Volume Control Valve Trim

Similar documents
3-way Transfer Valve Trim

Thermostatic Valve Trim

Volume Control Valve Trim

Wall-Mounted Basin Set

Bodyspray INSTALLATION INSTRUCTIONS

Vir Stil Console Lavatory INSTALLATION INSTRUCTIONS

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

Tuxedo Console Table INSTALLATION INSTRUCTIONS P73037, P73038, P _2_B Page 1 of 5

MALEKO WALL-MOUNT FAUCET INSTALLATION

WILLIS WALL-MOUNT FAUCET INSTALLATION

BALANTINE WALL-MOUNT FAUCET INSTALLATION

Cast Iron Undercounter Kitchen Sink

Single Basin Stainless Steel Sink

CALLAS THERMOSTATIC SHOWER SET

EXIRA SHOWER SET INSTALLATION

WILLIS WIDESPREAD FAUCET

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

VICTORIAN WIDESPREAD FAUCET

INSTALLATION GUIDELINES

LATTIMORE SHOWER SET INSTALLATION

INSTALLATION INSTRUCTIONS

Vanity INSTALLATION INSTRUCTIONS P74205, P74209, P74202-SM P74201, P74200, P P74203, P74207, P74202-LG _2_E 1 of 6

Installation Instructions

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS

Office Partitions WARNING. Assembly Instructions. Customer Service A S S E M B LY HARDWARE H1 H2 H3 H4 H5 H8 H9 H10 H11 H12

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

H2-50 Hydrogen Generator Field Update

ONASSIS SHOWER SET INSTALLATION

Congratulations! You are now on your way to enriching your life with!

Installation Instructions

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Installation and Maintenance Instructions

HDL(M)6 Nut/Screw Assembly

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950)

FM125 & FM126 Service Guide

Caution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation

Jenny Legs Assembly Instructions

MODEL SK61732 COMPRESSOR SERVICE KIT

ASSEMBLY INSTRUCTIONS YS480 PELLET COOKER - 24 YS640 PELLET COOKER - 32

GP-SD GENIE PROBE SMALL DIAMETER

Models: PLAV70-UNL, PLAV70-UNLP. Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 95" Plasma Screens

EZ-HAUL GARDEN CRATE WAGON

Door Hardware Installation Instructions. Version A No Interior on an Un-prepped Door Step 1 Select the Position of the Handleset

REVIVAL ACCESSORIES BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS B. PRODUCT NOTES C. ORDERING INFORMATION D. REQUIRED TOOLS AND MATERIALS

45 CUTTING HEAD TILE SAW-BLADE ALIGNMENT PROCEDURE

Maintenance Information

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

Replacing the Reciprocator on an SWF Multi-head.

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

RG REPAIR GUIDELINE 10/23/2015. Repair Description: Tools Required: Step List: Approximate time: minutes

INSTALLATION INSTRUCTIONS GRILLE GUARD CHEVY TAHOE / AVALANCHE 1500/ SUBURBAN 1500 PART # /502795

Fan, Eden/Northfield, GS Installation Instructions (SKU ) Packing List

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

Traditional Wall Mounted Potfiller

INSTALLATION INSTRUCTIONS

(2) 25mm x 20mm x 5mm Adhesive Backed Foam Pads. 100mm x 50mm x 1.0mm Adhesive Backed Foam. (2) Spacer Plates. Passenger/Right Side Frame Mounting

Riverside. Oakmont Queen Storage Bed Assembly Instructions

RC4WD R2 Disconnect Transmission parts replacement guide

Orbital Test Stand. Operations and Assembly Manual. Department of Mechanical Engineering Northern Arizona University Flagstaff, AZ 86011

WEIGHT ADJUSTABLE ESPREE. Model 2ESP-WA-C48- Model 2ESP-WA-C60- 2ESP-WA Rev B 8/17 ASSEMBLY AND OPERATION

Privacy Wall Glass Selections - Polished Edge Slider Door

Special Z-Axis Ballscrew Replacement

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

AUGMENT THE WEIGHT STACK SELECTION PRO SELECTION PRO MED INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS SIDE BAR FORD ESCAPE & MAZDA TRIBUTE PART #

Installation and Assembly: Ceiling mount for LCD screens up to 29"

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87

XHD Bull Bar w/ Dual Row LED Light Bar (10-17 Jeep JK)

INSTALLATION INSTRUCTIONS

TorqueMaster Replacement Spring

Frameless Inline Door With Return QCI5128

SECTION 7 - SUSPENSION

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

INSTALLATION INSTRUCTIONS FOR WALL TUB SETS, TWO HANDLE SHOWER SETS AND WALL LAVATORY SET VALVES NUMBERED: RC & RC

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6C /5

O-Sullivan King 4 Poster Bed O-Sullivan Queen 4 Poster Bed Parts and Hardware List

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6D /7. Tyger Guard. Tube Brackets (Bull Bar) passenger or driver side

PACIFIC LASER SYSTEMS. HVL100 Procedures

SHELTON THERMOSTATIC SHOWER PANEL

To remove sanding pad, turn counterclockwise.

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

HOW TO TUNE A QB SERIES CO2 AIRGUN FOR NOOBS.

FAIRFAX ROUGHING-IN K-12151T=673. UNIT: mm K-12153T K-12156T K-12151T=610 K-12157T K-12161T T01-A -1- INSTALLATION INSTRUCTIONS

CW-1401 (WL1212) CB-1401 (BL1212)

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

Series B Medical Gas Service Outlet Upgrade Kits

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Transcription:

Volume Control Valve Trim P23013-CR, P23013-LV, P23123-LV, P23223-RK, P23223-LV, P24113-CR, P24113-LV, P24118-CR, P24118-LV, P24423-CR, P24423-LV, P24523-TT, P24623-CR, P24623-LV, P24723-LV 2014 1 of 6 KALLISTA

THANK YOU FOR CHOOSING KALLISTA Volume Control Valve Trim We appreciate your commitment to KALLISTA quality products. Please take a moment to review this manual before you install your KALLISTA product. If you encounter any installation or performance problems, please do not hesitate to contact us at the phone number listed at the bottom of the page. BEFORE YOU BEGIN Please read all instructions before you begin. Prior to installation, unpack the valve trim and inspect it for damage. Return it to the carton until installation. Observe all local plumbing and building codes. Shut off the water supply. The appearance of your product may differ from what is shown in these instructions, however, the installation procedure is the same. KALLISTA reserves the right to make revisions in the design of products without notice, as specifi ed in the Price Book. TOOLS AND MATERIALS Assorted Hex Wrenches Assorted Screwdrivers 2 of 6

1. INSTALL THE VALVE STEM ADAPTER Select the correct valve stem adapter and screw. Spline Adapter Valve Stem Adapter NOTE: Check the fi nished wall surface as related to the graphics on the plaster guard. Select the correct length valve stem adapter and screw for your application. Refer to the information stamped on the plaster guard to verify the wall thickness. Thin wall - 3/16 (5 mm) to 9/16 (14 mm): Use the 7/8 (22 mm) (short) valve stem adapter, stamped 3 on the plaster guard, and the 3/8 (19 mm) screw. Standard wall - 9/16 (14 mm) to 1-1/16 (27 mm): Use the 1-3/8 (35 mm) (medium) valve stem adapter, stamped 1 on the plaster guard, and the 1-3/8 (35 mm) screw. Thick wall - 1-1/16 (27 mm) to 1-9/16 (40 mm): Use the 1-7/8 (48 mm) (long) valve stem adapter, stamped 2 on the plaster guard, and the 1-3/4 (44 mm) screw. Remove and discard the plaster guard from the valve. Place the spline adapter over the valve stem. Set the valve stem adapter over the spline adapter. Do not completely press or screw the valve stem adapter into place until instructed to do so. 3 of 6

2. ADJUST THE HANDLE ASSEMBLY Spline Adapter Valve Stem Adapter Handle Assembly Ensure the valve stem adapter is lightly placed over the spline adapter. Place the handle assembly over the valve stem adapter. Turn the handle counterclockwise until the valve is fully closed. The handle should be in the vertical, 6 o clock position. Remove the handle assembly and set aside. Handle Alignment Adjustments NOTE: The spline adapter allows fi ne adjustment of the handle alignment. Remove the handle assembly and the valve stem adapter. Reposition the spline adapter. Reinstall the handle assembly and the valve stem adapter. Check the alignment. Repeat until the handle alignment is satisfactory. 4 of 6

3. INSTALL THE FRONT PLATE Verify the seal covers the wall opening. Screw Screw Valve Stem Adapter Ensure the valve stem adapter is fi rmly pressed onto the valve stem. Secure the valve stem adapter to the valve with the correct length screw, as selected in the Install the Valve Stem Adapter section of this guide. Align the holes on the front plate assembly and the valve. NOTE: Be sure to select the correct length screw for your application. Attach the two screws through the front plate assembly and into the valve. Do not overtighten. Visually inspect the front plate assembly to ensure the foam seal is completely covering the wall opening. If not, stop the installation and repair the wall opening. 5 of 6

4. INSTALL THE TRIM All other Trim P24723-LV Trim Escutcheon Adapter Ring Escutcheon Front of Adapter Ring Setscrew NOTE: If installing the P24723-LV trim, proceed to the For P24723-LV section below. Place the escutcheon on the wall with the drain notch located downward in the 6 o clock position. Thread the handle assembly onto the hub of the front plate assembly to secure the escutcheon in place. A lever handle should point downward in the 6 o clock position. NOTE: If the handle does not engage the valve or the escutcheon does not tighten to the wall, replace the valve stem adapter with an adapter of appropriate length. For P24723-LV Thread the adapter ring onto the hub of the front plate assembly. Place the escutcheon on the wall with the drain notch located downward in the 6 o clock position. Place the handle assembly against the escutcheon by lining up the pins in the handle assembly with the holes in the escutcheon. Make sure the handle is pointing down to the 6 o clock position and the setscrew hole is facing down. Verify the setscrew will contact the front angle of the adapter ring. Thread the adapter ring in or out until appropriate setscrew contact is achieved. Tighten the setscrew with a hex wrench. Make sure the handle assembly is tight against the escutcheon. 6 of 6