Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Similar documents
Reducing Magnetic Interaction in Reed Relay Applications

Reed Relay Applications

Application Alley. Automated Test Equipment - Reed Relays. Pulsed High Current Testing Applications use Reed Relays PARTNER SOLVE DELIVER

Reed Switch Catalogue

Lecture (10) Power Amplifiers (2)

UNDERSTANDING HORIZONTAL OUTPUT STAGES OF COMPUTER MONITORS

Magnetic Switches. General Information on BERNSTEIN Magnetic Switches. Electromechanical and electronic variants

DISCONTINUED PRODUCT FOR REFERENCE ONLY COMPLEMENTARY OUTPUT POWER HALL LATCH 5275 COMPLEMENTARY OUTPUT POWERHALL LATCH FEATURES

Electromechanical Printed Circuit Board Relays Application Data

Application Information

Demagnetization of Power Transformers Following a DC Resistance Testing

Technical Information General Purpose Relays

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC

Diode Characteristics and Applications

Custom Resistors for High Pulse Applications

Electro-optic components and system

REQUIRED SKILLS AND KNOWLEDGE UEENEEG101A. Electromagnetic devices and circuits. Topic and Description NIDA Lesson CARD # Magnetism encompassing:

MK06 Series Reed Sensors for PCB Mounting. MEDER electronic DESCRIPTION APPLICATIONS FEATURES.

Page 1 of 10. Introduction. Inductive Loads and Diode Protection

Inductive Sensors. Fig. 1: Geophone

Chapter 16: Mutual Inductance

Power System Protection Part VII Dr.Prof.Mohammed Tawfeeq Al-Zuhairi. Differential Protection (Unit protection)

MINI ELECTRONIC SIGNALS

Cornerstone Electronics Technology and Robotics I Week 19 Electrical Relays

Product Information. Bipolar Switch Hall-Effect IC Basics. Introduction

Installation Instructions. Oakmont Folding Doors

Autonomous Robot Control Circuit

Experiment (1) Principles of Switching

Importance of Transformer Demagnetization

3185 THRU 3189 HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION FEATURES. ABSOLUTE MAXIMUM RATINGS at T A = +25 C V CC GROUND OUTPUT SUPPLY

The measurement of winding resistance is useful in detecting a number of types of fault in a transformer. Malfunctioning tap changer mechanisms

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

Chapt ha e pt r e r 11 Inductors

Application Alley. Sensors - Laser Welding and Stainless Steel Fabrication. Why Standex-Meder Laser Welding and Stainless Steel Fabrication?

Introduction To Temperature Controllers

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Flyback Converter for High Voltage Capacitor Charging

Inductance, capacitance and resistance

NATIONAL SENIOR CERTIFICATE GRADE 12

Configuration Example of Temperature Control

AG940-07E Digital / Analog / Omnipolar / Bipolar GMR Magnetic Sensor Evaluation Kit

Introduction To Temperature Controllers

TECHNICAL PAPER. Smarter Sensors reduce costs for Motion Control Integrators. David Edeal. Introduction

Construction of a high-voltage Buck-Boost capacitor charger. Transformer and logic

Brown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER

ECET 211 Electric Machines & Controls Lecture 4-2 Motor Control Devices: Lecture 4 Motor Control Devices

2 Features. u High sensitivity. u Stable temperature performance. u Resistant to mechanical stress. u Low power consumption

PARTNER SOLVE DELIVER. Solutions. Capabilities. Facts

Preliminary. MM7100 High-Voltage SPST Digital-Micro-Switch. Product Overview PRELIMINARY DATA SHEET, SEE PAGE 11 FOR DETAILS

Product Catalog. Advanced Magnetic Sensing and Switching Solutions

Monostable multivibrators

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

407 relay - Latching, safety critical, 40 contacts Datasheet

BSNL TTA Question Paper Control Systems Specialization 2007

White Paper. TRIAC Specifications and Recommendations (Turn On Behavior)

Receiver Operation at the Component Level

Wimborne Publishing, reproduce for personal use only

Current transducer FHS 40-P/SP600

Product Information. Latching Switch Hall-Effect IC Basics. Introduction

PRODUCT DESCRIPTION. Technical Advances in Hall-Effect Sensing. Introduction. Past and present Hall-effect sensors

Hello, and welcome to the TI Precision Labs video discussing comparator applications, part 4. In this video we will discuss several extra features

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

ECET 211 Electric Machines & Controls Lecture 7 Relays. Lecture 7 Relays

PART 2 - ACTUATORS. 6.0 Stepper Motors. 6.1 Principle of Operation

EEE3410 Microcontroller Applications Department of Electrical Engineering Lecture 11 Motor Control

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

Half stepping techniques

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

ELM334 Garage Doorman

Long Loopstick Antenna

DISCUSSION OF FUNDAMENTALS

ENGINE GOVERNING SYSTEMS LSM200 SERIES LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Nuclear Qualified Control Relays Series EGP/EML/ETR

Switch-on-to-Fault Schemes in the Context of Line Relay Loadability

Experiment#6: Speaker Control

Dynamic calculation of nonlinear magnetic circuit for computer aided design of a fluxgate direct current sensor

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

Bulletin 700-R -RM Sealed Switch Relays

ZERO-SPEED, SELF-CALIBRATING, NON-ORIENTED, HALL-EFFECT GEAR-TOOTH SENSOR IC

Product Catalog. Advanced Switching and Magnetic Sensing Solutions

Electrical Controls. Isaac Queen

CHAPTER 13 REVIEW. Knowledge. Understanding

Crystal Radio Engineering Diode Detectors

HAL , 508, 509, HAL , 523 Hall Effect Sensor Family MICRONAS. Edition Feb. 14, E DS

TRANSFORMER CONTROL (AC-56a)

Product Catalog. Advanced Switching and Magnetic Sensing Solutions

MRI SYSTEM COMPONENTS Module One

PROXIMITY SENSORS report the LOCATION of an important item that must be monitored. Whether the DOOR is open or closed, the FLOW on or off, the LEVEL

Diode Bridges. Book page

REDROCK RR120 TMR DIGITAL SENSOR

Product Catalog. Advanced Switching and Magnetic Sensing Solutions

FEBFAN3240_001NDA FEBFAN3241_001NDA Evaluation Boards. FAN324x Smart Dual-Coil Relay Driver Evaluation Board

HAL , 508, 509, HAL Hall Effect Sensor Family

HAL HAL 576, 579 HAL HAL 584

Tech Byte 16: The Truths About Transformers Part 2

Polarized, latching hermetically sealed relay Contact arrangement. 3 PDT Coil supply

Back to the Basics Current Transformer (CT) Testing

Magnetron. Physical construction of a magnetron

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

Transcription:

Standex-Meder Electronics Custom Engineered Solutions for Tomorrow

Form B & Latching Reed Relays & Sensors Product Training Copyright 2013 Standex-Meder Electronics. All rights reserved.

Introduction Table of Contents What are the key features of Form B and latching Relays and Sensors? Why is the magnet so important? Why is the coil so important? The hysteresis of the Reed Switch the best way to understand Form B and latching action

Overview Form B and latching Reed Relays and Sensors all use magnetic biasing. In the case of the Form B the magnets will be biased strong enough to close the contacts. It will take an external magnet of equal strength and opposite polarity to open the Reed Switch in a Sensor Application. In the case of a Form B Relay, it will take a coil of equal and opposite strength to open the contacts. In both cases, no current or external energy is expended when the Reed is in the closed position.

Overview For a latching Sensor or latching Relay the magnet does not bias the Reed Switch so that it is fully closed. It biases the Reed so that it is partially closed, but not making contact. In this case, for a Sensor an external magnet must be brought in aiding the biasing magnet. And for the Relay a latching coil must be connected to aid the biasing magnet to fully close the contacts.

Form B Reed Relay Below a Form B Reed Relay is shown. As shown, no power is required to keep the contacts closed.

Form B Reed Relay the magnet The choice of a suitable magnet is the first step As is the case with Form B and latching, the magnet is placed directly onto the glass of the Reed. In this case only a relatively weak magnetic field is needed to close the contacts. Generally the magnet will not be at full strength. It will be demagnetized to a suitable strength for proper operation. The stable AlNiCo magnets are usually best for the magnetizing and demagnetizing adjustment that needs to take place.

Form B Reed Relay the coil Applying coil power opens the contacts. Care must be taken to make sure the polarity of the coil is maintained so that an opposing field is created negating the magnetic field of the magnet. Here the winding direction of the coil must be consistent, and must be specified in the work instructions. The spec must call out the voltage polarity to the coil. Reversing the coil polarity - the Relay will not function.

Form B Reed Relay the coil Also care must be taken not to make the coil too strong. Why? Too strong a coil will actually cause the contacts to re-close. Generally, applying 50% above the nominal should not re-close the contacts. Actually the use of a shorter magnet will improve the re-closure (requiring a higher coil voltage to be applied for re-closure to occur). Shown here the contacts have re-closed with excessive nominal voltage.

Form B Reed Relay the switch The best way to understand Form B and latching action is to picture the hysteresis of the Reed Switch. This hysteresis is the key component for the proper operation of a Form B and latching. For starters, one needs to select a relatively wide hysteresis reed switch. 50% or below is best. The wider the hysteresis (lower percentage) the easier it is to tune the magnet for proper operation.

Form B Reed Relay proper operation The graph below shows the contact state and how it is influenced by the magnetic fields. First, in this example we have selected a 4 mt pull-in and a 2mT drop-out reed switch (blue lines) (AT?). The magnet is suitably adjusted to apply 5 mt field to the reed switch. This magnetic field is strong enough to close the contacts (its state is shown in stage 1).

Form B Reed Relay proper operation Now in stage 2 the coil is energized applying a magnetic field strength of 4 mt. This magnetic field is opposite the field of the magnet leaving a net field strength of 1 mt. In stage 3 we remove the coil power. The net field strength returns to the 5 mt from the magnet. Can you tell me why the coil has not affected the strength of the magnet?

Form B Reed Relay proper operation Based on this example in the graph, can you tell me what coil field strength is needed to create a re-closure of the contacts? 10 mt In this graph you can see how the closure and opening operate directly above and below the hysteresis of the reed switch. Again its worth pointing out the importance of the reed switch hysteresis.

Latching Relays This graph shows the relationship of pull-in, drop-out and hysteresis for a group of reeds with various mt sensitivities.

Latching Relays The points we discussed for Form B relay almost all carry over to the latching relay. The significant difference to change the state of the reed switch, only a pulse of 1 millisecond to 1.5 milliseconds needs to be applied across the coil. Secondly, usually a bifilar coil is used, where one coil closes the contacts and the other coil opens the contacts. This is accomplished by using opposite polarities to each coil. One can use only one coil. However, it requires our customer to have the ability to apply a positive polarity to the coil, and then have the ability to apply a negative polarity to the same coil. In this case, the magnetic polarity is reversed.

Latching Relays As seen here, a voltage pulse is applied to the coil generating an aiding field to the magnet closing the contacts. As seen here a second coil of equal and opposite polarity is used to generate a magnetic field opposite to the one that latched the coil and thereby opening the contacts.

Latching Relays proper operation Again, the best way to understand what is happening is look at each of the stages as in the example below. As you can see from the graph we use a reed switch with a pull-in of 4 mt and a drop-out of 2 mt. Here in stage 1, we show the magnet has applied a magnetic field strength of 3 mt to the switch, which is not enough to close the contacts. In stage 2 a latching pulse of 2 mt is applied through the latching coil to the reed switch.

Latching Relays proper operation This latching magnetic field aids the existing magnetic field from the permanent magnet combining for a net field strength of 5 mt. This added field is sufficient to close the contacts. In stage 3 we now see the net magnetic field after the latching pulse in gone is back to 3 mt. However, in this case, the contacts stay closed, because the field strength never dropped below the drop out level of the contacts at 2 mt.

Latching Relays proper operation In stage 3, the contacts will stay at this level for as long as the customer would like, and with the added benefit of no power being used. In stage 4 an unlatching coil pulse of 2 mt is applied to the contacts opposite in polarity to the latch pulse. Now the net field strength is reduced to 1 mt. As can be seen this is now below the drop-out level of the reed switch. The contacts open.

Latching Relays proper operation Stage 5 shows the resultant magnetic field left after the unlatching pulse is gone. The field is back to the beginning field of 3 mt that is generated by the permanent magnet. As can be seen the hysteresis of the reed switch plays a key role in accomplishing a good latching relay. They relay uses minimal power. Latching relays as can be seen use relatively week coils to accomplish their task.

Latching Relays proper operation Do we need to worry about the re-closure? As stated, these coils are very weak, so it would take a very large voltage to effectively create a strong enough field. And since it is only a pulse the effect would be gone anyway. Furthermore, using higher voltages would not make sense in an energy conscious design.

Form B Reed Sensors Form B reed sensors follow the same rules as with the Form B relay. We start with a magnet that has been magnetized to a suitable level closing the contacts.

Form B Reed Sensors Here a magnet of opposite polarity is brought into the existing magnetic field canceling it out and thereby opening the contacts. Care must be taken not to use too strong a magnet, otherwise the contacts may re-close. Also, care must be taken in selecting which operate and release magnetic lobe one is using, since there are physically several operate and release lobes to contend with.

Form B Reed Sensors Removing the second magnet, the contacts revert back to their initial closed state. Using high mt pull-in switches may give the most stable conditions. The higher pull-in mt will give a wider hysteresis. The customer design criteria is most important and should direct the details of the design.

Form B Reed Sensors A latching reed sensor needs to follow the same rules we discussed for a latching reed relay. We need to use a biasing magnet biasing that is below pull-in mt level of the reed switch. Therefore the reed switch remains in the open state.

Form B Reed Sensors Applying a second magnet with an aiding field complementing the first magnet will close the contacts.

Form B Reed Sensors Removing the second magnet, the contacts will remain in the closed state.

Form B Reed Sensors Applying the second magnet with its field reversed will now open the contacts.

Form B Reed Sensors Removing the second magnet the contacts remain in the open state Using high mt pull-in switches may give the most stable conditions. The higher pull-in mt will give a wider hysteresis.

PARTNER SOLVE DELIVER For more information on our capabilities, and how we can partner, solve, and deliver to your needs, please visit us at www.standexmeder.com