FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

Similar documents
FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

MCR-304. Installation Instructions. Wireless Interface for Hard-Wire Control Panels 1. INTRODUCTION 2. SPECIFICATIONS. 1.

INSTALLATION INSTRUCTIONS

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

WSA 8 BOX RELE Installation Manual

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

Keychain Radio Remote Control System

User s Guide Instructions for Installation and Operation

INSTALLATION INSTRUCTIONS

User s Guide Instructions for Installation and Operation

User Manual. ProRF Encoder Transmitter & Receiver

SSR VL-12P-xC-NCS

INSTALLATION AND SETUP GUIDE

SSR-150xxx-40VL-12P-xC-xxxCS

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Preliminary Data Sheet!

Radio Remote Controls Manual K Series

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

Inovonics Wireless Product Catalogue

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Astra-R Kit Wireless Alarm System Operation Manual

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Series 3000 Model R-107A

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

User Manual January Opticom Infrared System RC790 Remote Coding Unit

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

User s Guide FM Transmitter

automatic embosser & die cutter USER MANUAL

Single Flex and Double Flex Couplings (i)

Glass Electrode Meter

MaxLite LED Self-Driven LiteBars

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

2015 RIGOL TECHNOLOGIES, INC.

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

Firmware Version d & higher Installation & Operation

Transmitter. User Manual. Firmware version 1.0 and greater

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

Radio System Strobe Wizard Plus Freemask

Using the USB Output Port to Charge a Device

CRD 410 MANUAL FITTING INSERTER

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Firmware Version d & higher Installation & Operation

Field Hub Installation Guide. P/N Rev. C 05/15

ISW-EN7016 Installation Guide

WireMaster Coax BNC PN: Rev C 2/13

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Dakota Alert. WMT-3000 Wireless Transmitter. Owner s Manual

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

SCS-WB INSPIRE ASSEMBLY AND OPERATION MANUAL

EN4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

M2/M2A AC-DC Power Supply Operator s Manual

LT3000 ULTRASONIC LEVEL TRANSMITTER

P.O. BOX 1521 POLSON, MT SSR V-12C

Congratulations on your purchase of Tiger s electronic JUMBLE!

Pocket Weatheradio with Tone and Vibrating Alert

T-L 810-T TRANSMITTER GUIDE

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

Planishing hammer stand For use with SKU Planishing hammer

IRRIGATION 810-R RECEIVER GUIDE

Radio Remote Controls Manual K Series

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

ArchiTech by Networx

NCS-C150 INSTRUCTION MANUAL Rev D. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

MaxLite Linear Strip ECO Series

Model 9302 Amplifier-Discriminator Operating and Service Manual

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Instruction Sheet SNE SERIES. Cable Chase

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Fiber Optic Expansion Interface

TR1000 IRRIGATION MANUAL

Installation Guide. Delphi XM FM Direct Accessory. For Use With Roady2 and SKYFi2 Satellite Radio Receivers

SureCall TM CM800 65dB

Installation and Operating Manual. (version 4.05) AAS Access Control Station. Your Partner in Access Control

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

MODEL 8080PR3 Released on 11th Mar 2013

installation guide XMFM1

GTX 320A. Mode A/C Transponder. pilot s guide

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Digi-Stop. Installation & Operation

Signal Isolation Module. Instruction Manual SIM

NCS-C151 INSTRUCTION MANUAL Rev B. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

Wenger Corporation 2010 Printed in China 02/10 Part #148H Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

EN4232MR 32 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

EE4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

Transcription:

FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver Installation Instructions 02327C Document revision history Rev. Level Description Date B Create F:\Eng\parts\02327\02327B.doc from P:\Master.dox\FA_dox\FA404_v2.doc 7/19/01 C Replace ISO logo 8/08/01 Important Notes!"The FA404 is designed to be installed and maintained by professional security technicians.!"unless specifically noted, Inovonics products are intended for indoor use. This receiver is intended for use with indoor security systems. Use in outdoor applications may impair performance.!"test system regularly. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 1 02327C.DOC 8-Oct-01

Overview: FA404 and FA404R slave receivers fully supervise up to four wireless transmitters. The FA404 has open collector Alarm and Fault outputs. The FA404R has Form-C Alarm and Fault relay outputs. FA404R receiver ALARM FAULT NC NO NO NC 1 Output configuration selector Activated LED / Program point 1 Tampered LED / Program point 2 Low battery LED / Program point 3 Inactive point LED / Program point 4 1 2 3 4 TX PGM RESET/DEL Reset / Delete button Tx PGM Transmitter programming button Transmitter external contact selector NO NC VALID DECODE DECODE Transmitter programming header Valid decode LED Decode LED FA404 receiver ALARM FAULT NC NO NO NC A 1 T 2 B 3 I 4 Fault output Alarm output 1 2 3 4 TX PGM RESET/DEL Tx PGM NO NC VALID DECODE DECODE 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 2 02327C.DOC 8-Oct-01

Technical Specifications: Dimensions (housing): 6.38" x 3.60" x 1.10" Weight: Environmental: Operating temperature: Relative Humidity: 6.9 oz. 32-120 F (0-50 C) 95% (non-condensing) Electrical: Receiver: Power Requirement: Power Consumption: Typical: FA404R output relay Type: Operating frequency: 11-14 VDC 130mA (max, relays activated) 40mA (quiescent) Form C, 1A @ 28VDC, 0.5A @ 30VAC (resistive) frequency-hopping spread spectrum 902-928 MHz The VALID DECODE LED indicates transmissions from transmitters programmed to the receiver. The receiver programs transmitters with the following fixed parameters: No EOL resistor. No Internal Contact. (The FA404 and FA404R will not support the FA200W or FA210W widegap internal magnet contact.) 60-second supervisory check-in. (The transmitter sends a supervisory signal every 60 seconds. Some transmitters check in at 150-second intervals.) The receiver, with a fixed 4-hour supervisory window, will declare a programmed point inactive if no transmission is received during every 4 hour window. The Fault Output is Latching for low battery or tamper faults. It is Follower for Inactive faults. The Alarm Output is user-selectable to be follower, momentary, latching or toggle. Note: FA transmitters have non-volatile memory. It is not necessary to reprogram transmitters after losing power or changing batteries. Press the transmitter reset button to restore programming. Installation: Power: Supply power and ground to terminals marked and on the terminal block. Mounting: Use supplied hardware to attach FA404 or FA404R housing to wall or surface. To route wiring out the back of the unit, use a small side cutter or utility knife to remove the knockout in the housing base. Opening the housing: Reset Button Access Cover: Insert small screwdriver in slot on left side. Hold cover lightly while prying. Install by inserting top latch and snapping in at bottom. ACTIVATED TAMPERED LOW BATTERY INACTIVE Frequency Agile Receiver by Inovonics Corporation Insert a small flat screwdriver behind pry point indicator nubs on top or bottom of the housing cover (4 places). Gently pry or twist the housing cover apart. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 3 02327C.DOC 8-Oct-01

Programming Alarm Output Configuration: 1) Select alarm output trip options according to the following table. Set jumpers on the OUTPUT CONFIGURATION SELECTOR as indicated. Pins 1-2 Pins 3-4 Output Trip Mode Off Off Follow On Off Momentary (Output will remain on for 4 to 10 seconds from last alarm transmission. Output will stay on during continuous alarm transmissions.) Off On Latch On On Toggle (After releasing the button allow at least 5 seconds between transmissions to toggle devices on and off.) WARNING: Do not use the FA404 toggle mode in applications requiring precision control or timing. Programming transmitters: 1) Select Normally Open (NO) or Normally Closed (NC) transmitter contact by positioning the jumper on the receiver's 3-pin transmitter external contact selector. 2) Plug programming cable to 3-pin TRANSMITTER PROGRAMMING HEADER on the receiver. Orientation of the cable connnector to the header pins makes no difference. 3) Press the TRANSMITTER PROGRAMMING BUTTON on the receiver. Hold for at least 1 second to select the transmitter. The receiver goes into program mode. Continue pressing until the desired transmitter is selected (1-4). A flashing LED indicates that a point has not been previously programmed. Program mode ends as soon as the transmitter is programmed or times out after 30 seconds. 4) Connect the programming cable to 3-pin header on transmitter. Orientation of the connector to header pins does not matter. 5) Press the transmitter reset button for at least 2 seconds. (Refer to pages 6 and 7 for locations of transmitter reset buttons.) 6) If programming is successful, the program point LED will change from flashing to steady when the reset button is released. Note: Any combination of or transmitters can be programmed. Replacing one transmitter with another: 1) Before programming a new transmitter to a previously used point, delete the first transmitter as shown below. 2) Pull the battery from the first transmitter to prevent it from continuing to transmit with the same point identification. 3) WARNING: Inovonics strongly advises against using more than one transmitter per point. Discrete supervision is lost and the possibility exists that alarm transmissions might be missed or cancelled by concurrent restoral or supervisory signals from identically programmed transmitters. Deleting a transmitter: 1) Press the TRANSMITTER PROGRAMMING BUTTON on the receiver to select the transmitter point number. 2) Press the RESET / DELETE BUTTON. This instructs the receiver that there is no longer a transmitter programmed to the point. The LED will change from steady to flashing when the point is deleted. NOTE: Transmitters which have been programmed to the receiver but which are subsequently removed or not used must be deleted from the system to prevent occurrence of Inactive fault in 4 hours. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 4 02327C.DOC 8-Oct-01

Receiver Operation: Output activation: The FA404 has open collector Alarm and Fault outputs. Output is open relative to ground. On activation, output pulls to common ground. The FA404R has Form C Alarm and Fault relay outputs. Output activation is indicated by illumination of the ACTIVATED LED. Note: if a receiver is being connected to a normally closed zone, the FA404R must be used. Connection to hardwire panels: When an FA404 or FA404R receiver is used with a hardwire security panel, the panel will typically supply power and ground to the receiver. When the ground supplied to the receiver is common to the return loops of the hardwire panel, use one wire to connect each of the FA404 receiver outputs to the zone input of the panel. Supervision resistors in loops must be placed in parallel. Supervision resistance in loops must be in series. The examples below show typical connections of both the FA404 and the FA404R. PANEL FA404R, configuration PANEL FA404R, configuration NOTE: GROUND AND RETURNS ARE NOT MON. NOTE: GROUND AND RETURNS ARE NOT MON. DC GROUND DC GROUND FAULT SUPERVISION ZONE FAULT ZONE RETURN ALARM ZONE RETURN ALARM ZONE FAULT ALARM FAULT ZONE RETURN FAULT ZONE ALARM ZONE ALARM ZONE RETURN FAULT ALARM EOL resistors, if required for configuration EOL resistors, if required for configuration PANEL FA404 NOTE: GROUND AND RETURNS ARE MON. DC GROUND RETURN FAULT SUPERVISION ZONE ALARM ZONE FAULT ALARM EOL resistors, if required WARNING: To clear a latched fault or alarm, press RESET. Make sure that the receiver is not in program mode or the transmitter will be deleted. Test all transmitters prior to leaving the site. If the panel has zones and can recognize 3 zone conditions (open=fault, short=alarm and EOL resistance=normal), both the alarm and the fault outputs can be attached to the same zone as shown below. PANEL FA404R, 3-WAY CONFIGURATION NOTE: GROUND AND RETURNS ARE NOT MON. DC GROUND ZONE INPUT MON FAULT ALARM Resistor provided with hardwire panel 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 5 02327C.DOC 8-Oct-01

FA200 Universal Transmitter Frequency Agile Series Transmitters FA200W Universal Widegap Transmitter FA202 Smoke Detector Reset Button Programming Header Batte r y Programming header Widegap reed switch B attery Programming header Widegap Magnet not supported by the FA404 Battery terminals Battery terminals Program contacts: or, as needed Typical battery life: 3 years Battery type: 4.5V alkaline battery pack Dimensions: 1.25" x 6.00" x 0.750" Program contacts: or, as needed Internal contact: not supported by FA404 Typical battery life: 3 years Battery type: 4.5V alkaline battery pack Dimensions: 1.25" x 6.00" x 0.750" Program contacts: Typical battery life: 1 year 2 Batteries: 3V lithium Dimensions: 6.0" Diameter Note: Remove jumper to program, replace jumper after programming. FA203 Pendant Transmitter FA204 Pendant Transmitter FA205 Beltclip Transmitter 3.0V + + 3.0V 3.0V + Program contacts: Typical battery life: 3-5 years Battery (or equivalent): 3.0V lithium Sanyo CR2 Dimensions: 3.10" x 1.62" x 0.750" * To extend battery life, actual check-in interval of the FA203 is 2 to 3 times the programmed value. Programming header Note: Remove battery cover to access Reset Button and Programming Head Program contacts: Typical battery life: 2 years Battery 3.0V Sanyo LiMn CR14250 Dimensions: 2.8" x 1.7" x 0.83" Program contacts: Typical battery life: 3-5 years Battery (or equivalent): 3.0V lithium Sanyo CR2 Dimensions: 3.10" x 1.62" x 0.750" * To extend battery life, actual check-in interval of the FA205 is 2 to 3 times the programmed value. FA206S PIR Motion Detector FA206DS PIR Motion Detector FA207 Glassbreak Detector 1-zone or 2-zone detection header + 3.0V Battery Programming header Sensitivity selector 3.0V + Walk test LED (with tamper shunt) + 3.0V Program contacts: Typical battery life: 2 years Battery: 3.0V lithium Duracell DL123A Sleep after trip: 90-103 seconds Dimensions: 3.75" x 2.88" x 2.40" Mirror Optics Program contacts: Typical battery life: 2 years Battery: 3.0V lithium DL123A Sleep after trip: 180 seconds Dimensions: 3.75" x 5.75" x 2.50" Program contacts: Typical battery life: 2 years Battery: 3.0V lithium DL123A Dimensions: 4.25" x 3.12" x 1.63" Note: Remove jumper to program, replace jumper after programming. Note: Batteries are always supervised. Lithium batteries are capacity-tested at 18-hour intervals. Typical battery life is based on 60-second check-in. The transmitter will deactivate 2 weeks after low battery is detected.test weekly. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 6 02327C.DOC 8-Oct-01

FA209 Billtrap Transmitter Frequency Agile Series Transmitters (Continued) FA210 FA210W Reduced-size Reduced-size Universal Transmitter Universal Widegap Transmitter Delay selector 3V LITHIUM 3V LITHIUM Program contacts: Typical battery life: 1-2 years Battery type (Qty. 2): 3.0V lithium CR2450N Dimensions: 2.63" x 6.19" x 0.750" + 3.0V Program contacts: or, as needed Typical battery life: 4 years Battery type: 3.0V lithium DL123A Dimensions: 3.55" x 1.70" x 0.920" Widegap Magnet not supported FA210W Widegap Reed switches + 3.0V by the FA404 Reed switch indicator Program contacts: or, as needed Internal contact: not supported by FA404 Typical battery life: 4 years Battery type: 3.0V lithium DL123A Dimensions: 3.55" x 1.70" x 0.920" FA250 High PowerTransmitter Tamper Switch 3.0V + Reset Button Programming Header External contact Terminals Program contacts: or, as needed Typical battery life: 1-2 years Battery type: 3.0V lithium DL123A Dimensions: 1.25" x 6.00" x 0.750" Note: Batteries are always supervised. Lithium batteries are capacity-tested at 18-hour intervals. Typical battery life is based on 60-second check-in. The transmitter will deactivate 2 weeks after low battery is detected.test weekly. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 7 02327C.DOC 8-Oct-01

Warranty & Disclaimer Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of twenty-four (24) months from the date of manufacture. Within the warranty period Inovonics will repair or replace, at its option, all or any part of the warrantied product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", "Installer" or "Consumer") must be given a Return Material Authorization ("RMA") Number by Inovonics. Details of shipment will be arranged at that time. This warranty does not apply in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than Inovonics. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied, including any warranty of merchantability or fitness for a particular purpose. Inovonics will not be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties. This warranty will not be modified, varied or extended. Inovonics does not authorize any person to act on its behalf to modify, vary or extend this warranty. This warranty will apply to Inovonics Products only. All other products, accessories or attachments used in conjunction with Inovonics equipment, including batteries, will be covered solely by their own warranty, if any. Inovonics will not be liable for any direct, incidental or consequential damage or loss whatsoever, caused by the malfunction of Product due to products, accessories, or attachments of other manufacturers, including batteries, used in conjunction with Inovonics Products. This warranty does not warrant the replacement of batteries that are used to power Inovonics Products. The User recognizes that a properly installed and maintained security system may only reduce the risk of events such as burglary, robbery, personal injury and fire. It does not insure or guarantee that there will be no death, personal damage and/or damage to property as a result. Inovonics does not claim that the Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. Inovonics shall have no liability for any death, injury or damage, however incurred, based on a claim that Inovonics Products failed to function. However, if Inovonics is held liable, directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, Inovonics' maximum liability will not in any case exceed the purchase price of the Product, which will be fixed as liquidated damages and not as a penalty, and will be the complete and exclusive remedy against Inovonics.! Warning: The User should follow all installation, operation and maintenance instructions. The User is strongly advised to conduct Product and systems tests at least once each week. Changes in environmental conditions, electric or electronic disruptions and tampering, may cause the Product to not perform as expected.! Warning: Inovonics warrants its Product to the User. The User is responsible for exercising all due prudence and taking necessary precautions for the safety and protection of lives and property wherever Inovonics Products are installed. Inovonics strongly advises the User to program Products to be supervised whenever used in applications affecting life safety. Users are warned that unsupervised devices are subject to undetected failure due to malfunction, battery failure, tampering, or changes in environment. 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 8 02327C.DOC 8-Oct-01

Frequency Agile Receivers from Inovonics: FA401 FA401R FA404 FA404R FA416 FA416D FA416R FA416DR FA464DR Single Transmitter / Single Output Single Transmitter / Single Relay Output 4-Transmitter / Single Output 4-Transmitter / Single Relay Output 16-Transmitter / 4-output 16-Transmitter / 4-output with display 16-Transmitter / 4-relay output 16-Transmitter / 4-relay output with display 64-Transmitter / 16-relay output with display Receiver Accessories: FA116 FA516 Executive Programmer for FA416 / FA464 Display module for FA416 and FA416R Inovonics Wireless Corporation 315 CTC Blvd Louisville CO 80027 (800)782-2709 FAX: (303)939-8977 E-MAIL: support@inovonics.com www.inovonics.com 1998 Inovonics Wireless Corporation LIT-FA404-INSTALL 9 02327C.DOC 8-Oct-01