Step 1: ttach Mount to Work Surface Two-Piece Table lamp and eep Table lamp llen wrenches (in inches): lamp lower to upper jaw 5/32 () lamp compression screws 1/4 () or installation on a work surface positioned against a wall or panel: 1. Remove clamp lower jaw (), by removing both clamping screws () and both lower jaw mounting screws (). 2. Slide upper jaw (E) down along edge of desk surface. 3. eneath work surface, replace lower jaw (), by reinstalling (2) mounting screws (), 4. Reinstall (2) clamping screws () and (2) pressure discs (). Tighten both clamping screws () with pressure discs () in place on top of clamping screws (). o not over-tighten as this may damage the table surface. or installation on open edge of work surface: 1. Slide table clamp () onto edge of desk surface. With pressure discs () in place on top of clamping screws (), tighten both clamping screws (). o not over-tighten as this may damage the table surface. Note: The eep Table lamp (ig. 1) is one piece and can only be mounted on open edge of worksurface as described above. E ig. 1 eep Table lamp work surface 2
Grommet Mount ixed Table Mount 3/4 open end wrench () 3/4 open end wrench () rill (17/32 ) 1. hoose the orientation of grommet mount plate () on the work surface. Remove grommet cover and any moveable grommet liner. 2. Place the grommet mount plate () over the grommet hole, with ½ hole for the threaded connection stud () inside the grommet hole. djust placement of the grommet mount plate () so it equally overhangs the grommet hole. 3. eneath the desk, slide the mounting bar () and washer () onto the threaded connection stud (). Thread nut () onto threaded connection stud (). 4. Thread connection stud () thru grommet hole, thru ½ hole in plate () then into stem (E). Tighten nut () using a wrench. o not over-tighten as this may damage the table surface. 1. Establish desired mounting location. rill a 17/32 diameter hole through the table surface/desk top. ssemble flat washer () and lock washer () and nut () onto stud (). 2. rom beneath the desk, push top of stud () up through hole. Slide second disc () over stud (). Thread stem (E) onto stud () using all available threads in stem. 3. Tighten nut (). o not over-tighten as this may damage the table surface. E E work surface work surface 3
Step 1: ttach Mount to ntenna Table enter eam ntenna Table enter eam Side Mount Phillips Screwdriver () 1. Insert (2) slot nuts () into side channel of beam of ntenna ig Table by pushing one side (long edge) down into the channel until the following edge/side drops into the channel. 4. Slide slot nuts () to desired mounting location. ssemble ntenna Table enter eam Side Mount () by dropping bracket on side flange of beam () and securing with screws () into slot nuts (). Tighten securely. 4
Step 1: ttach Mount to Interpole Interpole hannel Mount Interpole Slot Mount llen wrenches (in inches) rill 7/32 Phillips Screwdriver () & () nti-dislodgement 5/64 (G) 1. If applicable, remove and retain any channel cover from Interpole. Establish desired height on Interpole then drill (3) 7/32 pilot holes for screws (). Note: ottom of monitor support arm post will be almost 3/16 above the center mounting screw. 2. Install bracket () using (3) screws (). 3. ttach mount plate () with top hook () oriented upwards to bracket () using 4 screws (). llen wrenches (in metric) Screw () M4 1. Insert (2) slot nuts () into center channel of Interpole by pushing one side (long edge) down into the channel until the opposite side drops into the channel. 2. Slide slot nuts () to desired mounting location. Secure mount plate () with top hook () oriented upwards with screws () and tighten securely. 4. Hang mounting bracket () onto mount plate () by engaging hanger bar (E) with top hook (). Seat mounting bracket () down fully and secure with screw (G). 3. Hang mounting bracket () on mount plate () by engaging hanger bar (E) with top hook (). Seat mounting bracket () down fully and secure with screw (G). ack view ack view E E G G 5
Step 2: ttach Monitor rm to Mounts None 1. Install Sapper XYZ monitor arm by inserting the stem () into the hole () in the bottom of the post. Seat firmly. 6
Step 3: Remove The ttached Movement Joints from The rossbar ttaching the Monitor to the rm None 1. Remove the fast release pin () from the crossbar sliders (), by pushing up from the bottom of the fast release pin (), disconnecting both movement joints (). 7
Step 4: ttach Monitor to The Movement Joints ttaching the Monitor to the rm ttaching the Monitor to the rm Screwdriver or llen wrench 1. Remove monitor base and hardware from the monitor. Retain all hardware. 2. Place movement joint () against back of monitor with Knoll logo toward top of monitor and attach the VES plate () using appropriate hardware. VES plate can accommodate 75 mm or 100 mm hole patterns. Note: Movement joint can hold up to 18.5 lbs. Note: heck VES compliancy and hole pattern on monitor or television as Knoll monitor solutions are designed to work with VES compliant monitors only. The Knoll VES plate can accommodate 75mm or 100mm hole patterns. Knoll movement joints do not ship with screws and are designed to accept an M4 or M5 screw; length is dependent on the specific monitor or television and screw should be tested prior to installation to ensure correct length; Knoll is not responsible for use of incorrect screws. If monitor has recessed VES mounting surface, spacers () may be required between movement joint () and monitor. Spacers must be requested through Knoll ustomer Service. VES plate adaptor may be necessary for larger monitors and televisions and can be ordered separately in the sizes of 100 mm x 200mm (M5 screws), 200mm x 200mm (M6 screws), 300mm x 300mm (M8 screws) and 400mm x 400mm/400mm x 600mm (M8 screws). daptors ship with separate installation instructions and may require spacers. Knoll VES plate adaptors ship with screws to attach the adaptor to the Knoll VES plate but do not ship with screws to attach the adaptor to the monitor or television (see screw sizes listed above, English size equivalents may be needed instead); screw length is dependent on the specific monitor or television and screw should be tested prior to installation to ensure correct length, Knoll is not responsible for use of incorrect screws. ustomer supplied 8 ustomer supplied
Step 5: onnect The rossbar to Monitor rm ttaching the Monitor to the rm ttaching the Monitor to the rm 3/16 llen wrench (E) (included on Monitor ) 1. ttach crossbar () to monitor arm (). 2. Insert link pin () aligning flats of double- shape. 3. Insert and tighten retaining screw () using 3/16 llen wench (E). E 5ad9046_ii_d_10.eps 9
Step 6: ttach Monitors with Movement Joints to The rossbar ttaching the Monitor to the rm ttaching the Monitor to the rm None 1. Engage movement joint () on monitor one at a time to the crossbar slide (), and insert fast release pin (). When fully seated, pin should be flush at the top. 10
eatures: able Management and ast Release able Management ast Release 1. Secure cables on to the crossbar () using fastener strips (). 2. Secure cables down the post () by snapping cable management clip () over them. 1. ast release functionality allows rapid removal of monitor and movement joint. Lift monitor arm to its highest position while holding the monitor and remove the fast release pin () from the crossbar slide (), disconnecting the movement joint (). 2. To reinstall, position movement joint on monitor to crossbar slide and insert fast release pin (). When fully seated, pin should be flush at the top. astener strip able management clip 11
eatures: Weight and riction djustments Tilt and Rotation riction djustments Weight djustment 3/16 llen wrenches (in inches) () Tilt friction 3/16 (Included on Monitor ) Rotation friction 3/16 () (Included on Monitor ) 3/16 llen wrenches (in inches) () Weight adjustment 3/16 () (Included on Monitor ) Tilt friction: To increase friction, insert llen wrench (included on each monitor plate) () into screw () and turn clockwise. To reduce tilt friction, turn screw () counterclockwise. djust in very small increments. Rotation friction: To increase friction, insert llen wrench () (included on each monitor plate) () and turn clockwise. To reduce friction, turn screw () counterclockwise. djust in very small increments. 1. etermine weight of monitor. 2. Weight tension is pre-set at 10 pounds. If monitor weighs more than that, lift the monitor up to adjust weight. If monitor weighs less, push the monitor down to adjust weight. 3. Insert llen wrench () into weight adjustment nut (). Turn clockwise to decrease weight or counterclockwise to increase weight to appropriate level. The red dial should point to the weight of your monitor. Kilograms are on one side and pounds are on the other. 4. ppropriate weight has been set when monitor stays exactly where you place it and can be moved with little resistance Note: The gas strut s weight tolerance performance may be affected by temperatures above or below typical office temperatures. Tilt friction Scale Rotation friction 12 Tilt riction djustment Weight adjustment nut llen wrench