Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Similar documents
Q.raxx A slimline RS / EC

Q.raxx A101-8 slimline RS / EC

Q.raxx A slimline RS / EC Universal Measurement System

B850 Boiler House Energy Monitor

Side view View from below Rear view

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

UMG 509-PRO. Multifunction power analyser with RCM

B850 Boiler House Energy Monitor

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

NEW! AOIP FD5 Advanced Digital Data Logger

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Industrial Modbus I/O Modules

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Transienten. Datenspeicher

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

imc C-SERIES: CS-1016-N, CL-1032-N

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Data sheet CPU 314ST/DPM (314-6CF02)

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

MX1615. Data sheet. Bridge/strain gauge amplifier

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

satech SynchroStar GPS 200 Series

PFXLM4B01 D * * (1) (2) (3) (4)

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

imc C-SERIES: CS-3008-N, CL-3016-N

2A (recommended) Power loss

imc C-SERIES: CS-5008-FD

Data sheet CPU 313SC (313-5BF13)

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Data sheet CPU 013C (013-CCF0R00)

T108, GPS/GLONASS/BEIDOU Time Server

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RS232. DC POWER SUPPLY 20kW 3 RANGES

22 kw 4Q POWER AMPLIFIER RS232

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

PFXLM4201T A D * * (1) (2) (3) (4) (5) (6)

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

MULTIFUNCTION GRAPHICAL UNIT MGU 800

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Product type designation. General information. Supply voltage

USB-2404-UI Specifications

Kistler LabAmp for DynoWare

High Performance Process & Temperature Controllers

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

LAUREL ELECTRONICS, INC.

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Main Features. Highlights

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

T200, PTP/IEEE 1588 Grandmaster Clock and

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

R-Log Radio data logger

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

MULTICHANNEL ACQUISITION SYSTEM

CompactLogix 5370 L3 Control System

Saitel DP. Technical Specifications Tables. The high-performance platform for applications of control and automation. July 2014

FRONTDAQ 20. High speed acquisition module with universal synchronized inputs and embedded webserver software

General information. Supply voltage

Trendmaster * Dynamic Scanning Module

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

On-site multifunction calibrator

SCXI 8-Channel Isolated Analog Input Modules

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Excellent low-cost Process & Temperature Controllers

[ tima-datasheet-en v11.1 ]

SHIMADEN DIGITAL INDICATORS

Temperature Measurement

Your benefits using DTS 4160.grandmaster:

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

MX1615B. Data sheet. Bridge/strain gauge amplifier

DIGITAL PROGRAM CONTROLLER

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

VersaPoint I/O Module

Specifications of PFXLM4301TADAC (Modular Type Analog / Source Output Type)

Brochure nº

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Correlation of Voltage and Temperature Measurement

Transcription:

The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary testing and assembly. The EC version includes a Test Controller that offers the user a powerful solution with PAC functionality, synchronized data acquisition, sequencing, mathematics, combinations a Ethernet TCP/IP interface as well as a EtherCAT fieldbus. It is possible to connect three slimline basic units to the Test Controller of a slimline EC unit. Beside the pre-defined standard versions customized systems regarding numbers of channels, kind of measurement inputs/connectable sensors as well as the required connectors are configurable. This modularity permits to design an optimized individual solution for any application. Further it is possible to mix different product lines like Q.raxx, Q.bloxx within Q.series. Most important features: 16 galvanic isolated input channels thermocouples and voltages in the range of ±80 mv Cold junction compensation Integrated CJC each input High accuracy digitalization 24 bit ADC, 100 Hz sample rate per channel, Dynamic linearization optimized positioning of the interpolation points within the selected range, type B, E, J, K, L N, R, S, T, U Galvanic isolation channels to power supply and to interface, V iso 500 VDC Electromagnetic Compatibility according EN 61000-4 and EN 55011 Power supply 10 30 VDC With embedded Test Controller (version EC): Optional fieldbus interface EtherCAT EtherCAT according specification ETG, 254 read and 254 write variable with 10 khz Ethernet interface for configuration and data output FTP, TCP/IP, UDP FTP Server and FTP Client functionality configurable function High data rate over Ethernet 16 real variables with 10 khz (block transfer) 64 real variables with 300 Hz (online Data buffer memory dyn. 16 MByte (RAM), stat. 128 MByte (flash) data buffer at block transfer of measurements Connection of additional racks to the Test Controller up to 3 slimline racks without Test Controller can be connected to a slimline EC system with embedded controller PAC functionality

Connection Diagram Q.raxx slimline EC Analog Inputs Number 16 Accuracy 0.01 % typical 0.02 % in controlled environment¹ 0.05 % in industrial area² Linearity error 0.01 % of the final value typical Repeatability 0.003 % typical (within 24 h) Input resistance >10 MΩ Isolation voltage 100 VDC permanent channel to channel 500 VDC channels to power supply to interface 3 Measurement Voltage Range max. Deviation Resolution ±80 mv ±10 µv 320 nv Long term drift <1 µv/24 h; 10 µv/8000 h Temperature influence on zero on sensitivity <2 µv / 10 K <0.02 % / 10 K Signal-noise-ratio 100 db at 100 Hz 1 according EN 61326: 1997, appendix B 2 according EN 61326: 1997, appendix A 3 noise pulses up to 1000 VDC, permanent up to 250 VDC

Measurement Thermocouple Type Adjusted with internal Cold Junction Compensation Deviation Type B (400 C to 1820 C) < ±1,5 C in the relevant input range Type E, J, K (-100 to 1000 C) < ±0,5 C Type E (-270 C to 1000 C) < ±0,8 C Type K (-270 C to 1372 C) < ±0,8 C Type L (-200 C to 900 C) < ±0,5 C Type N (-100 C to 1000 C) < ±0,5 C Type N (-270 C to 1300 C) < ±0,8 C Type R, S (-50 C to 1768 C) < ±1 C Type T, U (-100 C to 400 C) < ±0,5 C Type B (400 C to 1820 C) < ±0,8 C Type B (400 C to 1820 C) < ±1,5 C The specifications are valid with activated mains rejection 50 Hz resp. 60 Hz Long term drift <0.025 C / 24 h; <0.05 C / 8000 h Temperature influence (Type K) on zero on sensitivity <0.05 C / 10 K <0.02 % / 10 K Uncertainty cold junction compensation <0.3 C Analog/Digital Conversion Resolution Sample rate Conversion method Anti-aliasing filter Digital filter Averaging 24 bit 100 Hz each channel Sigma-Delta low pass 3 rd order per channel (-3 db at 20 Hz) variable digital low pass filter 1 st order sliding 10 x 10 ms for optimization of the precision (always active) in addition optional filter for mains rejection 50 Hz/60 Hz, measuring rate is 10 Hz Digital Inputs (slimline EC only) Function Input voltage Input current Upper switching threshold Lower switching threshold fixed definition max. 30 VDC max. 1.5 ma >3.5 V (high) <1.0 V (low)

Digital Outputs (slimline EC only) Function Type of output Output voltage Output current fixed definition Open Drain p-kanal MOSFET max. 30 VDC max. 100 ma Communication Interface (slimline RS) to connect to a Test Controller Standard Data format Protocols RS-485, 2-wire 8e1 Local-Bus: 115200 bps up to 48 Mbps Modbus-RTU, ASCII: 19200 bps up to 115200 bps Host Interface Ethernet (slimline EC only) Protocols TCP/IP, UDP, PING, ASCII, Modbus TCP/IP Services DHCP, FTP-Server, FTP-Client, e-mail-send-client (SMTP) Baud rate 10/100 Mbps Data rate max. 800 kbyte/s Number of simultaneous Clients 10 Isolation voltage 500 V Host Interface EtherCAT (slimline EC only) Standard Number of channels Baud rate Ethernet 1024 Byte read and write data, 254 variables 100 Mbps Cycle time 100 µs Isolation voltage 500 V Slave Interfaces RS 485 (slimline EC only) to connect further slimline RS, see Connection Diagram Number of interfaces 3 Standard RS 485 Data format Protocol Baud rate Isolation voltage 8E1 Local Bus 9.6 kbps up to 24 Mbps 500 V Data Memory (slimline EC only) RAM Flash 16 MByte (optional 90 MByte), cycle buffer 128 MByte

Synchronization of a Multi Device System (slimline EC only) Interface Mode RS485 Standard GPS NMEA over RS232 Master Slave principle, IRIG standard SNTP over Ethernet DCF77, AFNOR etc, GPS over IRIG standard Power Supply Power supply Power consumption slimline RS Power consumption slimline EC Influence of the voltage 10 up to 30 VDC, overvoltage and overload protection approx. 8 W approx. 13 W <0.001 %/V Mechanical Type Dimensions (W x H x D) Protection system 19 Standard, 1 unit (444 x 44 x 260) mm IP20 Environmental Operating temperature Storage temperature Relative humidity -20 C up to +60 C -40 C up to +85 C 5 % up to 95 % at 50 C, non condensing PAC Functionality (slimline EC only) Cycle time Processing 1 ms cyclic or synchronized with data acquisition

Programming Tool test.con Using test.con for programming of the PAC-function in a graphical way: Warm Up Time All declarations are valid after a warm up time of 45 minutes. Valid from April 2017. Specification subject to change without notice DB_Q.raxx_A104-16SL_E_23.docx