Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray.

Carton of 1, B. Min. 2-,34mm 2 Max. 3-1,5mm V 22 to 14 AWG Min. 2 #22 Max. 3 #16. ,34mm 2 to 2,5mm 2. Min.

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN12STGN500 THHN 12 STR Green 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

SIMpull THHN, it slips and slides - all with NoLube.

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN2BK2500 THHN 2 STR Black 2500

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

SUBMITTAL COVER SHEET

Threaded entry. to 1,5mm Carton of 1, Min. 2 #22 Max. 2 #16 Min. 2-,34mm 2 2. Min. 2 #22 Max. 3 #16 Min. 2-,34mm 2 Max.

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

CIR (Crush & Impact Resistant) VFD Power Cable

SECTION BUILDING WIRE AND CABLE

Submittal Review SW Macadam Ave Suite 200 ATTENTION: Riley Tobin. Portland, OR RE: BSD Sunset High School

Section A pg /28/08 11:07 AM Page 1 A ermination Wire T

Instrumentation Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

A. Product Description: Stranded conductor insulated wire.

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

SECTION ELECTRICAL IDENTIFICATION

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

Detailed Specifications & Technical Data

A. Product Data: For each electrical identification product indicated.

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

TE Connectivity Wire Connectors

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

14 AWG 2 AWG: 600 Volt

The Brand Electricians Trust. Full-Line Catalog. Wire Termination Tools & Supplies Precision Wire Processing Test & Measurement DataComm

MEDIUM VOLTAGE

BX /2 Solid Ac/BX Aluminum Cable

SECTION MEDIUM-VOLTAGE CABLES

onlinecomponents.com

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Airport Cables & Connectors

Low Voltage Splices, 1000 V or less

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Shielded Fire Alarm Cables

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

SECTION TRANSFORMERS

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

DLO Flexible Power Cable

Electrical Wiring: Commercial, Seventh Canadian Edition

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

IMSA TRAFFIC SIGNAL CABLE

GEXOL WORLD CLASS OIL & GAS CABLES

SECTION COMMUNICATIONS COPPER OSP CABLING

LGH High Voltage Connectors

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Wisconsin Contractors Institute Continuing Education

QSLVM2500 QSLV-M Cold Shrink Insulator

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

Heat-Shrinkable Tubing

Thru Wall Floor Seals For New Installation

3M Scotchlok Insulated Electrical Spring Connector B (Blue)

Detailed Specifications & Technical Data

General Information...SA1-SA4

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

CONTINUING EDUC ATION

American Electrical Institute

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

Low Voltage Splices 0-600V (1000V rated) Cold Shrink Splices (0-1000V)

AEE. Canada. Australia

B. Manufacturers: Square-D, G.E. or Westinghosue.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Article 250 Grounding & Bonding

Color-Keyed. Compression Connector System. Table of Contents

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Regal Series Recessed Flatwalls

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Electrical submittal no data received July 2, 2015 has been reviewed by this office with the following disposition:

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

ELPT 1429 RESIDENTIAL WIRING

INTERMEDIATE METAL CONDUIT

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Ground Clamps Cable Tray

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

TIGER BRAND MINING CABLES

SECTION EQUIPMENT WIRING

Transcription:

SUBMITTAL REVIEW July 6, 2015 Melissa Guarin Beaverton School District 16550 SW Merlo Road Beaverton, OR 97003 Project: BSD Sunset High School Athletic Center Project No.: 14-1791.00 Dear Melissa: Electrical submittal no. 5-262000-0 data received July 1, 2015 has been reviewed by this office with the following disposition: Item Manufacturer Action 260519 Low Voltage Electrical Power Conductors and Cables Conductor 600-Volt Cerrowire No Exceptions Taken Connectors Ideal No Exceptions Taken Branch Circuit Conductor Splices Polaris No Exceptions Taken Splices with Compression Fitting/ Polaris No Exceptions Taken Heat-Shrinkable Fittings Cable Test Data Honeywell No Exceptions Taken The above submittal data has been reviewed only for conformance with the design concept and for compliance with information given in the Contract Documents, and this review does not extend to means, methods, techniques, sequence of construction, dimensions, quantities, or safety precautions thereto. Review does not relieve the contractor from responsibility for variations from the requirements of the Contract Documents. Returned herewith is one (1) copy of the above data. We are retaining one copy for our files. Please include a copy of this letter with each submittal package. Sincerely, Todd Thayer TDT/mmb P:\2014\14-1791.00 - BSD Sunset HS Athletic Center\04 Construction Administration\Submittals\5-262000-0\5-262000-0_PAE Submittal Letter.docx

SUBMITTAL REVIEW PROJECT NAME Sunset HS Title IX Compliance Interiors and Concessions PROJECT # 7928 SUBMITTAL NAME Low Voltage Electrical Power Conductor and Cable SUBMITTAL NUMBER 05 26 20 00 DATE 07/07/15 REVIEWERS Jessica Faust Project Manager Chris Sandberg Inspector (Previous electrical lead) COMMENTS: Submittal approved as submitted. Stranded wire is to be used for all wiring. District Goal: All students will show continuous progress toward their personal learning goals, developed in collaboration with teachers and parents, and will be prepared for post-secondary education and career success. The Beaverton School District recognizes the diversity and worth of all individuals and groups. It is the policy of the Beaverton School District that there will be no discrimination or harassment of individuals or groups based on race, color, religion, gender, sexual orientation, gender identity, gender expression, national origin, marital status, age, veterans' status, genetic information or disability in any educational programs, activities or employment.

Sunset High School 13840 NW Cornell Rd. Portland, OR 97229 To: BLRB ARCHITECTS, P.S. Date: 07/01/2015 Attn: RICHARD HIGGINS 1001 SW 5TH AVE., SUITE 1100 Contact Phone: 503-535-0707 PORTLAND, OR 97204 Contact Email: RHIGGINS@BLRB.COM CC d: SUBMITTAL TRANSMITTAL FOR APPROVAL Submittal #: 65 Rev.#: 0 In Accordance with Specification Section #: 260519 This is a submittal for Low Voltage Electrical Power Conductors and Cables items per the table below as reviewed and noted by Pavilion Construction NW, LLC, and provided by. Please provide a response to this submittal by 07/11/2015. Pavilion Status: Sent/Submitted Notes: Submitted By: Riley Tobin Phone: (503)290-5005 Email Address: rtobin@pavilionconstruction.com Fax: (503)244-1810 Architect s Response SUBMITTAL RESPONSE Schedule Tracking Proceed Date Received from Sub/Sup 06/30/2015 Proceed, as noted Date Requested to be returned 07/11/2015 Revise and Resubmit Date Returned from Architect Material Return without Review Date Returned to Sup/Sup Comments: PAVILION CONSTR JCTION LLC o APPROVED AS SUBMITTEO o OISAPPROVEO, PlIASE SUBMIT COPlES o APPRDVEOAS NOTEO o F()R THE RECORD RY: _ Riley _ Tobin DATED: 7/1/15 06/23/15 This submittal has been reviewed for general "onformil."'.ce with ttle contract documents. Tn's review does not reuevs the supplier of responsibility for erro~, omissions or any dtviition tram the requirem ents of the ",..... r?c! :!vr:umems. Pavilion Construction NW, LLC 4700 SW Macadam Ave. Portland, OR 97239 Phone: (503)290-5005 Fax: (503)244-1810 www.pavilionconstruction.com Page 1 of 1

Sunset High School - Title IX and Upgrades Beaverton School Dstrict No. 48 BLRB Project No.: 14.84P Permit Set May 15, 2015 SECTION 26 05 19 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. B. The provisions of Division 26 Section, Common Work Results for Electrical apply to this section. 1.2 SUMMARY A. This Section includes: 1. Copper conductors. Indicated sizes shall be considered minimum for ampacities and voltage drop requirements. 2. Conductors for special systems shall be as recommended by the equipment manufacturer except as noted. 3. Deliver conductors to the job site in cartons, protective covers, or on reels. B. Related Sections include: 1. Section 26 05 26 Grounding and Bonding for Electrical Systems. 2. Section 26 05 33 Raceways and Boxes for Electrical Systems. 3. Section 26 05 53 Identification for Electrical Systems. 1.3 REFERENCED STANDARDS A. ASTM: American Society For Testing and Materials: 1. ASTM B 3 Soft or Annealed Copper Wire. 2. ASTM B 8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft. 3. ASTM B 33 Tinned Soft or Annealed Copper Wire for Electrical Purposes. B. ICEA: Insulated Cable Engineers Association: 1. S-95-658 Non-shielded 0-2 kv Cables C. IEEE: Institute of Electrical and Electronic Engineers: 1. IEEE 383 Type Test of Class IE Electric Cables, Field Splices, and Connections. D. UL: Underwriters Laboratories: 1. UL 44 Rubber-Insulated Wires and Cables. 2. UL 83 Thermoplastic-Insulated Wires and Cables. 3. UL 1277 Type TC Power and Control Tray Cable. 1.4 SUBMITTALS A. Submit product data for the following materials: 1. Single conductor 600-volt power and control conductors. See Pages 8-9 BLRB Architects - Portland, Oregon PAE LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 26 05 19-1

Sunset High School - Title IX and Upgrades Beaverton School Dstrict No. 48 BLRB Project No.: 14.84P Permit Set May 15, 2015 B. Submittals of the following materials shall consist only of a listing of the manufacturer s name and the applicable catalog numbers of the items to be utilized. 1. Connectors. See Pages 11-12 2. Branch circuit conductor splices. See Pages 11-12 3. Splices with compression fitting and heat-shrinkable insulator. See Pages 14-15 C. Submit cable test data per testing requirements of Part 3. Pages 17-18 PART 2 - PRODUCTS 2.1 CONDUCTORS 600V A. Type: 1. Copper: No. 12 AWG minimum size unless noted otherwise. No. 12 and No. 10, solid or stranded, No. 8 or larger, Class B concentric or compressed stranded. 2. Aluminum is not permitted and shall not be utilized. B. Insulation: 1. THHN/THWN-2 for conductors 6 AWG and smaller. 2. XHHW-2 for conductors 4 AWG and larger. C. Thru wiring in fluorescent luminaires shall be rated for 90 degree C minimum. D. Manufacturers: General, Essex, Southwire, or equivalent. 2.2 POWER LIMITED WIRING A. Copper, stranded or solid as recommended by the system manufacturer. B. Insulation shall be appropriate for the system and location used. 2.3 CONNECTORS 600V AND BELOW A. Branch Circuit Conductor Splices: 1. Live spring type, Scotchlok, Ideal Wire Nut, Buchanan B-Cap, or 3M Series 560 self-stripping type. B. Cable Splices: Compression tool applied sleeves, Kearney, Burndy, or equivalent with 600V heat shrink insulation. Except where specifically indicated on the plans, all proposed splice locations shall be submitted for review by the Engineer. C. Terminator Lugs for Stranded Wire: 1. 10 AWG Wire and Smaller: Spade flared, tool applied. 2. 8 AWG Wire and Larger: Compression tool applied, Burndy, Anderson, or equivalent. 3. Setscrew type terminator lugs furnished as an integral part of switches and circuit breakers will be acceptable. BLRB Architects - Portland, Oregon PAE LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 26 05 19-2

Sunset High School - Title IX and Upgrades Beaverton School Dstrict No. 48 BLRB Project No.: 14.84P Permit Set May 15, 2015 PART 3 - EXECUTION 3.1 CONDUCTORS A. Pulling compounds may be used for pulling all conductors. Clean residue from the conductors and raceway entrances after the pull is made. B. Pulleys or blocks shall be used for alignment of the conductors when pulling. Pulling shall be in accordance with manufacturer s specifications regarding pulling tensions, bending radii of the cable, and compounds. C. Make up and insulate wiring promptly after installation of conductors. Wire shall not be pulled in until all bushings are installed and raceways terminations are completed. Wire shall not be pulled into conduit embedded in concrete until after the concrete is poured and forms are stripped. D. Provide a dedicated neutral conductor with each branch circuit, do not use a shared neutral conductor between phases unless specifically requested or directed. 3.2 CONNECTORS A. Control and special systems wires shall be terminated with a tool applied spade flared lug when terminating at a screw connection. B. All screw and bolt type connectors shall be made up tight and retightened after an eight hour period. C. All tool applied compression connectors shall be applied per manufacturer s recommendations and physically checked for tightness. 3.3 COLOR CODING A. Secondary service, feeders, and branch circuit conductors shall be color coded. Phase color code to be consistent at all feeder terminations, A-B-C left-to-right, A-B-C top-to-bottom, or A-B-C front-toback. Color code shall be as follows: 120/240 volt 208Y/120 volt Phase 480 volt 480Y/277 volt Black A Brown Red B Orange Blue C Yellow White Neutral Gray* Green Ground** Green * or white with colored (other than green) tracer **Ground for isolated ground receptacles shall be green with yellow tracer. B. Use solid color compound or solid color coating for No. 12 and No. 10 branch circuit conductors and neutral sizes. C. Phase conductors No. 8 and larger color code using one of the following: 1. Solid color compound or solid color coating. 2. Stripes, bands, or hash marks of color specified above. BLRB Architects - Portland, Oregon PAE LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 26 05 19-3

Sunset High School - Title IX and Upgrades Beaverton School Dstrict No. 48 BLRB Project No.: 14.84P Permit Set May 15, 2015 3. Colored as specified using 3/4-inch wide tape. Apply tape in half overlapping turns for a minimum of three inches for terminal points and in junction boxes, pull boxes, troughs, manholes, and handholes. Apply the last two laps of tape with no tension to prevent possible unwinding. Where cable markings are covered by tape, apply tags to cable stating size and insulation type. D. Switchlegs, travelers, etc., to be consistent with the phases to which connected or a color distinctive from that listed. E. Color-coding of the flexible wiring system conductors and connectors shall be the manufacturer s standard. F. For modifications and additions to existing wiring systems, color-coding shall conform to the existing wiring system. 3.4 FIELD TESTING A. All 600-volt rated conductors shall be tested by the Contractor for continuity. Conductors 100A and over in size shall be meggered after installation and prior to termination. Provide the megger, rated 1,000 volts d.c., and record and maintain the results, in tabular form, clearly identifying each conductor being tested. 1. Replace cables when test value is less than 15 megohms. 2. Cable test submittal shall include results, equipment used, and date. END OF SECTION 26 05 19 BLRB Architects - Portland, Oregon PAE LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 26 05 19-4

26 05 19 Power Conductors and Cables

Wire

THHN/THWN Vinylon PVC/Nylon 14 AWG 10 AWG 90 C Dry 75 C Wet/600 Volts Gasoline and Oil Resistant II Machine Tool Wire (Stranded): 90 C Dry Appliance Wire: 105 C Dry 14 AWG 10 AWG rated THHN/THWN: 90 C Dry, 75 Wet Product Code Conductors AWG Size No. of Strands Covering PVC Ins. Mils. Nylon Jkt. Mils. Approx O.D. Inches Allowable Ampacities* 60 C ** 75 C *** 90 C **** Approx Net Wt. lbs./m ft. APPLICATIONS 600 volt building wire for use in commercial and industrial applications as specified in the NEC Marked VW-1 CONDUCTORS Solid conductors: Uncoated copper per ASTM-B3 Stranded conductors: Uncoated copper per ASTM- B3, ASTM-B787 INSULATION Color coded, heat and moisture resistant PVC (polyvinyl chloride) JACKET Nylon (polyamide), clear INDUSTRY STANDARDS UL 83: File No. E15119 UL 1063 (MTW): File No. E85964 AWM: File No. E11829 Canadian Standard C22.2 No. 75 and CSA Bulletin No. 1451 ASTM: B3, B8, B787 WC70/ICEA S-95-658 Federal Specification A-A- 59544 NFPA70: National Electrical Code SURFACE PRINT Sample: CERRO WIRE VINYLON-A 14 AWG (2.08 mm 2) (UL) THHN or THWN OR MTW OR AWM GR2 VW-1 600V - C (UL) TWN75 OR T90 NYLON 112-14XX 14 SOL 15 4 0.104 15 15 15 15 112-16XX 12 SOL 15 4 0.120 20 20 20 23 112-18XX 10 SOL 20 4 0.151 30 30 30 37 112-34XX 14 19 15 4 0.110 15 15 15 16 112-36XX 12 19 15 4 0.130 20 20 20 24 112-38XX 10 19 20 4 0.165 30 30 30 39 XX Color Add Code (see chart) * Per Table 310-16 NEC ** For termination to equipment for circuits rated 100 amperes or less, or marked for size 14 through 1 AWG conductors. Also for MTW used in wet locations or exposed to oil or coolant. *** For termination to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. Also for THWN-2 exposed to oil or coolant and MTW in dry locations. **** For THHN used in dry locations and THWN-2 used in wet or dry locations. For ampacity derating purposes. AWG Size Black 01 Color Available (Product Code 6th and 7th Digits) White 02 Red 03 Blue 04 Green 05 Orange 06 Yellow 07 Brown 08 Purple 09 Grey 10 14 solid X X X X X X X X X X X 12 solid X X X X X X X X X X X 10 solid X X X X X X X X X X X 14 strand X X X X X X X X X X X 12 strand X X X X X X X X X X X 10 strand X X X X X X X X X X X Package Code J J J K M P 10 13 15 18 Size 14,12 Solid & Strand 10 Solid & Strand 500' spool 1000' ctn X 500' spool 2000' ctn X 500' reel 1000' reel 2500' reel X X 5000' reel 10000' reel 13000' reel 15000' reel Pink 11 18000' reel Cerro Wire LLC 1099 Thompson Road, SE Hartselle, AL 35640 Phone 800.523.3869 І Fax 877.877.9563 www.cerrowire.com Made in USA Rev 09-10-10

90 C Dry or Wet/600 Volts Gasoline and Oil Resistant II Machine Tool Wire: 90 C Dry Appliance Wire: 105 C Dry Rated THHN/THWN-2: 90 C Dry or Wet No pulling lube required Sequential footage markings 1 AWG and larger Max Print for easy ID THHN/THWN-2 Vinylon PVC/Nylon 8 AWG 750 MCM APPLICATIONS 600 volt building wire for use in commercial and industrial applications as specified in the NEC 8-1 AWG is marked VW-1 1/0 750 MCM rated for CT use 8 AWG 750 MCM in black; Rated sunlight resistant Pulling lube is not required. Jacketed with SLP (Self- Lubricating Polymer). CONDUCTORS Uncoated copper per ASTM- B3, ASTM-B787 (6 AWG-500 MCM) & ASTM-B8 (600 MCM- 750 MCM) INSULATION Color coded, heat and moisture resistant PVC (polyvinyl chloride) SLP-JACKET Using Cerro Wire s SLP- Jacket (Self-Lubricating Polymer) Technology, Cerro Wire SLiPWire THHN is self lubricated. Nylon (polyamide), color coded INDUSTRY STANDARDS UL 83: File No. E15119 UL 1063 (MTW): File No. E85964 AWM: File No. E11829 Canadian Standard C22.2 No. 75 and CSA Bulletin No. 1451 ASTM: B3, B8, B787 WC70/ICEA S-95-658 Federal Specification A-A- 59544 NFPA70: National Electrical Code SURFACE PRINT Sample: CERRO WIRE VINYLON -A 350 KCMIL (UL) MTW OR THWN-2 OR THHN OR GASO- LINE AND OIL RESISTANT II OR AWM FOR CT USE SUNLIGHT RESISTANT 600V C(UL) TWN75 OR T90 NYLON Product Code Conductors AWG Size No. of Strands Covering PVC Ins. Mils. Nylon Jkt. Mils. Approx O.D. Inches Allowable Ampacities* 60 C ** 75 C *** 90 C **** Approx Net Wt. lbs./m ft. 112-40XX 8 19 30 5 0.217 40 50 55 63 112-42XX 6 19 30 5 0.253 55 65 75 96 112-44XX 4 19 40 6 0.322 70 85 95 153 112-45XX 3 19 40 6 0.350 85 100 110 190 112-46XX 2 19 50 7 0.380 95 115 130 233 112-47XX 1 19 50 7 0.440 110 130 150 299 112-50XX 1/0 19 50 7 0.480 125 150 170 371 112-52XX 2/0 19 50 7 0.524 145 175 195 459 112-54XX 3/0 19 50 7 0.575 165 200 225 571 112-56XX 4/0 19 50 7 0.630 195 230 260 710 112-60XX 250 37 60 8 0.700 215 255 290 848 112-64XX 300 37 60 8 0.750 240 285 320 1006 112-68XX 350 37 60 8 0.802 260 310 350 1166 112-72XX 400 37 60 8 0.847 280 335 380 1324 112-80XX 500 37 60 8 0.930 320 380 430 1640 112-84XX 600 61 70 9 1.030 355 420 475 1988 112-88XX 750 61 70 9 1.136 400 475 535 2459 XX Color Add Code (see chart) * Per Table 310-16 NEC ** For termination to equipment for circuits rated 100 amperes or less, or marked for size 14 through 1 AWG conductors. Also for MTW used in wet locations or exposed to oil or coolant. *** For termination to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. Also for THWN-2 exposed to oil or coolant and MTW in dry locations. **** For THHN used in dry locations and THWN-2 used in wet or dry locations. For ampacity derating purposes. Color availability: 8 AWG & 6 AWG are available in black, white, red, blue, green, orange, yellow, brown, purple and gray. 4 AWG through 600 MCM are available in black, white, red, blue, green, orange, yellow, brown and gray. 750 MCM is available in black and in white, red, blue, green, orange, yellow, brown and gray by special order only. Color add code is as follows: black 01, white 02, red 03, blue 04, green 05, orange 06, yellow 07, brown 08, purple 09 and gray 10. Cerro Wire LLC 1099 Thompson Road, SE Hartselle, AL 35640 Phone 800.523.3869 І Fax 877.877.9563 www.cerrowire.com Made in USA Rev 01-14-11

Connectors

Wire Termination Wing-Nut Wire Connectors Q Three color-coded models cover a full range of wire sizes from 18 to 6 AWG Q Specially designed contoured wings provide a secure grip for extra leverage on maximum wire combinations Wire Connectors Q Live-action spring expands to accept wire shape and size with no pre-twisting required Q Square-wire spring threads directly onto conductors for fast, secure connections Q Deep skirt helps protect against flash-over and turned-back strands for maximum dielectric protection Q Tough, UL 94V-2 flame-retardant shell rated at 105 C (221 F) Q UL Listed to 486C and CSA Certified to C22.2 #188; comply with Federal Specification W-S-610E Model 451 452 454 Color Wire Combination Range Wire Combination Range (mm) Yellow 18 to 10 AWG Min. 2 #18 Max. 3 #12,75mm2 to 6,0mm2 Min. 2-,75mm2 Max. 3-4,0mm2 Red 18 to 8 AWG Min. 2 #18 Max. 4 #10,75mm2 to 10,0mm2 Min. 2-,75mm2 Max. 4-6,0mm2 Blue 14 to 6 AWG Min. 3 #12 Max. 1 #6 & 2 #8 2,5mm2 to 16,0mm2 Min. 3-4,0mm2 Max. 2-16,0mm2 w/1-4,0mm2 Quantity Box of 100 Jar of 225 Jar of 500 Carton of 1,000 Keg of 5,000 (10 bags, 500 ea.) Barrel of 35,000 Box of 100 Jar of 300 Jar of 500 Carton of 1,000 Keg of 5,000 (10 bags, 500 ea.) Barrel of 25,000 Box of 25 Carton of 250 Keg of 1,000 (10 bags, 100 ea.) Barrel of 10,000 Cat. No. 30-451 30-451J 30-651J 30-551 30-651 30-851 30-452 30-452J 30-652J 30-552 30-652 30-852 30-454 30-554 30-654 30-854 Quantity Box of 100 Cat. No. 30-092 *1,000V maximum in fixtures and signs Greenie Grounding Wire Connectors Q Designed for making ground connections and bonding non-metallic sheathed cable Q Contoured wings for maximum leverage Q Live-action, square-wire spring provides superior grounding connections Q Tough, UL 94V-2 flame-retardant shell Q UL Listed to 467 and CSA Certified to C22.2 #188; comply with Federal Specification W-S-610E Wire Combination Wire Combination Model Color Wire Combination Range Wire Combination Range (mm) 92 Green 14 to 10 Min. 2 #14 Max. 4 #12 2,5mm2 to 6,0mm2 Min. 2-2,5mm2 Max. 2-4,0mm2 w/1-2,5mm2 Jar of 150 30-092J Carton of 1,000 30-192 Keg of 5,000 (10 bags, 500 ea.) 30-292 Barrel of 25,000 30-992 Greenie Grounding Connector fully meets the intent of the N.E.C. and specifically aids in compliance with the following: ARTICLE 250: GROUNDING 250-146 Connecting Receptacle Grounding Terminal to Box 250-148 Continuity and Attachment of Equipment Grounding Conductors to Boxes (B) Grounding continuity (D) Nonmetallic boxes 1-800-435-0705 for Customer Service www.idealindustries.com A-3

Twister Wire Connectors Q Exceptional wire-range capacity three models handle wire combinations from as small as 22 AWG to as large as 6 AWG Wire Connectors Q Ribbed cap provides a secure grip and fast fingertip starts Q Swept wings offer extra leverage and less effort for large wire combinations Q Hexagonal shape accommodates standard nutdriver for tool installation Q Live-action, square-wire spring locks onto wire for safe, secure connections Q Deep skirt helps protect against flash-over and turned-back strands for maximum dielectric protection Q Tough, UL 94V-2 flame-retardant shell rated at 105 C (221 F) Q UL Listed to 486C and CSA Certified to C22.2 #188; comply with Federal Specification W-S-610E Model 340 Color Lt. Blue 342 Wire Combination Range (mm) Quantity Cat. No.,34mm2 to 4,0mm2 Min. 2-,34mm2 Max. 3-4,0mm2 Box of 100 30-340 Jar of 500 30-640J Barrel of 35,000 30-840 Box of 100 Jar of 400 Jar of 750 Carton of 1,000 Keg of 5,000 (10 bags, 500 ea.) Barrel of 25,000 30-341 30-441J 30-341J 30-541 30-641 30-841 Box of 50 30-342 Keg of 2,500 (10 bags, 250 ea.) 30-642 Barrel of 15,000 30-842 Quantity Box od 50 Cat. No. 30-144 Jar of 250 30-244J Jar of 500 30-644J Barrel of 20,000 30-944 22 to 10 AWG Min. 2 #22 Max. 3 #12 Tan 22 to 8 AWG Min. 3 #22 Max. 3 #10,34mm2 to 10,0mm2 Min. 3-,34mm2 Max. 3-6,0mm2 Gray 18 to 6 AWG Min. 3 #14 Max. 2 #8 w/2 #12,75mm2 to 10,0mm2 Min. 3-2,5mm2 Max. 2-10,0mm2 w/2-4,0mm2 341 Wire Combination Range *1,000V maximum in fixtures and signs Wire Connectors Q The widest red/yellow wire range in the industry; min. 2 #18 to max. 4 #10 Q SureGrip overmolding provides better grip for improved leverage, more torque and faster connections Q Comfortable swept wings designed to help reduce hand fatigue Q Expanding square-wire spring provides a secure connection every time Q Tough, UL 94V-2 flame-retardant shell rated at 105 C (221 F) Q UL Listed to 486C and CSA Certified to C22.2 #188; comply with Federal Specification W-S-610E Model 344 Color Wire Combination Range Wire Combination Range (mm) Red/Yellow 22 to 8 AWG Min. 2 #18 Max. 4 #10,34mm2 to 10,0mm2 Min. 2-,75mm2 Max. 4,0-6,0mm2 *1,000V maximum in fixtures and signs A-4 www.idealindustries.com 1-800-435-0705 for Customer Service

Splices

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles with wires being connected from the same side of the connector (Figure1) or opposite sides of the connector (Figure 2). For sizes 250 MCM and larger, they are provided with open wire entry ports on both sides of the connector (Figure 3), which allows for access from either side. This style is supplied with removable access plugs to close the entry port not being utilized. Abrasion and chemical resistant. UV rated. Will not support combustion. Cold temperature rated to -45 C. Dual rated for use with copper and/or aluminum cables. 600 volts. 90 C. To receive the material in bags, add -B to the catalog number. Not recommended for fine-stranded, flexible wire. See Polaris Grey Series page 88. CATALOG UPC WIRE (INCHES) HEX CARTON WEIGHT FIGURE NO. CODE RANGE LENGTH HEIGHT WIDTH SIZE QTY. LBS.EA IT-4 95001 1 4-14 1.07 1.50 1.12 slotted 12.06 ITO-4 95002 2 4-14 1.07 1.50 1.25 slotted 12.06 IT4-A 95021 1 4-14 1.07 1.5 1.12 1/8 12.06 IT4-S 95000 not pictured 4-14 0.7 1.5 1.12 slotted 12.03 IT-1/0 95003 1 1/0-14 1.62 1.75 1.62 3/16 6.13 ITO-1/0 95004 2 1/0-14 1.62 1.75 1.75 3/16 6.13 IT-3/0 95005 1 3/0-6 1.84 1.87 1.75 1/4 6.19 ITO-3/0 95006 2 3/0-6 1.84 1.87 1.87 1/4 6.19 ITO4-A 78924 2 4-14 1.07 1.5 1.25 1/8 12.06 IT-250 95007 3 250-6 2.12 2.13 2.31 5/16 6.24 IT-350 95008 3 350-6 2.47 2.44 2.50 5/16 4.39 IT-500 95009 3 500-4 2.87 2.94 2.81 5/16 4.53 IT-600 78944 3 600-6 3.24 3.05 2.94 5/16 4.80 IT-750* 95010 3 750-250 3.48 3.50 3.50 3/8 2.94 ITH-750 92640 4 750-250 3.48 3.50 4.50 5/16 2 1.75 600 Series are AL7CU and 75 C *Not UL Listed ISR SERIES 1 2 2 ISR Series connectors are suitable for connecting two wires in-line. Insulated with high dielectric strength plastisol and molded for precise fit. Supplied with removable access plugs over the hex screw. Abrasion and chemical resistant. UV rated. Will not support combustion. Cold temperature rated to -45 C. Dual rated for use with copper and/or aluminum cables. 600 volts. 90 C. Not recommended for use with extraflexible cables. See Polaris Grey Series page 88. UPC NO. UPC. NO 600 Series are AL7CU and 75 C FIGURE WIRE RANGE (INCHES) LENGTH HEIGHT WIDTH HEX SIZE CARTON QTY. WEIGHT LBS. EA ISR-1/0 95101 1 1/0-14 3.25 1.48.90 3/16 4.15 ISR-250 95102 1 250-6 4.00 1.90 1.19 5/16 4.34 ISR-350 95103 1 350-6 4.47 2.20 1.32 5/16 2.51 ISR-500 95104 1 500-4 4.62 3.00 1.62 5/16 2.72 ISR-600 78945 1 600-6 5.83 3.05 1.57 5/16 2 1.0 ISRH-750 92645 2 750-250 7.25 3.25 1.75 5/16 2 1.85 2010 CATALOG NSi 88

POLARIS POLARIS BLUE ISW SERIES DIRECT BURIAL AND SUBMERSIBLE IN-LINE SPLICER/REDUCERS CAT. NO. UPC CODE WIRE RANGE URD/USE THHN/XHHW* ISW Series connectors are suitable for connecting two wires in-line and are UL Listed for direct burial and submersible applications (UL486D). Insulated with specially formulated high-strength dielectric plastisol and molded for precise fit for a direct burial connection. Requires no taping, compounds, heat shrink or cutting-to-size in the INSULATION MIN DIA MAX DIA Approved for use with all conductors with insulation suitable for wet and/or damp locations. (Not recommended for use with extra flexible cable. See Polaris Grey, page 88). * Not suitable for direct burial with THHN/XHHW wire. For use in enclosures only. A properly installed connector will have no more than one conductor per port. IPLW AND ITW MULTI-CABLE CONNECTORS HEX SIZE WEIGHT LBS. field. Supplied with removable access plugs over the hex screws. Abrasion and chemical resistant. UV rated. Will not support combustion. Cold temperature rated to -45 C. Suitable for use with aluminum and/or copper conductors. 600 volts. 90 C. Reusable. (INCHES) LENGTH HEIGHT WIDTH STRIP LENGTH TIGHTENING TORQUE ISW-4 78925 4-6 AWG 0.244 0.412 slotted.12 6.39 1.38.75 1 3 /16 45 ISW-1 78926 1-2 AWG 0.352 0.582 3/16.20 6.83 1.68.88 27/32 150 ISW-3/0 78927 3/0-1/0 AWG 0.462 0.720 1/4.25 7.05 1.78.94 7/8 250 ISW-250 78928 250-4/0 AWG 0.618 0.895 5/16.40 7.58 2.13 1.13 1 1 /8 360 CAT. NO. UPC CODE NO. OF PORTS WIRE RANGE URD/USE THHN/XHHW* INSULATION MIN DIA MAX DIA HEX SIZE WEIGHT LBS. Suitable for connecting multiple wires and are UL Listed (UL486D) for direct burial and submersible applications. Insulated with specially formulated high-strength dielectric plastisol and molded for precise fit for a direct burial connection. Requires no taping, compounds, heat shrink or cuttingto-size in the field. Supplied with removable access plugs over the hex screws. Abrasion and chemical resistant. UV rated. Will not support combustion. Cold temperature rated to -45 C. Suitable for use with aluminum and/or copper conductors. 600 volts. 90 C. (INCHES) LENGTH HEIGHT WIDTH STRIP LENGTH ITW-4 95123 2 4-6 AWG.244.412 slotted.11 1.68 1.38 3.26 3/16 45 IPLW4-3 95115 3 4-6 AWG.244.412 slotted.19 2.64 1.38 3.26 3/16 45 IPLW4-4 95116 4 4-6 AWG.244.412 slotted.27 3.61 1.38 3.26 3/16 45 IPLW4-5 78929 5 4-6 AWG.244.412 slotted.35 4.57 1.38 3.26 3/16 45 IPLW4-6 78930 6 4-6 AWG.244.412 slotted.43 5.54 1.38 3.26 3/16 45 ITW-1 95126 2 1-2 AWG.352.582 3/16.19 1.87 1.68 3.55 27/32 150 IPLW1-3 95121 3 1-2 AWG.352.582 3/16.29 2.80 1.68 3.55 27/32 150 IPLW1-4 95122 4 1-2 AWG.352.582 3/16.39 3.72 1.68 3.55 27/32 150 IPLW1-5 78931 5 1-2 AWG.352.582 3/16.49 4.65 1.68 3.55 27/32 150 IPLW1-6 78932 6 1-2 AWG.352.582 3/16.59 5.57 1.68 3.55 27/32 150 ITW-3/0 95124 2 3/0-1/0 AWG.462.720 1/4.27 2.37 1.78 3.78 7/8 250 IPLW3/-03 95117 3 3/0-1/0 AWG.462.720 1/4.54 3.57 1.78 3.78 7/8 250 IPLW3/0-4 95118 4 3/0-1/0 AWG.462.720 1/4.81 4.77 1.78 3.78 7/8 250 IPLW3/0-5 78933 5 3/0-1/0 AWG.462.720 1/4 1.08 5.97 1.78 3.78 7/8 250 IPLW3/0-6 78934 6 3/0-1/0 AWG.462.720 1/4 1.35 7.17 1.78 3.78 7/8 250 ITW-250 95125 2 250-4/0 AWG.618.895 5/16.40 2.57 2.13 3.94 1 1 /8 360 IPLW250-3 95119 3 250-4/0 AWG.618.895 5/16.62 3.81 2.13 3.94 1 1 /8 360 IPLW250-4 95120 4 250-4/0 AWG.618.895 5/16.84 5.11 2.13 3.94 1 1 /8 360 IPLW250-5 78935 5 250-4/0 AWG.618.895 5/16 1.06 6.41 2.13 3.94 1 1 /8 360 IPLW250-6 78936 6 250-4/0 AWG.618.895 5/16 1.28 7.71 2.13 3.94 1 1 /8 360 Approved for use with all conductors with insulation suitable for wet and/or damp locations. (Not recommended for use with extra flexible cable. See Polaris Grey, page 88). A properly installed connector will have no more than one conductor per port. TNG. TORQ. 89 NSi POLARIS BLUE CUSTOM CONNECTORS Let us custom engineer and fabricate a UL Listed direct burial and submersible insulated combination and quantity of our standard meet your exact requirements. Wire entry can even be from either side of the connector, for direct burial or below grade use and submersible applications.

Cable

GENESIS SERIES CABLE Power Limited Fire Alarm Cable Part No. 4511 Description: 16 AWG 2/C SOL FPLP Compliance: UL Standard 1424; NEC Article 760 Construction: Conductor 16 AWG Solid Bare Copper No. of Conductors 2 Assembly Tubed jacket over twisted insulated conductors Type Color Thickness Diameter Lay Length Insulation Plenum PVC Blk, Red 0.007" nom. 0.064" nom. 2.5" nom. Type Color Thickness Diameter Legend (Ink Print) Jacket Plenum PVC Red 0.015" nom. 0.154" nom. HONEYWELL 16 AWG 2/C (ETL) FPLP/CL2P 3038058 75C W/O# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9 Properties Temperature Rating Operating Voltage Capacitance Impedance DC Resistance Flame Rating -20 to 75 o C 300 Volts max. 27 pf/ft nom 60 Ohms nom. 4.05 Ohms/M' at 20 o C UL 910, CSA FT6

GENESIS SERIES CABLE Power Limited Fire Alarm Cable Part No. 4513 Description: 14 AWG 2/C SOL FPLP Compliance: UL Standard 1424; NEC Article 760 Construction: Conductor 14 AWG Solid Bare Copper No. of Conductors 2 Assembly Tubed jacket over twisted insulated conductors Type Color Thickness Diameter Lay Length Insulation Plenum PVC Black, Red 0.007" nom. 0.078" nom. 3.0" nom. Type Color Thickness Diameter Legend (Ink Print) Jacket Plenum PVC Red 0.015" nom. 0.182" nom. HONEYWELL 14 AWG 2/C (ETL) FPLP/CL2P 3038058 75C (RoHS) W/O# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9 Properties Temperature Rating Operating Voltage Capacitance Impedance DC Resistance Flame Rating -20 to 75 o C 300 Volts max. 27 pf/ft nom 54 Ohms nom. 2.5 Ohms/M' at 20 o C UL 910, CSA FT6