Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

Similar documents
User Guide. AC/DC Mini Clamp Meter. Model

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

True RMS AC / DC Power Clamp Meter Model

User s Guide. Model MA A AC Mini Clamp-on Meter

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC/DC Clamp Meter Model EX613

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

200Amp AC Clamp Meter + NCV Model MA250

Compact MultiMeters + Voltage Detector

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

USER GUIDE. IR Thermal Scanner. Model IRT500

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User Guide. EasyView Digital Light Meter. Model EA31

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

ET-3888 True RMS Clamp Meter. User Manual

2000 A DCA/ACA CLAMP + DMM,

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

AC Clamp Meter + Phase Rotation Tester

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Passive Component LCR Meter

Pen Multimeter. Model

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User Manual 4 wire Earth Resistance Tester Model GRT300

User's Manual. Clamp-on Power Datalogger. Model

DM-46 Instruction Manual

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

312, 316, 318. Clamp Meter. Users Manual

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

USER'S MANUAL DMR-6700

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Autoranging Multimeter Extech EX503

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

Digital Clamp Meter. User Manual

BENNING. CM7 Electrical Tester. Service Information

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

NOTE: Fully read and understand this manual before using this Digital Multimeter.

AC/DC CLAMP METER USER S MANUAL

EasyView Light Meter with Memory

OPERATOR S INSTRUCTION MANUAL

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

DM-46 Instruction Manual

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MODEL: D03128 CLAMP METER

User's Manual. Model f/1f Power Clamp-on Meter

Digital Clamp Meter Model: &

Pen Multimeter. Model

USER'S MANUAL DMR-4350

Mini Clamp Meter Model:

Not for Reproduction

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Micro-Ohmmeter Model UM200

Non-contact Forehead IR Thermometer

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AM

Multifunction Digital

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

OPERATOR S INSTRUCTION MANUAL

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

USER'S MANUAL DMR-4300

MS2030 CAT III 600 V A V AUTO RS232

USER'S MANUAL DMR-2400

User Manual. All rights reserved. Specifications are subject to change without notice.

Model: &

ATK Clamp Meter

Pen-type DIGITAL MULTITESTER

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

CONTENTS MS2033A. 1.Introduction Safety Information...01

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

Transcription:

Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter User Guide

Introduction Congratulations on your purchase of the Extech Model 380942 DC/AC Clamp Meter. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Meter Description 1. Current sense jaw 2. Measurement Trigger 3. Function switch 4. Data HOLD key 5. MAX / MIN key 6. One-touch DCA ZERO key 7. LCD Display 8. Positive input terminal for Voltage 9. COM terminal 1 2 3 4 56 7 8 9 Safety Symbols and Information! Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) This meter has been designed to be safe in use, but the operator must use caution in its operation. The rules listed below should be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: 2. USE EXTREME CAUTION when working with high voltages. 3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground. 4. ALWAYS turn off the power and disconnect the test leads before opening the back to replace the fuse or batteries. 5. NEVER operate the meter unless the back cover and the battery/fuse door are in place and fastened securely. 2

Operation AC Current Measurements (True RMS) WARNING: To avoid electric shock, disconnect the test leads from the meter before making current measurements. 1) Set the Function switch to the 400mA, 4000mA, or 30A AC range. 2) Press the jaw trigger and clamp around, fully enclosing a single conductor. Do not allow a gap between the two halves of the jaw. Refer to the diagram at right for the correct way to enclose a single conductor. 3) Read the AC Current value on the LCD s digital or bargraph display. Yes DC Current Measurements WARNING: To avoid electric shock, disconnect the test leads from the meter before making current measurements. 1) Set the Function switch to the ma or 30A DC range. 2) Press the DCA zero key to null the meter display. 3) Press the Trigger to open the current sense Jaw. 4) Fully enclose the conductor to be measured. Do not allow a gap between the two halves of the jaw. 5) Read the DC Current value on the LCD s digital or bargraph display. AC Voltage Measurements (True RMS) WARNING: To avoid electric shock or damage to the meter, do not make any voltage measurements that exceed the maximum specified limits. 1) Set the Function switch to the 400V AC position. 2) Insert the test leads to the meter as follows: Red lead to V terminal; Black lead to the COM input. 3) Connect the test leads to the circuit or device under test. 4) Read the AC Voltage value on the LCD s digital or bargraph display. DC Voltage Measurements WARNING: To avoid electric shock or damage to the meter, do not make any voltage measurements that exceed the maximum specified limits. 1) Set the Function switch to the 400V DC position. 2) Insert the test leads to the meter as follows: Red lead to V terminal; Black lead to the COM input. 3) Connect the test leads to the circuit or device under test. 4) Read the DC Voltage value on the LCD s digital or bargraph display. No 3

Advanced Features Relative Measurements 1) Press the ZERO key. The displayed reading will zero and the word ZERO will appear on the upper portion of the LCD. 2) All subsequent measurements will now be displayed with respect to the zeroed reading. For example, if a 20A reading is zeroed and a 30A reading is subsequently measured, the LCD will display 10A. 3) To return to normal operation, press and hold the ZERO key for 2 seconds until the word ZERO switches off. 4) Note that Relative mode is not available if MIN/MAX mode is enabled. Data Hold To freeze the current reading on the LCD, press the Data Hold key. The word HOLD will appear on the LCD while the meter is in the Data Hold mode. To release the Data Hold function and return the meter to normal operation, press the Data Hold key again. The word HOLD will switch off. MIN/MAX Readings Pressing the MIN/MAX key allows the meter to display the highest and then the lowest readings encountered. Press the MIN/MAX key once to view the minimum reading, press it again to view the maximum reading. Note that the meter will only change its displayed reading when a measurement is taken higher than the previous MAX or lower than the previous MIN readings. The HOLD display icon (along with the MIN or MAX icon) will appear on the LCD in MIN/MAX mode. Pressing the MIN/MAX key a 3 rd time returns the meter to normal operation. Auto Power Off To extend battery life, the meter will auto power off after 30 minutes of operation. To resume operation, either turn the meter OFF and then ON again, or press the HOLD button. To disable the auto power off function, press down the HOLD key while turning the meter on. 4

Maintenance Battery Replacement 1) When the low battery symbol appears on the LCD the batteries must be replaced. 2) Turn the meter OFF and remove the rear battery compartment Phillips screw. 3) Lift off the battery compartment cover and replace the two 1.5V AA batteries. 4) Replace the compartment cover and secure the screw. 5) You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Cleaning Caution: Use only a dry cloth to clean the plastic case. 5

Specifications General Specifications Display 3-3/4 digit (4000 count) LCD with 40 segment bargraph Functions ACA, DCA, ACV, DCV Polarity Minus sign ( - ) indicates negative polarity Current sensor Hall effect sensor type Overload indication Left blinking digit DCA zero adjust One touch zero key Display rate 2 readings/second (20 readings/second for bargraph) Battery Two 1.5V AA batteries Operating conditions -10 o C to 50 o C (4 o F to 122 o F); < 85% Relative Humidity Storage conditions -20 o C to 60 o C (- 4 o F to 140 o F); < 75% Relative Humidity Altitude Operate at less than 2000 meters (for indoor use only) Power consumption Approximately 10mA DC Weight 190g (6.2 oz.) including battery Dimensions 183 x 63.6 x 35.6mm (7.2 x 2.5 x 1.4 ) (H x W x D) Jaw opening 23mm (0.9 ) Standards IEC 1010 Category III 300V, Category II 600V Range Specifications Function Range Resolution Accuracy Overload protect DC Current 4000mA 1mA ± (2.0% + 3d) 40A DC AC Current (True RMS) 30A 10mA 100A DC 50/60Hz 40 to 100Hz 400mA 0.1mA ±(1.5% + 5d) ±(2.0% + 5d) 40A AC 50/60Hz 40 to 1kHz 4000mA 1mA ±(2.5% + 5d) ±(3.0% + 5d) 40A AC 30A 10mA ±(2.0% + 5d) ±(2.5% + 5d) 100A AC DC Voltage 400V 0.1V ± (1.0% + 2d) 1000V DC AC Voltage (True RMS) 50/60Hz 40 to 1kHz 400V 0.1V ±(1.5% + 4d) ±(2.0% + 5d) 800V AC Specification Notes AC Voltage and Current Crest Factor: < 3 AC / DC Voltage Input Impedance: 10M Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com 6