Synergy NEO HTS Multi-Mode Microplate Reader

Similar documents
SpectraMax i3x Multi-Mode Detection Platform. Explore a wealth of applications in one future-ready system

Perkin Elmer Envision 2100 Multilabel Reader

Microplate Reader EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Implementation of HTRF. technology on the Spark. multimode reader SENSITIVE, FAST AND RELIABLE MEASUREMENT OF HIGH-THROUGHPUT SCREENING ASSAYS

Reference manual. EnVision. Software version 1.12

Operating Manual Revision B

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

Revision K 1/ B0001K

SpectraMax M3, M4, M5, and M5 e Multi-Mode Microplate Readers. User Guide

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

Content Spectrophotometers

THE ULTIMATE DOCUMENT EXAMINATION SYSTEM STATE-OF-THE-ART SPECTRAL ANALYSIS FORENSIC LABS SECURITY PRINTERS IMMIGRATION AUTHORITIES

1/8 m GRATING MONOCHROMATOR

UVISEL 2. Interface. Thickness. Refractive index. Roughness. Extinction coefficient. Scientific Ellipsometric Platform

mos-500 SPECTROPOLARIMETER Circular Dichroism Spectrometer Everything you expect from a spectropolarimeter

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

SpectraPro 2150 Monochromators and Spectrographs

MICRO SPECTRAL SCANNER

SpectraMax. M2/M2 e user guide A MULTI-DETECTION MICROPLATE READER WITH TWO-MODE CUVETTE PORT

Joliot Type Spectrometer. photosynthesis system JTS-10. A LED pump-probe spectrometer

Single Photon! Sensitivity

FS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

FS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements

Nano-100 Spectrophotometer. Brief introduction

SPECTROLABLAVM11. Performance Meets Flexibility: The Best in Metal Analysis

BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

FluorChem M MultiFluor System

Thermo Scientific Varioskan Flash User Manual

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Optional AR coating and wedge windows are available

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol

FT-IR.

Spark Spectral Sensor Offers Advantages

Features. Applications. Optional Features

TECAN. i-control. Instructions for Use for. Document Part No.: Document Version No.: 1.6 Software Version No.: 1.

Visible & UV/Vis Spectrophotometers

Hitachi Fluorescence Spectrophotometer

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Improving the Collection Efficiency of Raman Scattering

Tunable KiloArc. Tunable Broadband Light Source.

Non-Descanned FLIM Detection in Multiphoton Microscopes

SpectraMax GEMINI EM. Dual-Scanning Microplate Spectrofluorometer Operator s Manual Orleans Drive Sunnyvale, California 94089

Spotlight 150 and 200 FT-IR Microscopy Systems

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

Experimental Analysis of Luminescence in Printed Materials

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

LAMBDA 800 UV/VIS and 900 UV/VIS/NIR Spectrophotometer Systems

DCS laser for Thomson scattering diagnostic applications

MS260i 1/4 M IMAGING SPECTROGRAPHS

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

Automated Washing of Magnetic Bead QuantiGene Plex 2.0 Assays

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

INDUSTRIAL SCANNERS AND SYSTEMS

ImageXpress Micro XLS Widefield High Content Screening System. Imaging with a vision.

SmartDoc 2.0 E5001-SDB Instruction Manual

Průtokový cytometr CytoFLEX

IN Cell Analyzer 6500HS

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

The Versatile and Powerful ACLxy. ACLxy

Nicolet Evolution 500. UV-Visible Spectrophotometer

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT

Lasers for Life Sciences

Spectrophotometer CM-3630 PaperControl Software

Lanthanide-based Up-conversion Materials

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

capabilities today. Flexibility for tomorrow.

TECAN. infinite 200. Instructions for Use for. Document Part No.: Document Revision No.: 1.4

Absentee layer. A layer of dielectric material, transparent in the transmission region of

AvaLight-DHc Full-range Compact Light Source

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Historical. McPherson 15 Mount

Simplicity. Reliability. Performance. ProdigyPlus

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Fluorescence Lifetime Measurements of BODIPY and Alexa Dyes on ChronosFD and K2

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Assay development (biochemical protein-protein interaction assays)

The Best Way to Get the Right Answers... is in a Flash

BYK-mac i Multi-angle color, effect and fluorescence measurement. Gabriele Kigle-Böckler, BYK-Gardner GmbH, 2013

flexible lighting technology

Working Simultaneously. The Next Level of TIRF Microscopy. cell^tirf Illuminator Motorized Total Internal Reflection Fluorescence

Turn Speed Into Profitability

Oriel Cornerstone 130 1/8 m Monochromator

POLARIZATION EXTINCTION RATIO METER

Basic Instrumentation

Cary 50 UV-Vis UV-VIS. SARIN sas di Leo Temin & C. VARIAN, INC. SPECTROPHOTOMETERS

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

OMR and Image Scanner. System Solutions. Reliability You Need From The Company You Trust. The Power of Multiple Data Collection Capabilities

Transcription:

MICROPLATE READERS Synergy NEO HTS Multi-Mode Microplate Reader The smart alternative for today s assay development and screening applications.

The Smarter HTS Reader Synergy NEO is designed for today s HTS screening assays, featuring multiple parallel detectors for ultra-fast measurements and a dedicated filter-based system for live cell assays. Adaptability and flexibility, along with speed, are key requirements of today s screening laboratory. Synergy NEO was designed to meet these new requirements, without compromising on performance. Hybrid Technology Synergy NEO s filter-based optical systems are a primary component of the patented Hybrid Technology* found in several Synergy models. This exclusive technology combines high-performance, filter-based optical systems with quadruple monochromator optics, providing both excellent performance and assay versatility. For added application flexibility, a laser-based Alpha detection module is available in select NEO models; a powerful addition to the Hybrid Technology. 2012 Drug Discovery Product of the Year - Scientists Choice Award *US patent 8,218,141

Optimized Optical Design Optical design is critical to the performance of multi-mode microplate readers. NEO s filterbased optical systems are designed to create a compact, direct, unobstructed light path to minimize light loss and to maximize light delivery to both the sample and detector. This filter-based system is the perfect complement to the monochromator optical system which provides wavelength with a quadruple grating architecture for uncompromised flexibility. Any assay from the low UV to the near infrared may be automated on this reader, without ever needing a new filter. Synergy NEO s Top-Reading Filter Optical System: Fiber-free light path means less light loss and stronger excitation signal Dual PMT detectors provide simultaneous, fast ratiometric measurements Mirror/filter cubes provide high efficiency and assay flexibility Automated Z-height adjustment for optimized detection Synergy NEO s Bottom-Reading Filter-Based Optics: Optimized for high-performance on live-cell assays Fiber-free light path means less light loss and stronger excitation signal Automated Z-height adjustment to position filter close to the sample plate Separate dedicated PMT detector

Proven Performance Synergy NEO s optical design results in excellent performance and high Z -factors. NEO was benchmarked by third-party laboratories against reference instrumentation and was found to perform better than leading competitors*. A full range of screening assay technologies was tested, including: AlphaScreen / AlphaLISA HTRF / TR-FRET Fluorescence polarization Luminescence Cell-based assays Early user testing found that NEO s software, Gen5 Data Analysis Software, was much easier to use than traditional HTS reader software, with its: Uncomplicated, intuitive workflow interface Comprehensive reader control Powerful data analysis Easy export options Synergy NEO (xenon) Dual PMT competitor (xenon) Dual PMT competitor (laser) 78 pg/ml (blue) 0.32 0.03 0.44 156 pg/ml (green) 0.68 0.50 0.68 Z -factor calculation illustrates the benefits of NEO s optical design, outperforming a dual PMT competitor using a xenon flash and with performance similar to the competitor using laser-based excitation. Visit the Tech Resources section at www.biotek.com for a complete list of current application guides, notes and poster presentations highlighting NEO s assay versatility. *Independent test data available.

Speed + Automation Without Compromise With Synergy NEO, it s all about speed and outstanding performance. Plate reading, data analysis and throughput are all managed quickly and efficiently. Adding the BioStack Microplate Stacker to NEO makes it a walk-away automated platform and the fastest reader/stacker combination on the market. Dual PMT top optics for ultra-fast ratiometric measurements Read 96-well plates in 6 seconds, 384 wells in 11 seconds NEO stacker plate exchange time of 6 seconds Stacker available with 10-, 30- or 50-plate capacity 1-D and 2-D multi-position barcode scanning

Synergy NEO Specifications General Detection method Read mode Microplate types Temperature control Shaking Read height Kinetic speed With Stacker, minimum processing time per plate Barcode reader Software Absorbance range Bandpass Dynamic range Resolution Patented Hybrid Technology Quadruple Monochromators and Filter Cubes Fluorescence, Time-Resolved Fluorescence, Fluorescence Polarization, AlphaScreen /AlphaLISA, Luminescence, UV-Visible Absorbance End point, kinetic, spectral scanning, well-area scanning 1- to 1536-well plates Compatible with Take3 Micro-Volume Plates 3º C above ambient to 65º C ±0.5º C at 37º C Linear, orbital, double orbital Auto Z, 0.1 mm steps, top/bottom (filters), top (mono) 96 well: 6 seconds 384 well: 11 seconds 1536 well: 25 seconds 96 well: 20 seconds 384 well: 25 seconds 1536 well: 39 seconds Multi-directional, 2D camera-based Gen5 Data Analysis Software Xenon flash lamp Monochromator 230-999 nm, 1 nm increment 2 nm (230-285 nm), 4 nm (>285 nm) 0-4.0 OD 0.0001 OD Fluorescence Intensity range Bandpass Detection system Xenon flash lamp Quadruple monochromator: Fluorescein 2 pm typical - Top Fluorescein 2.5 pm typical - Bottom Filter cubes: Fluorescein 0.5 pm typical - Top Fluorescein 1 pm typical - Bottom Double grating monochromators (top/bottom) and, Filter cubes (top/bottom) Monochromators: 250-850 nm Filters cubes: 200-850 nm Monochromators: 16 nm excitation / emission Filters: filter-dependent, from 5 nm to >100 nm Two matched PMTs top filter system Low noise PMT bottom filter system Red shifted PMT top/bottom monochromator system Luminescence range Dynamic range 5 amol ATP typical (flash) 300-700 nm >6 decades Fluorescence Polarization range Xenon flash 1 mp at 1 nm fluorescein typical Filter cubes (top / bottom) 320-850 nm Time-Resolved Fluorescence range Alpha Read speed Reagent Dispensers Number Dispense volume Dead volume Plate geometry Xenon flash Europium 40 fm typical (384-well low volume plate) Filter cubes (top/bottom) Double grating monochromator (top / bottom) Filters: 200-850 nm Monochromators: 250-850 nm 100 mw 680 nm laser 100 amol LCK peptide Filter cubes 96 well: 30 seconds 384 well: 1 minute, 50 seconds 1536 well: 7 minutes, 20 seconds 2 syringe pumps 5-1000 µl in 1 µl increments 1.1 ml, 100 µl with back flush 6- to 384-well microplates Dispense precision <2% at 50-200 µl Dispense accuracy ±1 µl or 2% Physical Characteristics Power Dimensions Weight Regulatory 250 Watts max. 15.4 W x 20.7 D x 16.1 H (39 x 52.5 x 41 cm) 78 lbs (35 kg) For In Vitro Diagnostic use. All BioTek microplate instrumentation is CE and TUV marked. Specifications are subject to change. BioTek Instruments, Inc. Highland Park, P.O. Box 998 Winooski, Vermont 05404-0998, USA Phone: 802-655-4040 Toll-Free: 888-451-5171 Outside the USA: 802-655-4740 Fax: 802-655-7941 www.biotek.com AlphaScreen and AlphaLISA are registered trademarks of Perkin Elmer Inc. HTRF is a registered trademark of Cisbio International.