) Voltage presence through the non-contact VoltAlert sensor 9 LoZ The meter is measuring voltage or capacitance with low input impedance. 10 nμf mvμa MkΩ khz Measurement units. 11 DC AC Direct current or alternating current 117C 12 Battery low warning 13 610000 mv Indicate the meter s range selection 14 (Bar graph) Analog display 15 Auto Volts The meter is in the Auto Volts function. Auto Auto ranging. The meter selects the range for best resolution. Manual Manual ranging. User sets the meter s range. 16 + Bar graph polarity 117C 17 The input is too large for the selected range. 18 Table 3. Terminals Test lead alert. Briefly displayed whenever the meter s function switch is rotated to or from any A position. No. Description Model 1 Input terminal for measuring AC and DC current to 10A Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 3

2 Common (return) terminal for all measurements 3 Table 4. Error Messages Input terminal for measuring voltage, continuity, resistance, capacitance, frequency and testing diodes. Battery must be replaced before the meter will operate. Calibration required. Meter calibration is required before the meter will operate. Internal error. The meter must be repaired before it will operate. Internal error. The meter must be repaired before it will operate. Table 5. Rotary Switch Positions Switch Position Measurement Function Model AUTO-V LoZ Hz (button) Automatically selects AC or DC volts based on the sensed input with a low impedance input. AC voltages from 0.06mV to 600V. Frequency from 5Hz to 50kHz. DC voltage from 0.001V to 600V AC voltage from 6.0mV to 600mV, DC-coupled. DC voltage from 0.1 to 600mV. 117C Ω Ohms from 0.1Ω to 40MΩ. Hz (button) Volt Alert Continuity beeper turns on at <20Ω and turns off at >250Ω. Diode test. Display OL above 2.0V. Farad from 1nF to 9999μF. AC current from 0.1 to 10A (>10 to 20A, 30 seconds on, 10 minutes off). >10.00A display flashes. >20A, OL is displayed. DC-coupled. Frequency from 45Hz to 5kHz. DC current from 0.001A to 10A (>10 to 20A, 30 seconds on, 10 minutes off). >10.00A display flashes. >20A, OL is displayed. Non-contact sensing of AC voltage. Note: All AC functions and Auto-V LoZ are true-rms. AC voltage is AC-coupled. Auto-V LoZ, AC mv and AC amps are DC coupled. SPECIFICATIONS Table 6. General Specification Display Surge protection Fuse for A input Digital display: 6000 counts, updates 4/sec Bar graph: 33 segments, updates 32/sec 6kV peak per IEC 61010-1 600V CAT Ⅲ Pollution degree 2 11A, 1000V 17kA FAST Fuse 117C Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 4

Operating temperature -10 to +50 Storage temperature -40 to +60 Temperature coefficient 0.1 (specified accuracy)/ (<18 or >28 ) Operating altitude Maximum voltage between any terminal and earth ground Table 7. Accuracy Battery Battery life Safety compliances 2000meters 600V 9 volt Alkaline, NEDA 1604A/IEC 6LR61 Alkaline: 400hours typical, without backlight Comply with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA- C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2 nd Edition for measurement Category Ⅲ, 600V, Pollution degree 2, EMC EN61326-1 Certifications UL,, CSA,, (N10140), VDE IP Rating (dust and water protection) IP42 Function Range Resolution Accuracy ± ([% of Reading]+[Counts]) Model DC millivolts 600.0mV 0.1mV 0.5%+2 115C, 117C DC volts 6.000V 60.00V 600.0V 0.001V 0.01V 0.1V DC, 45 to 500Hz 0.5%+2 115C, 117C 500Hz to 1kHz Auto-V LoZ [1] True-rms 600.0V 0.1V 2.0%+3 4.4.0%+3 117C 45 to 500Hz 500Hz to 1kHz AC millivolts [1] True-rms 600.0mV 0.1mV 1.0%+3 2.0%+3 115C, 117C AC Volts [1] True-rms 6.000V 60.00V 600.0V 0.001V 0.01V 0.1V Continuity 600Ω 1Ω Ohms 600.0Ω 6.000kΩ 60.00kΩ 600.0kΩ 6.000MΩ 40.00MΩ 0.1Ω 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ 0.01MΩ 1.0%+3 2.0%+3 115C, 117C Beeper on<20ω, off>250ω; detects opens or shorts of 500μs or longer. 0.9%+2 0.9%+1 0.9%+1 0.9%+1 0.9%+1 5%+2 115C, 117C 115C, 117C Diode test 2.000V 0.001V 0.9%+2 115C, 117C Capacitance 1000nF 10.00μF 1nF 0.01μF 1.9%+2 1.9%+2 115C, 117C Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 5

Lo-Z Capacitance (power-up option) AC Amps true-rms [1] (45 Hz to 500Hz) DC Amps Hz (V or A input) [2] 100.0μF 9999μF 6.000A 10.00A [3] 20A for 30 seconds max., 10 minutes test min. 6.000A 10.00A [3] 20A for 30 seconds max., 10minutes rest min. 99.99Hz 999.9Hz 9.999kHz 50.00kHz 0.1μF 1μF 1.9%+2 100μF-1000μF: 1.9%+2 >1000μF:5%+20 1nF to 500μF 10%+2 typical 115C, 117C 0.001A 0.01A 0.001A 0.01A 0.01Hz 0.1Hz 0.001kHz 0.01kHz 1.5%+3 115C, 117C 1.0%+3 115C, 117C 0.1%+2 115C, 117C Notes: [1] All AC ranges expect Auto-V LoZ are specified from 1% to 100% of range. Auto-V LoZ is specified from 0.0V. Because inputs below 1% of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3. AC volts is AC-coupled. Auto-V LoZ, AC mv and AC amps are DC-coupled. [2] AC Volts Hz is AC-coupled and specified from 5Hz to 50kHz. AC Amps HZ is DC-coupled and specified from 45Hz to 5kHz. [3] >10A unspecified. Table 8. Input Characteristics Function Input Impedance (Nominal) Common Mode Rejection Ratio (1kΩ unbalanced) Volts AC >5MΩ <100pF >60dB at DC, 50 or 60Hz Normal Mode Rejection Volts DC >10MΩ <100pF >100dB at DC, 50 or 60Hz >60dB at 50 or 60Hz Auto-V LoZ ~3kΩ <500pF >60dB at DC, 50 or 60Hz Ohms Open Circuit Test Voltage Full Scale Voltage Short Circuit Current <2.7V DC To 6.0MΩ <0.7V DC 40MΩ <0.9V DC <350μA Diode Test <2.7V DC 2.000V DC <1.2mA Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 6

BATTERY SAVER ( SLEEP MODE ) The meter automatically enters sleep mode and blanks the display if there is no function change, range change, or button press for 20 minutes. Pressing any button or turning the rotary switch awakens the meter. To disable the sleep mode, hold down the button turning the meter on. The sleep mode is always disabled in the MIN MAX AVG mode. MIN MAX AVG RECORDING MODE The MIN MAX AVG recording mode captures the minimum and maximum input values (ignoring overloads), and calculates a running average of all readings. When a new high or low is detected, the meter beeps. Put the meter in the desired measurement function and range. Press MIN MAX to enter MIN MAX AVG mode. MIN MAX and MAX are displayed and the highest reading detected since entering MIN MAX AVG is displayed. Press MIN MAX to step through the low (MIN), average (AVG) and present readings. To pause MIN MAX AVG recording without erasing stored values, press HOLD. HOLD is displayed. To resume MIN MAX AVG recording, press HOLD again. To exit and erase stored readings, press MIN MAX for at least one second or turn the rotary switch. DISPLAY HOLD Warning To avoid electric shock, when DISPLAY HOLD is activated, be aware that the display will not change when you apply a different voltage. In the DISPLAY HOLD mode, the meter freezes the display. 1. Press HOLD to activate DISPLAY HOLD. ( HOLD is displayed) 2. To exit and return to normal operation, press HOLD or turn the rotary switch. BACKLIGHT Press to toggle the backlight on and off. The backlight automatically turns off after 40 seconds. To disable backlight auto-off, hold down while turning the meter on. MANUAL AND AUTO RANGE The meter has both manual and auto range modes. In the auto range mode, the meter selects the range with the best resolution. In the manual range mode, you override auto range and select the range yourself. When you turn the meter on, it defaults to auto range and Auto is displayed. 1. To enter the Manual Range mode, press Manual is displayed. 2. In the Manual Range mode, press RANGE to increment the range. After the highest range, the meter wraps to the lowest range. Note You cannot manually change the range in the MIN MAX AVG or Display HOLD modes. If you press while in MIN MAX AVG or Display Hold, the meter beeps twice, indicating an invalid operation and the range does not change. 3. To exit Manual Range, press for at least 1 second or turn the rotary switch. The meter returns to Auto Range and Auto is displayed. POWER-UP OPTIONS To select a power-up Option, hold down the button indicated in the following table while turning the meter on. Power-Up Options are canceled when you turn the meter off and when sleep mode is activated. Table 9. Button Power-Up Options HOLD Turns on all display segments. MIN MAX Disables beeper. is displayed when enabled. RANGE Enables low impedance capacitance measurements. Disables automatic power-down ( Sleep mode ). is displayed when enabled. is displayed when enabled. Disables auto backlight off. is displayed when enabled. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 7

MAKING BASIC MEASUREMENTS When connecting the test leads to the circuit or device, connect the common (COM) test lead before connecting the live lead; when removing test leads, remove the live lead before removing the common test lead. Measuring Resistance Measuring AC and DC Voltage Figure 4. Measuring Resistance Warning To avoid electric shock, injury or damage to the meter, disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes or capacitance. Testing for Continuity Figure 6. Measuring AC and DC Voltage Using Auto volts selection (117C only) With the function switch in the position, the meter automatically selects a DC o AC voltage measurement based on the input applied between the V and COM jacks. This function also sets the meter s input impedance to approximately 3kΩ to reduce the possibility of false readings due to ghost voltages. Measuring AC and DC Millivolts Figure 5. Testing for Continuity Note The continuity function works best as a fast, convenient method to check for opens and shorts. For maximum accuracy in making resistance measurements, use the meter s resistance (Ω) function. Figure 7. Measuring AC and DC Millivolts with the function switch in the position, the meter measures AC plus DC millivolts. Press to switch the meter to DC millivolts. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 8

Measuring AC or DC Current The millivolt and voltage function of the meter can be used with an optional mv/a output Current Probe to measure currents that exceed the rating of the meter. Measuring Capacitance Figure 8. Measuring AC or DC Current Turn circuit power off, break the circuit, insert the meter in series with the circuit and then turn circuit power on. Warning To avoid personal injury or damage to the meter: Never attempt to make an in-circuit current measurement when the open circuit potential to earth is >600V. Check the meter s fuse before testing. (See Testing the Fuse) Use the proper terminals, switch position and range for your measurement. Never place the probes in parallel with a circuit or component when the leads are plugged into the A (Amps) terminals. Measuring Current above 10 Amps Figure 10. Measuring Capacitance Measuring Frequency Warning To avoid electrical shock, disregard the bar graph for frequencies>1 khz. If the frequency of the measured signal is >1 khz, the bar graph and are unspecified. AC Voltage Frequency AC Current Frequency Figure 9. Measuring Current above 10 Amps Figure 11. Measuring Frequency The meter measures the frequency of a signal by counting the number of times the signal crosses a trigger level each second. The trigger level is 0V, 0A for all ranges. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 9

Press to turn the frequency measurement function on and off. Frequency works with AC functions only. Select progressively lower ranges using manual ranging for a stable reading. Detecting AC Voltage Presence (117C only) Figure 12. Detecting AC Voltage Presence (117C only) To detect the presence of AC voltage, place the top of the meter close to a conductor. The meter gives an audible as well as visual indication when voltage is detected. There are two sensitivity settings. The setting can be used on flush mounted wall sockets, power strips, flush mounted industrial outlets and various power cords. The H 1 setting allows for AC voltage detection on other styles of recessed power connectors or sockets where the actual AC voltage is recessed within the connector itself. The VoltAlert detector works in bare wire applications with voltages as low as 24V in the H 1 setting. Warning I there is no indication, voltage could still be present. Do not rely on the VoltAlert detector with shielded wire. Operation may be effected by differences in socket design, insulation thickness and type. Making Low Impedance Capacitance Measurements For making capacitance measurements on cables with ghost voltage, hold while turning on the meter to switch the meter into, (low input impedance) Capacitance mode. In this mode, capacitance measurements will have a lower accuracy and lower dynamic range. This setting is not saved when the meter is turned off or goes into sleep mode. Testing Diodes Good Diode Open Good Diode Shorted Figure 13. Testing Diodes Using the Bar Graph Single Beep The Forward bar graph Bias is like the needle Reverse on an Bias analog meter. It has an overload Badindicator Diode ( ) to the right Badand Diode a polarity indicator (+) to the left. Because the bar graph is much faster than the digital display, the bar graph is useful for making peak and null adjustment. The bar graph is disabled when measuring capacitance. In frequency, the bar graph and range annunciator indicates the underlying voltage or current up to 1 khz. The number of segments indicates the measured value and is relative to the full-scale value of the selected range. In the 60V range, for example (see figure 14), the major divisions on the scale represent 0, 15, 30, 45 and 60V. An input of -30V turns on the negative sign and the segments up to the middle of the scale. and Test the Fuse Figure 14. Using the Bar Graph Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 10

To open the case for fuse replacement: 1. Remove the test leads from the meter. 2. Remove the meter from its holster. 3. Remove two screws from the case bottom. 4. Separate the case bottom from the case top. 5. Remove the fuse from the holder and replace it with an 11A, 1000V, FAST fuse having a minimum interrupt rating of 17, 000A. 6. To re-assemble the meter, first attach the case bottom to the case top, and then install the two screws. Finally, inset the meter into its holster. Figure 15. Test the Fuse MAINTENANCE Maintenance of the meter consists of battery and fuse replacement, as well as case cleaning. REPLACE THE BATTERY AND FUSE Warning To avoid shock, injury or damage to the meter: Remove test leads from the meter before opening the case or battery door. Use ONLY a fuse with the amperage, interrupt voltage and speed ratings specified. To remove the battery door for battery replacement: 1. Remove the test leads from the meter. 2. Remove the battery door screw. 3. Use the finger recess to lift the door slightly. 4. Lift the door straight up to separate it from the case. The battery fits inside the battery door, which is then inserted into the case, bottom edge first, until it is fully seated. Do not attempt to install the battery directly into the case. 5. Install and tighten battery door screw. Figure 16. Replace the Fuse Cleaning Wipe the case with a damp cloth and mild detergent. Do not use abrasives, isopropyl alcohol or solvents to clean the case or lens /window. Dirt or moisture in the terminals can affect readings. ORDERING INFORMATION Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 11

Table 10. Unit Price Part# Unit Price 115C $ 117C $197.99 NOTICE 1. ATI reserves the right to make changes to its products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. 2. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, patent infringement, and limitation of liability. Testing and other quality control techniques are utilized to the extent ATI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. 3. Customers are responsible for their applications using ATI components. In order to minimize risks associated with the customers applications, adequate design and operating safeguards must be provided by the customers to minimize inherent or procedural hazards. ATI assumes no liability for applications assistance or customer product design. 4. ATI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of ATI covering or relating to any combination, machine, or process in which such products or services might be or are used. ATI s publication of information regarding any third party s products or services does not constitute ATI s approval, warranty or endorsement thereof. 5. IP (Intellectual Property) Ownership: ATI retains the ownership of full rights for special technologies and/or techniques embedded in its products, the designs for mechanics, optics, plus all modifications, improvements, and inventions made by ATI for its products and/or projects. Copyrights 2000 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 12