Optimum Fuel Cell Utilization with Multilevel Inverters

Similar documents
Multiple Input Converters for Fuel Cells

Hybrid Cascaded H-bridges Multilevel Motor Drive Control for Electric Vehicles

The Selective Harmonic Elimination Technique for Harmonic Reduction of Multilevel Inverter Using PSO Algorithm

Harmonic Elimination for Multilevel Converter with Programmed PWM Method

A Novel Multilevel Inverter Employing Additive and Subtractive Topology

Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing

II. WORKING PRINCIPLE The block diagram depicting the working principle of the proposed topology is as given below in Fig.2.

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Selective Harmonic Elimination Technique using Transformer Connection for PV fed Inverters

Reduced PWM Harmonic Distortion for a New Topology of Multilevel Inverters

Temperature-Dependent Characterization of SiC Power Electronic Devices

MULTILEVEL pulsewidth modulation (PWM) inverters

Analysis of IM Fed by Multi-Carrier SPWM and Low Switching Frequency Mixed CMLI

COMPARATIVE STUDY OF DIFFERENT TOPOLOGIES OF FIVE LEVEL INVERTER FOR HARMONICS REDUCTION

A 55 kw Three-Phase Automotive Traction Inverter with SiC Schottky Diodes

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Implementation of Novel Low Cost Multilevel DC-Link Inverter with Harmonic Profile Improvement

COMPARATIVE ANALYSIS OF SELECTIVE HARMONIC ELIMINATION OF MULTILEVEL INVERTER USING GENETIC ALGORITHM

CARRIER BASED PWM TECHNIQUE FOR HARMONIC REDUCTION IN CASCADED MULTILEVEL INVERTERS

Analysis of Cascaded Multilevel Inverters with Series Connection of H- Bridge in PV Grid

Performance Metric of Z Source CHB Multilevel Inverter FED IM for Selective Harmonic Elimination and THD Reduction

15-LEVEL CASCADE MULTILEVEL INVERTER USING A SINGLE DC SOURCE ABSTRACT

Real-Time Selective Harmonic Minimization in Cascaded Multilevel Inverters with Varying DC Sources

Keywords: Multilevel inverter, Cascaded H- Bridge multilevel inverter, Multicarrier pulse width modulation, Total harmonic distortion.

Multilevel Inverters for Large Automotive Electric Drives

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Optimal PWM Method based on Harmonics Injection and Equal Area Criteria

Charge Balance Control Schemes for Cascade Multilevel Converter in Hybrid Electric Vehicles

Keywords Cascaded Multilevel Inverter, Insulated Gate Bipolar Transistor, Pulse Width Modulation, Total Harmonic Distortion.

Simulation and Analysis of a Multilevel Converter Topology for Solar PV Based Grid Connected Inverter

Design of DC AC Cascaded H-Bridge Multilevel Inverter for Hybrid Electric Vehicles Using SIMULINK/MATLAB

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

Performance of Sinusoidal Pulse Width Modulation based Three Phase Inverter

MULTICARRIER TRAPEZOIDAL PWM STRATEGIES FOR A SINGLE PHASE FIVE LEVEL CASCADED INVERTER

Universal Multilevel DC-DC Converter with Variable Conversion Ratio, High Compactness Factor and Limited Isolation Feature

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

Comparison Of DC-DC Boost Converters Using SIMULINK

Performance Evaluation of a Cascaded Multilevel Inverter with a Single DC Source using ISCPWM

International Journal of Advance Engineering and Research Development

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Harmonic Reduction in Induction Motor: Multilevel Inverter

Speed Control of Induction Motor using Multilevel Inverter

A New Single-Phase Multilevel Inverter with Reduced Number of Switches for Solar Applications

Harmonic elimination control of a five-level DC- AC cascaded H-bridge hybrid inverter

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

COMPARATIVE STUDY ON CARRIER OVERLAPPING PWM STRATEGIES FOR THREE PHASE FIVE LEVEL DIODE CLAMPED AND CASCADED INVERTERS

Performance and Analysis of Hybrid Multilevel Inverter fed Induction Motor Drive

A STUDY OF CARRIER BASED PULSE WIDTH MODULATION (CBPWM) BASED THREE PHASE INVERTER

Simulation and Experimental Results of 7-Level Inverter System

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

29 Level H- Bridge VSC for HVDC Application

Comparison of 3-Phase Cascaded & Multi Level DC Link Inverter with PWM Control Methods

Analysis of Harmonic Reduction for Synchronized Phase-shifted Parallel PWM Inverters with Current Sharing Reactors

Levels of Inverter by Using Solar Array Generation System

A comparative study of Total Harmonic Distortion in Multi level inverter topologies

Seven-level cascaded ANPC-based multilevel converter

MODELING AND ANALYSIS OF THREE PHASE MULTIPLE OUTPUT INVERTER

A Comparative Analysis of Multi Carrier SPWM Control Strategies using Fifteen Level Cascaded H bridge Multilevel Inverter

A Power Electronic Transformer (PET) fed Nine-level H-Bridge Inverter for Large Induction Motor Drives

A New Multilevel Inverter Topology with Reduced Number of Power Switches

A Comparative Study of SPWM on A 5-Level H-NPC Inverter

Simulation of Single Phase Multilevel Inverters with Simple Control Strategy Using MATLAB

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

A New Transistor Clamped 5-Level H-Bridge Multilevel Inverter with voltage Boosting Capacity

A HYBRID CASCADED SEVEN - LEVEL INVERTER WITH MULTICARRIER MODULATION TECHNIQUE FOR FUEL CELL APPLICATIONS

AN IMPROVED MODULATION STRATEGY FOR A HYBRID MULTILEVEL INVERTER

Hybrid Modulation Switching Strategy for Grid Connected Photovoltaic Systems

PERFORMANCE ANALYSIS OF SEVEN LEVEL INVERTER WITH SOFT SWITCHING CONVERTER FOR PHOTOVOLTAIC SYSTEM

Fifteen Level Hybrid Cascaded Inverter

Three Phase 11-Level Single Switch Cascaded Multilevel Inverter

Performance Evaluation for Different Levels Multilevel Inverters Application for Renewable Energy Resources

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

A Comparative Modelling Study of PWM Control Techniques for Multilevel Cascaded Inverter

ADVANCES in NATURAL and APPLIED SCIENCES

Regular paper. Evolutionary Computing Based Area Integration PWM Technique for Multilevel Inverters

Reduction Of Harmonics & Torque Ripples Of Bldc Motor By Cascaded H-Bridge Multi Level Inveter Using Current & Speed Control Techniques

Switching Angles and DC Link Voltages Optimization for. Multilevel Cascade Inverters

AKEY ISSUE in designing an effective multilevel inverter

CONCLUSIONS AND SCOPE FOR FUTURE WORK

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter: Application to Voltage-Boost in a PM Drive

SPECIFIC HARMONIC ELIMINATION SCHEME FOR NINELEVEL CASCADED H- BRIDGE INVERTER FED THREE PHASE INDUCTION MOTOR DRIVE

Hybrid 5-level inverter fed induction motor drive

Modular Capacitor Clamped DC-DC Converter Featuring Fault Tolerant Capability

Power Quality Enhancement of Diode Clamped Multilevel Inverter Using Different Modulation Schemes

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

EVALUATION OF VARIOUS UNIPOLAR MULTICARRIER PWM STRATEGIES FOR FIVE LEVEL FLYING CAPACITOR INVERTER

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

THD Minimization in Cascade Multi-level Inverters with a Few DC Sources and Optimum Voltage Levels

Keywords Asymmetric MLI, Fixed frequency phase shift PWM (FFPSPWM), variable frequency phase shift PWM (VFPSPWM), Total Harmonic Distortion (THD).

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

Control of Power Converters for Distributed Generation

A Cascaded H-Bridge Multilevel Inverter with SOC Battery Balancing

Minimization of Switching Devices and Driver Circuits in Multilevel Inverter

Optimum Harmonic Reduction With a Wide Range of Modulation Indexes for Multilevel Converters

Generating Isolated Outputs in a Multilevel Modular Capacitor Clamped DC-DC Converter (MMCCC) for Hybrid Electric and Fuel Cell Vehicles

Analysis of switched inductor Z-source modified cascaded H-Bridge multilevel inverter

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

Transcription:

th Annual IEEE Power Electronics Specialists Conference Aachen, Germany, Optimum Utilization with Multilevel Inverters Burak Ozpineci Oak Ridge National Laboratory Knoxville, TN USA Email: burak@ieee.org Leon M. Tolbert,, Zhong Du The University of Tennessee Knoxville, TN USA Email: tolbert@utk.edu, zdu@utk.edu Abstract Static characteristics of fuel cells show more than a % difference in the output voltage between no-load to fullload conditions. This inevitable decrease, which is caused by internal losses, reduces the utilization factor of the fuel cells at low loads. Additionally, the converters fed by these fuel cells have to be derated to accommodate higher input voltages at low currents. To increase the utilization of fuel cells and to avoid derating of semiconductors, this paper proposes a level reduction control using a multilevel inverter. Level reduction is done by inhibiting a certain number of fuel cells when the load current decreases. The inhibited fuel cells can be used in other applications such as charging batteries to further increase their utilization and the efficiency of the system. I. INTRODUCTION Human dependence on electricity is growing faster with time. Coal, oil, and other energy sources have been used to generate electricity for more than a century. Today, conventional fossil energy supplies, such as oil, coal and natural gas, are rapidly depleting, and NO x, CO and SO air pollution due to fossil fuels is a major environmental concern. To overcome these problems, renewable energy sources must replace fossil energy sources [,]. Fuel cell technology is one of the options for renewable energy sources. The electrical efficiency of a fuel cell can be greater than 7% in theory (the present technology is capable of reaching around % efficiency). The cogeneration of electrical energy and heat improves the exploitation of the primary energy source. The product of the chemical reaction in fuel cells is H O when H is used as fuel, and no pollutants like SO x or NO x, are produced; therefore, the fuel cells are environmentally cleaner than traditional generators. U.S. Department of Energy s Solid-State Energy Conversion Alliance (SECA) program [] is targeting solid oxide fuel cell (SOFC) modules in the kw range to be made available for residential applications [-6]. In addition to residential use, these modules are expected to be used in high power applications such as apartment buildings, Prepared by the Oak Ridge National Laboratory, Oak Ridge, Tennessee 78, managed by UT-Battelle for the U.S. Department of Energy under contract DE-AC-OR7. The submitted manuscript has been authored by a contractor of the U.S. Government under Contract No. DE-AC-OR7. Accordingly, the U.S. Government retains a non-exclusive, royalty-free license to publish from the contribution, or allow others to do so, for U.S. Government purposes. hospitals, schools, etc. For example, a hospital might require a kw power supply. To provide this power using the SOFC modules, of the kw modules would be required. These modules can be integrated in different configurations to yield the necessary power. The multilevel converter family is one of the options for this integration because they require multiple dc inputs. Multilevel converters are of interest especially in the distributed energy resources area because several batteries, fuel cells, solar cells, wind turbines, and microturbines can be connected through a multilevel converter to feed a load or the ac grid without voltage balancing problems. Another major advantage of multilevel converters is that their switching frequency can be lower than a traditional converter, which means reduced switching losses and increased efficiency. In this paper, a multilevel inverter is used to overcome some problems associated with the fuel cell V-I characteristics. The static (V-I) characteristics of fuel cells show more than a % difference in the output voltage between no-load to full-load conditions (Fig. ). This inevitable decrease, which is caused by internal losses, reduces the utilization factor of the fuel cells at low loads. Additionally, the converters fed by these fuel cells have to be derated to accommodate higher input voltages at low currents. To increase the utilization of fuel cells and to avoid derating of semiconductors, this paper proposes a level reduction control technique for a multilevel inverter. Cell voltage, V.. Theoretical EMF or Ideal voltage Region of activation polarization (Reaction rate loss) Region of ohmic polarization (Resistance loss) Total loss Current density, ma/cm Region of concentration polarization (Gas transport loss) Fig.. Theoretical V-I polarization curve of the fuel cell used in the calculations. -78-899-//$. IEEE. 798

th Annual IEEE Power Electronics Specialists Conference Aachen, Germany, II. GENERAL FUEL CELL V-I POLARIZATION CURVE The general V-I polarization curve for a single-cell fuel cell is shown in Figs. and where the reduction of the fuel cell voltage with load current density can be observed. This voltage reduction is caused by three major losses [7-9]. At low current densities, the dominant loss is the activation loss, which is caused by the slowness of the reactions taking place at the electrode surface. The voltage drop created by the activation loss is highly non-linear. Ohmic losses are caused by the flow of electrons through the electrolyte and through the electrodes. The electrolyte should only transport ions through the cell; however, a small amount of fuel diffusion and electron flow occurs. Ohmic losses are essentially linear, i.e. proportional to the current density. Decreasing the electrode separation and enhancing the ionic conductivity can reduce the ohmic losses. The final loss component is the gas transport loss at higher current densities. As the reactant is consumed at the electrode, the concentration of the surrounding material reduces because not enough reactants and products are being transported to and from the electrodes. The output voltage decreases with the decrease in the concentration. III. CASCADED MULTILEVEL CONVERTERS The cascaded multilevel converter is one of several multilevel configurations. It is formed by connecting more than one single-phase H-bridge converter in series as shown in Fig.. Each converter generates a square wave voltage waveform with different duty ratios, which together form the output voltage waveform as in Fig.. A three-phase configuration can be obtained by connecting three of these converters in Fig. in wye or delta. Instead of square waves, it is also possible to get PWM output voltages; however, in this paper, fundamental frequency switching will be emphasized instead of high frequency PWM switching. IV. LEVEL REDUCTION TECHNIQUE Today, there is not yet a standard rating for the output V V D FC D FC D FC C dc C dc C dc Q D Q D Q D Q D Q D Q D Q D Q D Q n D n Q n D n Q n D n Q n D n Fig.. 7-level cascaded multilevel inverter. voltage of a fuel cell. Present fuel cells are typically producing dc voltages between V and V at full-load. When one of these fuel cells is connected to an inverter, they will not be able to produce ac grid level voltages. A dcdc boost converter is generally required to boost the voltage level for the inverter. This boost converter, in addition to boosting the fuel cell voltage, also regulates the inverter input voltage and isolates the low and high voltage circuits. The inverter for a residential application is either single- or dual-phase. Residential applications and others, including hospitals, schools, apartment buildings etc. have a daily load profile with hours of full-load operation and hours of low-load operation. The application will be designed for full-load conditions; however, during low load operation, because of the load dependent characteristics of the fuel cells, the fuel cell voltage can be up to % more than the full-load case. This increase in the voltage requires derating of the inverter devices. The dc-dc boost converter keeps the dc-link constant so a V ao o +V 7 Fuel cell stack voltage, V 6 θ θ θ V π/ π π - -( ) -( +V ) V Fuel cell stack current, A Fig.. Polarization curve for a kw solid oxide fuel cell module []. Fig.. n-level cascaded multilevel inverter waveform generation. 799

th Annual IEEE Power Electronics Specialists Conference Aachen, Germany, that the inverter switches are not necessarily derated; however, the dc-dc converter switches still have to be derated. It also increases the cost without much of a benefit considering that isolation or voltage boost might not be essential in this application. A better solution is the level reduction technique described in [] using a multilevel dc-dc converter supplying power to a three-phase inverter. Level reduction is done by inhibiting fuel cells one by one when the load current decreases. Then, the voltage across the inverter switches is reduced, still maintaining the voltage and power required by the inverter and the load. Note that the level reduction technique is proposed for applications such as apartment buildings, schools, hospitals, etc. where the load varies throughout the day. However, the load variation is generally not fast; therefore, high frequency switching of the multilevel dc-dc converter is not a problem. Since this converter merely changes the dc voltage level when required, the control of the converter is rather simple. V. CASCADED MULTILEVEL INVERTERS As an alternative to the dc-dc converter configuration, this paper focuses on a cascaded multilevel inverter. The advantage of this configuration compared to the earlier one is that all the switches of the multilevel inverter configuration will have low voltage ratings unlike the higher voltage ratings of the inverter switches in []. However, a disadvantage is that there will be two switches conducting the load current for each fuel cell compared to one in []. These two switches reduce the efficiency of the system because of the additional conduction losses; therefore, it is not wise to use a multilevel inverter system for low voltage fuel cells but should rather be considered for higher voltage fuel-cells. VI. LEVEL REDUCTION CONTROL For a multilevel inverter to operate at fundamental switching frequency, the switching angles should be carefully selected so that the total harmonic distortion (THD) is reduced. Solutions for angles for inverters with different number of levels have been presented in the literature []. These angles are stored in look-up tables with respect to the modulation indices. For a reduced level multilevel inverter, several sets of these angles have to be stored, and an algorithm has to be developed to determine when to reduce the levels, which increases the control complexity. In this paper, a multilevel fundamental frequency sinetriangle wave comparison technique inspired from multilevel PWM [-9] is introduced to simplify the control system. Fig. shows the modulating waveform and the carrier waveforms for a 7-level (-fuel cell) system. Because there are three converters available, three carrier waves are required, one for each converter. These carrier waves are (V c /) peak-to-peak and (V c /) offset from each other where V c is equivalent to the peak of the carrier wave V c V c / V c / Vdc Vdc Vdc Modulating wave Output voltage waveform Carrier waves Fig.. Fundamental switching sine triangle wave comparison. in sinusoidal PWM for a single converter. For an n- converter system, the carrier waves would be (V c /n) peakto-peak and (V c /n) offset from each other. As can be observed from Fig., if the amplitude of the modulating wave is greater than ( V c /), no H-bridges are inhibited. If it is between ( V c /) V and (V c /), then one inverter is inhibited, and if it is less than (V c /), two inverters are inhibited. The modulation index for a multilevel inverter is defined as m a /(n V dc /π), where n is the number of levels and V dc is the voltage input to each H-bridge. Fig. 6 shows the input-output relationship of a -level inverter for the fundamental frequency sine-triangle comparison system. For each m a in the x-axis, the y-axis shows the scaling factor that gives the peak output voltage when multiplied by V dc. This relationship is not linear for any m a as would have been expected when compared with other similar modulation techniques. The modulation index of a n-level inverter depends on two variables, the dc input (fuel cell output) voltage and the output fundamental voltage. For a constant fundamental output voltage, if the dc input voltage increases, then m a needs to decrease. The voltage in a fuel cell system will increase in low load conditions; therefore, the modulation index will decrease. Fig. 6 shows that as the modulation index decreases, the levels will be reduced automatically. The level reduction is simulated for a 6 fuel cell multilevel inverter and the transition from high-to-low load or from levels to -levels is illustrated in Fig. 7. Output voltage scaling factor 7 6 7 9 6 dc sources levels none inhibited...6.8. Modulation index Fig. 6. Modulation index correction plot. 8

th Annual IEEE Power Electronics Specialists Conference Aachen, Germany, Output Voltage, V - - - HIGH LOAD -Levels -.8.9.9...... Time, s LOW LOAD -Levels Fig. 7. Output voltage waveform simulated for high-load to low-load transition. The inhibited H-bridges and fuel cells can be used to charge batteries to increase the efficiency and the utilization of the fuel cells further. Moreover, since the lifetime of a fuel cell is generally given in operating hours, by alternating the inhibited fuel cell(s), the operating lifetime of the fuel cell can also be extended. Since a simple sine-triangle comparison is being used instead of switching angle optimization techniques, total harmonic distortion (THD) might be a concern. Fig. 8 shows the THD of values of the output voltage waveform when level reduction control with sine-triangle comparison is used. Note that for the calculation, harmonics up to and including the st order harmonic are used and the triplen harmonics are ignored. The plot shows that as expected THD decreases at higher modulation indices, i.e. when more levels are present. It must be noted that this is the THD for the unfiltered voltage waveform. If a further reduction in THD is required, then the frequency of the carrier wave can be increased for low frequency PWM operation. VII. EXPERIMENTAL RESULTS The control algorithm has been tested on a kw cascaded multilevel inverter. Since no fuel cells were available in the lab, possible fuel characteristics were simulated and the multilevel inverter was operated in two conditions: low load and full load. At low loads, the fuel cell voltage increases and consequently the modulation index decreases. In this case, for a modulation index of., seven levels are enough to produce the required fundamental output voltage as shown in Figs. 9 and. For higher loads, the fuel cell voltage decreases and the modulation index increases. For a modulation index of.8, the number of required levels go up to eleven as shown in Figs. and. THD values of up to st harmonic in both cases are given as 7.% for m a =. and 7.% for m a =.8. As expected for lower modulation index, the THD is worse. To improve the THD of the output voltage waveforms, a filter could be employed. Another alternative is to increase the frequency of the carrier wave so that the output waveform will be more like a low frequency multilevel PWM voltage. VIII. CONCLUSIONS A novel reduced level control technique for multilevel inverters exploiting the V-I characteristics of fuel cells is introduced. With this control, the need for derating power semiconductors in fuel cell systems is eliminated. By inhibiting some of the H-bridges, the fuel cell utilization is increased. The fuel cells in the inhibited H-bridges can be used to charge batteries, increasing the system efficiency. For the multilevel inverter, a fundamental switching sinetriangle comparison method is introduced. This method decreases the complexity of the level reduction control for the multilevel inverters by eliminating the need for storing separate switching angle look-up tables for multilevel inverters for each number of dc sources. REFERENCES [] C.A. Forbes, J.F. Pierre, The solid fuel cell future, IEEE Spectrum, (), Oct. 99, pp.. [] D.J. Hall, R.G. Colclaser, Transient modeling and simulation of a tubular solid oxide fuel cell, IEEE Transactions on Energy Conversion, (), Sept. 999, pp. 79 7. [] Solid State Energy Conversion Alliance webpage, 8 m=., fundamental frequency=6 Hz Total harmonic distortion (THD), % 8 6 8 6 dc sources inhibited -levels dc sources inhibited 7 levels dc sources inhibited 9 levels dc sources inhibited 7-levels dc sources inhibited levels....6.7.8.9.. Modulation index Fig. 8. Total harmonic distortion with respect to the modulation index. Voltage (V) 6 - - -6-8.......... Time (s) Fig. 9. 7-level output voltage waveform for low fuel cell load. 8

th Annual IEEE Power Electronics Specialists Conference Aachen, Germany, 6 m=., fundamental frequency=6 Hz 6 m=.8, fundamental frequency=6 Hz Magnitude (V) Magnitude (V) Frequency (Hz) Frequency (Hz) Fig.. FFT of the voltage waveform in Fig. 9. http://www.seca.doe.gov/ [] C. D. M. Oates, R. W Crookes, S. H Pyke, and R. T. Leah, Power conditioning for solid oxide fuel cells, International Conference on Power Electronics, Machines, and Drives, June, pp. 7. [] K. W. E. Cheng, D. Sutanto, Y. L. Ho, K. K. Law, Exploring the power conditioning system for fuel cell, IEEE nd Annual Power Electronics Specialists Conference, June, pp. 97. [6] K. Sedghisigarchi, A. Feliachi, Control of grid-connected fuel cell power plant for transient stability enhancement, IEEE Power Engineering Society Winter Meeting, Jan., pp. 8 88. [7] DOE Handbook, 6th edition,, pp. - m a -. [8] J. Larminie, A. Dicks, Systems Explained, pp. 9. [9] G. Hoogers, Technology Handbook, CRC Press,, pp. - -9. [] L. A. Chick, J. W. Stevenson, R. E. Williford, S. P. Simner, PNNL SOFC Excel Spreadsheet model, PNNL-SA-69, August. [] B. Ozpineci, L. M. Tolbert, G. J. Su, Z. Du, Optimum fuel cell utilization with multilevel DC-DC converters, IEEE Applied Power Electronics Conference, February, pp. 7 76. [] J. N. Chiasson, L. M. Tolbert, K. J. McKenzie, Z. Du, Control of a Multilevel Converter Using Resultant Theory, IEEE Transactions on Control System Theory, (), May, pp. -. Fig.. FFT of the voltage waveform in Fig.. [] L. M. Tolbert, F. Z. Peng, T. G. Habetler, Multilevel PWM Methods at Low Modulation Indices, IEEE Transactions on Power Electronics, (), July, pp. 79-7. [] L. M. Tolbert, F. Z. Peng, Multilevel Converters as a Utility Interface for Renewable Energy Systems, IEEE Power Engineering Society Summer Meeting, July, Seattle, Washington, pp. 7-7. [] J. S. Lai, F. Z. Peng, Multilevel Converters - A New Breed of Power Converters, IEEE Transactions Industry Applications, (), May/June 996, pp. 9-7. [6] F.Z. Peng, F. Zhang, Z. Qian, A Magnetic-less DC-DC Converter for Dual Voltage Automotive Systems, 7th IAS Annual Meeting Industry Applications Conference, October, pp. -. [7] F. Z. Peng, A Generalized Multilevel Inverter Topology with Self Voltage Balancing, IEEE Transactions on Industry Applications, 7(), March-April, pp. 6 68. [8] G. Sinha, T.A. Lipo, A New Modulation Strategy for Improved DC Bus Utilization in Hard And Soft Switched Multilevel Inverters, rd International Conference on Industrial Electronics, Control and Instrumentation, November 997, pp. 67-67. [9] G. Carrara, S. Gardella, M. Marchesoni, R. Salutari, G. Sciutto, A New Multilevel PWM Method: A Theoretical Analysis, IEEE Transactions on Power Electronics, 7(), July 99, pp. 97-. 8 m=.8, fundamental frequency=6 Hz 6 Voltage (V) - - -6-8.......... Time (s) Fig.. -level output voltage waveform for high fuel cell load. 8