SETION 1 FLUSH INSET INSTLLTION SETION 2 STNR INSTLLTION 1/4" FRME PNELS 3/4" OVERLY PNELS
OVERLL IMENSIONS FTER PNEL INSTLL FLUSH INSET INSTLLTION 38" (96.5) 26" (66.0) 20 5/8" (52.4) 11 1/2" (29.2) * 84 1/2" (214.6) *73" (185.4) * 8 (212.1) SPEIFITIONS Overall Width 38" (96.5 cm) Overall Height 84 1/2" (214.6 cm) Overall epth 26" (66.0 cm) oor learance utout Width utout Height utout epth Plumbing Requirements Shipping Weight 38 3/4" (98.4 cm) 39" (99.1 cm) 85" (215.9 cm) 26 3/16" (66.5 cm) 1/4" O copper tubing or GE Smartonnect kit 640 lb (290.3 kg) *26 7/16" (67.1) FRONT VIEW *4" *4" (10.2) * Shipping height. Use leveling legs and wheels for maximum 1" height adjustment from shipping height. Nominal installation height is 84 35" (89.0) ase width (10.2) SIE VIEW ** llow 15" (38.1) min clearance for 115 door swing imensions include 3/4" custom cabinet panel TTENTION ELETRIIN: 115 volt 60Hz., 15 or 20 amp power supply is required. n individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. 38 3/4" (98.4) TOP VIEW ** llow 4" (10.2) min clearance to a wall for 90 door swing ** These refrigerators are equipped with a 2-position door stop. The factory-set 115 door swing can be adjusted to 90 if clearances to adjacent cabinets or walls is restricted. llow a 15" minimum clearance to wall for pan removal. If the 90 door stop position is used, pan access is maintained, but pan removal is restricted. imensions in parentheses are in centimeters unless otherwise noted. ctual product dimensions may vary due to manufacturing tolerances.
FLUSH INSET INSTLLTION 3/4" PNELS 85" (215.9) 26 3/16" (66.5) Flush inset depth 20 15/16" (53.2) epth to cleat Finished cleats W SIE VIEW NTI-TIP RKET 82" (208.3) 5 1/4" (13.3) 3/4" (1.9) Width of side cleats 85" (215.9) height to cleat Use two additional hole locations at end of brackets 3/4" TOP VIEW Finished cleats ase Trim ase oor 39" (99.1) Flush inset width 37 1/2" (95.3) Width between cleats 7" (17.8) ELE. 10" (25.4) WTER (9.0) 6" (15.2) 24 3/16" (61.4) FRONT VIEW L racket mounted into vertical wall studs centered within the cutout Ensure holes selected are centered on the studs Wall Studs 7" (17.8) 1/2" (1.3) 75 1/2" (191.8 ) From floor to bottom of electrical area FLUSH INSET INSTLLTION Mounting the junction box in this location will also allow for front accessibility through access panel. Water supply area. WRNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the antitip system you must use the product installation instructions. The information below applies to all installation constructions: wall bracket, bolts and toggles will be supplied with the unit. The bolts will be used to attach bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. In installation opening, measure 82" from floor and draw a horizontal line. Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32.5" of installation opening to ensure 2 wall studs are penetrated. The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied L bolts. See Installation Instructions for detailed instructions. SIE VIEW INSTLLE WITH NTI-TIP RKET FRONT VIEW OF UTOUT WITH NTI-TIP RKET
FLUSH INSET 3/4" PNEL IMENSIONS SINGLE INSTLLTION Grille Freezer rawer 3/4" RISE OOR PNEL ROUTING 11/32" 1/4" ETIL TOP 3/4" 1/4" 9/16" PNEL IMENSIONS 38" 10 11/16" 46 9/16" 22 7/16" NOTE: Routed areas should be finished as they may be visible when assembled. ack TOP FLUSH INSET INSTLLTION Trimmed refrigerators are designed to be customized with decorative panels. Fieldinstalled 1/2" or 3/4" custom door, drawer and grille panels are required. For 3/4" raised panels, routing is required. The router depth is 1/4" all the way around the panel s backs. dditional panel width reductions are required per the diagrams shown. This will create picture frame routing allowing the panels to slide into the attached door, drawer and grille trims. Maximum total panel weight: food door panels 58 lbs. Freezer drawer panel 28 lbs. Grille panel 11 lbs oor Handles oor handles not included. ustom handles supplied by your cabinet maker may be used. ZKHPSS1: Professional tubular stainless steel handle designed to fit custom panels. Kit includes one handle 30 1/2" long. Order 2 kits from your Monogram supplier. ZKHSS2: ustom European tubular handle designed to fit custom panels. Kit includes 2 handles. oor handle is 44 3/16" and drawer handle is 33 3/16". Order ZUG2: Unified grille kit for dual installation. Maximum total panel weight - 25 lbs. ZKHT: Handle side trim for left-hand and right-hand door. For use on a custom panel when using a custom handle. ack 3/16" ETIL OTTOM ORNER VIEW SHOWING PITURE FRME ROUTING ETIL LEFT SIE ETIL RIGHT SIE ROUTER EPTH 1/4" ROUTER EPTH 1/4" 3/32" 1/4" 2-1/16" 2-1/16" LEFT SIE RIGHT SIE ack 3/4" PNEL OTTOM VIEW (FTER ROUTING) OTTOM 3/4" PNEL SIE VIEW (FTER ROUTING)
3/4" RISE GRILL PNEL ROUTING ETIL TOP NOTE: Routed areas should be finished as they may be visible when assembled. TOP FLUSH INSET INSTLLTION 1-11/16" 3/16" LEFT SIE ROUTER EPTH 1/4" ETIL LEFT SIE ROUTER EPTH 1/4" ROUTER EPTH 1/4" 2-1/16" 2-1/16" ack 3/4" PNEL OTTOM VIEW (FTER ROUTING) 3/4" raised rawer Routing 11/32" 1/4" ETIL TOP 3/4" 1/4" 9/16" ack ORNER VIEW SHOWING PITURE FRME ROUTING NOTE: Routed areas should be finished as they may be visible when assembled. ETIL RIGHT SIE 3/32" 1/4" RIGHT SIE ack OTTOM 3/4" PNEL SIE VIEW (FTER ROUTING) TOP Trimmed refrigerators are designed to be customized with decorative panels. Fieldinstalled 1/2" or 3/4" custom door, drawer and grille panels are required. For 3/4" raised panels, routing is required. The router depth is 1/4" all the way around the panel s backs. dditional panel width reductions are required per the diagrams shown. This will create picture frame routing allowing the panels to slide into the attached door, drawer and grille trims. Maximum total panel weight: food door panels 58 lbs. Freezer drawer panel 28 lbs. Grille panel 11 lbs oor Handles oor handles not included. ustom handles supplied by your cabinet maker may be used. ZKHPSS1: Professional tubular stainless steel handle designed to fit custom panels. Kit includes one handle 30 1/2" long. Order 2 kits from your Monogram supplier. ZKHSS2: ustom European tubular handle designed to fit custom panels. Kit includes 2 handles. oor handle is 44 3/16" and drawer handle is 33 3/16". Order ZUG2: Unified grille kit for dual installation. Maximum total panel weight - 25 lbs. ZKHT: Handle side trim for left-hand and right-hand door. For use on a custom panel when using a custom handle. ack ack 3/16" ETIL OTTOM ORNER VIEW SHOWING PITURE FRME ROUTING ETIL LEFT SIE ETIL RIGHT SIE ROUTER EPTH 1/4" ROUTER EPTH 1/4" 2 1/16" 2 1/16" LEFT SIE RIGHT SIE OTTOM ack 3/4" PNEL OTTOM VIEW (FTER ROUTING) 3/4" PNEL SIE VIEW (FTER ROUTING)
FLUSH INSET INSTLLTION 1/2" PNELS 85" (215.9) 26 3/16" (66.5) Flush inset depth 20 13/16" (52.9) epth to cleat Finished cleats W SIE VIEW NTI-TIP RKET 82" (208.3) 5 3/8" (13.7) 3/4" (1.9) Width of side cleats 85" (215.9) height to cleat Use two additional hole locations at end of brackets 1/2" TOP VIEW ase Finished cleats ase Trim 39" (99.1) Flush inset width 37 1/2" (95.3) Width between cleats 7" (17.8) ELE. 10" (25.4) oor 6" (15.2) 24 3/16" (61.4) FRONT VIEW L WTER (9.0) racket mounted into vertical wall studs centered within the cutout Ensure holes selected are centered on the studs Wall Studs 7" (17.8) 1/2" (1.3) 75 1/2" (191.8 ) From floor to bottom of electrical area FLUSH INSET INSTLLTION Mounting the junction box in this location will also allow for front accessibility through access panel. Water supply area. WRNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the antitip system you must use the product installation instructions. The information below applies to all installation constructions: wall bracket, bolts and toggles will be supplied with the unit. The bolts will be used to attach bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. In installation opening, measure 82" from floor and draw a horizontal line. Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32.5" of installation opening to ensure 2 wall studs are penetrated. The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied L bolts. See Installation Instructions for detailed instructions. SIE VIEW INSTLLE WITH NTI-TIP RKET FRONT VIEW OF UTOUT WITH NTI-TIP RKET
FLUSH INSET 1/2" PNEL IMENSIONS Grille Freezer rawer PNEL IMENSIONS 1/4" acker 33 7/8" 8 7/8" 46 1/16" 21 7/8".10" Space 32 1/2" 7 5/8" 44 11/16" 20 1/2" 1/2" Overlay 38" 10 11/16" 46 9/16" 22 7/16" FLUSH INSET INSTLLTION The 1/2" overlay panel must be secured to a.10" spacer panel and a 1/4" thick backer panel, which slides into the trim. ssemble the panels with glue and screws: enter the spacer panel on the backer panel, left to right and top to bottom. Secure the panels with glue. Refer to the chart for locating the backer panel to the overlay panel. Secure the overlay panel to the backer panel with glue and screws. Screws must be countersunk into the backer panel Order ZUG2: Unified grille kit for dual installation. Maximum total panel weight 25 lbs. 1/2" OVERLY PNEL ROUTING IMENSIONS Grille ack oor 1/2" Overlay Hinge Side /Freezer ack 1/4" acker.10" Spacer acker with Overlay ssembly PNEL IMENSIONS 2 1/16" 2 1/16" 5/16" 3/16" Freezer 2 1/16" 2 1/16" 5/16" 3/16" Grille 2 1/16" 2 1/16" 1 11/16" 3/16" Freezer rawer
FLUSH INSET 3/4" PNEL imensions dual installation Freezer rawer Grille PNEL IMENSIONS E Freezer rawer E 74 1/2" 10 11/16" 46 9/16" 22 7/16" 36 7/8" FLUSH INSET 1/2" PNEL IMENSIONS UL INSTLLTION Grille FLUSH INSET INSTLLTION Trimmed refrigerators are designed to be customized with decorative panels. Fieldinstalled 1/2" or 3/4" custom door, drawer and grille panels are required. For 3/4" raised panels, routing is required. The router depth is 1/4" all the way around the panel s backs. dditional panel width reductions are required per the diagrams shown. This will create picture frame routing allowing the panels to slide into the attached door, drawer and grille trims. Maximum total panel weight: food door panels 58 lbs. Freezer drawer panel 28 lbs. Grille panel 11 lbs oor Handles oor handles not included. ustom handles supplied by your cabinet maker may be used. ZKHPSS1: Professional tubular stainless steel handle designed to fit custom panels. Kit includes one handle 30 1/2" long. Order 2 kits from your Monogram supplier. ZKHSS2: ustom European tubular handle designed to fit custom panels. Kit includes 2 handles. oor handle is 44 3/16" and drawer handle is 33 3/16". Order ZUG2: Unified grille kit for dual installation. Maximum total panel weight - 25 lbs. ZKHT: Handle side trim for left-hand and right-hand door. For use on a custom panel when using a custom handle. E The 1/2" overlay panel must be secured to a.10" spacer panel and a 1/4" thick backer panel, which slides into the trim. ssemble the panels with glue and screws: enter the spacer panel on the backer panel, left to right and top to bottom. Secure the panels with glue. Freezer rawer Freezer rawer Refer to the chart for locating the backer panel to the overlay panel. Secure the overlay panel to the backer panel with glue and screws. Screws must be countersunk into the backer panel PNEL IMENSIONS Order ZUG2: Unified grille kit for dual installation. Maximum total panel weight 25 lbs. E 1/4" acker 69 7/8" 8 7/8" 46 1/16" 21 7/8" 33 7/8".10" Space 68 1/2" 7 5/8" 44 11/16" 20 1/2" 32 1/2" 1/2" Overlay 74 1/2" 10 11/16" 46 9/16" 22 7/16" 36 7/8"
3/4" or 1/2" UL INSTLLTIONS FLUSH INSET INSTLLTION 4 5/16" (10.9) 75 1/2" (191.8) Finished Width 24 3/16" (61.4) 26 3/16" (66.5) Min. utout epth 85" (215.9) Finished Opening ELE. 5 1/2" ELE. 5 1/2" 9" (22.9) (13.9) 9" (22.9) (13.9) separate 115V, 60Hz, 15- or 20-amp power supply is recommended for each product. In a side-by-side installation of a left-andright-hand door swing product, 1 1/2" clearance between the units is required. Order ZUG2 custom panel unified grille kit for this installation. 75 1/2" (191.8 ) From floor to bottom of electrical area 7" (17.8) WTER (9.0) 7 1/2" (19.1) 7 1/2" (19.1) WTER (9.0) 7" (17.8) W FRONT VIEW SIE VIEW 3/4" or 1/2" UL PROUT LERNES 15" (38.1) min To wall 1 1/2" (3.8) 15" (38.1) min To wall 115 oor swing 115 oor swing
OVERLL IMENSIONS FTER PNEL INSTLL STNR INSTLLTION 25 1/4" (64.1) 36" (91.5) 23 7/8" (60.7) 9 7/8" (25.1) 1 7/8" (4.8) *73 1/4" (186.1) 46 1/4" (117.5) *84" (213.4) *8 (212.1) SPEIFITIONS Overall Width Overall Height Overall epth oor learance utout Width 36" (91.4 cm) 84" (213.4 cm) 25 3/8" (64.5 cm) 36 3/4" (93.4 cm) 35 1/2" (90.2 cm) utout Height 8-84 1/2" (212.1-214.6 cm) utout epth Plumbing Requirements Shipping Weight 24" (61 cm) 1/4" O copper tubing or GE Smartonnect kit 640 lb (290.3 kg) *26 1/2" (67.3) FRONT VIEW 35" (89.0) ase width *24 1/8" (61.3) *26" (66.0) * Shipping height. Use leveling legs and wheels for maximum 1" height adjustment from shipping height. 35" (89.0) *3 5/8" (9.2) SIE VIEW ** llow 25" (63.5) min clearance for 130 door swing TTENTION ELETRIIN: 115 volt 60Hz., 15 or 20 amp power supply is required. n individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. 36 3/4" (93.4) TOP VIEW ** llow 4" (10.2) min clearance to a wall for 90 door swing ** These refrigerators are equipped with a 2-position door stop. The factory-set 130 door swing can be adjusted to 90 if clearances to adjacent cabinets or walls is restricted. llow a 15" minimum clearance to wall for pan removal. If the 90 door stop position is used, pan access is maintained, but pan removal is restricted. imensions in parentheses are in centimeters unless otherwise noted. ctual product dimension may vary due to manufacturing tolerances.
STNR INSTLLTION TOP VIEW STNR INSTLLTION 3 1/8" 24" (61) (7.93) 35 1/2" (90.2) 7/16" (1.1) 1 9/16" Trim overlap 2 5/16" (3.97) (5.874) Mounting the junction box in this location will also allow for front accessibility through access panel. Water supply area. SIE VIEW NTI-TIP RKET W 82" (208.3) *84 1/2" (214.6) *Trim will overlap additional 7/16" Use two additional hole locations at end of brackets ELE. 5" (12.7) 10" (25.4) 6" (15.24) WTER (9.0) 5" FRONT VIEW L racket mounted into vertical wall studs centered within the cutout Ensure holes selected are centered on the studs Wall Studs (12.7) 75" (190.5 ) From floor to bottom of electrical area WRNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the anti-tip system you must use the product installation instructions. The information below applies to all installation constructions: wall bracket, bolts and toggles will be supplied with the unit. The bolts will be used to attach bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. In installation opening, measure 82" from floor and draw a horizontal line. Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32.5" of installation opening to ensure 2 wall studs are penetrated. The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied L bolts. See Installation Instructions for detailed instructions. SIE VIEW INSTLLE WITH NTI-TIP RKET FRONT VIEW OF UTOUT WITH NTI-TIP RKET
STNR 1/4" FRME PNEL IMENSIONS SINGLE INSTLLTION STNR INSTLLTION PNEL SSEMLY ROSS SETION Grille oor Supplied Handles Trim 1/4" Framed Trimmed refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required. 1/4" Framed s: For 1/4" thick custom panels ordered from your cabinet maker. The decorative panels slide into the trim. Maximum total panel weight: food door panel 58 lbs. Freezer drawer panel 28 lbs. Grille panel 11 lbs. Freezer rawer PNEL IMENSIONS 1/4" Framed 33 7/8" 8 7/8" 46 1/16" 21 7/8" STNR 3/4" OVERLY PNEL IMENSIONS SINGLE INSTLLTION Grille Freezer rawer PNEL SSEMLY ROSS SETION oor 3/4" Overlay Supplied Handles PNEL IMENSIONS 1/4" acker 33 7/8" 8 7/8" 46 1/16" 21 7/8".10" Spacer 32 1/2" 7 5/8" 44 11/16" 20 1/2" 3/4" Overlay 34 1/8" 9" 46 5/16" 22".25" +.10" +.75" = 1.10" Total Thickness Trim 1/4" acker.10" Spacer 3/4" Overlay s: The decorative panels slide into the trim. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. spacer panel 0.10" thick must be placed between the overlay and backer panels. enter each panel over the other. ssemble the panels with glue and screws. Screws must be countersunk into the backer panel. NOTE: Left-to-right offset is not always equal to top-to-bottom offset. Maximum total panel weight: food door panel 58 lbs. Freezer drawer panel 28 lbs. Grille panel 11 lbs. oor Handles: The supplied handles can be adjusted to accommodate both framed or overlay panels. ustom handles of your choice, supplied by your cabinet maker, can also be installed. ZKHPSS1: Professional tubular stainless steel handle designed to fit 3/4" overlay panels. ZKHSS2: European tubular handle designed to fit 3/4" panels. Kit includes 2 handles. oor handle is 44 3/16" and drawer handle is 33 3/16".
USTOM SIE PNELS F 1 7/8" (4.8) 24" (61.0) 3/16" (.5) *84 *84" (213.4) *epending on installation height STNR INSTLLTION F Side panels must be used whenever the sides of the refrigerator will be exposed. The 1/4 side panels will slip into the side case trim. Secure the panels to the refrigerator with stick-on hook and loop fastener strips. Order the side panels from the cabinet manufacturer. *3" - 4" (7.6-10.2) *epending on installation height 2 9/16" (6.5)
STNR 1/4" FRME PNEL IMENSIONS UL INSTLLTION Freezer rawer Grille E Freezer rawer PNEL IMENSIONS 1/4" Framed 69 7/8" 8 7/8" 46 1/16" 21 7/8" E 33 7/8" STNR INSTLLTION Trimmed refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required. 1/4" Framed s: For 1/4" thick custom panels ordered from your cabinet maker. The decorative panels slide into the trim. Maximum total panel weight: food door panel 58 lbs. Freezer drawer panel 28 lbs. Grille panel 25 lbs. Order ZUG2: Unified grille kit for dual installation PNEL SSEMLY ROSS SETION oor Trim Supplied Handles 1/4" Framed 3/4" Overlay s: STNR 3/4" OVERLY PNEL IMENSIONS UL INSTLLTION Freezer rawer PNEL SSEMLY ROSS SETION Grille E Freezer rawer oor PNEL IMENSIONS 1/4" acker.10" Spacer 3/4" Overlay 69 7/8" 68 1/2" 70 1/8" 8 7/8" 7 5/8" 9" 46 1/16" 44 11/16" 46 5/16" 21 7/8" 20 1/2" 22" E 33 7/8" 32 1/2" 34 1/8".25" +.10" +.75" = 1.10" Total Thickness Trim 1/4" acker The decorative panels slide into the trim. The overlay panel must be secured to a 1/4"-thick backer panel which slides into the trim. spacer panel 0.10" thick must be placed between the overlay and backer panels. enter each panel over the other. ssemble the panels with glue and screws. Screws must be countersunk into the backer panel. NOTE: Left-to-right offset is not always equal to top-to-bottom offset. Maximum total panel weight: food door panel 58 lbs. Freezer drawer panel 28 lbs. Grille panel 25 lbs. Order ZUG2: Unified grille kit for dual installation oor Handles: The supplied handles can be adjusted to accommodate both framed or overlay panels. ustom handles of your choice, supplied by your cabinet maker, can also be installed. ZKHPSS1: Professional tubular stainless steel handle designed to fit 3/4" overlay panels. ZKHSS2: European tubular handle designed to fit 3/4" panels. Kit includes 2 handles. oor handle is 44 3/16" and drawer handle is 33 3/16". 3/4" Overlay.10" Spacer Supplied Handles
UL INSTLLTIONS STNR INSTLLTION 2 5/16" (5.9) 8 min 84 1/2" max (212.1-214.6) Finished Opening 71 1/2" (181.6) Finished Width 24 3/16" (61.4) ELE. 6" ELE. 6" 10" (25.4) (15.2) 10" (25.4) (15.2) 75" (190.5 ) From floor to bottom of electrical area 24" (60.9) Min. utout epth separate 115V, 60Hz, 15- or 20-amp power supply is recommended for each product. dditional cutout width may be required when side panels are used. In a side-by-side installation of a leftand-right-hand door swing product, 1" clearance between the units is required. Order ZUG2: custom panel unified grille kit for one continuous grille panel. 5" (12.7) WTER (9.0) 5 3/4" (14.6) 5 3/4" (14.6) WTER (9.0) 5" (12.7) 10" (25.4) WTER FRONT VIEW SIE VIEW UL PROUT LERNES 25" min (63.5) To wall 1" (2.5) 25" min (63.5) To wall 130 oor swing 130 oor swing
FETURES N ENEFITS ustom ppearance - llows personalization with cabinet-compatible panels an custom handles Upfront Electronic ontrols with igital Readout - llows precise temperature settings and are positioned for maximum ease of use Humidity ontrolled Vegetable ompartments and Sealed Snack Pans - Help maintain freshness and help preserve foods longer djustable, Spill Proof Glass Shelves - Make it easy to customize storage to handle foods and containers of various sizes 2 Sealed eli Pans with Full-Extension Slides Six djustable oor ins - Offer added storage flexibility GE Water Filtration System - elivers clean, great tasting ice R